Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Evaluation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Stability and accuracy of 3D neutron transport simulations using the 2D/1D method in MPACT

A consistent “2D/1D” neutron transport method is derived from the 3D Boltzmann transport equation, to calculate fuel-pin-resolved neutron fluxes for realistic full-core Pressurized Water Reactor (PWR) problems. The 2D/1D method employs the Method of Characteristics to discretize the radial variables and a lower order transport solution to discretize the axial variable. This paper describes the theory of the 2D/1D method and its implementation in the MPACT code, which has become the whole-core deterministic neutron transport solver for the Consortium for Advanced Simulations of Light Water Reactors (CASL) core simulator VERA-CS. Several applications have been performed on both leadership-class and industry-class computing clusters. Results are presented for whole-core solutions of the Watts Bar Nuclear Power Station Unit 1 and compared to both continuous-energy Monte Carlo results and plant data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Retrospective Reconstructions of Active Bone Marrow Dose-Volume Histograms

Purpose: To present a method for calculating dose-volume histograms (DVH's) to the active bone marrow (ABM) of patients who had undergone radiation therapy (RT) and subsequently developed leukemia. Methods and Materials: The study focuses on 15 patients treated between 1961 and 1996. Whole-body RT planning computed tomographic (CT) data were not available. We therefore generated representative whole-body CTs similar to patient anatomy. In addition, we developed a method enabling us to obtain information on the density distribution of ABM all over the skeleton. Dose could then be calculated in a series of points distributed all over the skeleton in such a way that their local density reflected age-specific data for ABM distribution. Dose to particular regions and dose-volume histograms of the entire ABM were estimated for all patients. Results: Depending on patient age, the total number of dose calculation points generated ranged from 1,190,970 to 4,108,524. The average dose to ABM ranged from 0.3 to 16.4 Gy. Dose-volume histograms analysis showed that the median doses (D{sub 50%}) ranged from 0.06 to 12.8 Gy. We also evaluated the inhomogeneity of individual patient ABM dose distribution according to clinical situation. It was evident that the coefficient of variation of the dose for the whole ABM ranged from 1.0 to 5.7, which means that the standard deviation could be more than 5 times higher than the mean. Conclusions: For patients with available long-term follow-up data, our method provides reconstruction of dose-volume data comparable to detailed dose calculations, which have become standard in modern CT-based 3-dimensional RT planning. Our strategy of using dose-volume histograms offers new perspectives to retrospective epidemiological studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Predictive Models for Advanced Reactor Autonomous Control

Advanced reactor designs including microreactors and small modular reactors will contribute to the clean production of cheap energy, and autonomous control for advanced reactors is an appealing option for reducing cost. However, there is a lack of industry experience applying autonomous control for advanced nuclear reactors. To accelerate the development and industry acceptance of autonomous control software for nuclear reactors, we aim to demonstrate autonomous control of the Purdue University research reactor (PUR-1) using INL-developed model predictive control (MPC) methods. To prepare for this demonstration, data-driven predictive models based on process data collected from PUR-1 have been developed and integrated with MPC and used to control a physics-based model of PUR-1. A data-driven dynamics model and a gated recurrent unit (GRU) network were both trained on process data from PUR-1. The dynamics model was shown to effectively control the reactor model with MPC when provided reactivity as a control variable but failed to control the model through the control rod positions. The GRU network produced more accurate predictions than the dynamics model when evaluated on operational data, and future work will include the evaluation of the GRU network in the controller.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Active Time-Domain Reflectometry for Unattended Safeguards Systems FY15 Report

The International Atomic Energy Agency (IAEA) continues to expand its use of unattended measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. In collaboration with the IAEA, tamper-indicating measures to address data-transmission authentication challenges with unattended safeguards systems are under investigation. Pacific Northwest National Laboratory (PNNL) is studying the viability of active time-domain reflectometry (TDR) along two parallel but interconnected paths: (1) swept-frequency TDR as the highly flexible, laboratory gold standard to which field-deployable options can be compared, and (2) a low-cost commercially available spread-spectrum TDR technology as one option for field implementation. This report describes PNNL’s FY15 progress in the viability study including: an overview of the TDR methods under investigation; description of the testing configurations and mock tampering scenarios; results from a preliminary sensitivity comparison of the two TDR methods; demonstration of a quantitative metric for estimating field performance that acknowledges the need for high detection probability while minimizing false alarms. FY15 progress reported here sets the stage for a rigorous comparison of the candidate TDR methods, over a range of deployment scenarios and perturbing effects typical of IAEA unattended monitoring systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality assurance of asymmetric jaw alignment using 2D diode array

