Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance, Reliability, Design, Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Overcoming challenges to support US resumption of high specific activity cobalt-60

Domestic production of high specific activity 60 Co was halted after a target rupture in 2012 at the Advanced Test Reactor (ATR). The Isotope Program (IP) within the US Department of Energy (DOE) Office of Science tasked a multilaboratory team of researchers and managers from Oak Ridge and Idaho National Laboratories with the redesign the radioisotope capsule. The objective of this effort was to create a more robust and reliable design, compared to the pre-2012 target. The team successfully completed this task to produce the DOE-IP cobalt (Co) production capsule design. Furthermore, 66 capsules were successfully fabricated by Oak Ridge National Laboratory (ORNL) and delivered to Idaho National Laboratory (INL) for irradiation in the ATR between January 2014 and October 2016. This paper describes the efforts of the team to prepare and disposition the two initial DOE-IP Co production capsules that were processed in March 2020. These efforts include performing accurate production predictions, experimentally validating predictions with assay measurements, shipping with the Orano-furnished Battelle Energy Alliance Research Reactor shipping package, and disassembling capsules at the isotope vendor site.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computational Framework for Machine-Learning-Enabled 13 C Fluxomics

13 C metabolic flux analysis (MFA) has emerged as a powerful tool for synthetic biology. This optimization-based approach suffers long computation time and unstable solutions depending on the initial guess. Here, we develop a machine-learning-based framework for 13 C fluxomics. Specifically, training and test data sets are generated by metabolic network decomposition and flux sampling, in which flux ratios at metabolic nodes and simulated labeling patterns of metabolites are used as training targets and features, respectively. To improve prediction accuracy and simplify the model, automated processes are developed for flux ratio selection based on solvability and feature screening based on importance. We found that predictive performance can be significantly improved using both amino acids and central carbon metabolites in comparison with amino acids alone. Together with measured external fluxes, the predicted flux ratios determine the mass balance system, yielding global flux distributions. This approach is validated by flux estimation using both simulated and experimental data in comparison with canonical 13 C MFA. The approach represents a reliable fluxomics method readily applicable to high-throughput metabolic phenotyping, which highlights the advances of intelligent learning algorithms in synthetic biology, specifically in the Test and Learn stage of the Design-Build-Test-Learn cycle.

13C metabolic flux analysis↗

Cell-level reliability testing procedures for CIGS photovoltaics

The reliability of photovoltaics is commonly studied at the module level. Many reliability problems originate from module attributes, such as metal interconnections to cells, junction boxes. However, significant work in reliability can also be done prior to module design. Testing for reliability earlier in the research cycle increases the probability of avoiding common module reliability problems before cell changes are implemented on a large scale. Cell-level reliability studies can thus lower the rates of module failures in the field and provide confidence to investors that new technologies will perform as advertised. This report summarizes how we investigated three reliability concerns in Cu(In,Ga)Se 2 (CIGS) photovoltaics at the cell level: metastability, shading-induced damage, and potential-induced degradation (PID). We find that examining these concerns required developing robust measurement protocols including the fabrication of novel testing structures. This information will allow readers to incorporate sound metrics for investigating reliability phenomena and aid their studies of cell and module reliability improvements.

14 SOLAR ENERGY↗

Lunar landing and launch facilities (Complex 39L): Guidance systems and propellant systems

After a general, overall definition of Complex 39L during the previous two years, the 1988-89 projects were chosen to focus on more specific aspects, specifically, guidance systems and propellant systems. Six teams or subtasks were formulated: cascade refrigeration for boil-off recovery of cryogenic storage vessels; lunar ground-based radar system to track space vehicles; microwave altimeter for spacecraft; development of a computational model for the determination of lunar surface and sub-surface temperatures; lunar cryogenic facility for the storage of fuels; and lunar lander fuel inventory tent for the storage of cryogenic vessels. At the present time, a cascade refrigeration system for a cryogenic boil-off recovery system has been designed. This is to serve as a baseline system. The ground-based tracking system uses existing technology to implement a reliable tracking radar for use on the lunar surface. A prototype has been constructed. The microwave altimeter is for use on lunar landers. It makes use of the Doppler effect to measure both altitude and the vertical velocity component of the spacecraft. A prototype has been constructed. A computational model that predicts the spatial and temporal temperature profiles of the lunar subsurface was formulated. Propellant storage vessels have been designed. A support for these vessels which minimizes heat leaks was also designed. Further work on the details of the Fuel Inventory Tent (FIT) was performed. While much design work on the overall Complex 39L remains to be done, significant new work has been performed in the subject areas.

