Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASTIC SCINTILLATION DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

504 records · Page 28

Simultaneous measurement of organic scintillator response to carbon and proton recoils

Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from neutron interactions with carbon nuclei are scarce. Demonstrate a new approach for the simultaneous measurement of the proton and carbon light yield of organic scintillators. Provide new carbon light yield data for the EJ-309 liquid and EJ-204 plastic organic scintillators. A 33-MeV 2 H + beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory was impinged upon a 3-mm-thick Be target to produce a high-flux, broad-spectrum neutron beam. The double time-of-flight technique was extended to simultaneously measure the proton and carbon light yields of the organic scintillators, wherein the light output associated with the recoil particle was determined using np and nC elastic scattering kinematics. The proton and carbon light yield relations of the EJ-309 liquid and EJ-204 plastic organic scintillators were measured over a recoil energy range of approximately 0.3 to 1 MeV and 2 to 5 MeV, respectively, for EJ-309, and 0.2 to 0.5 MeV and 1 to 4 MeV, respectively, for EJ-204. Furthermore, these data provide new insight into the ionization quenching effect in organic scintillators and key input for simulation of the response of organic scintillators for both basic science and a broad range of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a lab-scale, high-resolution, tube-generated X-ray computed-tomography system for three-dimensional (3D) materials characterization

The design and construction of a modular high resolution X-ray computed tomography (XCT) system is highlighted in this paper. The design approach is detailed for meeting a specified set of instrument performance goals tailored towards experimental versatility and high resolution imaging. The XCT tool is unique in the detector and X-ray source design configuration, enabling control in the balance between detection efficiency and spatial resolution. The system package is also unique: The sample manipulation approach implemented enables a wide gamut of in situ experimentation to analyze structure evolution under applied stimulus, by optimizing scan conditions through a high degree of controllability. The component selection and design process is detailed: Incorporated components are specified, custom designs are shared, and the approach for their integration into a fully functional XCT scanner is provided. Custom designs discussed include the dual-target X-ray source cradle which maintains position and trajectory of the beam between the two X-ray target configurations with respect to a scintillator mounting and positioning assembly and the imaging sensor, as well as a novel large-format X-ray detector with enhanced adaptability. The instrument is discussed from an operational point of view, including the details of data acquisition and processing implemented for 3D imaging via micro-CT. The performance of the instrument is demonstrated on a silica-glass particle/hydroxyl-terminated-polybutadiene (HTPB) matrix binder PBX simulant. Post-scan data processing, specifically segmentation of the sample's relevant microstructure from the 3D reconstruction, is provided to demonstrate the utility of the instrument. - Highlights: • Custom built X-ray tomography system for microstructural characterization • Detector design for maximizing polychromatic X-ray detection efficiency • X-ray design offered for maximizing X-ray flux with respect to imaging resolution • Novel lab-scale XCT data acquisition and data processing methods • 3D characterization of glass-bead mock plastic-bonded-explosive stimulant.

36 MATERIALS SCIENCE↗

SU-F-T-445: Effect of Triaxial Cables and Microdetectors in Small Field Dosimetry

Purpose: Advances in radiation treatment especially with smaller fields used in SRS, Gamma knife, Tomotherapy, Cyberknife, and IMRT, require a high degree of precision especially with microdetectors for small field dosimetry (Das et al, Med Ph, 35, 206, 2008; Alfonso et al, Med Phys, 35, 5179, 2008). Due to small signal, the triaxial cable becomes critical in terms of signal to noise ratio (SNR) which is studied with microdetectors. Methods: Six high quality triaxial cables, 9.1 meters long from different manufacturers without any defects were acquired along with 5 most popular microdetectors (microdiamond, plastic scintillators, SRS-diode, edge-diode and pinpoint). A dedicated electrometer was used for each combination except W1 which has its own supermax electrometer. A 6MV photon beam from Varian True beam with 100 MU at a 600 MU/min was used. Measurements were made at a depth of 5 cm in water phantom. Field sizes were varied from 0.5 cm to 10 cm square fields. Readings were taken with combination of cables and microdetectors. Results: Signal is dependent on the quality of the connectors, cables and types of microdetector. The readings varied from nC to pC depending on the type of microdetector. The net signal, S, (Sc-Sn), where Sc is signal with chamber and Sn is without chamber is a linear function of sensitive volume, v; (S = α+β•V), where α and β are constants. The standard deviation (SD) in 3 sets of reading with each combination of cable-detector was extremely low <0.02%. As expected the SD is higher in small fields (<3cm). Maximum estimated error was only ±0.2% in cables-detector combinations. Conclusion: The choice of cables has relatively small effect (±0.2%) with microdosimeter and should be accounted in overall error estimation in k value that is needed to convert ratio of reading to dose in small field dosimetry.

