Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Positions of galactic X-ray sources - Galactic longitude between 20 and 55 deg

Precise positions, determined with data from the SAS-3 X-ray observatory, are presented for eight galactic plane X-ray sources (Aql X-1, Ser X-1, 3U 1956+11, 3U 1822-00, 3U 1915-05, A 1845-02, A 1850-08, A 1905+00). Error radii for the positions range from 20 to 50 arc s. Previously proposed optical identifications of three of the sources (Ser X-1, 3U 1956+11, A 1850-08) are supported by these results. Three (Ser X-1, A 1905+00, 3U 1915-05) have been identified as X-ray burst sources.

Doxsey, R. E.↗

Single pass Doppler positioning for Search and Rescue satellite missions

This paper describes the implementation of beacon location experiments involving the NASA Nimbus-6 and the Amateur Satellite Corporation (AMSAT) Oscar-6 and Oscar-7 spacecraft. The purpose of these experiments is to demonstrate the feasibility of determining the geographical location of a low power VHF 'distress beacon' via satellite. Doppler data collected during satellite passes is reduced in a mini-computer by means of a simple algorithm resulting in the simultaneous recovery of the unknown receiver coordinates and the unknown Doppler bias frequency. Results indicate point positioning to within a few kilometers - which is within the required accuracies for the positioning of downed aircraft for Search/Rescue missions.

Schmid, P. E.↗

Noncontacting valve-position indicator

Position of sealed valve or other movable part is indicated without penetrating housing. Flux from magnets connected to stem of hydraulic valve penetrates pressure wall and is sensed by Hall-effect transducer outside wall. When valve closes, moving stem and magnets, voltage from transducer decreases; thus, stem position is indicated without physical contact.

Crovella, E. A.↗

"Blind" position indicator

Position-indicating instrument helps operator align parts without seeing them. Device is useful in industrial operations where parts must be blind-positioned accurately.

Cruzan, R. C.↗

Certain peculiarities of the functioning of the cardiovascular system in bedrest conditions during horizontal and antiorthostatic body positions

The adequate modeling of physiological reactions inherent to the state of weightlessness has become a matter of particular urgency in space medicine. This modeling is necessary for studying the phenomenology and degree of disorders, prognostication of the crew's health, and developing the various preventive measures employed in space flights. A comparison is made of the physiological effects brought about by bed rest in a horizontal and antiorthostatic body position. A study is done of the influence of brief antiorthostatic hypokinesia, simulating the acute period of adaptation to weightlessness, on circulation and on a number of involved analytical systems. The basic model accepted is antiorthostatic hypokinesia with a body position declination angle of 4 deg (head lower than feet). The experiment's duration is dictated by the objectives of the research.

Source record↗

Position and pulse profile of the X-ray transient 4U 0115 + 63

The celestial position of the 3.6-s X-ray pulsar, 4U 0115 + 63, has been measured to a precision of 12 arcsec in one dimension with the scanning modulation collimator experiment on HEAO 1. This result, together with a position obtained with SAS 3, has led to the identification of an early-type star as the optical counterpart. An X-ray luminosity of approximately 3 by 10 to the 37th power erg/s (3-13 keV) is inferred from the observed flux of about 30% that of the Crab and an estimated distance of 5 kpc. The pulse profile over the energy range 3-13 keV is similar to that of Cen X-3.

Johnston, M.↗

Positive isolation disconnect

A disconnect composed basically of two halves each consisting of a poppet valve operable to isolate fluid with essentially zero fluid loss is presented. The two halves are coupled together by a quickly releasable coupling which may be either a coupling ring tightened or loosened by a twisting motion, or a clamp operated by a pivoted to prevent disconnecting the two halves until both valves are in closed condition. The positive feature of the device is one requiring a valve closing step before a disconnect step, and takes structural form in an accentric lobe mounted on the valve operating stem. If some obstruction prevents the poppet from moving to its seat, the eccentric lobe cannot be rotated to the closed position, and the interlock prevents a disconnect.

Friedell, M. V.↗

Investigations of negative and positive cesium ion species

A direct test is provided of the hypothesis of negative ion creation at the anode or collector of a diode operating under conditions simulating a cesium thermionic converter. The experimental technique involves using direct ion sampling through the collector electrode with mass analysis using a quadrupole mass analyzer. Similar measurements are undertaken on positive ions extracted through the emitter electrode. Measurements were made on a variety of gases including pure cesium, helium-cesium mixtures and cesium-hydrogen as well as cesium-xenon mixtures. The gas additive was used primarily to aid in understanding the negative ion formation processes. Measurements were conducted using emitter (cathode) temperatures up to about 1000 F. The major negative ion identified through the collector was Cs(-) with minor negative ion peaks tentatively identified as H(-), H2(-), H3(-), He(-) and a mass 66. Positive ions detected were believed to be Cs(+), Cs2(+) and Cs3(+).

Chanin, L. M.↗

Application of global positioning system to determination of tectonic plate movements and crustal deformations

It is shown that pseudo-range measurements to four GPS satellites based on correlation of the pseudo random code transmissions from the satellites can be used to determine the relative position of ground stations which are separated by several hundred kilometers to a precision at the centimeter level. Carrier signal measurements during the course of passage of satellites over a pair of stations also yield centimeter precision in the relative position, but oscillator instabilities limit the accuracy. The accuracy of solutions based on either type of data is limited by unmodeled tropospheric refraction effects which would reach 5 centimeters at low elevation angles for widely separated stations.

Anderle, R. J.↗

Effect of outboard vertical-fin position and orientation on the low-speed aerodynamic performance of highly swept wings

A theoretical study was conducted to determine the potential low-speed performance improvements which can be achieved by altering the position and orientation of the outboard vertical fins of low-aspect-ratio highly swept wings. Results show that the magnitude of the performance improvements is solely a function of the span-load distribution. Both the vertical-fin-chordwise position and toe angle provided effective means for adjusting the overall span-load distribution.