Source record↗

Credible Software and Simulation Uncertainty

The utility of software primarily depends on its reliability and performance; whereas, its significance depends solely on its credibility for intended use. The credibility of simulations confirms the credibility of software. The level of veracity and the level of validity of simulations determine the degree of credibility of simulations. The process of assessing this credibility in fields such as computational mechanics (CM) differs from that followed by the Defense Modeling and Simulation Office in operations research. Verification and validation (V&V) of CM simulations is not the same as V&V of CM software. Uncertainty is the measure of simulation credibility. Designers who use software are concerned with management of simulation uncertainty. Terminology and concepts are presented with a few examples from computational fluid dynamics.

Mehta, Unmeel B.↗

Improvements in DC Current-Ioltage (I-V) Characteristics of n-GaN Schottky Diode using Metal Overlap Edge Termination

Practical design of GaN Schottky diodes incorporating a field plate necessitates an understanding of how the addition of such plate affects the diode performance. In this paper, we investigated the effects on DC current-voltage (I-V) characteristics of n-GaN schottky diode by incorporating metal overlap edge termination. The thickness of the oxide film varies from 0.001 to 1 micron. Two-dimensional Atlas/Blaze simulations revealed that severe electric field crowding across the metal semiconductor contact will cause reliability concern and limit device breakdown voltage. DC current-voltage (I-V) measurements indicate that the forward currents are higher for thinner oxide film schottky diodes with metal overlap edge termination than those of unterminated schottky diodes. The forward current increased due to formation of an accumulation layer underneath the oxide layer. Extending the field plate to beyond periphery regions of schottky contact does not result in any significant increase in forward current. The new techniques of ramp oxide metal overlap edge termination have been implemented to increase the forward current of n-GaN schottky diode. In reverse bias, breakdown voltage increased with edge termination oxide up to a certain limit of oxide thickness.

36 MATERIALS SCIENCE↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

DPF Test Conditions: FY 2016

A Neutron Diagnosed Subcritical Experiment (NDSE) is designed to quantitatively measure the reactivity of a subcritical (k eff <1.0) plutonium experiment and thereby improve our understanding of primary performance in the absence of underground nuclear testing. Successful implementation of this diagnostic requires a short, intense burst of neutrons be delivered to the fissile assembly at a precise time during a plutonium implosion. Monte Carlo particle transport simulations of representative subcritical experiments have been performed to establish the pulse shape, flux, and timing requirements for the NDSE neutron source. Additional requirements have also been established for detector sensitivity, acceptable background levels, and total diagnostic reliability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an automated high-temperature valveless injection system for online gas chromatography

A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introduction using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week -1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.

Kreisberg, N. M.↗

Reliability estimation procedures and CARE: The Computer-Aided Reliability Estimation Program

Ultrareliable fault-tolerant onboard digital systems for spacecraft intended for long mission life exploration of the outer planets are under development. The design of systems involving self-repair and fault-tolerance leads to the companion problem of quantifying and evaluating the survival probability of the system for the mission under consideration and the constraints imposed upon the system. Methods have been developed to (1) model self-repair and fault-tolerant organizations; (2) compute survival probability, mean life, and many other reliability predictive functions with respect to various systems and mission parameters; (3) perform sensitivity analysis of the system with respect to mission parameters; and (4) quantitatively compare competitive fault-tolerant systems. Various measures of comparison are offered. To automate the procedures of reliability mathematical modeling and evaluation, the CARE (computer-aided reliability estimation) program was developed. CARE is an interactive program residing on the UNIVAC 1108 system, which makes the above calculations and facilitates report preparation by providing output in tabular form, graphical 2-dimensional plots, and 3-dimensional projections. The reliability estimation of fault-tolerant organization by means of the CARE program is described.

Mathur, F. P.↗

An Approach to Studying the Reliability of Microgravity Experiments

The identification of key factors that influence the nonsuccess of experiments conducted under microgravity conditions will aid in the planning, design, and implementation of future space shuttle experiments, as well as other microgravity experiments (i.e., experiments conducted on the space station). Similarly, knowledge of the experiments' reliability will assist in forecasting the success of forthcoming experiments. Since a relatively large number of space shuttle experiments have been conducted to date, a substantial pool of data exists for assessing the possible causes or factors which influence experiment nonsuccesses. This report details the task being undertaken at NASA Lewis Research Center (LeRC) to measure the space shuttle experiments' nonsuccess trends and identify causes that significantly affect their performance. It addresses the activities associated with correlating experiment macro-factors with experiment nonsuccesses. The development and implementation of a microgravity database to be used for tracking and correlating experiment nonsuccess factors, as well as the criteria for measuring experiment success and nonsuccess, are also discussed.

