Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Subcellular boron and fluorine distributions with SIMS ion microscopy in BNCT and cancer research

The development of a secondary ion mass spectrometry (SIMS) based technique of Ion Microscopy in boron neutron capture therapy (BNCT) was the main goal of this project, so that one can study the subcellular location of boron-10 atoms and their partitioning between the normal and cancerous tissue. This information is fundamental for the screening of boronated drugs appropriate for neutron capture therapy of cancer. Our studies at Cornell concentrated mainly on studies of glioblastoma multiforme (GBM). The early years of the grant were dedicated to the development of cryogenic methods and correlative microscopic approaches so that a reliable subcellular analysis of boron-10 atoms can be made with SIMS. In later years SIMS was applied to animal models and human tissues of GBM for studying the efficacy of potential boronated agents in BNCT. Under this grant the SIMS program at Cornell attained a new level of excellence and collaborative SIMS studies were published with leading BNCT researchers in the U.S.

54 ENVIRONMENTAL SCIENCES↗

Approximating the r-Process on Earth with Thermonuclear Explosions. Lessons Learned and Unanswered Questions

During the astrophysical r-process, multiple neutron captures occur so rapidly on target nuclei that their daughter nuclei generally do not have time to undergo radioactive decay before another neutron is captured. The r-process can be approximately simulated on Earth in certain types of thermonuclear explosions through an analogous process of rapid neutron captures known as the "prompt capture" process. Between 1952 and 1969, 23 nuclear tests were fielded by the US which were involved (at least partially) with the "prompt capture" process. Of these tests, 15 were at least partially successful. Some of these tests were conducted under the Plowshare Peaceful Nuclear Explosion Program as scientific research experiments. It is now known that the USSR conducted similar nuclear tests during 1966 to 1979. The elements einsteinium and fermium were first discovered by this process. The most successful tests achieved 19 successive neutron captures on the initial target nuclei. A review of the US program, target nuclei used, heavy element yields, scientific achievements of the program, and how some of the results have been used by the astrophysical community is given. Finally, some unanswered questions concerning very neutron-rich nuclei that could potentially have been answered with additional nuclear experiments is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron spectroscopy by thermalization light yield measurement in a composite heterogeneous scintillator

An exothermic neutron capture reaction can be used to uniquely identify neutrons in particle detectors. With the use of a capture-gated coincidence technique, the sequence of scatter events that lead to neutron thermalization prior to the neutron capture can also be used to measure neutron energy. We report on the measurement of thermalization light yield via a time-of-flight technique in a polyvinyl toluene-based scintillator EJ-290 within a heterogeneous composite detector that also includes 6Li-doped glass scintillator. The thermalization light output exhibits a strong correlation with neutron energy because of the preference for near-complete energy deposition prior to the 6Li(n,t)4He neutron capture reaction. The nonproportionality of the light yield from nuclear recoils contributes to the observed broadening of the distribution of thermalization light output. The nonproportional dependence of the scintillation light output in the EJ-290 scintillator as a function of proton recoil energy has been characterized in the range of 0.3–14.1 MeV via the Birks parametrization through a combination of time-of-flight measurement and previously conducted measurements with Monoenergetic neutron sources.

6Li-doped scintillator↗

The isovector imaginary neutron potential: a key ingredient for the r-process nucleosynthesis

The isovector contribution to the imaginary component of the microscopic optical model potential is adjusted on experimental neutron strength function data. Within the Brueckner-Hartree-Fock approximation of Jeukenne-Lejeune-Mahaux, it is shown that experimental data favours a strong isovector component that can have a drastic impact on the radiative neutron capture cross section for neutron-rich nuclei. If confirmed, this result strongly inhibits the resonant capture by exotic nuclei, so that the traditional r-process picture of the fast neutron captures during the nucleosynthesis r-process needs to be revisited in depth.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spin and Parity Assignment of Neutron Resonances using Gamma-ray Multiplicity

