Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Optics measurements and corrections at RHIC

The further improvement of RHIC luminosity performance requires more precise understanding of the RHIC modeling. Hence, it is necessary to minimize the beta-beat, deviation of measured beta function from the calculated beta functions based on an model. The correction of betabeat also opens up the possibility of exploring operating RHIC polarized protons at a working point near integer, a prefered choice for both luminosity as well as beam polarization. The segment-by-segment technique for reducing beta-beat demonstrated in the LHC operation for reducing the beta-beat was first tested in RHIC during its polarized proton operation in 2011. It was then fully implemented during the RHIC polarized proton operation in 2012. This paper reports the commissioning results. Future plan is also presented.

43 PARTICLE ACCELERATORS↗

High-temperature and high-pressure NMR investigations of low viscous fluids confined in mesoporous systems

Abstract In this contribution, the relaxation and diffusional behaviors of low viscous fluids, water and methanol confined into mesoporous silica and controlled size pore glass were investigated. The engineered porous systems are relevant to geologically important subsurface energy materials. The engineered porous proxies were characterized by Brunauer–Emmett–Teller (BET) surface analyzer, nuclear magnetic resonance (NMR) spectroscopy, and electron microscopy (EM) to determine surface area, pore-wall protonation and morphology of these materials, respectively. The confined behavior of the low viscous fluids was studied by varying pore diameter, fluid-to-solid ratio, temperature, and pressure, and then compared to bulk liquid state. Both relaxation and diffusion behaviors for the confined fluids showed increasing deviation from pure bulk fluids as the fluid-to-solid ratio was decreased, and surface-to-volume ratio ( S / V ) was varied. Variable pressure deuteron NMR relaxation of confined D 2 O and confined methanol, deuterated at the hydroxyl or methyl positions, were performed to exploit the sensitivity of the deuteron quadrupole moment to molecular rotation. The methanol results demonstrated greater pressure dependence than those for water only in bulk. The deviations from bulk liquid behavior arise from different reasons such as confinement and the interactions between confined fluid and the nano-pore wall. The results of the present report give insight into the behavior of low viscosity fluid in nano-confined geometries under different state conditions.

Chemistry↗

SU-F-T-547: Off-Isocenter Winston-Lutz Test for Stereotactic Radiosurgery/stereotactic Body Radiotherapy

Purpose: To perform a quantitative study to verify that the mechanical field center coincides with the radiation field center when both are off from the isocenter during the single-isocenter technique in linear accelerator-based SRS/SBRT procedure to treat multiple lesions. Methods: We developed an innovative method to measure this accuracy, called the off-isocenter Winston-Lutz test, and here we provide a practical clinical guideline to implement this technique. We used ImagePro V.6 to analyze images of a Winston-Lutz phantom obtained using a Varian 21EX linear accelerator with an electronic portal imaging device, set up as for single-isocenter SRS/SBRT for multiple lesions. We investigated asymmetry field centers that were 3 cm and 5 cm away from the isocenter, as well as performing the standard Winston-Lutz test. We used a special beam configuration to acquire images while avoiding collision, and we investigated both jaw and multileaf collimation. Results: For the jaw collimator setting, at 3 cm off-isocenter, the mechanical field deviated from the radiation field by about 2.5 mm; at 5 cm, the deviation was above 3 mm, up to 4.27 mm. For the multileaf collimator setting, at 3 cm off-isocenter, the deviation was below 1 mm; at 5 cm, the deviation was above 1 mm, up to 1.72 mm, which is 72% higher than the tolerance threshold. Conclusion: These results indicated that the further the asymmetry field center is from the machine isocenter, the larger the deviation of the mechanical field from the radiation field, and the distance between the center of the asymmetry field and the isocenter should not exceed 3 cm in of our clinic. We recommend that every clinic that uses linear accelerator, multileaf collimator-based SRS/SBRT perform the off-isocenter Winston-Lutz test in addition to the standard Winston-Lutz test and use their own deviation data to design the treatment plan.

