Systematic study on the discharge product of Pt-based lithium oxygen batteries
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Proton exchange membrane fuel cells (PEMFCs) are leading candidates to decarbonize the transport sector, but widespread deployment will require improvements in lifetime, fuel economy and cost. Here we present the grooved electrode, an alternative electrode structure that enhances PEMFC performance and durability by coupling high ionomer (ion-conducting binder) content for improved H + transport with grooves for rapid O 2 transport. Grooved electrodes provide up to 50% higher performance than state-of-the-art conventional electrodes under standard operating conditions. Fuel cell diagnostics combined with multiphysics modelling demonstrate that grooved electrodes provide facile O 2 transport despite their high ionomer content, enabling improved reaction rate uniformity. Grooved electrodes also provide improved durability, with less performance loss after carbon corrosion compared with baseline electrodes. Machine learning analysis demonstrates the potential to further optimize grooved structures for next-generation PEMFCs with enhanced performance and durability, enabling smaller and cheaper fuel cell stacks with higher fuel efficiency.
Energy storage and conversion systems, including batteries, supercapacitors, fuel cells, solar cells, and photoelectrochemical water splitting, have played vital roles in the reduction of fossil fuel usage, addressing environmental issues and the development of electric vehicles. The fabrication and surface/interface engineering of electrode materials with refined structures are indispensable for achieving optimal performances for the different energy-related devices. Atomic layer deposition (ALD) and molecular layer deposition (MLD) techniques, the gas-phase thin film deposition processes with self-limiting and saturated surface reactions, have emerged as powerful techniques for surface and interface engineering in energy-related devices due to their exceptional capability of precise thickness control, excellent uniformity and conformity, tunable composition and relatively low deposition temperature. In the past few decades, ALD and MLD have been intensively studied for energy storage and conversion applications with remarkable progress. In this work, we give a comprehensive summary of the development and achievements of ALD and MLD and their applications for energy storage and conversion, including batteries, supercapacitors, fuel cells, solar cells, and photoelectrochemical water splitting. Moreover, the fundamental understanding of the mechanisms involved in different devices will be deeply reviewed. Furthermore, the large-scale potential of ALD and MLD techniques is discussed and predicted. Finally, we will provide insightful perspectives on future directions for new material design by ALD and MLD and untapped opportunities in energy storage and conversion.
Herein I propose a method to directly measure the space and time dependence of the pair field correlator of a pair density wave. The method is based on two separate ideas. First, I adopt a recently proposed solenoid insertion method to provide the momentum in a tunnel junction. Second, I suggest the use of optimal or overdoped Bi-2201 films as a tunneling electrode with a known charge ordering wave vector which can match the expected pair density wave wave vectors I wish to study. The method is applicable to both fluctuating and ordered states. Potential applications are to the proposed stripe pair density wave order in LBCO and the possible pair density wave fluctuations at finite temperature or in high magnetic field in underdoped YBCO as well as other members of the cuprate family.
To produce a compact and efficient particle accelerator, several different piezoelectric transformer configurations are evaluated for their applicability in this demanding application area. Using a derived 1-D model for three different electroding and mounting schemes, accelerator efficiency and gradient are optimized. In conclusion, it is shown that with some advancements in material yield strength and advanced bonding techniques, reaching 4 MeV/m with over 40% efficiency is possible.
P>The discovery of electrotrophs, microorganisms that can directly accept electrons from electrodes for the reduction of terminal electron acceptors, has spurred the investigation of a wide range of potential applications. To date, only a handful of pure cultures have been shown to be capable of electrotrophy, but this process has also been inferred in many studies with undefined consortia. Potential electron acceptors include: carbon dioxide, nitrate, metals, chlorinated compounds, organic acids, protons and oxygen. Direct electron transfer from electrodes to cells has many advantages over indirect electrical stimulation of microbial metabolism via electron shuttles or hydrogen production. Supplying electrons with electrodes for the bioremediation of chlorinated compounds, nitrate or toxic metals may be preferable to adding organic electron donors or hydrogen to the subsurface or bioreactors. The most transformative application of electrotrophy may be microbial electrosynthesis in which carbon dioxide and water are converted to multi-carbon organic compounds that are released extracellularly. Coupling photovoltaic technology with microbial electrosynthesis represents a novel photosynthesis strategy that avoids many of the drawbacks of biomass-based strategies for the production of transportation fuels and other organic chemicals. The mechanisms for direct electron transfer from electrodes to microorganisms warrant further investigation in order to optimize envisioned applications.