Decay gamma rays following neutron capture on various isotopes are collected by the Detector for Advanced Neutron Capture Experiments (DANCE) array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation (160 detectors) and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a specific resonance of a given isotope in the time-of-flight spectrum and obtain the summed energy spectrum for that isotope. The singles gamma-ray spectrum for each multiplicity can be separated by their DANCE cluster multiplicity. The multiplicity distribution contains the signatures of spin and parity of the capture state. Under suitable circumstances where the difference between spins of the initial (capture) and final (ground) state is large enough, the signatures in the multiplicity distribution can be used in improving the spin assignment of the initial state. The spin assignment is applied with varying degree of success to difference isotopes and description of this application for {sup 95}Mo, {sup 151,153}Eu, and {sup 155,157}Gd is reviewed briefly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High yield neutron generator based on a high-current gasdynamic electron cyclotron resonance ion source

In present paper, an approach for high yield compact D-D neutron generator based on a high current gasdynamic electron cyclotron resonance ion source is suggested. Results on dense pulsed deuteron beam production with current up to 500 mA and current density up to 750 mA/cm{sup 2} are demonstrated. Neutron yield from D{sub 2}O and TiD{sub 2} targets was measured in case of its bombardment by pulsed 300 mA D{sup +} beam with 45 keV energy. Neutron yield density at target surface of 10{sup 9} s{sup −1} cm{sup −2} was detected with a system of two {sup 3}He proportional counters. Estimations based on obtained experimental results show that neutron yield from a high quality TiD{sub 2} target bombarded by D{sup +} beam demonstrated in present work accelerated to 100 keV could reach 6 × 10{sup 10} s{sup −1} cm{sup −2}. It is discussed that compact neutron generator with such characteristics could be perspective for a number of applications like boron neutron capture therapy, security systems based on neutron scanning, and neutronography.

07 ISOTOPE AND RADIATION SOURCES↗

The study of physics and safety characteristics for In-Hospital Neutron Irradiator (IHNI)

The IHNI is designed with low-enrichment {sup 235}U (LEU) for Boron Neutron Capture Therapy (BNCT) based on Miniature Neutron Source Reactor (MNSR). The IHNI, operated with thermal power 30kW, is an under-moderated reactor of pool-tank type, and UO{sub 2} as fuel, light water as coolant and moderator, and metallic beryllium as reflector. The paper gives the physics and safety characteristics of IHNI. The physics characteristics include those parameters of the criticality and the beam port used for BNCT. The safety characteristics compare the safety parameters between reactor core of LEU and HEU. The result shows that LEU could meet the requirements of criticality and flux at exit of each beam. Furthermore, the better safety characteristics could approach by adopting the LEU in comparison with HEU. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The physics experimental study for in-hospital neutron irradiator

MNSRs (Miniature Neutron Source Reactor) are low power research reactors designed and manufactured by China Institute of Atomic Energy (CIAE). MNSRs are mainly used for NAA, training and teaching, testing of nuclear instrumentation. The first MNSR, the prototype MNSR, was put into operation in 1984, later, eight other MNSRs had been built both at home and abroad. For MNSRs, highly enriched uranium (90%) is used as the fuel material. The In-Hospital Neutron Irradiator (IHNI) is designed for Boron Neutron Capture Therapy (BNCT) based on Miniature Neutron Source Reactor(MNSR). On both sides of the reactor core, there are two neutron beams, one is thermal neutron beam, and the other opposite to the thermal beam, is epithermal neutron beam. A small thermal neutron beam is specially designed for the measurement of blood boron concentration by the prompt gamma neutron activation analysis (PGNAA). In this paper, the experimental results of critical mass worth of the top Be reflectors worth of the control rod, neutron flux distribution and other components worth were measured, the experiment was done on the Zero Power Experiment equipment of MNSR. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

R-MATRIX ANALYSIS of 232Th NEUTRON TRANSMISSIONS and CAPTURE CROSS SECTIONS in the ENERGY RANGE THERMAL to 4 keV

Neutron resonance parameters of 232Th were obtained from the Reich-Moore SAMMY analysis of high-resolution neutron transmission measurements performed at the Oak Ridge Electron Linear Accelerator (ORELA) by Olsen in 1981, along with the high-resolution neutron capture measurements performed in 2005 at the Geel Linear Accelerator (GELINA, Belgium) by Schillebeeckx and at the n-TOF facility (CERN, Switzerland) by Aerts. The ORELA data were analyzed previously by Olsen with the Breit-Wigner multilevel code SIOB, and the results were used in the ENDF/B-VI evaluation. In the new analysis of the Olsen neutron transmissions by the modern computer code SAMMY, better accuracy is obtained for the resonance parameters by including in the experimental data base the recent experimental neutron capture data. The experimental data base and the method of analysis are described in the report. The neutron transmissions and the capture cross sections calculated with the resonance parameters are compared to the experimental values. A description is given of the statistical properties of the resonance parameters. The new evaluation results in a decrease in the capture resonance integral and improves the prediction of integral thermal benchmarks.