60 APPLIED LIFE SCIENCES↗

Comparative Analysis via CFD Simulation on the Impact of Graphite Anode Morphologies on the Discharge of a Lithium-Ion Battery

The morphology of electrode materials plays a crucial role in determining the performance of lithium-ion batteries. Traditional computational models often simplify graphite flakes as uniformly sized spheres, which limits their predictive accuracy. In this study, we present a computational workflow that overcomes these limitations by incorporating a more realistic representation of graphite morphologies. This workflow is designed to be flexible and reproducible, enabling efficient evaluation of electrochemical performance across diverse material structures. By exploring different graphite morphologies, our approach accelerates the optimization of material preparation techniques and processing conditions. Our findings reveal that incorporating greater morphological complexity leads to significant deviations from classical model predictions. Instead, our refined model offers a more accurate representation of battery discharge behavior, closely aligning with experimental data. This improvement underscores the importance of detailed morphological descriptions in advancing battery design and performance assessments. To promote accessibility and reproducibility, we provide the developed code for seamless integration with the COMSOL API, allowing researchers to implement and adapt it easily. This computational framework serves as a valuable tool for investigating the impact of graphite morphology on battery performance, bridging the gap between theoretical modeling and experimental validation to enhance lithium-ion battery technology.

25 ENERGY STORAGE↗

Simulation and research of few-mode optical fiber DMD degradation due to geometry deviation from optimized form

This work presents an alternative fast and simple method for the design of a graded refractive index profile of silica few-mode optical fibers (FMFs) with enlarged core diameter that extremely improves mode effective area, and low differential mode delay (DMD). We demonstrate some results of refractive index profile optimization for 16-LP-mode FMF with enlarged core diameter up to 42 μm and mode effective area more 130 μm{sup 2} under DMD reduction less 120 ps/km all over “C”-band and less 40 ps/km at λ = 1550 nm region. We also propose approach for simulation of the deviation of “real” optical fiber geometry from the optimized form and rigorous method for analysis of large core complicated optical fiber. Here, FMF core asymmetrical ellipticity together with the refractive index profile distortions were considered. They were set and simulated by data from reports of the real commercially available laser-optimized multimode optical fibers of TIA/ISO Cat. OM2+/OM3 refractive index profile measurements, performed by lab optical fiber analyzer kit. We present results of researches of considered FMF DMD spectral curve degradation due to described core geometry deviation from the optimized form. It was noticed, that unlike to only refractive index local fluctuations, FMF core non-circularity strongly distorts higher-order mode field distribution that affects to spectral mode delay curves and may lead to critical total DMD increasing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A BAYESIAN METHOD FOR THE INTERCALIBRATION OF SPECTRA IN REVERBERATION MAPPING

Flux calibration of spectra in reverberation mapping (RM) is most often performed by assuming the flux constancy of some specified narrow emission lines, which stem from an extended region that is sometimes partially spatially resolved, in contrast to the point-like broad-line region and the central continuum source. The inhomogeneous aperture geometries used among different observation sets in a joint monitoring campaign introduce systematic deviations to the fluxes of broad lines and central continuum, and intercalibration over these data sets is required. As an improvement to the previous empirical correction performed by comparing the (nearly) contemporaneous observation points, we describe a feasible Bayesian method that obviates the need for (nearly) contemporaneous observations, naturally incorporates physical models of flux variations, and fully takes into account the measurement errors. In particular, it fits all the data sets simultaneously regardless of samplings and makes use of all of the information in the data sets. A Markov Chain Monte Carlo implementation is employed to recover the parameters and uncertainties for intercalibration. Application to the RM data sets of NGC 5548 with joint monitoring shows the high fidelity of our method.