Purpose: A method using a 2D diode array is proposed to measure the junction gap (or overlap) and dose with high precision for routine quality assurance of the asymmetric jaw alignment.Methods: The central axis (CAX) of the radiation field was determined with a 15 × 15 cm{sup 2} photon field at four cardinal collimator angles so that the junction gap (or overlap) can be measured with respect to the CAX. Two abutting fields having a field size of 15 cm (length along the axis parallel to the junction) × 7.5 cm (width along the axis perpendicular to the junction) were used to irradiate the 2D diode array (MapCHECK2) with 100 MU delivered at the photon energy of 6 MV. The collimator was slightly rotated at 15° with respect to the beam central axis to increase the number of diodes effective on the measurement of junction gap. The junction gap and dose measured in high spatial resolution were compared to the conventional methods using an electronic portal imaging device (EPID) and radiochromic film, respectively. In addition, the reproducibility and sensitivity of the proposed method to the measurements of junction gap and dose were investigated.Results: The junction gap (or overlap) and dose measured by MapCHECK2 agreed well to those measured by the conventional methods of EPID and film (the differences ranged from −0.01 to 0 cm and from −1.34% to 0.6% for the gap and dose, respectively). No variation in the repeat measurements of the junction gap was found whereas the measurements of junction dose were found to vary in quite a small range over the days of measurement (0.21%–0.35%). While the sensitivity of the measured junction gap to the actual junction gap applied was the ideal value of 1 cm/cm as expected, the sensitivity of the junction dose to the actual junction gap increased as the junction gap (or overlap) decreased (maximum sensitivity: 201.7%/cm).Conclusions: The initial results suggest that the method is applicable for a comprehensive quality assurance of the asymmetric jaw alignment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

INL Results for Phases I and III of the OECD/NEA MHTGR-350 Benchmark

The Idaho National Laboratory (INL) Very High Temperature Reactor (VHTR) Technology Development Office (TDO) Methods Core Simulation group led the construction of the Organization for Economic Cooperation and Development (OECD) Modular High Temperature Reactor (MHTGR) 350 MW benchmark for comparing and evaluating prismatic VHTR analysis codes. The benchmark is sponsored by the OECD's Nuclear Energy Agency (NEA), and the project will yield a set of reference steady-state, transient, and lattice depletion problems that can be used by the Department of Energy (DOE), the Nuclear Regulatory Commission (NRC), and vendors to assess their code suits. The Methods group is responsible for defining the benchmark specifications, leading the data collection and comparison activities, and chairing the annual technical workshops. This report summarizes the latest INL results for Phase I (steady state) and Phase III (lattice depletion) of the benchmark. The INSTANT, Pronghorn and RattleSnake codes were used for the standalone core neutronics modeling of Exercise 1, and the results obtained from these codes are compared in Section 4. Exercise 2 of Phase I requires the standalone steady-state thermal fluids modeling of the MHTGR-350 design, and the results for the systems code RELAP5-3D are discussed in Section 5. The coupled neutronics and thermal fluids steady-state solution for Exercise 3 are reported in Section 6, utilizing the newly developed Parallel and Highly Innovative Simulation for INL Code System (PHISICS)/RELAP5-3D code suit. Finally, the lattice depletion models and results obtained for Phase III are compared in Section 7. The MHTGR-350 benchmark proved to be a challenging simulation set of problems to model accurately, and even with the simplifications introduced in the benchmark specification this activity is an important step in the code-to-code verification of modern prismatic VHTR codes. A final OECD/NEA comparison report will compare the Phase I and III results of all other international participants in 2014, while the remaining Phase II transient case results will be reported in 2015.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Widening the Scope of R-matrix Methods

A Consultant’s Meeting was held at the IAEA Headquarters, from 7 to 9 December 2015, to discuss the status of R-matrix codes currently used in calculations of charged-particle induced reaction cross sections at low energies. The ultimate goal was to initiate an international effort, coordinated by the IAEA, to evaluate charged-particle induced reactions in the resolved-resonance region. Participants reviewed the capabilities of the codes, the different implementations of R-matrix theory and translatability of the R-matrix parameters, the evaluation methods and suitable data formats for broader dissemination. The details of the presentations and technical discussions, as well as the actions that were proposed to achieve the goal of the meeting are summarized in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Phase equilibria of advanced technology uranium silicide-based nuclear fuel

