Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Tools”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Loschmidt-amplitude wave function spectroscopy and the physics of dynamically driven phase transitions

In this work, we introduce the Loschmidt amplitude as a powerful tool to perform spectroscopy of generic many-body wave functions and use it to interrogate the wave function obtained after ramping the transverse field quantum Ising model through its quantum critical point. Previous results are confirmed and a more complete understanding of the population of defects and of the effects of magnon-magnon interaction or finite-size corrections is obtained. The influence of quantum coherence is clarified.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing triaxial deformation of atomic nuclei in high-energy heavy ion collisions

Most atomic nuclei are deformed with a quadrupole shape described by its overall strength β 2 and triaxiality γ. The deformation can be accessed in high-energy heavy ion collisions by measuring the collective flow response of the produced quark-gluon plasma to the eccentricity ε 2 and the density gradient d ⊥ in the initial state. Using an analytical estimate and a Glauber model, I show that the variances $\langleε^{2}_{2}\rangle$ or $\langle$(δd ⊥ /d ⊥ ) 2 $\rangle$ and skewnesses $\langleε^{2}_{2}δd_{⊥}/d_{⊥}\rangle$ or $\langle(δd_{⊥}/d_{⊥})^{3}\rangle$ have a simple analytical form of a'+b'β$^{2}_{2}$ and a'+[b'+c' cos(3γ)]β$^{3}_{2}$, respectively. From these, I constructed several normalized skewnesses to isolate the γ dependence from that of β 2 and show that the correlations between a normalized skewness and a variance can constrain simultaneously β 2 and γ. Assuming a linear relation with elliptic flow v 2 and mean-transverse momentum [p T ] of final-state particles, v 2 ∝ ε 2 and δ [p T ] / [p T ] ∝ δd ⊥ /d ⊥ , similar conclusions are also expected for the variances and skewnesses of v 2 and [p T ], i.e., a + bβ$^{2}_{2}$ for $\langle v^{2}_{2}\rangle$ and $\langle(δ[p_{T}] / [p_{T}])^{2}\rangle$ and a + [b + c cos (3γ)] β$^{3}_{2}$ for $\langle v^{2}_{2}δ [p_{T}] / [p_{T}]\rangle$ or $\langle(δ[p_{T}] / [p_{T}])^{3}\rangle$. My findings motivate a dedicated system scan of high-energy heavy ion collisions at RHIC and LHC to measure triaxiality of atomic nuclei: one first determines the coefficients b and c by collisions of isobaric near prolate nuclei, cos (3γ) ≈ 1, and near oblate nuclei, cos (3γ) ≈ –1 , with known β 2 values, followed by collisions of other species of interest with similar mass number. The (β 2 , γ) values for this species can be inferred directly from the measured variance and skewness observables from these collisions. Finally, the results demonstrate the unique opportunities offered by high-energy collisions as a tool to perform interdisciplinary nuclear physics studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiwavelength analysis of annihilating dark matter as the origin of the gamma-ray emission from M31

Indirect detection of dark matter (DM) by multiwavelength astronomical observations provides a promising avenue for probing the particle nature of DM. In the case of DM consisting of weakly interacting massive particles (WIMPs), self-annihilation ultimately produces various observable products including e ± pairs and gamma rays. The gamma rays can be detected directly, while the e ± pairs can be detected by radio emission from synchrotron radiation or X rays and soft gamma rays from inverse Compton scattering. An intriguing region to search for astrophysical signs of DM is the Galactic center (GC) of the Milky Way, due in part to an observed excess of gamma rays that could be DM. A recent observation by the Fermi-LAT collaboration of a similar excess in the central region of the Andromeda galaxy (M31) leads us to explore the possibility of a DM-induced signal there as well. We use the RX-DMFIT tool to perform a multifrequency analysis of potential DM annihilation emissions in M31. We consider WIMP particle models consistent with the GC excess and calculate the expected emission across the electromagnetic spectrum in comparison with available observational data from M31. We find that the particle models that best fit the M31 excess favor lower masses than the GC excess. The best-fitting models are for a $b\bar{b}$ final state with M χ = 11 GeV and $\langle$σv$\rangle$ = 2.6 × 10 -26 cm 3 s -1 , as well as an evenly mixed $\bar{b}$b/τ + τ - final state with M χ = 5.8 GeV and $\langle$σv$\rangle$ = 2.03 × 10 -26 cm 3 s -1 . For conservative estimates of the diffusion and magnetic field models the expected radio emissions appear to be in tension with currently available data in the central region of M31, although this constraint has a fairly strong dependence on the values chosen for parameters describing the magnetic field strength and geometry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Co-Design Study Of Fusion Whole Device Modeling Using Code Coupling

Complex workflows consisting of multiple simulation and analysis codes running concurrently through in-memory coupling is becoming popular due to inherent advantages in online management of large-scale data, resilience, and the code development process. However, orchestrating such a multi-application workflow to efficiently utilize resources on a heterogeneous architecture is challenging. In this paper, we present our results with running the Fusion Whole Device Modeling benchmark workflow on Summit, a pre-exascale supercomputer at Oak Ridge National Laboratory. We explore various resource distribution and process placement mechanisms, including sharing compute nodes between processes from separate applications. We show that fine-grained process placement can have a significant impact towards efficient utilization of the compute power of a node on Summit, and conclude that sophisticated tools for performing co-design studies of multi-application workflows can play an important role towards efficient orchestration of such workflows.

