Search NASA⌕ Search

SEARCH · Search NASA

Results for “NET ENERGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Energy-Efficient Supermarket Heating, Ventilation, and Air Conditioning in Humid Climates in the United States

Supermarkets are energy-intensive buildings that consume the greatest amount of electricity per square foot of building of any building type in the United States and represent 5% of total U.S. commercial building primary energy use (EIA 2005). Refrigeration and heating, ventilation, and air-conditioning (HVAC) systems are responsible for a large proportion of supermarkets’ total energy use. These two systems sometimes work together and sometimes compete, but the performance of one system always affects the performance of the other. To better understand these challenges and opportunities, the Commercial Buildings team at the National Renewable Energy Laboratory investigated several of the most promising strategies for providing energy-efficient HVAC for supermarkets and quantified the resulting energy use and costs using detailed simulations. This research effort was conducted on behalf of the U.S. Department of Energy (DOE) Commercial Building Partnerships (CBP) (Baechler et al. 2012; Parrish et al. 2013; Antonopoulos et al. 2014; Hirsch et al. 2014). The goal of CBP was to reduce energy use in the commercial building sector by creating, testing, and validating design concepts on the pathway to net zero energy commercial buildings. Several CBP partners owned or operated buildings containing supermarkets and were interested in optimizing the energy efficiency of supermarket HVAC systems in hot-humid climates. These partners included Walmart, Target, Whole Foods Market, SUPERVALU, and the Defense Commissary Agency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition. To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code (2018) in New York. The focus of this project is the 20% improvement over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate 20% energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York. Section 2 of this report describes the analysis methodology, including the building types and construction area weights update for this analysis, the baseline, and the method to conduct the energy saving analysis. Section 3 provides detailed specifications of the EEMs and bundles. Section 4 summarizes the results of individual EEMs and EEM bundles by building type, energy end-use and climate zone. Appendix A documents detailed descriptions of the selected prototype buildings. Appendix B provides energy end-use breakdown results by building type for both the baseline code and stretch code in all climate zones.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition (NYSERDA 2018). To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 in New York. The focus of this project is to significantly improve the energy efficiency over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate significant energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Innovations for Healthy Buildings

Healthy buildings provide high indoor environmental quality for occupants while simultaneously reducing energy consumption. This project advanced the development and marketability of envisioned healthy, energy-efficient buildings through studies that evaluated the use of emerging technologies in commercial and residential buildings. The project also provided resources required for homebuilders to participate in DOE’s Builders Challenge, concomitant with the goal to reduce energy consumption in homes by at least 30% as a first step toward achieving envisioned widespread availability of net-zero energy homes by 2030. In addition, the project included outreach and education concerning energy efficiency in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Supercritical water desalination and oxidation (SCWDO): Effectiveness on complex solutions, technoeconomic, and CO 2 impact for produced water treatment

The modern energy-economy is increasingly causing the production of highly saline brines, including from produced water. Supercritical water desalination can concentrate and extract minerals from these brines, but the effects of mixed salt interactions, organic degradation with additives, and the technology's economics are not well understood at supercritical condition. The present study evaluated and experimentally studied an integrated supercritical water desalination and oxidation (SCWDO) process for treating real-produced water samples from oil/natural gas field. The complex interactions between the various anions and cations in produced water were extensively evaluated. Most of the divalent and trivalent ions were extracted below 250 °C while the majority of the monovalent salt were removed between 380 to 410 °C. The treated real produced water was of drinking water quality, with <500 mg/l of total dissolved solid (TDS) and with 100% organics removal. Furthermore, the heat liberated during the organic oxidation could be utilized internally and for electricity generation for enhanced the energy efficiency and lower cost of produced water treatment. With system optimization, the proposed SCWDO process can essentially be made a net zero energy process. A novel process flow diagram for the commercial scale self-powered hybrid SCWDO technology was proposed as a cost-effective produced water treatment to mitigate the environmental crises. Techno-economic analysis showed that produced water treatment cost with SCWDO can be reduced to 2–3 $/m 3 and can be up to 60 % cheaper to traditional deep well reinjection. Additionally, the proposed SCWDO process could achieve net negative CO 2 emission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distinctive Pattern of Global Warming in Ocean Heat Content