60 APPLIED LIFE SCIENCES↗

PVC extrusion development and production for the NOvA neutrino experiment

We have produced large and highly-reflective open-cell PVC extrusions for the NOvA neutrino oscillation experiment. The extrusions were sealed, instrumented, assembled into self-supporting detector blocks, and filled with liquid scintillator. Each Far Detector block stands 15.7 m high, is 15.7 m wide and 2.1 m thick. More than 22,000 extrusions were produced with high dimensional tolerance and robust mechanical strength. This paper provides an overview of the NOvA Far Detector, describes the preparation of the custom PVC powder, and the making of the extrusions. As a result, quality control was a key element in the production and is described in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of shashlik electromagnetic calorimeter prototype for SoLID

A shashlik electromagnetic calorimeter will be produced in Hall A of Jefferson Laboratory for Solenoidal large Intensity Device (SoLID) to measure the energy deposition of electrons and hadrons, and to provide particle identification after the energy of the accelerator was upgraded to 12 GeV. Tsinghua University is the member of Hall A collaboration in charge of development and production of the large shashlik electromagnetic calorimeter of SoLID. One module of that calorimeter is composed by 194 layers. Each layer consists of a 1.5 mm thick plastic scintillator put on top of a 0.5 mm thick lead plate. Scintillation light is read out by wave-length shifter fibers penetrating through the calorimeter modules longitudinally along the direction of flight of the impact particle. This paper describes the design and construction of that module, as well as a few optimization studies meant to improve its performance. A detailed Geant4 simulation also shows that an energy resolution of 5%/√ E (GeV) and a good containment for electromagnetic showers can be achieved, as well as some basic electron identification. In conclusion, a prototype of that module will be tested soon with an electron beam at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-E-18A-08: Towards a Next-Generation Electronic Portal Device for Simultaneous Imaging and Dose Verification in Radiotherapy

Purpose: This work forms part of an ongoing study to develop a next-generation electronic portal imaging device (EPID) for simultaneous imaging and dose verification in radiotherapy. Monte Carlo (MC) simulations were used to characterize the imaging performance of a novel EPID that has previously been demonstrated to exhibit a water-equivalent response. The EPID ' s response was quantified in several configurations and model parameters were empirically validated against experimental measurements. Methods: A MC model of a novel a-Si EPID incorporating an array of plastic scintillating fibers was developed. Square BCF-99-06A scintillator fibers with PMMA cladding (Saint-Gobain Crystals) were modelled in a matrix with total area measuring 150×150 mm{sup 2}. The standard electromagnetic and optical physics Geant4 classes were used to simulate radiation transport from an angled slit source (6 MV energy spectrum) through the EPID and optical photons reaching the photodiodes were scored. The prototype's modulation transfer function (MTF) was simulated and validated against experimental measurements. Several optical transport parameters, fiber lengths and thicknesses of an air gap between the scintillator and photodiodes were investigated to quantify their effects on the prototype's detection efficiency, sensitivity and MTF. Results: Simulated EPID response was more sensitive to variations in geometry than in the optical parameters studied. The MTF was particularly sensitive to the introduction of a 0.5–1.0 mm air gap between the scintillator and photodiodes, which lowered the MTF relative to that simulated without the gap. As expected, increasing the fiber length increased the detector efficiency and sensitivity while decreasing the MTF. Conclusion: A model of a novel water-equivalent EPID has been developed and benchmarked against measurements using a physical prototype. We have demonstrated the feasibility of this new device and are continuing to optimize the design to achieve an imaging response that warrants the development of a next-generation prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The use of artificial neural networks in PVT-based radiation portal monitors