79 ASTRONOMY AND ASTROPHYSICS↗

Compact CH 4 sensor system based on a continuous-wave, low power consumption, room temperature interband cascade laser

A tunable diode laser absorption spectroscopy-based methane sensor, employing a dense-pattern multi-pass gas cell and a 3.3 µm, CW, DFB, room temperature interband cascade laser (ICL), is reported. The optical integration based on an advanced folded optical path design and an efficient ICL control system with appropriate electrical power management resulted in a CH 4 sensor with a small footprint (32 x 20 x 17 cm 3 ) and low-power consumption (6 W). Polynomial and least-squares fit algorithms are employed to remove the baseline of the spectral scan and retrieve CH 4 concentrations, respectively. An Allan-Werle deviation analysis shows that the measurement precision can reach 1.4 ppb for a 60 s averaging time. Continuous measurements covering a seven-day period were performed to demonstrate the stability and robustness of the reported CH 4 sensor system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fitting the constitution type Ia supernova data with the redshift-binned parametrization method

In this work, we explore the cosmological consequences of the recently released Constitution sample of 397 Type Ia supernovae (SNIa). By revisiting the Chevallier-Polarski-Linder (CPL) parametrization, we find that, for fitting the Constitution set alone, the behavior of dark energy (DE) significantly deviates from the cosmological constant {lambda}, where the equation of state (EOS) w and the energy density {rho}{sub {lambda}} of DE will rapidly decrease along with the increase of redshift z. Inspired by this clue, we separate the redshifts into different bins, and discuss the models of a constant w or a constant {rho}{sub {lambda}} in each bin, respectively. It is found that for fitting the Constitution set alone, w and {rho}{sub {lambda}} will also rapidly decrease along with the increase of z, which is consistent with the result of CPL model. Moreover, a step function model in which {rho}{sub {lambda}} rapidly decreases at redshift z{approx}0.331 presents a significant improvement ({delta}{chi}{sup 2}=-4.361) over the CPL parametrization, and performs better than other DE models. We also plot the error bars of DE density of this model, and find that this model deviates from the cosmological constant {lambda} at 68.3% confidence level (CL); this may arise from some biasing systematic errors in the handling of SNIa data, or more interestingly from the nature of DE itself. In addition, for models with same number of redshift bins, a piecewise constant {rho}{sub {lambda}} model always performs better than a piecewise constant w model; this shows the advantage of using {rho}{sub {lambda}}, instead of w, to probe the variation of DE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interaction between water and carbon nanostructures: How good are current density functional approximations?

Due to their current and future technological applications, including realization of water filters and desalination membranes, water adsorption on graphitic sp2-bonded carbon is of overwhelming interest. However, these systems are notoriously challenging to model, even for electronic structure methods such as density functional theory (DFT), because of the crucial role played by London dispersion forces and noncovalent interactions, in general. Recent efforts have established reference quality interactions of several carbon nanostructures interacting with water. Here, we compile a new benchmark set (dubbed WaC18), which includes a single water molecule interacting with a broad range of carbon structures and various bulk (3D) and two-dimensional (2D) ice polymorphs. The performance of 28 approaches, including semilocal exchange-correlation functionals, nonlocal (Fock) exchange contributions, and long-range van der Waals (vdW) treatments, is tested by computing the deviations from the reference interaction energies. The calculated mean absolute deviations on the WaC18 set depend crucially on the DFT approach, ranging from 135 meV for local density approximation (LDA) to 12 meV for PBE0-D4. We find that modern vdW corrections to DFT significantly improve over their precursors. Within the 28 tested approaches, we identify the best performing within the functional classes of generalized gradient approximated (GGA), meta-GGA, vdW-DF, and hybrid DF, which are BLYP-D4, TPSS-D4, rev-vdW-DF2, and PBE0-D4, respectively.