The phases in uranium-silicide binary system were evaluated in regards to their stabilities, phase boundaries, crystal structures, and phase transitions. The results from this study were used in combination with a well assessed literature to optimize the U-Si phase diagram using the CALPHAD method. A thermodynamic database was developed, which could be used to guide nuclear fuel fabrication, could be incorporated into other nuclear fuel thermodynamic databases, or could be used to generate data required by fuel performance codes to model fuel behavior in normal or off-normal reactor operations. The U 3 Si 2 and U 3 Si 5 phases were modeled using the Compound Energy Formalism model with 3 sublattices to account for the variation in composition. The crystal structure used for the USi phase was the tetragonal with an I4/mmm space. Above 450°C, the U 3 Si 5 phase was modeled. The composition of the USi 2 phase was adjusted to USi 1.84 . The calculated invariant reactions and the enthalpy of formation for the stoichiometric phases were in agreement with experimental data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Structure of the Neutron with Quasi-Elastic Scattering from 3H and 3HE

The magnetic form factor characterizes the magnetic distribution inside the neutron and knowledge of it is essential for the understanding of the neutron structure. The E12-11-112 experiment aimed to measure the neutron magnetic form factor (GnM) from the 3H/3He cross sections ratio, in the Q2 range of 0.5 - 3 GeV2. Quasi-elastic (QE) electron scattering was used to probe nucleons on the nucleus of the mirror 3H and 3He nuclei, in Hall A at the Thomas Jefferson National Accelerator Facility (JLab). The use of the mirror nuclei ratio is a novel extraction that cancels several systematic uncertainties from the cross section effects in the ratio. The motivation of this measurement is the disagreement between the precision measurements among the Q2 range of 0.5 - 1 GeV2 in the worldwide data. A total of five Q2 points were taken between this region and four more were taken with a Q2>1 GeV2 in order to estimate the accuracy of the method. Ideally, the 3H/3He ratio should be enough to calculate the magnetic form factor, but due to nuclear effects, there will be a correction of up to 8 % depending on the Q2 value that has to be evaluated before the form factor extraction. The cross sections were measured with a point-to-point uncertainty of 3 - 4.5 %, and the ratios were also evaluated with an uncertainty of 1.5 - 3 %. Therefore, the preliminary studies of the Gn M are summarized, and from the present analysis, it can be concluded that the precision of the measurement in the region of interest will be of the order of 1.5%.

Santiesteban, Sandra↗

Sum-of-Fractions Methodology for Actinides in Water- and Polyethylene-Moderated and -Reflected Systems

Sum-of-fractions is a method intended to make sure a subcritical margin for aqueous solutions and slurries of fissionable isotopes exists. The method indicates that a system is subcritical if the sum of the ratios of the mass of each isotope (in a mixture) to its individual minimum subcritical mass limit is less than or equal to one. Historically, the basis of the sum-of-fractions has been derived from allowances given in the American National Standards Institute (ANSI)/ American Nuclear Society (ANS)-8.15-1981. However, the allowance was removed in ANSI/ANS-8.15-2014 due to a lack of technical basis. A methodology was developed to assess the validity of using the sum-of-fractions for water- or polyethylene-moderated systems for the following nuclides: 232 U, 233 U, 234 U, 235 U, 237 Np, 236 Pu, 238 Pu, 239 Pu, 240 Pu, 241 Pu, 242 Pu, 241 Am, 242 m Am, 243 Am, 242 Cm, 243 Cm, 244 Cm, 245 Cm, 246 Cm, 247 Cm, 249 Cf, and 251 Cf. The methodology uses available benchmark data for mixtures of 233 U, 235 U, and 239 Pu to establish the calculational margin, and a mass limit reduction to establish the margin of subcriticality. Water- or polyethylene-moderated and -reflected mixtures containing the nuclides are evaluated with the code system, SCALE 6.2.4. Including the calculational margin, subcritical mass limits for each nuclide were computed for optimally water- or polyethylene-moderated and fully reflected systems. These masses were used to create nuclide mixtures in which the sum of the mass to subcritical mass limit ratios is one. The various nuclide mixtures were modeled over a range of moderation and demonstrate the keff does not exceed the calculational margin. For additional assurance of subcriticality, a significant mass reduction is applied to each computed minimum critical mass of the nuclides without adequate benchmark data consistent with the method in ANSI/ANS-8.15-2014.