Carbon-based platinum group metal-free (PGM-free) catalysts for oxygen reduction reaction (ORR) have received increasing attention as potential candidates for low-cost fuel cell cathode catalysts. Mass-transport within the very thick catalyst layer (CL) presents a major challenge to further improve the fuel cell performance of PGM-free catalysts, which may be realized through the optimization of CL structure. Herein, we demonstrate that membrane electrode assemblies (MEAs) with not hot-pressed PGM-free cathode showed improved H 2 -air fuel cell performance in mass transport region when compared to MEAs prepared via hot-pressing technique. Further, the effects of the ionomer content and equivalent weight (EW) on fuel cell performance were systematically explored. We observed that an increase in ionomer content resulted in performance improvement in the kinetic region, while negatively affecting the performance in the mass transport region. The overall optimum fuel cell performance was achieved with an ionomer EW of 830 g mol -1 .
High ionic conductivity membranes can be used to minimize ohmic losses in electrochemical devices such as fuel cells, flow batteries, and electrolyzers. Very high hydroxide conductivity was achieved through the synthesis of a norbornene-based tetrablock copolymer with an ion-exchange capacity of 3.88 meq/g. The membranes were cast with a thin polymer reinforcement layer and lightly cross-linked with N,N,N',N'-tetramethyl-1,6-hexanediamine. The norbornene polymer had a hydroxide conductivity of 212 mS/cm at 80°C. Light cross-linking helped to control the water uptake and provide mechanical stability while balancing the bound (i.e. waters of hydration) vs. free water in the films. The films showed excellent chemical stability with <1.5% conductivity loss after soaking in 1 M NaOH for 1000 h at 80°C. The aged films were analyzed by FT-IR before and after aging to confirm their chemical stability. A H 2 /O 2 alkaline polymer electrolyte fuel cell was fabricated and was able to achieve a peak power density of 3.5 W/cm 2 with a maximum current density of 9.7 A/cm 2 at 0.15 V at 80°C. The exceptionally high current and power densities were achieved by balancing and optimizing water removal and transport from the hydrogen negative electrode to the oxygen positive electrode. High water transport and thinness are critical aspects of the membrane in extending the power and current density of the cells to new record values.
The postulated concept of low-temperature all-metal thick film electrodes is discussed. It is noted that the mechanical and metallurgical properties of the electrodes are excellent, but electrical parameters remain to be optimized.
A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image data are analyzed by software that implements the present machine-vision technique. This analysis results in the identification of cells that are "good" candidates for patch clamping (see figure). Once a "good" cell is identified, a patch clamp can be effected by an automated patchclamping apparatus or by a human operator. This technique has been shown to enable reliable identification of "good" and "bad" candidate cells for patch clamping. The ultimate goal in further development of this technique is to combine artificial-intelligence processing with instrumentation and controls in order to produce a complete "turnkey" automated patch-clamping system capable of accurately and reliably patch clamping cells with a minimum intervention by a human operator. Moreover, this technique can be adapted to virtually any cellular-analysis procedure that includes repetitive operation of microscope hardware by a human.
Si-based Li-ion capacitor has been developed and demonstrated. The results show it is feasible to improve both power density and energy density in this configuration. The applied current density impacts the power and energy density: low current favors energy density while high current favors power density. Active carbon has a better rate capability than Si. Next StepsFuture Directions. Si electrode needs to be further studied and improved. Further optimization of SiAC ratio and evaluation of its impact on energy density and power density.
State-of-the-art membrane-based electrolyzers such as proton exchange membrane electrolyzer cells, are costly, susceptible to degradation, and time-consuming for electrode evaluation and triple-phase boundary electrochemical reaction studies. Here, a simple convertible electrolyzer in membraneless and membrane-based modes is proposed. For the first time, this enables comprehensive investigations of water splitting with pure water, acidic and alkaline electrolytes in one cell. With the simple electrolyzer and high-speed visualization system, the influences of flow rate, electrolytes, concentration, and Nafion membrane on the oxygen evolution reactions (OERs), hydrogen evolution reactions (HERs) and electrolyzer performance are comprehensively investigated. Visualization results reveal that water splitting only occurred at the edge between the electrode and the Nafion membrane in pure water. However, they occurred on the whole electrode surface in alkaline and acidic electrolytes, indicating easily tunable reaction sites with the convertible electrolyzer. This demonstrates the feasibility of using the simple convertible electrolyzer for understanding the water splitting mechanism. The relation between electrolyte thickness and resistances with different electrolytes is also quantified. This research provides an insight for optimizing electrochemical devices while delivering an inexpensive and fast way for electrode evaluations and electrochemical reaction studies.
We present our new results from testing 15-mm-long virtual Frisch-grid CdZnTe detectors with a common-cathode readout for correcting pulse-height distortions. The array employs parallelepiped-shaped CdZnTe (CZT) detectors of a large geometrical aspect ratio, with two planar contacts on the top and bottom surfaces (anode and cathode) and an additional shielding electrode on the crystal's sides to create the virtual Frisch-grid effect. We optimized the geometry of the device and improved its spectral response. We found that reducing to 5 mm the length of the shielding electrode placed next to the anode had no adverse effects on the device's performance. At the same time, this allowed corrections for electron loss by reading the cathode signals to obtain depth information.