Abstract Huge heat anomalies in the atmosphere and ocean in recent years are not yet explained. Strong characteristic patterns in temperatures for upper layers of the ocean occurred from 2000 to 2023 in the presence of global warming from increasing atmospheric greenhouse gases. Here, we show that the deep tropics are warming, although sharply modulated by El Niño–Southern Oscillation events, with strong heating in the extratropics near 40°N and 40°–45°S but little heating near 20°N and 25°–30°S. The heating is most clearly manifested in zonal-mean ocean heat content and is evident in sea surface temperatures. The strongest heating is in the Southern Hemisphere, where aerosol effects are small. Estimates are made of the contributions to heating of top-of-atmosphere (TOA) radiation, atmospheric energy transports, surface fluxes of energy, and redistribution of energy by surface winds and ocean currents. The patterns of change are not directly related to TOA radiation but are evident in net surface energy fluxes and inferred ocean heat transports, underscoring their coupled origin. Changes in the atmospheric circulation through a poleward shift in ocean jet streams and storm tracks are reflected in surface wind-driven ocean Ekman transports. As well as human-induced climate change, internal natural variability is likely in play. Hence, the atmosphere and ocean currents are systematically redistributing heat from global warming, profoundly affecting local climates. Significance Statement As the climate changes, it has been difficult to discern meaningful patterns. Distinctive patterns of change have occurred in the ocean when examined as zonal averages around latitude bands. Most excess heat from global warming resides in the ocean and, since 2005, has become focused into bands near 40°N and 40°S, with little net warming in the subtropics. The strongest warming is in the Southern Hemisphere, although sea surface temperatures have increased more in the Northern Hemisphere. Changes in the atmospheric circulation through a poleward shift in the jet stream and storm tracks are primarily responsible along with corresponding changes in ocean currents. These changes are linked through surface exchanges of energy via heat, moisture, and wind stress.

Trenberth, Kevin E. [National Center for Atmospher↗

Optimizing Distributed Energy Resources and building retrofits with the strategic DER-CAModel

The pressuring need to reduce the import of fossil fuels as well as the need to dramatically reduce CO 2 emissions in Europe motivated the European Commission (EC) to implement several regulations directed to building owners. Most of these regulations focus on increasing the number of energy efficient buildings, both new and retrofitted, since retrofits play an important role in energy efficiency. Overall, this initiative results from the realization that buildings will have a significant impact in fulfilling the 20/20/20-goals of reducing the greenhouse gas emissions by 20%, increasing energy efficiency by 20%, and increasing the share of renewables to 20%, all by 2020. The Distributed Energy Resources Customer Adoption Model (DER-CAM) is an optimization tool used to support DER investment decisions, typically by minimizing total annual costs or CO 2 emissions while providing energy services to a given building or microgrid site. This document shows enhancements made to DER-CAM to consider building retrofit measures along with DER investment options. Specifically, building shell improvement options have been added to DER-CAM as alternative or complementary options to investments in other DER such as PV, solar thermal, combined heat and power, or energy storage. The extension of the mathematical formulation required by the new features introduced in DER-CAM is presented and the resulting model is demonstrated at an Austrian Campus building by comparing DER-CAM results with and without building shell improvement options. Strategic investment results are presented and compared to the observed investment decision at the test site. Results obtained considering building shell improvement options suggest an optimal weighted average U value of about 0.53 W/(m 2 K) for the test site. This result is approximately 25% higher than what is currently observed in the building, suggesting that the retrofits made in 2002 were not optimal. Furthermore, the results obtained with DER-CAM illustrate the complexity of interactions between DER and passive measure options, showcasing the need for a holistic optimization approach to effectively optimize energy costs and CO 2 emissions. Lastly, the simultaneous optimization of building shell improvements and DER investments enables building owners to take one step further towards nearly zero energy buildings (nZEB) or nearly zero carbon emission buildings (nZCEB), and therefore support the 20/20/20 goals.

25 ENERGY STORAGE↗

Determining a hopping polaron's bandwidth from its Seebeck coefficient: Measuring the disorder energy of a non-crystalline semiconductor

Charge carriers that execute multi-phonon hopping generally interact strongly enough with phonons to form polarons. A polaron's sluggish motion is linked to slowly shifting atomic displacements that severely reduce the intrinsic width of its transport band. Here a means to estimate hopping polarons' bandwidths from Seebeck-coefficient measurements is described. The magnitudes of semiconductors' Seebeck coefficients are usually quite large (>k/|q| = 86 μV/K) near room temperature. However, in accord with the third law of thermodynamics, Seebeck coefficients must vanish at absolute zero. Here, the transition of the Seebeck coefficient of hopping polarons to its low-temperature regime is investigated. The temperature and sharpness of this transition depend on the concentration of carriers and on the width of their transport band. This feature provides a means of estimating the width of a polaron's transport band. Since the intrinsic broadening of polaron bands is very small, less than the characteristic phonon energy, the net widths of polaron transport bands in disordered semiconductors approach the energetic disorder experienced by their hopping carriers, their disorder energy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fort Carson Building 1860 Biomass Heating Analysis Report