Thaggard, Michael↗

Recent Advances in LIBS for Real-Time Detection of Silicone Contaminants on CFRP Surfaces

Laser induced breakdown spectroscopy (LIBS) is a materials characterization technique that has been advanced and refined to provide in situ, real-time quality control of carbon fiber reinforced polymer (CFRP) surfaces. As part of an effort to improve process control for adhesive bonding, a LIBS system was designed and assembled at NASA Langley Research Center (LaRC) to enable detection of ultralow concentrations of silicone contamination on CFRP adherends. The LIBS instrument provides high sensitivity detection and quasi-nondestructive surface characterization of CFRP adherends prior to adhesive bonding. This review focuses on the advancements at LaRC using LIBS as a quality control tool for the detection of silicone contaminants for improved adhesive bonding reliability of CFRP materials. This work describes how the LIBS technique was advanced by analyzing the laser parameters, studying the laser-matter interactions, and performing time-resolved measurements to determine the optimal plasma conditions for elemental detection. In addition, LIBS results were compared to X-ray photoelectron spectroscopy data to enable quantitative analysis from analytical calibration curves. Examples are shown of how to perform surface mapping of silicone contamination. Finally, a brief discussion is also presented on LIBS instrumentation, recommendations for laser parameters and instrumentation components, and LIBS technique maturity.

Surface characterization, Carbon fiber reinforced ↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Technical Letter Report Assessment of Ultrasonic Phased Array Inspection Method for Welds in Cast Austenitic Stainless Steel Pressurizer Surge Line Piping JCN N6398, Task 1B

Research is being conducted for the U.S. Nuclear Regulatory Commission (NRC) at the Pacific Northwest National Laboratory (PNNL) to assess the effectiveness and reliability of advanced nondestructive examination (NDE) methods for the inspection of light water reactor components. The scope of this research encompasses primary system pressure boundary materials including cast austenitic stainless steels (CASS); dissimilar metal welds; piping with corrosion-resistant cladding; weld overlays, inlays and onlays; and far-side examinations of austenitic piping welds. A primary objective of this work is to evaluate various NDE methods to assess their ability to detect, localize, and size cracks in coarse-grained steel components. In this effort, PNNL supports cooperation with Commissariat à l’Energie Atomique (CEA) to assess reliable inspection of CASS materials. The NRC Project Manager has established a cooperative effort with the Institut de Radioprotection et de Surete Nucleaire (IRSN). CEA, under funding from IRSN, are supporting collaborative efforts with the NRC and PNNL. Regarding its work on the NDE of materials, CEA is providing its modeling software (CIVA) in exchange for PNNL offering expertise and data related to phased-array detection and sizing, acoustic attenuation, and back scattering on CASS materials. This collaboration benefits the NRC because CEA performs research and development on CASS for Électricité de France (EdF). This technical letter report provides a summary of a technical evaluation aimed at assessing the capabilities of phased-array (PA) ultrasonic testing (UT) methods as applied to the inspection of welds in CASS pressurizer (PZR) surge line nuclear reactor piping. A set of thermal fatigue cracks (TFCs) was implanted into three CASS PZR surge-line specimens (pipe-to-elbow welds) that were fabricated using vintage CASS materials formed in the 1970s, and flaw responses from these cracks were used to evaluate detection and sizing performance of the PA-UT methods applied. This effort was comprised of multiple elements that included use of microstructural knowledge (dimensional analysis, grain orientation, and grain type) as well as sound field modeling to more effectively modify inspection parameters and enhance the inspection outcomes. Advanced probe design and sound field simulations were employed to enhance detection and characterization of circumferentially oriented flaws, and an assessment of lateral (circumferential) flaw localization capability and performance was also conducted. An evaluation of flaw detection, length sizing, depth sizing, and signal-to-noise ratio was performed for all flaws in the subject specimens, as a function of various inspection parameters, and finally, measurements were made to quantify and assess the baseline CASS material noise and its potential impact on flaw detection.