Johnson, V. S.↗

Time determination for spacecraft users of the Navstar Global Positioning System /GPS/

Global Positioning System (GPS) navigation is performed by time measurements. A description is presented of a two body model of spacecraft motion. Orbit determination is the process of inferring the position, velocity, and clock offset of the user from measurements made of the user motion in the Newtonian coordinate system. To illustrate the effect of clock errors and the accuracy with which the user spacecraft time and orbit may be determined, a low-earth-orbit spacecraft (Seasat) as tracked by six Phase I GPS space vehicles is considered. The obtained results indicate that in the absence of unmodeled dynamic parameter errors clock biases may be determined to the nanosecond level. There is, however, a high correlation between the clock bias and the uncertainty in the gravitational parameter GM, i.e., the product of the universal gravitational constant and the total mass of the earth. It is, therefore, not possible to determine clock bias to better than 25 nanosecond accuracy in the presence of a gravitational error of one part per million.

Grenchik, T. J.↗

Positions of three X-ray burst sources

Precise (20-30 arcsec) positions are reported for three steady X-ray sources that have been identified recently as X-ray burst sources: 4U (MXB) 1636-53, 4U 1728-33 (MXB 1728-34), and 4U (MXB) 1735-44. The positions were derived from data obtained with the SAS 3 rotating modulation collimators during a survey of the galactic plane. Possible optical counterparts are noted.

Jernigan, J. G.↗

Negative and positive cesium ion studies

Mass spectrometric analyses have been performed on the positive and negative species from discharges in Cs, He-Cs, and He-H2-Cs mixtures. Sampling was conducted through the electrodes of normal glow discharges and from close-spaced heated-cathode conditions, which approximate a cesium thermionic converter. No negative Cs ions were observed for Cs pressures less than .01 torr. Identified species included Cs(+), Cs2(+), Cs(-), and what appeared to be multiply charged ions. Low-mass negative and positive ions attributed to H2 were observed when an He-H2 mixture was also present in the discharge region.

Kuehn, D. G.↗

Rotation at 30 RPM about the Z axis after 6 hours in the 10-deg head-down position - Effect on susceptibility to motion sickness

Intraindividual differences in susceptibility to motion sickness were measured in 14 subjects for two conditions of rotation at 30 rpm in the 10-deg head-down position. In one condition, subjects were in the 10-deg head-down position for 6 h prior to the onset of rotation; in the other condition, the delay was only 15 min. In both conditions, there were changes in vital capacity, indicating a redistribution of movable body fluids. Subjects tended to be less susceptible to motion sickness when they were recumbent for 6 h prior to rotation. These results are counterevidence for the hypothesis that shifts of body fluid are responsible in large part for the motion sickness elicited in orbital space flight.

Graybiel, A.↗

Ambiguity resolution for satellite Doppler positioning systems

The implementation of satellite-based Doppler positioning systems frequently requires the recovery of transmitter position from a single pass of Doppler data. The least-squares approach to the problem yields conjugate solutions on either side of the satellite subtrack. It is important to develop a procedure for choosing the proper solution which is correct in a high percentage of cases. A test for ambiguity resolution which is the most powerful in the sense that it maximizes the probability of a correct decision is derived. When systematic error sources are properly included in the least-squares reduction process to yield an optimal solution the test reduces to choosing the solution which provides the smaller valuation of the least-squares loss function. When systematic error sources are ignored in the least-squares reduction, the most powerful test is a quadratic form comparison with the weighting matrix of the quadratic form obtained by computing the pseudoinverse of a reduced-rank square matrix. A formula for computing the power of the most powerful test is provided. Numerical examples are included in which the power of the test is computed for situations that are relevant to the design of a satellite-aided search and rescue system.

Argentiero, P.↗

Low-distortion resistive anodes for two-dimensional position-sensitive MCP systems

Microchannel plates (MCPs) are frequently used with resistive anodes to detect charged particles or photons and yield analog signals from which event positions can be decoded. The paper discusses a four-corner concave circular arc terminated resistive anode that permits theoretically distortionless encoding of Cartesian event positions into pulse charge ratios. The theory of the circular arc terminated anode is discussed along with anode design and performance. Electron beam images obtained by using such an anode are presented to confirm the usefulness of the approach.

Lampton, M.↗

Differential capacitance sensor as position detector for a magnetic suspension densimeter

In the present work, which consists of adapting a magnetic suspension densimeter for use at pressures up to 350 bars, a differential capacitance sensor is developed for use in the servosystem of a magnetic suspension densimeter for detecting the position of a magnetic buoy. This type of sensor has not been used previously in magnetic suspension densimeters. Its design, performance, and advantages are outlined. A cutaway drawing and a schematic diagram of the capacitance sensor and magnetic buoy are presented and described. The concentric-disk design of the sensor capacitor plates and the high degree of symmetry which results from the printed circuit fabrication approach minimize the sensor sensitivity to lateral displacement of the buoy and to the dielectric constant of the surrounding medium. A high-power microscope is necessary to monitor the position of the buoy relative to the support coil.

Frederick, N. V.↗

Solar cell angular position transducer

An angular position transducer utilizing photocells and a light source is disclosed. The device uses a fully rotatable baffle which is connected via an actuator shaft to the body whose rotational displacement is to be measured. The baffle blocks the light path between the light source and the photocells so that a constant semicircular beam of light reaches the photocells. The current produced by the photocells is fed through a resistor, a differential amplifier measures the voltage drop across the resistor which indicates the angular position of the actuator shaft and hence of the object.

Sandford, M. C.↗