Choi, Jong Youl↗

Model Validation and Demonstration of a Hydrogen Fuel Cell Parcel Delivery Truck

With an emphasis on reducing fossil fuel consumption and emissions, major delivery service corporations have begun deploying and operating Class 6 battery electric delivery vans. Fuel cell hybrid delivery vans offer a zero emissions solution with extended range and route planning flexibility. This paper follows a prior publication [1] on the vehicle modeling and design and presents demonstration data and a validation of the prior modeling and design effort. Here, the validation exercise shows that the modeling tools predict performance and energy efficiency within 5% for most of the routes, while the demonstration data shows that in service operation fuel economy was over 14 km/kg of hydrogen gas. In addition, results from a range test showed the vehicle design and onboard hydrogen storage was able to surpass the design target range of 200 km.

08 HYDROGEN↗

The Ongoing Evolution of OpenMP

Here, this paper presents an overview of the past, present and future of the OpenMP application programming interface (API). While the API originally specified a small set of directives that guided shared memory fork-join parallelization of loops and program sections, OpenMP now provides a richer set of directives that capture a wide range of parallelization strategies that are not strictly limited to shared memory. As we look toward the future of OpenMP, we immediately see further evolution of the support for that range of parallelization strategies and the addition of direct support for debugging and performance analysis tools. Looking beyond the next major release of the specification of the OpenMP API, we expect the specification eventually to include support for more parallelization strategies and to embrace closer integration into its Fortran, C and, in particular, C++ base languages, which will likely require the API to adopt additional programming abstractions.

97 MATHEMATICS AND COMPUTING↗

Insider Threat Cybersecurity Framework Webtool & Methodology: Defending Against Complex Cyber-Physical Threats

The paper demonstrates how the Insider Threat Cybersecurity Framework (ITCF) web tool and methodology help provide a more dynamic, defense-in-depth security posture against insider cyber-physical threats. ITCF includes over 30 cyber-physical security best practices to help organizations identify, protect, detect, respond and recover to sophisticated insider threats and vulnerabilities. The following paper tests the efficacy of this approach and helps validate and verify ITCF’s capabilities and features through various insider attacks use-cases. Three different investment scenarios and explored to determine how an organization can most efficiently leverage ICTF to increase their overall security posture against insider attacks. ITCF also facilitates implementation of the goals outlined in Presidential Executive Order (EO) on Strengthening the Cybersecurity of Federal Networks and Critical Infrastructure (May 2017): To help owners and operators of critical infrastructure identify, protect, detect, respond, and recover cyber threats. ITCF helps organizations with the following features: provides an easy to use rapid assessment tool to perform an insider threat self-assessment; determines the current insider threat cybersecurity posture; defines investment based goals to achieve a target state; connects the cybersecurity posture with business processes, functions, and continuity; and finally, helps develop plans to answer critical organizational cybersecurity questions. In this paper, the webtool and its core capabilities are depicted by performing an extensive comparative assessment over two different high-profile insider threat incidents.

Mylrea, Michael E.↗

SU-E-T-616: Plan Quality Assessment of Both Treatment Planning System Dose and Measurement-Based 3D Reconstructed Dose in the Patient

Purpose: Systematic radiotherapy plan quality assessment promotes quality improvement. Software tools can perform this analysis by applying site-specific structure dose metrics. The next step is to similarly evaluate the quality of the dose delivery. This study defines metrics for acceptable doses to targets and normal organs for a particular treatment site and scores each plan accordingly. The input can be the TPS or the measurement-based 3D patient dose. From this analysis, one can determine whether the delivered dose distribution to the patient receives a score which is comparable to the TPS plan score, otherwise replanning may be indicated. Methods: Eleven neuroblastoma patient plans were exported from Eclipse to the Quality Reports program. A scoring algorithm defined a score for each normal and target structure based on dose-volume parameters. Each plan was scored by this algorithm and the percentage of total possible points was obtained. Each plan also underwent IMRT QA measurements with a Mapcheck2 or ArcCheck. These measurements were input into the 3DVH program to compute the patient 3D dose distribution which was analyzed using the same scoring algorithm as the TPS plan. Results: The mean quality score for the TPS plans was 75.37% (std dev=14.15%) compared to 71.95% (std dev=13.45%) for the 3DVH dose distribution. For 3/11 plans, the 3DVH-based quality score was higher than the TPS score, by between 0.5 to 8.4 percentage points. Eight/11 plans scores decreased based on IMRT QA measurements by 1.2 to 18.6 points. Conclusion: Software was used to determine the degree to which the plan quality score differed between the TPS and measurement-based dose. Although the delivery score was generally in good agreement with the planned dose score, there were some that improved while there was one plan whose delivered dose quality was significantly less than planned. This methodology helps evaluate both planned and delivered dose quality. Sun Nuclear Corporation has provded a license for the software described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-JeP1-01: A Combination of Real Time Electromagnetic Localization and Tracking with Cone Beam Computed Tomography in Stereotactic Radiosurgery for Brain Tumors