07 ISOTOPE AND RADIATION SOURCES↗

Development and Comparison of Purgeable Mercury Values in SRR Samples Measured by SRNL and Eurofins FGS

Savannah River Remediation (SRR) requested the development of mercury speciation capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins Frontier Global Sciences (FGS). This document reports on this method development work performed at SRNL as well as the comparative analyses conducted between the two laboratories. Development, optimization, and validation were undertaken at SRNL to produce a method for the species-specific analysis of dissolved gaseous mercury (DGM) in samples from SRR. It was determined that DGM present in SRR samples represented a combination of various soluble and volatile mercury species- and is thus referred to in this document as purgeable mercury. A method has been developed and analytically validated for the analysis of purgeable mercury in caustic nuclear waste. Using multivariate optimization, an efficient and sensitive method was produced. Total recovery of spiked purgeable mercury from deionized water was 99.4 ±10.6% and 91.6 ±14.9% from spiked high-activity tank waste samples. Calibration, by external calibration and standard addition calibration, maintained a mean accuracy of 101 ±5% and 99.9 ±1.7%, respectively. An interlaboratory comparison was performed between SRNL and Eurofins FGS in the co-analysis of three quarterly SRR Tank 50 samples. The statistical evaluations presented in this document support the following conclusions: for internal validation data, the two laboratories demonstrate biases of -4.3% for SRNL and 4.4% for Eurofins FGS, though neither are statistically significant at the 5% level. While the percent relative standard deviation for each of the laboratories is rather large (21.5% for SRNL and 18.4% for Eurofins FGS), there is no indication of a statistically significant difference between the two laboratories in the precision of these results. For the three sets of SRR quarterly Tank 50 samples, there is no indication of a statistically significant bias between the two laboratories at the 5% significance level. These results indicate that SRNL may provide data to the customer of statistically similar quality to Eurofins FGS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal scattering law of C 2 H 4 n : Integrating experimental data with DFT calculations

Improvements in determination of the thermal scattering law of moderator materials (measuring, calculating and validating) are important for accurate prediction of neutron thermalization in nuclear systems. In this paper a methodology for producing thermal scattering libraries from the experimental data for polyethylene C 2 H 4 n is discussed. Double differential scattering cross section (DDSCS) experiments were performed at the Spallation Neutron Source of Oak Ridge National Laboratory (SNS ORNL). New scattering kernel evaluations, based on phonon spectrum for C 2 H 4 n , are created using the NJOY2016 code. Two different methods were used: direct and indirect geometry neutron scattering at ARCS and SEQUOIA, and VISION instruments, respectively, where the phonon spectrum was derived from the dynamical structure factor S(Q, ω ) obtained from the measured DDSCS. In order to compare and validate the newly created library, the experimental setup was simulated using MCNP6.1. Compared with the current ENDF/B-VII.1, the resulting RPI C 2 H 4 n libraries improved both double differential scattering and total scattering cross sections. A set of criticality benchmarks containing C 2 H 4 n from HEU-MET-THERM resulted in an overall improved calculation of K eff , although the libraries should be tested against benchmarks more sensitive to C 2 H 4 n . The DFT + oClimax method is used and is shown to be most comprehensive method for analysis of moderator materials. Finally, the importance of DFT + oClimax method lies in the fact that it can be validated against all data measured at VISION, ARCS and SEQUOIA, and experimental total scattering cross section measurements.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

An {alpha}-cluster model for {sub {Lambda}}{sup 9}Be spectroscopy

An {alpha}-cluster model is applied to study low-lying spectrum of the {sub {Lambda}}{sup 9}Be hypernucleus. The three-body {alpha}{alpha}{Lambda} problem is numerically solved by the Faddeev equations in configuration space using phenomenological pair potentials. We found a set of the potentials that reproduces experimental data for the ground state (1/2{sup +}) binding energy and excitation energy of the 5/2{sup +} and 3/2{sup +} states, simultaneously. This set includes the Ali-Bodmer potential of the version 'e' for {alpha}{alpha} and modified Tang-Herndon potential for {alpha}{Lambda} interactions. The spin-orbit {alpha}{Lambda} interaction is given by modified Scheerbaum potential. Low-lying energy levels are evaluated applying a variant of the analytical continuation method in the coupling constant. It is shown that the spectral properties of {sub {Lambda}}{sup 9}Be can be classified as an analog of {sup 9}Be spectrum with the exception of several 'genuine hypernuclear states'. This agrees qualitatively with previous studies. The results are compared with experimental data and new interpretation of the spectral structure is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of Erosion/Corrosion Rates in Hanford Tank Farms Radioactive Waste Transfer System Pipelines

