Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mapper”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Analysis of the quality of image data acquired by the LANDSAT-4 Thematic Mapper (TM) of the Black Hills area, South Dakota

The structure, format, and quality of the LANDSAT-4 TM and MSS photographic and digital products for one scene covering the Black Hills area of South Dakota were assessed and the extent to which major resource categories can be detected and identified on various photographic products generated from a subset of TM spectral bands and from all bands of the MSS was determined. The overall spectral, spatial, and radiometric quality of the TM data was found to be excellent. Agricultural fields of variable shape, size, and orientation were detected with relative ease. The addition of the short-wave infrared band (TM5) has significantly improved the ability to detect and identify crop types on single date imagery.

Colwell, R. N.↗

In-flight absolute radiometric calibration of the thematic mapper

The TM multispectral scanner system was calibrated in an absolute manner before launch. To determine the temporal changes of the absolute radiometric calibration of the entire system, spectroradiometric measurements of the ground and the atmosphere were made simultaneously with TM collections over White Sands, New Mexico. By entering the measured values in an atmospheric radiative transfer program, the radiance levels of the in four of the spectral bands of the TM were determined. Tables show values for the reflectance of snow at White Sands measured by a modular 8 channel radiometer, and values for exoatmospheric irradiance within the TM passbands, calculated for the Earth-Sun distance using a solar radiometer.

Castle, K. R.↗

Spectroradiometric calibration of the thematic mapper and multispectral scanner system

The design of a spectroradiometer under construction for atmosheric and surface measurements at White Sands, New Mexico is described. The instrument's observation capability encompasses (1) measuring the solar radiance at a number of wavelengths as a function of air mass for Langley plot analysis in order to generate the optical depth; (2) measuring the ground radiance to determine the absolute ground reflectance; and (3) measuring the sky radiance as a method of checking the accuracy of the radiative transfer program.

Slater, P. N.↗

Thematic mapper radiomtric variability on ostensibly uniform agricultural scenes

The effects of the interaction of the sensor point spread function with a heterogeneous scene consisting of elements giving rise to different spectral radiant intensities cause errors in multitemporal signatures due to fractional pixel repositioning errors. In the case of a heterogeneous scene, the repositioning accuracy between acquisitions could affect the radiometric output in any band and could affect the spectral distribution of radiance between bands. Error caused by within-band and between-band variations in radiance with time could be compounded by resampling along and between scan lines during processing. The magnitude of both error sources depends on the degree of heterogeneity of the scene.

Duggin, M. J.↗

In-flight absolute radiometric calibration of the thematic mapper

In order to determine temporal changes of the absolute radiometric calibration of the entire TM system in flight spectroradiometric measurements of the ground and the atmosphere were made simultaneously with TM image collections over the White Sands, New Mexico area. By entering the measured values in an atmospheric radiative transfer program, the radiance levels in four of the spectral bands of the TM were determined, band 1:0.45 to 0.52 micrometers, band 2:0.53 to 0.61 micrometers band 3:0.62 to 0.70 micrometers and 4:0.78 to 0.91 micrometers. These levels were compared to the output digital counts from the detectors that sampled the radiometrically measured ground area, thus providing an absolute radiometric calibration of the entire TM system utilizing those detectors.

Castle, K. R.↗

LANDSAT 4 investigation of thematic mapper and multispectral scanner applications

Six different band combinations of TM data were selected for evaluation by four experienced photointerpreters who were asked to rank the band combinations according to the ease with which the category of image feature designated for each set of combinations could be distinguished. There were four sets of combinations selected for each category of image feature. Scenes of Oklahoma City, Oklahoma and of the Sacramento Valley, California area were enlarged to 1:250,000 and 2 cm circular chips were cut from each print. A nonparametric rank order test was carried out on the data to determine if the interpreters found no difference among the band combinations in ranking for the designated categories. Kendall's coefficient of concordance (W) was calculated and the significance of the W value was determined by a chi-square test. A table summarizes the results of the evaluation and shows the rank order of band combinations indicated as valid by rejection of the null hypothesis.