232 Th NeutronTransmission↗

Photon strength and the low-energy enhancement

Several measurements in medium mass nuclei have reported a low-energy enhancement in the photon strength function. Although, much effort has been invested in unraveling the mysteries of this effect, its physical origin is still not conclusively understood. Here, a completely model-independent experimental approach to investigate the existence of this enhancement is presented. The experiment was designed to study statistical feeding from the quasi-continuum (below the neutron separation energy) to individual low-lying discrete levels in {sup 95}Mo produced in the (d, p) reaction. A key aspect to successfully study gamma decay from the region of high-level density is the detection and extraction of correlated particle-gamma-gamma events which was accomplished using an array of Clover HPGe detectors and large area annular silicon detectors. The entrance channel excitation energy into the residual nucleus produced in the reaction was inferred from the detected proton energies in the silicon detectors. Gating on gamma-transitions originating from low-lying discrete levels specifies the state fed by statistical gamma-rays. Any particle-gamma-gamma event in combination with specific energy sum requirements ensures a clean and unambiguous determination of the initial and final state of the observed gamma rays. With these requirements the statistical feeding to individual discrete levels is extracted on an event-by-event basis. The results are presented and compared to {sup 95}Mo photon strength function data measured at the University of Oslo.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extremely Low Energy Nuclear Recoil Calibrations for Dark Matter Direct Detection (Final Technical Report)

This project developed and demonstrated a new calibration approach for low-energy nuclear recoils in solid-state detectors based on neutron capture. Precise calibration in the sub-keV regime is a critical challenge across the HEP portfolio. Existing measurements show deviations and inconsistencies across methods. Neutron capture provides a complementary approach producing discrete recoils via γ cascades.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Following Fission Products in Explosive Astrophysical Environments

The astrophysical process by which the heaviest elements are formed in the universe is known as the rapid neutron capture process, or r process, of nucleosynthesis. The r process is characterized by the neutron capture and β - decay of short-lived, neutron-rich atomic nuclei; in suitably extreme environments, nuclear fission can also play a major role in determining the ensuing nucleosynthesis. In this work, we present the application of our recently developed nucleosynthesis tracing framework to precisely quantify the impact that neutron-induced and β - -delayed fission processes have in r-process environments that produce fissioning nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

A Study of 3He detectors for Active Interrogation

3He proportional counters have long been used as neutron detectors for both passive and active detection of Special Nuclear Material (SNM). The optimal configuration of these detectors as far as gas pressure, amount of moderating material, and size are concerned is highly dependent on what neutron signatures are being used to detect and identify SNM. We present here a parametric study of the neutron capture response of 3He detectors, based on Monte Carlo simulations using the MCNPX radiation transport code. The neutron capture response of the detectors has been modeled as a function of time after an incident neutron pulse.

3He↗

169 Tm ( n , γ ) cross section and statistical decay properties from measurements at the DANCE facility

Background: Radiative neutron capture on thulium, which is a monoisotopic element, plays a role in different applications such as nuclear astrophysics or nuclear burning environments. Considerable discrepancies—reaching 20%—exist between evaluations in the unresolved-resonance region. Furthermore, experimental data on statistical 𝛾 decay in odd-odd rare-earth nuclei is scarce. There are still open questions about the systematics of the so-called scissors mode in the 𝑀⁢1 photon strength function, especially in odd-odd nuclei. Purpose: This work is focused on two main topics—deriving experimental 169 Tm ⁢(𝑛,𝛾) cross section and studying statistical 𝛾 decay of 170 Tm, in particular properties of the scissors mode. Methods: The capture experiments to obtain experimental cross section were performed at the Los Alamos Neutron Science Center using the time-of-flight technique and employing the Detector for Advanced Neutron Capture Experiments. Measured coincident 𝛾-ray spectra were also compared with statistical simulations using the dicebox code to test different models of level density and photon strength functions. Results: The capture cross section was determined from 1.8 eV to 0.97 MeV, the broadest neutron-energy range ever measured for this isotope. Several new resonances have been observed. The statistical 𝛾 decay of 170 Tm cannot be reproduced without a scissors mode resonance centered at ≈ 3.3MeV. Conclusions: The measured cross section in the unresolved-resonance region is generally lower than the latest evaluations. The derived 169 Tm 𝑠-process abundance is expected to increase by a factor of 1.26, while the changes of the abundances of elements heavier than 169 Tm are in the order of 0.2%. The scissors mode properties in 170 Tm are similar to those deduced in previous analyses of neighboring nuclei 168 Er and 166 Ho .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear Physics for the Re/Os Clock