36 MATERIALS SCIENCE↗

High Power Flex-Propellant Arcjet Performance

A MW-class electrothermal arcjet based on a water-cooled, wall-stabilized, constricted arc discharge configuration was subjected to extensive performance testing using hydrogen and simulated ammonia propellants with the deliberate aim of advancing technology readiness level for potential space propulsion applications. The breadboard design incorporates alternating conductor/insulator wafers to form a discharge barrel enclosure with a 2.5-cm internal bore diameter and an overall length of approximately 1 meter. Swirling propellant flow is introduced into the barrel, and a DC arc discharge mode is established between a backplate tungsten cathode button and a downstream ringanode/ spin-coil assembly. The arc-heated propellant then enters a short mixing plenum and is accelerated through a converging-diverging graphite nozzle. This innovative design configuration differs substantially from conventional arcjet thrusters, in which the throat functions as constrictor and the expansion nozzle serves as the anode, and permits the attainment of an equilibrium sonic throat (EST) condition. During the test program, applied electrical input power was varied between 0.5-1 MW with hydrogen and simulated ammonia flow rates in the range of 4-12 g/s and 15-35 g/s, respectively. The ranges of investigated specific input energy therefore fell between 50-250 MJ/kg for hydrogen and 10-60 MJ/kg for ammonia. In both cases, observed arc efficiencies were between 40-60 percent as determined via a simple heat balance method based on electrical input power and coolant water calorimeter measurements. These experimental results were found to be in excellent agreement with theoretical chemical equilibrium predictions, thereby validating the EST assumption and enabling the utilization of standard TDK nozzle expansion analyses to reliably infer baseline thruster performance characteristics. Inferred specific impulse performance accounting for recombination kinetics during the expansion process implied nearly frozen flow in the nozzle and yielded performance ranges of 800-1100 sec for hydrogen and 400-600 sec for ammonia. Inferred thrust-to-power ratios were in the range of 30-10 lbf/MWe for hydrogen and 60-20 lbf/MWe for ammonia. Successful completion of this test series represents a fundamental milestone in the progression of high power arcjet technology, and it is hoped that the results may serve as a reliable touchstone for the future development of MW-class regeneratively-cooled flex-propellant plasma rockets.

Litchford, Ron J.↗

Experimental validation of the TOPAS Monte Carlo system for passive scattering proton therapy

Purpose: TOPAS (TOol for PArticle Simulation) is a particle simulation code recently developed with the specific aim of making Monte Carlo simulations user-friendly for research and clinical physicists in the particle therapy community. The authors present a thorough and extensive experimental validation of Monte Carlo simulations performed with TOPAS in a variety of setups relevant for proton therapy applications. The set of validation measurements performed in this work represents an overall end-to-end testing strategy recommended for all clinical centers planning to rely on TOPAS for quality assurance or patient dose calculation and, more generally, for all the institutions using passive-scattering proton therapy systems. Methods: The authors systematically compared TOPAS simulations with measurements that are performed routinely within the quality assurance (QA) program in our institution as well as experiments specifically designed for this validation study. First, the authors compared TOPAS simulations with measurements of depth-dose curves for spread-out Bragg peak (SOBP) fields. Second, absolute dosimetry simulations were benchmarked against measured machine output factors (OFs). Third, the authors simulated and measured 2D dose profiles and analyzed the differences in terms of field flatness and symmetry and usable field size. Fourth, the authors designed a simple experiment using a half-beam shifter to assess the effects of multiple Coulomb scattering, beam divergence, and inverse square attenuation on lateral and longitudinal dose profiles measured and simulated in a water phantom. Fifth, TOPAS’ capabilities to simulate time dependent beam delivery was benchmarked against dose rate functions (i.e., dose per unit time vs time) measured at different depths inside an SOBP field. Sixth, simulations of the charge deposited by protons fully stopping in two different types of multilayer Faraday cups (MLFCs) were compared with measurements to benchmark the nuclear interaction models used in the simulations. Results: SOBPs’ range and modulation width were reproduced, on average, with an accuracy of +1, −2 and ±3 mm, respectively. OF simulations reproduced measured data within ±3%. Simulated 2D dose-profiles show field flatness and average field radius within ±3% of measured profiles. The field symmetry resulted, on average in ±3% agreement with commissioned profiles. TOPAS accuracy in reproducing measured dose profiles downstream the half beam shifter is better than 2%. Dose rate function simulation reproduced the measurements within ∼2% showing that the four-dimensional modeling of the passively modulation system was implement correctly and millimeter accuracy can be achieved in reproducing measured data. For MLFCs simulations, 2% agreement was found between TOPAS and both sets of experimental measurements. The overall results show that TOPAS simulations are within the clinical accepted tolerances for all QA measurements performed at our institution. Conclusions: Our Monte Carlo simulations reproduced accurately the experimental data acquired through all the measurements performed in this study. Thus, TOPAS can reliably be applied to quality assurance for proton therapy and also as an input for commissioning of commercial treatment planning systems. This work also provides the basis for routine clinical dose calculations in patients for all passive scattering proton therapy centers using TOPAS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FINAL TECHNICAL REPORT