Lauer, D. T.↗

Comparison of the information content of data from the LANDSAT 4 Thematic Mapper and the multispectral scanner

Evaluation of information contained in data from the visible and near-IR channels of LANDSAT 4 TM and MSS for five agricultural scenes shows that the TM provides a significant advance in information gathering capability as expressed in terms of bits per pixel or bits per unit area. The six reflective channels of the TM acquire 18 bits of information per pixel out of a possible 48 bits, while the four MSS channels acquire 10 bits of information per pixel out of a possible 28 bits. Thus the TM and MSS are equally efficient in gathering information (18/48 to approximately 10/28), contrary to the expected tendency toward lower efficiency as spatial resolution is improved and spectral channels are added to an observing system. The TM thermal IR data appear to be of interest mainly for mapping water bodies, which do not change temperature during the day, for assessing surface moisture, and for monitoring thermal features associated with human activity.

Price, J. C.↗

An analysis of new techniqes for radiometric correction of LANDSAT-4 Thematic Mapper images

The utility of methods for generating TM RLUTS which can improve the quality of the resultant images was investigated. The TM-CCT-ADDS tape was changed to account for a different collection window for the calibration data. Several scenes of Terrebonne Bay, Louisiana and the Grand Bahamas were analyzed to evaluate the radiometric corrections operationally applied to the image data and to investigate several techniques for reducing striping in the images. Printer plots for the TM shutter data were produced and detector statistics were compiled and plotted. These statistics included various combinations of the average shutter counts for each scan before and after DC restore for forward and reverse scans. Results show that striping is caused by the detectors becoming saturated when they view a bright cloud and depress the DC restore level.

Kogut, J.↗

Revised radiometric calibration technique for LANDSAT-4 Thematic Mapper data by the Canada Centre for Remote Sensing

Observations of raw image data, raw radiometric calibration data, and background measurements extracted from the raw data streams on high density tape reveal major shortcomings in a technique proposed by the Canadian Center for Remote Sensing in 1982 for the radiometric correction of TM data. Results are presented which correlate measurements of the DC background with variations in both image data background and calibration samples. The effect on both raw data and data corrected using the earlier proposed technique is explained and the correction required for these factors as a function of individual scan line number for each detector is described. How the revised technique can be incorporated into an operational environment is demonstrated.

Murphy, J.↗

Revised radiometric calibration technique for LANDSAT-4 Thematic Mapper data

Depending on detector number, there are random fluctuations in the background level for spectral band 1 of magnitudes ranging from 2 to 3.5 digital numbers (DN). Similar variability is observed in all the other reflective bands, but with smaller magnitude in the range 0.5 to 2.5 DN. Observations of background reference levels show that line dependent variations in raw TM image data and in the associated calibration data can be measured and corrected within an operational environment by applying simple offset corrections on a line-by-line basis. The radiometric calibration procedure defined by the Canadian Center for Remote Sensing was revised accordingly in order to prevent striping in the output product.

Murphy, J.↗

An evaluation of thematic mapper simulator data for the geobotanical discrimination of rock types in Southwest Oregon

Rock type identification may be assisted by the use of remote sensing of associated vegetation, particularly in areas of dense vegetative cover where surface materials are not imaged directly by the sensor. The geobotanical discrimination of ultramafic parent materials was investigated and analytical techniques for lithologic mapping and mineral exploration were developed. The utility of remotely sensed data to discriminate vegetation types associated with ultramafic parent materials in a study area in southwest Oregon were evaluated. A number of specific objectives were identified, which include: (1) establishment of the association between vegetation and rock types; (2) examination of the spectral separability of vegetation types associated with rock types; (3) determination of the contribution of each TMS band for discriminating vegetation associated with rock types and (4) comparison of analytical techniques for spectrally classifying vegetation.