Dating the age of the universe by the {beta}-decay of {sup 187}Re (t{sub 1/2} = 41.2 Gyr) requires the accurate assessment of the s-process reaction flow. The daughter nucleus {sup 187}Os as well as its immediate s-only neighbor {sup 186}Os are shielded from the r-process. Therefore, the radiogenic contribution to {sup 187}Os can be derived via the local approximation of the s-process, which is well justified in this mass region: ({l_angle}{sigma}{r_angle}N{sub s})187 = ({l_angle}{sigma}{r_angle}N{sub s})186. Accordingly, accurate Maxwellian-averaged (n, {gamma}) cross sections have to be known for {sup 186}Os and {sup 187}Os over the full range of s-process temperatures. Because {sup 187}Os has low-lying excited states, which are significantly populated during the s-process, neutron captures on these excited states have to be properly taken into account. The input for the corresponding Hauser-Feshbach calculations can be constrained by deriving the strength functions from a detailed resonance analysis of the measured (n, {gamma}) cross sections as well as by an additional measurement of the inelastic scattering cross section for the first exited level, which dominates the competition between the capture and scattering channels. This contribution reports on measurements of the neutron capture cross sections of {sup 186}Os, {sup 187}Os and {sup 188}Os from the eV region to 1 MeV at the CERN/n{_}TOF facility and of the inelastic scattering cross section of {sup 187}Os around 30 keV at the Karlsruhe 3.7 MV Van de Graaff accelerator. Based on these results and on a detailed resonance analysis, improved Maxwellian-averaged cross sections were obtained for thermal energies between 5 keV and 100 keV. The implications of these results for the Re/Os clock are discussed.

43 PARTICLE ACCELERATORS↗

A fuel for sub-critical fast reactor

Along with the problem of the nuclear waste transmutation, the problem of minimization of waste production is of current interest. It is not possible to eliminate production of waste at a nuclear power plant, but, as is shown in this report, it is in principle possible to arrange a fuel composition with no net production of transuranic elements. The idea is to find the transuranic elements composition to which the depleted uranium is continuously supplied during frequent reprocessing, and amount of each other transuranic fuel component remains unchanged in time. For each transuranic component, the balance is achieved by equating burnup and production rates. The production is due to neutron capture by the neighboring lighter isotope and subsequent beta-decay. The burnup includes fission, neutron capture and decays. For the calculations a simplified burnup model which accounts for 9 isotopes of uranium, neptunium, plutonium and americium is used. The calculated fuel composition consists mainly of uranium with minority of plutonium isotopes. Such a fuel, after usage in a sub-critical fast reactor, should be reprocessed. The fission product content increases during burnup, representing a net production of waste, while the transuranic elements and {sup 238}U should be recycled into a new fuel. For such a fuel cycle, the net consumption is only for 238U, and the net waste production is just fission products.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A compact gas-filled avalanche counter for DANCE

A compact gas-filled avalanche counter for the detection of fission fragments was developed for a highly segmented 4π γ-ray calorimeter, namely the Detector for Advanced Neutron Capture Experiments located at the Lujan Center of the Los Alamos Neutron Science Center. It has been used successfully for experiments with 235 U, 238 Pu, 239 Pu, and 241 Pu isotopes to provide a unique signature to differentiate the fission from the competing neutron-capture reaction channel. We also used it to study the spontaneous fission in 252Cf. The design and performance of this avalanche counter for targets with extreme α-decay rate up to ~2.4×108/s are described.

252Cf↗