Brandenburg, Jan Gerit (ORCID:0000000292192948)↗

Assessment of the Building 3430 Filtered Exhaust Stack Sampling Probe Location

Pacific Northwest National Laboratory performed a demonstration to determine the acceptable location in which to place an air sampling probe for emissions monitoring for radionuclides in the exhaust air discharge from the new 3430 Building Filtered Pathway Stack . The method was to adopt the results of a previously performed test series for a system of similar configuration, followed by a partial test on the actual system to verify the applicability of previously performed tests. The qualification criteria included 1) a uniform air velocity, 2) an average flow angle that does not deviate from the axis of the duct by more than 20°, 3) a uniform concentration of tracer gases, and 4) a uniform concentration of tracer particles. Section 1 provides background information for the demonstration, and Section 2 describes the test strategy, including the criteria for the applicability of model results and the test matrix. Section 3 describes the flow angle test and the velocity uniformity test, Section 4 provides the test results, and Section 5 provides the conclusions. Appendix A includes the test data sheets, and Appendix B gives applicable qualification results from the previously tested model stack. The data from the previously tested and similarly designed stack was demonstrated to be applicable to the current design for the 3430 Building Filtered Pathway stack. Therefore, this new system also meets the qualification criteria given in the ANSI/HPS N13.1 standard. Changes to the system configuration or operations outside of the bounds of this report (e.g., exhaust velocity increases, relocation of sample probe) will require retesting/reevaluation to determine compliance to the requirements.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition

Purpose: The objective of this work is to assess the sensitivity of Monte Carlo (MC) dose calculations to uncertainties in human tissue composition for a range of low photon energy brachytherapy sources: {sup 125}I, {sup 103}Pd, {sup 131}Cs, and an electronic brachytherapy source (EBS). The low energy photons emitted by these sources make the dosimetry sensitive to variations in tissue atomic number due to the dominance of the photoelectric effect. This work reports dose to a small mass of water in medium D{sub w,m} as opposed to dose to a small mass of medium in medium D{sub m,m}. Methods: Mean adipose, mammary gland, and breast tissues (as uniform mixture of the aforementioned tissues) are investigated as well as compositions corresponding to one standard deviation from the mean. Prostate mean compositions from three different literature sources are also investigated. Three sets of MC simulations are performed with the GEANT4 code: (1) Dose calculations for idealized TG-43-like spherical geometries using point sources. Radial dose profiles obtained in different media are compared to assess the influence of compositional uncertainties. (2) Dose calculations for four clinical prostate LDR brachytherapy permanent seed implants using {sup 125}I seeds (Model 2301, Best Medical, Springfield, VA). The effect of varying the prostate composition in the planning target volume (PTV) is investigated by comparing PTV D{sub 90} values. (3) Dose calculations for four clinical breast LDR brachytherapy permanent seed implants using {sup 103}Pd seeds (Model 2335, Best Medical). The effects of varying the adipose/gland ratio in the PTV and of varying the elemental composition of adipose and gland within one standard deviation of the assumed mean composition are investigated by comparing PTV D{sub 90} values. For (2) and (3), the influence of using the mass density from CT scans instead of unit mass density is also assessed. Results: Results from simulation (1) show that variations in the mean compositions of tissues affect low energy brachytherapy dosimetry. Dose differences between mean and one standard deviation of the mean composition increasing with distance from the source are observed. It is established that the {sup 125}I and {sup 131}Cs sources are the least sensitive to variations in elemental compositions while {sup 103}Pd is most sensitive. The EBS falls in between and exhibits complex behavior due to significant spectral hardening. Results from simulation (2) show that two prostate compositions are dosimetrically equivalent to water while the third shows D{sub 90} differences of up to 4%. Results from simulation (3) show that breast is more sensitive than prostate with dose variations of up to 30% from water for 70% adipose/30% gland breast. The variability of the breast composition adds a {+-}10% dose variation. Conclusions: Low energy brachytherapy dose distributions in tissue differ from water and are influenced by density, mean tissue composition, and patient-to-patient composition variations. The results support the use of a dose calculation algorithm accounting for heterogeneities such as MC. Since this work shows that variations in mean tissue compositions affect MC dosimetry and result in increased dose uncertainties, the authors conclude that imaging tools providing more accurate estimates of elemental compositions such as dual energy CT would be beneficial.