Weinstock, K. J.↗

Analysis of the quality of image data acquired by the LANDSAT-4 thematic mapper and multispectral scanners

A seven step procedure developed for evaluating the geometric properties of MSS and TM film produces is being implemented. Some 476 control points were selected of which 238 are being tested and edited for digitization and scaling errors. Tables show statistics established for assessing the spectral characteristics and variability, as well as the spatial resolution and radiometric sensitivity of TM data for a forest environment in an effort to determine the extent to which major forest cover type can be detected and identified on TM digital and image products. Results thus far show that the high quality obtained are more than sufficient for meeting most of the inventory objectives of the renewable resource specialist. The TM data should be extremely valuable for: (1) estimating forest cover types; (2) updating land use survey maps; and (3) determining the size and shape and location of individual forest clearings and water resources.

Colwell, R. N.↗

In-flight Absolute Radiometric Calibration of the Thematic Mapper

Ground spectral reflectance and atmospheric spectral optical depth measurements made at White Sands, New Mexico were used with an atmospheric radiative transfer program to determine the spectral radiance at the entrance pupil of the LANDSAT-4 TM. Comparison with the output digital counts of the TM, when imaging the measured ground area, provided an absolute calibration for five detectors in TM bands 2, 3, and 4. By reference to an adjacent, larger uniform area, the calibration was extended to all 16 detectors in each of three bands. Preflight calibration results agreed with these inflight measurements to 6.6%, 2.4%, and 12.9% in bands 2,3, and 4, respectively.

Palmer, J.↗

LANDSAT 4 investigations of Thematic Mapper and multispectral scanner applications

The optimum index factor package was used to choose TM band for color compositing. Processing techniques were also used on TM data over several sites to: (1) reduce the amount of data that needs to be processed and analyzed by using statistical methods or by combining full-resolution products with spatially compressed products; (2) digitally process small subareas to improve the visual appearance of large-scale products or to merge different-resolution image data; and (3) evaluate and compare the information content of the different three-band combinations that can be made using the TM data. Results indicate that for some applications the added spectral information over MSS is even more important than the TM's increased spatial resolution.

Lauer, D. T.↗

Study on spectral/radiometric characteristics of the Thematic Mapper for land use applications

An information theoretic measure of multispectral information content is developed and applied to a simultaneous LANDSAT TM and MSS data set. The entropy based function measures the dispersion and concentration of signal values in various data spaces, irrespective of specific class memberships. It is used to compare the information content of TM and MSS and of various subsets of TM and MSS bans, as well as tasseled cap transformations of the band values. Differences exist between the information measure results and results using variance based measures. System design information capacities and data space volumes are also compared. The results and observations presented are considered preliminary in nature since only one real and one simulated data set are analyzed.

Malila, W. A.↗

Spectroradiometric calibration of the Thematic Mapper and Multispectral Scanner system

The newly built Caste spectropolarimeters gave satisfactory performance during tests in the solar radiometer and helicopter modes. A bandwidth normalization technique based on analysis of the moments of the spectral responsivity curves was used to analyze the spectral bands of the MSS and TM subsystems of LANDSAT 4 and 5 satellites. Results include the effective wavelength, the bandpass, the wavelength limits, and the normalized responsivity for each spectral channel. Temperature coefficients for TM PF channel 6 were also derived. The moments normalization method used yields sensor parameters whose derivation is independent of source characteristics (i.e., incident solar spectral irradiance, atmospheric transmittance, or ground reflectance). The errors expected using these parameters are lower than those expected using other normalization methods.

Palmer, J. M.↗

Analysis of the quality of image data acquired by the LANDSAT-4 Thematic Mapper and Multispectral Scanners

The geometric quality of TM film and digital products is evaluated by making selective photomeasurements and by measuring the coordinates of known features on both the TM products and map products. These paired observations are related using a standard linear least squares regression approach. Using regression equations and coefficients developed from 225 (TM film product) and 20 (TM digital product) control points, map coordinates of test points are predicted. The residual error vectors and analysis of variance (ANOVA) were performed on the east and north residual using nine image segments (blocks) as treatments. Based on the root mean square error of the 223 (TM film product) and 22 (TM digital product) test points, users of TM data expect the planimetric accuracy of mapped points to be within 91 meters and within 117 meters for the film products, and to be within 12 meters and within 14 meters for the digital products.

Colwell, R. N.↗