As part of the Army Net-Zero Energy Installation program, the Fort Carson Army Base requested that NREL evaluate the feasibility of adding a biomass boiler to the district heating system served by Building 1860. We have also developed an Excel-spreadsheet-based decision support tool--specific to the historic loads served by Building 1860--with which users can perform what-if analysis on gas costs, biomass costs, and other parameters. For economic reasons, we do not recommend adding a biomass system at this time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Master Planning for Resilient Public Communities—Best Practices from U.S. Military Installations

Until recently, most planners at military installations addressed energy systems for new facilities on an individual facility basis without consideration of community-wide goals relevant to energy sources, renewables, storage, or future energy generation needs. Building retrofits of public buildings typically do not address energy needs beyond the minimum code requirements making it difficult, if not impossible, to achieve community-level targets on a building-by-building basis. Planning on the basis of cost and general reliability may also fail to deliver community-level resilience. For example, many building code requirements focus on hardening to specific threats, but in a multi-building community, only a few of these buildings may be mission-critical. Over the past two decades, the frequency and duration of regional power outages and water utility disruptions from weather, man-made events, and aging infrastructure have increased. Major disruptions of electric and thermal energy have degraded critical mission capabilities and caused significant economic impacts. In 2016, the U.S. Department of Defense issued guidance that each Service (Army, Navy, Air Force, Marines) complete comprehensive energy plans for the installations that consumed 75% of total building energy. Guidance was updated in 2017 to include metrics for energy resilience, and in some cases, water. This paper describes how community level quantitative and qualitative resilience analysis and metrics have been incorporated into community energy and water planning best practices for military installations in three geographically diverse locations. It is based on research performed under the International Energy Agency’s “Energy in Buildings and Communities Program Annex 73,” focusing on development of guidelines and tools that support the planning of Net Zero Energy Resilient Public Communities as well as research performed under the Department of Defense Environmental Security Technology Certification Program project EW18-D1- 5281, “Technologies Integration to Achieve Resilient, Low- Energy Military Installations.” The first case study reviews progress made on an energy and water planning study conducted at Fort Bliss, Texas. The second and third describes planning conducted at Fort Bragg, North Carolina and the Joint Region Marianas, Guam, respectively, under the updated guidance from 2017 regarding energy and water resilience. Analysis methods, key metrics, and key infrastructure and operational constraints are described, as well as technical, economic and business concepts used during the planning process.

Urban, Angela B.↗

Distribution Grid Incentive Design with Unknown Agent Behavior

Motivation: During extreme events, traditional grid regulation methods (e.g., energy prices, net power injection limits) may be insufficient. While system operators typically lack control over end-user grid interactions, (e.g., energy demand), incentives can influence behavior - for example, a user that receives a grid-driven incentive may adjust their consumption or expose relevant control variables in response. Problem: Optimize for the best incentive subject to system stability constraints. However, user behavior is unknown to the SO - i.e., for a given incentive, the amount of curtailed load or control variables exposed is unknown.

feedback based control↗

State-of-the-Art Analysis of Nearly Zero Energy Buildings

The IEA HPT Annex 49 "Design and integration of heat pumps for Nearly Zero Energy Buildings" deals with the design and integration of heat pumps as core component of the HVAC system for Nearly or Net Zero energy buildings (NZEB).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Putting Carbon in its Place: What You Can Do (LBNL Science at the Theater)

Science at the Theater: Berkeley Lab scientists reveal the latest research on how to reduce your carbon footprint at home, work, and when you shop. Learn how even small choices can have a big impact. Iain Walker's research focuses on optimizing the energy use and comfort of buildings. He's a staff scientist in the Energy Performance of Buildings Group, which is part of Berkeley Lab's Environmen...tal Energy Technologies Division. He's also executive editor of Home Energy Magazine. Cindy Regnier is a Project Manager in the Environmental Energy Technologies Division at Berkeley Lab. She has over 13 years of mechanical engineering design experience, with a focus on low-energy buildings. Her projects have included several LEED Platinum buildings and the design of a 200,000 sf carbon neutral, net-zero energy science museum in San Francisco. Eric Masanet is Acting Deputy Leader of the International Energy Studies Group at Berkeley Lab. His research focuses on life-cycle assessments and energy efficiency analysis. He holds a joint research appointment in the Institute of Transportation Studies at UC Berkeley.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sacramento State Solar Decathlon 2015: Research Performance Final Report