Polyvinyl toluene (PVT) based gamma-ray scintillation detectors are cost effective for use in radiation portal monitors (RPMs) applied to screening for illicit radioactive materials at international border crossings. While PVT detectors provide good sensitivity in detecting the presence of radioactive materials, they provide poor spectral resolution, limiting their ability to identify the isotopic content of the source of radiation. Thus using only total-spectrum or gross-count alarm algorithms, PVT-based RPMs cannot distinguish innocent materials that contain low-levels of normally occurring radioactivity from special nuclear materials of concern. To reduce the number of “nuisance” alarms produced in PVT-based RPMs by innocent materials, algorithms that analyze spectra from PVT detectors must be optimized to make use of the limited information contained in their energy spectra. This paper discusses how artificial neural networks (ANNs) can be used in such an analysis. The objective was to reduce the nuisance/false alarm probability while maintaining high detection probabilities, thus allowing gross count alarm thresholds to be raised without loss of performance and sensitivity to radioactive materials of interest. The spectra used in this study were obtained from actual PVT-based RPM data, and included cases where simulated spectra were inserted into the measured spectra. This paper also includes an analysis of spectral channel importance and shows evaluations of two methods used to rebin energy spectra into smaller sets. The results show that ANNs can be used with RPMs to reduce nuisance alarms. The algorithms described can be used in analyzing PVT spectra, and potentially sodium iodide spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanostructured Lanthanum Halides and CeBr3 for Nuclear Radiation and Detection

Scintillator materials are used to detect, and in some cases identify, gamma rays. Higher performance scintillators are expensive, hard to manufacture, fragile, and sometimes require liquid nitrogen or cooling engines. But whereas lower-quality scintillators are cheap, easy to manufacture, and more rugged, their performance is lower. At issue: can the desirable qualities of high-and low-performance scintillators be combined to achieve better performance at lower cost? Preliminary experiments show that a LaF{sub 3}:Ce oleic acid-based nanocomposite exhibits a photopeak when exposed to {sup 137}Cs source gamma-radiation. The chemical synthesis of the cerium-doped lanthanum halide nanoparticles are scalable and large quantities of material can be produced at a time, unlike typical crystal growth processes such as the Bridgeman process. Using a polymer composite (Figure 1), produced by LANL, initial measurements of the unloaded and 8% LaF{sub 3}:Ce-loaded sample have been made using {sup 137}Cs sources. Figure 2 shows an energy spectrum acquired for CeF{sub 3}. The lighter plot is the measured polymer-only spectrum and the black plot is the spectrum from the nanocomposite scintillator. As the development of this material continues, the energy resolution is expected to improve and the photopeak-to-Compton ratio will become greater at higher loadings. These measurements show the expected Compton edge in the polymer-only sample, and the Compton edge and photo-peak expected in the nanophosphor composites that LANL has produced. Using a porous VYCORR with CdSe/ZnS core shell quantum dots, Letant has demonstrated that he has obtained signatures of the 241Am photopeak with energy resolution as good at NaI (Figure 3). We begin with the fact that CeBr{sub 3} crystals do not have a self-activity component as strong as the lanthanum halides. The radioactive 0.090% {sup 138}La component of lanthanum leads to significant self-activity, which will be a problem for very large detector volumes. Yet a significant strength of the nanostructure detector concept is the ability to create extremely large detector volumes by mixing nanoparticles into a transparent matrix. This would argue for use of nanoparticles other than lanthanum halides. Nanocomposites are easy to prepare; it is much less costly to use nanocomposites than to grow large whole crystals of these materials. The material can be fabricated at an industrial scale, further reducing cost. This material potentially offers the performance of $300/cc material (e.g., lanthanum bromide) at a cost of $1/cc. Because the material acts as a plastic, it is rugged and flexible, and can be made in large sheets, increasing the sensitivity of a detector using it. It would operate at ambient temperatures. Very large volumes of detector may be produced at greatly reduced cost, enhancing the non-proliferation posture of the nation for the same dollar value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation characteristics of the EJ-299-02H scintillator