60 APPLIED LIFE SCIENCES↗

Potential for Higher Treatment Failure in Obese Patients: Correlation of Elevated Body Mass Index and Increased Daily Prostate Deviations From the Radiation Beam Isocenters in an Analysis of 1,465 Computed Tomographic Images

Purpose: Recent clinical outcome studies on prostate cancer have reported the influence of patient's obesity on the biochemical failure rates after various treatment modalities. In this study, we investigated the effect of patient's physical characteristics on prostate shift in external beam radiotherapy (EBRT) and hypothesized that there maybe a correlation between patient physique and tumor shift. Methods and Materials: A retrospective analysis was performed using data for 117 patients who received image-guided radiation therapy (IGRT) for prostate cancer between January 2005 and April 2007. A total of 1,465 CT scans were analyzed. The standard deviations (SDs) of prostate shifts for all patients, along with patient weight, body mass index (BMI), and subcutaneous adipose-tissue thickness (SAT), were determined. Spearman rank correlation analysis was performed. Results: Of the 117 patients, 26.5% were considered normal weight, 48.7% were overweight, 17.9% were mildly obese, and 6.9% were moderately to severely obese. Notably 1.3%, 1.5%, 2.0%, and 21.2% of the respective shifts were greater than 10 mm in the left-right (LR) direction for the four patient groups, whereas in the anterior-posterior direction the shifts are 18.2%, 12.6%, 6.7%, and 21.0%, respectively. Strong correlations were observed between SAT, BMI, patient weight, and SDs of daily shifts in the LR direction (p < 0.01). Conclusions: The strong correlation between obesity and shift indicates that without image-guided radiation therapy, the target volume (prostate with or without seminal vesicles) may not receive the intended dose for patients who are moderate to severely obese. This may explain the higher recurrence rate with conventional external beam radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Immobilization on Intrafraction Motion for Spine Stereotactic Body Radiotherapy Using Cone Beam Computed Tomography

Purpose: Spine stereotactic body radiotherapy (SBRT) involves tight planning margins and steep dose gradients to the surrounding organs at risk (OAR). This study aimed to assess intrafraction motion using cone beam computed tomography (CBCT) for spine SBRT patients treated using three immobilization devices. Methods and Materials: Setup accuracy using CBCT was retrospectively analyzed for 102 treated spinal metastases in 84 patients. Thoracic and lumbar spine patients were immobilized with either an evacuated cushion (EC, n = 24) or a semirigid vacuum body fixation (BF, n = 60). For cases treated at cervical/upper thoracic (thoracic [T]1-T3) vertebrae, a thermoplastic S-frame (SF) mask (n = 18) was used. Patient setup was corrected by using bony anatomy image registration and couch translations only (no rotation corrections) with shifts confirmed on verification CBCTs. Repeat imaging was performed mid- and post-treatment. Patient translational and rotational positioning data were recorded to calculate means, standard deviations (SD), and corresponding margins {+-} 2 SD for residual setup errors and intrafraction motion. Results: A total of 355 localizations, 333 verifications, and 248 mid- and 280 post-treatment CBCTs were analyzed. Residual translations and rotations after couch corrections (verification scans) were similar for all immobilization systems, with SDs of 0.6 to 0.9 mm in any direction and 0.9 Degree-Sign to 1.6 Degree-Sign , respectively. Margins to encompass residual setup errors after couch corrections were within 2 mm. Including intrafraction motion, as measured on post-treatment CBCTs, SDs for total setup error in the left-right, cranial-caudal, and anterior-posterior directions were 1.3, 1.2, and 1.0 mm for EC; 0.9, 0.7, and 0.9 mm for BF; and 1.3, 0.9, and 1.1 mm for SF, respectively. The calculated margins required to encompass total setup error increased to 3 mm for EC and SF and remained within 2 mm for BF. Conclusion: Following image guidance, residual setup errors for spine SBRT were similar across three immobilization systems. The BF device resulted in the least amount of intrafraction motion, and based on this device, we justify a 2-mm margin for the planning OAR and target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and validation of a reduced mechanism for urea-based SNCR process based on QSS graph