Purpose: 1. online verification of patient position during treatment using calypso electromagnetic localization and tracking system. 2. Verification and comparison of positional accuracy between cone beam computed tomography and calypso system. 3. Presenting the advantage of continuation localization in Stereotactic radiosurgery treatments. Methods: Ten brain tumor cases were taken for this study. Patients with head mask were under gone Computed Tomography (CT). Before scanning, mask was cut on the fore head area to keep surface beacons on the skin. Slice thickness of 0.65 mm were taken for this study. x, y, z coordinates of these beacons in TPS were entered into tracking station. Varian True Beam accelerator, equipped with On Board Imager was used to take Cone beam Computed Tomography (CBCT) to localize the patient. Simultaneously Surface beacons were used to localize and track the patient throughout the treatment. The localization values were compared in both systems. For localization CBCT considered as reference. Tracking was done throughout the treatment using Calypso tracking system using electromagnetic array. This array was in tracking position during imaging and treatment. Flattening Filter free beams of 6MV photons along with Volumetric Modulated Arc Therapy was used for the treatment. The patient movement was observed throughout the treatment ranging from 2 min to 4 min. Results: The average variation observed between calypso system and CBCT localization was less than 0.5 mm. These variations were due to manual errors while keeping beacon on the patient. Less than 0.05 cm intra-fraction motion was observed throughout the treatment with the help of continuous tracking. Conclusion: Calypso target localization system is one of the finest tools to perform radiosurgery in combination with CBCT. This non radiographic method of tracking is a real beneficial method to treat patients confidently while observing real-time motion information of the patient.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-00: Research Opportunities with Digital Linear Accelerators

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-01: Trajectory Modulated Arc Therapy: Application to Partial Breast Irradiation

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-02: ET-Reloaded

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-03: 4n Radiotherapy

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-04: Quality Assurance for Advanced Digital Linac Implementations

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-05: Using a Research Real-Time Control Interface to Go Beyond Dynamic MLC Tracking

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

New-Sum: A Novel Online ABFT Scheme For General Iterative Methods

Emerging high-performance computing platforms, with large component counts and lower power margins, are anticipated to be more susceptible to soft errors in both logic circuits and memory subsystems. We present an online algorithm-based fault tolerance (ABFT) approach to efficiently detect and recover soft errors for general iterative methods. We design a novel checksum-based encoding scheme for matrix-vector multiplication that is resilient to both arithmetic and memory errors. Our design decouples the checksum updating process from the actual computation, and allows adaptive checksum overhead control. Building on this new encoding mechanism, we propose two online ABFT designs that can effectively recover from errors when combined with a checkpoint/rollback scheme.

Instantaneous Footprint↗

SMT-Aware Instantaneous Footprint Optimization

Modern architectures employ simultaneous multithreading (SMT) to increase thread-level parallelism. SMT threads share many functional units and the whole memory hierarchy of a physical core. Without a careful code design, SMT threads can easily contend with each other for these shared resources, causing severe performance degradation. Minimizing SMT thread contention for HPC applications running on dedicated platforms is very challenging, because they usually spawn threads within Single Program Multiple Data (SPMD) models. To address this important issue, we introduce a simple scheme for SMT-aware code optimization, which aims to reduce the memory contention across SMT threads.

Instantaneous Footprint↗

HERON

HERON is a modeling toolset and plugin for RAVEN to accelerate stochastic technoeconomic assessment of the economic viability of various grid-energy system configurations, especially with application to electrical grids and integrated energy systems (IES). The frameworks enabling this toolset are INL's RAVEN and its TEAL plugin. The toolset includes automated RAVEN workflow generation tools for performing stochastic analysis and optimization driven by technoeconomic factors. The workflows generated employ RAVEN for parametric or optimizing study of grid component characteristics, and again for stochastic sampling of regulated and deregulated markets, load, and weather histories. The toolset further provides methods for economically-optimal dispatch of system components given the stochastic samples of market, load, and weather histories. The toolset allows assembling of existing and new models through the RAVEN interface to the Modelica process modeling language.

Talbot, PaulW↗