Our primary objective is to design and build a 600-1000sf home that produces more energy than it consumes and to showcase this home at the 2015 Solar Decathlon in Irvine, CA. Further objectives are to educate consumers and home builders, alike (including K-12 students – the industry’s future consumers), inspire a shift towards the adoption of net-zero energy solutions in residential building, and to be a leader in the transformation of the California residential marketplace to a net-zero standard. Our specific mission statement for this project is as follows: Solar NEST strives to discover the future of sustainable, energy-efficient housing and deliver these innovations to home buyers at an affordable price. To make substantial improvements to conventional building methods with regard to aesthetics, performance, and affordability. Through our efforts, we aspire to bridge the gap between ‘what is’ and ‘what is possible’ by providing unique, elegant simplicity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementing a Zero Energy Ready Home Multifamily Project

Building cost-effective, high-performance homes that provide superior comfort, health, and durability is the goal of the U.S. Department of Energy’s (DOE’s) Zero Energy Ready Home (ZERH) program. Building America research and other innovative programs throughout the country have addressed many of the technical challenges of building to the ZERH standard. The cost-effectiveness of measure packages that result in 30% source energy savings compared to a code-compliant home have been demonstrated. However, additional challenges remain, particularly with respect to convincing production builders of the strong business case for ZERH. The Alliance for Residential Building Innovation (ARBI) team believes that the keys to successfully engaging builders and developers in the California market are to help them leverage development agreement requirements, code compliance requirements, incentives, and competitive market advantages of ZERH certification, and navigate through this process. A primary objective of this project was to gain a highly visible foothold for residential buildings that are built to the DOE ZERH specification that can be used to encourage participation by other California builders. This report briefly describes two single-family homes that were ZERH certified and focuses on the experience of working with developer Mutual Housing on a 62-unit multifamily community at the Spring Lake subdivision in Woodland, California. The Spring Lake project is expected to be the first ZERH-certified multifamily project in the country. This report discusses the challenges encountered, lessons learned, and how obstacles were overcome.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementing a Zero Energy Ready Home Multifamily Project

An objective of this project was to gain a highly visible foothold for residential buildings built to the U.S. Department of Energy's Zero Energy Ready Home (ZERH) specification that can be used to encourage participation by other California builders. This report briefly describes two single family homes that were ZERH-certified, and focuses on the experience of working with developer Mutual Housing on a 62 unit multi-family community at the Spring Lake subdivision in Woodland, CA. The Spring Lake project is expected to be the first ZERH certified multi-family project nationwide. This report discusses challenges encountered, lessons learned, and how obstacles were overcome.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

In 2017, New York State Energy Research and Development Authority (NYSERDA) developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code. Since2017, NYSERDA has continued to develop the 2018 edition, as part of the efforts to achieve a statewide Net Zero Energy Code by 2028. To support this effort, Pacific Northwest National Laboratory (PNNL)conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 compared to ANSI/ASHRAE/IES1 Standard 90.1-2013. Specifically, PNNL collaborated with New Buildings Institute (NBI), and developed energy-efficiency measures (EEMs) from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the ongoing NYStretch-Energy code development process. PNNL analyzed these measures using whole building energy simulation for selected prototype commercial and multifamily buildings representing buildings in New York State.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

New Whole-House Solutions Case Study: Zero Energy Ready Home Multifamily Project: Mutual Housing at Spring Lake

Building cost effective, high performance homes that provide superior comfort, health, and durability is the goal of the Department of Energy's (DOE's) Zero Energy Ready Homes (ZERH) program. This case study describes the development of a 62-unit multifamily community constructed by nonprofit developer Mutual Housing at the Spring Lake subdivision in Woodland, California. The Spring Lake project is expected to be the first ZERH-certified multifamily project nationwide. Building America team Alliance for Residential Building Innovation worked with Mutual Housing throughout the project. An objective of this project was to gain a highly visible foothold for residential buildings built to the DOE ZERH specification that can be used to encourage participation by other California builders.

ARBI↗