This paper reports a reduced mechanism used in urea-based SNCR process for NOx control that is developed from the detailed mechanism originally proposed by Rota et al. (Chem. Eng. Sci. 2002, 57, 27-38) consisting of 173 elemental reactions and 31 chemical species. Sensitivity analysis and rate-of-production analysis are first conducted to exclude redundant elemental reactions and species, forming a skeletal mechanism. After that, quasi-steady-state species are identified and a 12-step 16-species reduced mechanism is established. The balance equations for quasi-steady-state species are innovatively solved by means of QSS graph method presented by Lu and Law (J. Phys. Chem. A2006, 110, 13202-13208) with the avoidance of efficiency compromise stemming from algebraic iterations. The predictions of the reduced mechanism show satisfactory agreement with those of the detailed one over a wide range of operating conditions, including various temperatures, molar ratio of CO(NH{sub 2}){sub 2}/NO and O{sub 2} and CO concentrations. The performances of QSS graph method and traditional QSSA by iteration are compared in plug-flow computations. The deviation in accuracy is only in order of 0.01%, while QSS graph creates nearly 40% speed-up significantly superior to QSSA by iteration. 30 refs., 9 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Nanoscopic cross-grain cation homogenization in perovskite solar cells

Multiscale cation inhomogeneity has been a major hurdle in state-of-the-art formamidinium–caesium (FA–Cs) mixed-cation perovskites for achieving perovskite solar cells with optimal power conversion efficiencies and durability. Although the field has attempted to homogenize the overall distributions of FA–Cs in perovskite films from both plan and cross-sectional views, our understanding of grain-to-grain cation inhomogeneity and ability to tailor it—that is, spatially resolving the FA–Cs compositional difference between individual grains down to the nanoscale—are lacking. Here we reveal that as fundamental building blocks of a perovskite film, individual grains exhibit cationic compositions deviating from the prescribed ideal composition, severely limiting the interfacial optoelectronic properties and perovskite layer durability. This performance-limiting nanoscopic factor is linked to thermodynamic-driven morphological grooving, leading to a segmented surface landscape. At the grain triple junctions, grooves form nanoscale groove traps that hinder the mixing of solid-state cations across grains and thus retard inter-grain FA–Cs mixing. By rationally modulating the heterointerfacial energies, we reduced the depth of these nanoscale groove traps by a factor of three, significantly improving cation homogeneity. Perovskite solar cells with shallower nanoscale groove traps demonstrate enhanced power conversion efficiencies (25.62%) and improved stability under various standardized international protocols. In conclusion, our work highlights the significance of resolving surface nano-morphologies for homogeneous properties of perovskites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Approaching the basis set limit for DFT calculations using an environment-adapted minimal basis with perturbation theory: Formulation, proof of concept, and a pilot implementation

Recently developed density functionals have good accuracy for both thermochemistry (TC) and non-covalent interactions (NC) if very large atomic orbital basis sets are used. To approach the basis set limit with potentially lower computational cost, a new self-consistent field (SCF) scheme is presented that employs minimal adaptive basis (MAB) functions. The MAB functions are optimized on each atomic site by minimizing a surrogate function. High accuracy is obtained by applying a perturbative correction (PC) to the MAB calculation, similar to dual basis approaches. Compared to exact SCF results, using this MAB-SCF (PC) approach with the same large target basis set produces <0.15 kcal/mol root-mean-square deviations for most of the tested TC datasets, and <0.1 kcal/mol for most of the NC datasets. The performance of density functionals near the basis set limit can be even better reproduced. With further improvement to its implementation, MAB-SCF (PC) is a promising lower-cost substitute for conventional large-basis calculations as a method to approach the basis set limit of modern density functionals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrawide bandgap vertical β-(Al x Ga1 −x )2O3 Schottky barrier diodes on free-standing β-Ga2O3 substrates