A radiation detector system that effectively solves the electron trapping problem by optimizing shielding of individual virtual Frisch-grid detectors in an array configuration with a common cathode.
Highlights: • The apatite, K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1), was synthesized using reaction solid. • The obtained apatite was used to determine mercury in seawater samples from Morocco. • The effect of doping sodium into apatite on physic-chemical parameters was studied. • The influence of the electrochemical variables was investigated to determine mercury. - Abstract: A new chemically modified electrode was synthesized for the determination of mercury(II) using differential pulse anodic stripping voltammetry (DPASV). The electrode was modified by lacunar apatite K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1) synthesized using solid reaction. These powders were crystallized in the hexagonal system, space group P6{sub 3}/m. The effect of sodium content on structural, thermodynamic and electrochemical properties of prepared apatite has been studied. Therefore, the best results was obtained using NaCaPb{sub 3}(PO{sub 4}){sub 3} (x = 1) as modifier of carbon paste electrode for the electrochemical detection of mercury(II). The later ions were preconcentrated on the surface of the modified electrode and oxidized at 0.06 V vs. Ag/AgCl. The electroanalytical procedure comprises of two steps: the chemical accumulation of the analyte under open-circuit conditions followed by the electrochemical detection of the preconcentrated species using differential pulse voltammetry. The different parameters that govern the two steps were optimized. A linear response was obtained in the concentration range from 1.0 mol L{sup −1} × 10{sup −4} mol L{sup −1} to 2.0 mol L{sup −1} × 10{sup −7} mol L{sup −1} Hg(II) after activation of the electrode surface under the optimized conditions. The standard deviation was evaluated in a high and low concentration of mercury(II). The values obtained for seven consecutive measurements were 1.24% and 5.07% of 1.0 mol L{sup −1} × 10{sup −4} mol L{sup −1} and 5.0 mol L{sup −1} × 10{sup −6} mol L{sup −1} mercury(II) solutions respectively. The detection limit and quantification limit for mercury(II), calculated from nine times standard deviation of blank/slope of the calibration graph, were 1.086 mol L{sup −1} × 10{sup −8} mol L{sup −1} and 3.62 mol L{sup −1} × 10{sup −8} mol L{sup −1}, respectively. The proposed chemically modified electrode was applied to determine mercury(II) in seawater samples.
We present a systematic study on the effects of electrodeposition parameters on the photoelectrochemical properties of Cu{sub 2}O. The influence of deposition variables (temperature, pH, and deposition current density) on conductivity has been widely explored in the past for this semiconductor, but the optimization of the electrodeposition process for the photoelectrochemical response in aqueous solutions under AM 1.5 illumination has received far less attention. In this work, we analyze the photoactivity of Cu{sub 2}O films deposited at different conditions and correlate the photoresponse to morphology, film orientation, and electrical properties. The photoelectrochemical response was measured by linear sweep voltammetry under chopped simulated AM 1.5 illumination. The highest photocurrent obtained was -2.4 mA cm{sup -2} at 0.25 V vs RHE for a film thickness of 1.3 {micro}m. This is the highest reported value reached so far for this material in an aqueous electrolyte under AM 1.5 illumination. The optical and electrical properties of the most photoactive electrode were investigated by UV-vis spectroscopy and electrochemical impedance, while the minority carrier lifetime and diffusion length were measured by optical-pump THz-probe spectroscopy.
In this paper, a fully coupled analytical model between elastodynamics with micromagnetics is used to study the switching energies using voltage induced mechanical bending of a magnetoelastic bit. The bit consists of a single domain magnetoelastic nano-ellipse deposited on a thin film piezoelectric thin film (500 nm) attached to a thick substrate (0.5 mm) with patterned electrodes underneath the nano-dot. A voltage applied to the electrodes produces out of plane deformation with bending moments induced in the magnetoelastic bit modifying the magnetic anisotropy. To minimize the energy, two design stages are used. In the first stage, the geometry and bias field (H{sub b}) of the bit are optimized to minimize the strain energy required to rotate between two stable states. In the second stage, the bit's geometry is fixed, and the electrode position and control mechanism is optimized. The electrical energy input is about 200 (aJ) which is approximately two orders of magnitude lower than spin transfer torque approaches.
An electrostatic compact analyzer for obtaining the energy spectrum and for detecting simultaneously charged particles in a wide energy range, which is especially important for fast processes in various materials, has been proposed and designed. The energy analyzer consists of an outer conical electrode with closed end faces, which is cut into parts and fed in accordance with the law of odd numbers, and an grounded inner electrode on the surface of which charged particle beams with a wide energy range are focused. To increase the sharpness of low-energy beam focusing, an auxiliary, very small conical electrode is introduced. In spite of the small energy dispersion factor, the optimal regime of operation of the proposed analyzer with energy resolution not worse than 1% has been found.