Here a study of the dead layer thickness and quenching factor of a plastic scintillator for use in ultracold neutron (UCN) experiments is described. Alpha spectroscopy was used to determine the thickness of a thin surface dead layer to be 630 ± 110 nm. The relative light outputs from the decay of 241 Am and Compton scattering of electrons were used to extract Birks’ law coefficient, yielding a kB value of 0.087 ± 0.003 mm/MeV, consistent with some previous reports for other polystyrene-based scintillators. The results from these measurements are incorporated into the simulation to show that an energy threshold of (∼9 keV) can be achieved for the UCNProBe experiment. This low threshold enables high beta particle detection efficiency and the indirect measurement of UCN. The ability to make the scintillator deuterated, accompanied by its relatively thin dead layer, gives rise to unique applications in a wide range of UCN experiments, where it can be used to trap UCN and detect charged particles in situ.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Directional Stand-off Detection of Fast Neutrons and Gammas Using Angular Scattering Distributions

We have investigated the response of a DoubleScatter Neutron Spectrometer (DSNS) for sources at long distances (gr than 200 meters). We find that an alternative method for analyzing double scatter data avoids some uncertainties introduced by amplitude measurements in plastic scintillators.Time of flight is used to discriminate between gamma and neutron events, and the kinematic distributions of scattering angles are assumed to apply. Non-relativistic neutrons are most likely to scatter at 45°, while gammas with energies greater than 2 MeV are most likely to be forward scattered. The distribution of scattering angles of fission neutrons arriving from a distant point source generates a 45° cone, which can be back-projected to give the source direction. At the same time, the distribution of Compton-scattered gammas has a maximum in the forward direction, and can be made narrower by selecting events that deposit minimal energy in the first scattering event. We have further determined that the shape of spontaneous fission neutron spectra at ranges gr than 110 m is still significantly different from thecosmic ray background.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗

Optical observation of energy loss distribution and practical range of positrons from a {sup 18}F water solution in a water-equivalent phantom

The energy loss distribution of {beta}{sup +} particles is closely related to their maximum penetration depth distribution and annihilation point distribution. The latter is of practical importance for positron emission tomography. Experimental data related to the energy loss distribution are important for comprehensive validation of physics and simulation models of {beta}{sup +} interactions. In this paper the authors present a new experimental approach that allows them to visually observe the {beta}{sup +} energy loss distribution of a solution of nuclear medicine radioisotopes in a plastic scintillator using an optical camera. The authors also report a set of the first experimental results. A water solution of {sup 18}F was localized in a small hole in a plastic scintillator (BC430). Optical imaging of the scintillator yielded visual images of the energy loss distribution with a submillimeter resolution. The radial dependence in the energy distribution was quantitatively measured by analysis of the images, and exponential fitting parameters were obtained. The authors observed that the results of Monte Carlo simulation with EGS5 (version 1.0.2) and GEANT4 (version 4.9.01.p01) were consistent with those obtained experimentally. The results of the Monte Carlo simulation indicated that for a linear scale, the energy loss distribution in the scintillator was approximately the same as that in water, and the relative shape of the energy loss distribution was close to those of the maximum penetration depth distribution and annihilation point distribution. This paper also presents discussions about the further possibilities of this optical imaging approach. Thus, optical observation of the {beta}{sup +} energy loss distribution in a scintillator is a promising technique for visual and quantitative experimental studies of {beta}{sup +} emission from a solution of radioisotopes that are used in nuclear medicine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of tritium with plastic scintillator surface improvement with plasma treatment