Ultrawide bandgap β-(AlxGa1−x)2O3 vertical Schottky barrier diodes on (010) β-Ga2O3 substrates are demonstrated. The β-(AlxGa1−x)2O3 epilayer has an Al composition of 21% and a nominal Si doping of 2 × 1017 cm−3 grown by molecular beam epitaxy. Pt/Ti/Au has been employed as the top Schottky contact, whereas Ti/Au has been utilized as the bottom Ohmic contact. The fabricated devices show excellent rectification with a high on/off ratio of ∼109, a turn-on voltage of 1.5 V, and an on-resistance of 3.4 mΩ cm2. Temperature-dependent forward current-voltage characteristics show effective Schottky barrier height varied from 0.91 to 1.18 eV while the ideality factor from 1.8 to 1.1 with increasing temperatures, which is ascribed to the inhomogeneity of the metal/semiconductor interface. The Schottky barrier height was considered a Gaussian distribution of potential, where the extracted mean barrier height and a standard deviation at zero bias were 1.81 and 0.18 eV, respectively. A comprehensive analysis of the device leakage was performed to identify possible leakage mechanisms by studying temperature-dependent reverse current-voltage characteristics. At reverse bias, due to the large Schottky barrier height, the contributions from thermionic emission and thermionic field emission are negligible. By fitting reverse leakage currents at different temperatures, it was identified that Poole–Frenkel emission and trap-assisted tunneling are the main leakage mechanisms at high- and low-temperature regimes, respectively. Electrons can tunnel through the Schottky barrier assisted by traps at low temperatures, while they can escape these traps at high temperatures and be transported under high electric fields. This work can serve as an important reference for the future development of ultrawide bandgap β-(AlxGa1−x)2O3 power electronics, RF electronics, and ultraviolet photonics.

Materials Science↗

Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography

Purpose: Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-CT. The purpose of this study was to quantify the potential for dose reduction when using CM based on heavy metals. Methods: The contrast-to-noise ratio weighted by dose (CNRD) was determined as a function of scan protocol by means of measurements and simulations on a clinical CT scanner. For simulations, water cylinders with diameters 160, 320, 480, and 640 mm were used to cover a broad range of patient sizes. Measurements were conducted with 160 and 320 mm water-equivalent plastic cylinders. A central bore of 13 mm diameter was present in all phantoms. The tube voltage was varied from 80 to 140 kV for measurements and from 60 to 180 kV for simulations. Additional tin filtration of thicknesses 0.4, 0.8, and 1.2 mm was applied in the simulation to evaluate a range of spectral hardness. The bore was filled with a mixture of water and 10 mg/ml of pure iodine, holmium, gadolinium, ytterbium, osmium, tungsten, gold, and bismuth for the simulations and with aqueous solutions of ytterbium, tungsten, gold, and bismuth salts as well as Iopromid containing 10 mg/ml of the pure materials for the measurements. CNRDs were compared to iodine at phantom size-dependent reference voltages for all high-Z materials and the resulting dose reduction was calculated for equal contrast-to-noise ratio. Results: Dose reduction potentials strongly depended on phantom size, spectral hardness, and tube voltage. Depending on the added filtration, a dose reduction of 19%-60% could be reached at 80 kV with gadolinium for the 160 mm phantom, 52%-69% at 100 kV with holmium for the 320 mm phantom, 62%-78% with 120 kV for hafnium and the 480 mm phantom and 74%-86% with 140 kV for gold and the 640 mm phantom. While gadolinium might be considered at 160 mm diameter, hafnium showed the best overall performance for phantom sizes of 320 mm and above. The measurements conducted on the clinical CT scanner showed very good agreement with simulations with deviations in the order of 5 to 10%. Conclusions: The results of this study encourage the development and use of CM based on high-Z materials, especially for adipose patients, where high tube voltages are necessary to reach sufficiently short scan times. Hafnium proved to be the best compromise for average-size and for adipose patients. Even higher-Z materials such as gold and bismuth showed a good overall performance in conjunction with high tube voltage, large patients or strong added filtration and may be recommended for scans under these conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