The twenty-eight double-shell underground radioactive waste storage tanks at the U. S. Department of Energy’s Hanford Site near Richland, WA are interconnected by the Waste Transfer System network of buried steel encased pipelines and pipe jumpers in below-grade pits. The pipeline material is stainless steel or carbon steel in 51 mm to 152 mm (2 in. to 6 in.) sizes. The pipelines carry slurries ranging up to 20 volume percent solids and supernatants with less than one volume percent solids at velocities necessary to prevent settling. The pipelines, installed between 1976 and 2011, were originally intended to last until the 2028 completion of the double-shell tank storage mission. The mission has been subsequently extended. In 2010 the Tank Operating Contractor began a systematic evaluation of the Waste Transfer System pipeline conditions applying guidelines from API 579-1/ASME FFS-1 (2007), Fitness-For-Service. Between 2010 and 2014 Fitness-for-Service examinations of the Waste Transfer System pipeline materials, sizes, and components were completed. In parallel, waste throughput histories were prepared allowing side-by-side pipeline wall thinning rate comparisons between carbon and stainless steel, slurries and supernatants and throughput volumes. The work showed that for transfer volumes up to 6.1E+05 m 3 (161 million gallons), the highest throughput of any pipeline segment examined, there has been no detectable wall thinning in either stainless or carbon steel pipeline material regardless of waste fluid characteristics or throughput. The paper describes the field and laboratory evaluation methods used for the Fitness-for-Service examinations, the results of the examinations, and the data reduction methodologies used to support Hanford Waste Transfer System pipeline wall thinning conclusions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of Erosion/Corrosion Rates in Hanford Tank Farms Radioactive Waste Transfer System Pipelines - 16395

The twenty-eight double-shell underground radioactive waste storage tanks at the U.S. Department of Energy's Hanford Site near Richland, WA are interconnected by the Waste Transfer System network of buried steel encased pipelines and pipe jumpers in below-grade pits. The pipeline material is stainless steel or carbon steel in 51 mm to 152 mm (2 in. to 6 in.) sizes. The pipelines carry slurries ranging up to 20 volume percent solids and supernatants with less than one volume percent solids at velocities necessary to prevent settling. The pipelines, installed between 1976 and 2011, were originally intended to last until the 2028 completion of the double-shell tank storage mission. The mission has been subsequently extended. In 2010 the Tank Operating Contractor began a systematic evaluation of the Waste Transfer System pipeline conditions applying guidelines from API 579-1/ASME FFS-1 (2007), Fitness-For- Service. Between 2010 and 2014 Fitness-for-Service examinations of the Waste Transfer System pipeline materials, sizes, and components were completed. In parallel, waste throughput histories were prepared allowing side-by-side pipeline wall thinning rate comparisons between carbon and stainless steel, slurries and supernatants and throughput volumes. The work showed that for transfer volumes up to 6.1 E+05 m{sup 3} (161 million gallons), the highest throughput of any pipeline segment examined, there has been no detectable wall thinning in either stainless or carbon steel pipeline material regardless of waste fluid characteristics or throughput. The paper describes the field and laboratory evaluation methods used for the Fitness-for-Service examinations, the results of the examinations, and the data reduction methodologies used to support Hanford Waste Transfer System pipeline wall thinning conclusions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Absolute determination of photoluminescence quantum efficiency using an integrating sphere setup

An integrating sphere-based setup to obtain a quick and reliable determination of the internal quantum efficiency of strongly scattering luminescent materials is presented. In literature, two distinct but similar measurement procedures are frequently mentioned: a “two measurement” and a “three measurement” approach. Both methods are evaluated by applying the rigorous integrating sphere theory. It was found that both measurement procedures are valid. Additionally, the two methods are compared with respect to the uncertainty budget of the obtained values of the quantum efficiency. An inter-laboratory validation using the two distinct procedures was performed. The conclusions from the theoretical study were confirmed by the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive microrheology of normal and cancer cells after ML7 treatment by atomic force microscopy

Mechanical properties of living cancer and normal thyroidal cells were investigated by atomic force microscopy (AFM). Cell mechanics was compared before and after treatment with ML7, which is known to reduce myosin activity and induce softening of cell structures. We recorded force curves with extended dwell time of 6 seconds in contact at maximum forces from 500 pN to 1 nN. Data were analyzed within different frameworks: Hertz fit was applied in order to evaluate differences in Young’s moduli among cell types and conditions, while the fluctuations of the cantilever in contact with cells were analyzed with both conventional algorithms (probability density function and power spectral density) and multifractal detrended fluctuation analysis (MF-DFA). We found that cancer cells were softer than normal cells and ML7 had a substantial softening effect on normal cells, but only a marginal one on cancer cells. Moreover, we observed that all recorded signals for normal and cancer cells were monofractal with small differences between their scaling parameters. Finally, the applicability of wavelet-based methods of data analysis for the discrimination of different cell types is discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