Tritium is usually measured by using a liquid scintillation counter. However, liquid scintillator used for measurement will become radioactive waste fluid. To solve this issue, we have developed a method of measuring tritium samples with plasma-treated plastic scintillator (PS)sheets (Plasma method). The radioactive sample is held between 2 PS sheets and the whole is enclosed in a a low-potassium glass vial. With the Plasma method of 2-min plasma treatment, we have obtained measurement efficiency of 48 ± 2 % for 2 min measurement of tritium except for tritiated water. The plasma treatment makes the PS surface rough and hydrophilic which contributes to improve the contact between tritium and PS. On the other hand, it needed almost 6 hours to obtain constant measurement efficiency. The reason was that the dry-up handling in the vial needed longer time to vaporize H{sub 2}O molecules than in the air. We tried putting silica gel beads into vials to remove H{sub 2}O molecules from PS sheet surface quickly. The silica gel beads worked well and we got constant measurement efficiency within 1-3 hours. Also, we tried using other kinds of PS treated with plasma to obtain higher measurement efficiencies of tritium samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GIOVE, a shallow laboratory Ge-spectrometer with 100 μBq/kg sensitivity

A new germanium gamma spectrometer called GIOVE (Germanium spectrometer with Inner and Outer Veto) has been set up at the underground/shallow laboratory (15 m w.e.) of MPI-K. Its double plastic scintillator veto system and neutron moderation interlayer lower the background by more than one order of magnitude compared to the other existing spectrometer at this facility. The integral (40-2700 keV) background rate of about 290 counts (day kg){sup −1} is just a factor 4 to 8 above that of the GeMPI spectrometers operated at LNGS (3800 m w.e.) and thus proves that even under shallow overburden sub mBq/kg sensitivities are achievable. Extended material screening and neutron attenuation studies preceded the final design of the spectrometer. The technical realization of the spectrometer is described in detail with special emphasis on the inner veto system. For its optimisation a simulation model was developed for light collection on small low activity PMT’s under various geometrical conditions. Radon suppression is accomplished by employing a gas tight sample container and a nitrogen flushed glove-box system with an airlock. The active volume of the crystal was modelled by absorption scanning measurements and Monte Carlo simulations. The complete shield is implemented in a Geant4 based simulation framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution 3D-printed plastic scintillators with tertiary dye

Additive manufacturing offers efficient production of plastic scintillators with nontrivial geometries using vat polymerization, allowing fabrication of geometries which would be difficult or even impossible to produce using conventional subtractive manufacturing. This work presents a novel photocurable scintillator formula that includes coumarin 450 as a tertiary dye to enable high-resolution 3D printing via the manipulation of the 405 nm cure light. Bulk photocured and 3D printed (with and without tertiary dye) samples were compared through observational assessment and spectral response. All samples showed pulse shape discrimination between neutron and gamma events. Inclusion of the tertiary dye has minimal impact on emission spectrum and light output, but significant impact on print resolution as shown by comparison of printed high-complexity geometries and feature resolution test objects. With the use of a cure-limiting dye, unsupported features — such as freestanding pillars — were resolvable down to 0.7 mm. Even finer resolution at or below 0.1 mm was achieved in fully supported, integrated structures printed with off-the-shelf 405 nm desktop 3D printer. Scintillators demonstrated a light output up to 50% of EJ-200 with a PSD figure of merit up to 1.35 at 0.9–1.1 MeVee.

36 MATERIALS SCIENCE↗

The MUSE Target Chamber Post Veto

The Muon Scattering Experiment (MUSE) was developed to address the proton radius puzzle through simultaneous electron–proton and muon-proton scattering using the Paul Scherrer Institute’s πM1 secondary beamline. MUSE uses a large-solid-angle, non-magnetic spectrometer to detect beam particles scattering from a liquid hydrogen cell contained within a vacuum chamber. Due to the large scattering windows, the structural integrity of the chamber is supported by posts located at small scattering angles. While out of the acceptance, particles in the tails of the beam distribution can strike these posts, causing a significant trigger background. We describe the design and performance of the Target Chamber Post Veto (TCPV) detector installed inside the vacuum chamber to remove these background events at the trigger level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