NIST has played a key role in many of the one-on-one, domestic, and international interlaboratory comparisons of measurements on superconductors. The history of interlaboratory comparisons of measurements on superconductors tells us that careful measurement methods are needed to obtain consistent results. Inconsistent results can lead to many problems including: a mistrust of the results of others, unfair advantages in commerce, and erroneous feedback in the optimization of conductor performance. NIST has experience in many interlaboratory comparisons; a long-term commitment to measurement accuracy; and independent, third-party laboratory status. The principal investigator's direct involvement in the measurements and daily supervision of sample mounting is the unique situation that has allowed important discoveries and evolution of our capabilities over the last 30 years. The principal investigator's research and metrology has helped to improve the accuracy of critical-current (I{sub c}) measurements in laboratories throughout the world. As conductors continue to improve and design limits are tested, the continuation of the long-term commitment to measurement accuracy could be vitally important to the success of new conductor development programs. It is extremely important to the U.S. wire manufacturers to get accurate (high certainty) I{sub c} measurements in order to optimize conductor performance. The optimization requires the adjustment of several fabrication parameters (such as reaction time, reaction temperature, conductor design, doping, diffusion barrier, Cu to non-Cu ratio, and twist pitch) based on the I{sub c} measurement of the conductor. If the I{sub c} measurements are made with high variability, it may be unclear whether or not the parameters are being adjusted in the optimal direction or whether or not the conductor meets the target specification. Our metrology is vital to the U.S. wire manufacturers in the highly competitive international arena and to meet the aggressive performance goals. The latest high-performance Nb{sub 3}Sn wires are being designed with higher current densities, larger effective filament diameter, less Cu stabilizer, and, in some cases, larger wire diameters than ever before. In addition, some of the conductor designs and heat treatments cause the residual resistivity ratio (RRR, ratio of room temperature resistivity to the resistivity at 20 K) of the stabilizer to be less than 20. These parameters are pushing the conductors towards less intrinsic stability, into a region we call marginally stable. These parameters also create a whole series of challenges for routine I{sub c} testing on short-samples, even when tested with the sample immersed in liquid helium. High-current, variable-temperature I{sub c} measurements are even more difficult than those made in liquid helium because the sample is only cooled by flowing helium gas. Providing accurate I{sub c} results under these conditions requires a complex system that provide adequate cooling as well as uniform sample temperature. We have been make variable-temperature measurements for about 15 years, but we started to design the first high-current (at least 500 A), variable-temperature, variable-strain apparatus in late 2006. Our first critical-current measurements as a function of strain, temperature, and magnetic field, I{sub c}(B,T,{var_epsilon}), in a new single, unified apparatus (full matrix characterization) were made in the summer of 2008. This is the only such facility in the U.S. and it has some unique components that are not duplicated anywhere in the world. The compounding of all three variables (H, T, {var_epsilon}) makes an already labor and time intensive characterization very formidable; however, the results cannot be generated any other way and are needed to answer key questions about strain and temperature safety margins and about the reliability of using scaling laws based on small data sets to predict performance. In the future, this new apparatus will allow NIST to create a database on strands that would benefit U.S. superconductor wire manufacturers, national research laboratories, and programs using superconductor strands such as HEP and International Thermonuclear Experimental Reactor (ITER).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wind-induced torsion of parabolic trough collectors in operation

Parabolic trough collector (PTC) systems, a type of concentrating solar power (CSP), use parabolic mirrors to reflect the sun's rays toward an absorber tube to heat the fluid inside. PTCs track the sun throughout the day and are sensitive to angular misalignment, which reduces optical performance. Torsion of the PTC, exacerbated by wind loading, contributes to angular misalignment, which has been quantified by previous studies using numerical simulations and experimental tests. However, angular misalignment due to torsion and wind loading has not yet been studied in an operational plant, which can experience more extreme and variable conditions. This study characterizes the angular misalignment due to torsion at three rows of the Nevada Solar One CSP plant and investigates the influence of wind loading. These findings reveal substantial torsion along the PTC support structure that depends on wind conditions and orientation. Strong winds perpendicular to the PTCs increase the median angular displacement of the outermost row by up to 18 mrad and increase the standard deviation by up to 8 mrad when compared to weak wind conditions. These findings can inform enhanced PTC design, controls and modeling that will improve the performance, reliability and bankability of future CSP plants.

14 SOLAR ENERGY↗