Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Studies with cathode drift chambers for the GlueX experiment at Jefferson Lab

A drift chamber system consisting of 24 1 m-diameter chambers with both cathode and wire readout (total of 12,672 channels) is operational in Hall D at Jefferson Lab (Virginia). Two cathode strip planes and one wire plane in each chamber register the same avalanche allowing the study of avalanche development, charge induction process, and strip resolution. We demonstrate a method for reconstructing the two-dimensional distribution of the avalanche “center-of-gravity” position around the wire from an 55 Fe source with resolutions down to 30 μm. We estimate the azimuthal extent of the avalanche around the wire as a function of the total charge for an Ar/CO 2 gas mixture. By means of cluster counting using a modified 3 cm-gap chamber, we observe significant space charge effects within the same track, resulting in an extent of the avalanche along the wire.

42 ENGINEERING↗

A Possible Observation of Sigma-nn Continuum Structures and A Bound Sigma-NN State Using the (e, e 'K+) Reaction

The E12-17-003 (e, e'K+) experiment was carried out in the experimental Hall A facility of Jefferson Lab in November 2018. The experiment aimed at providing the experimental data for the unknown Lambda-n interaction by measuring the bound state or the resonance state as indicated by the HypHI experiment. The so obtained Lambda-n interaction was assumed to solve the existing charge symmetry breaking problem in the case of Lambda-N interaction. The experiment used Hall A high resolution spectrometers (both left and right spectrometers) positioned symmetrically at constant angle 13.2 deg. each. A 25 cm long aluminum cylinder filled with H-3 gas was used as a production target. The major calibration data were taken with the H target contained in an identical aluminum cylinder. The electroproduction of Lambda and Sigma^0 via p(e, e'K+)Lambda, Sigma^0 reactions was used to calibrate the absolute energy scale with the known masses of the Lambda and Sigma^0. Then by using the (e, e'K+) Sigma-reaction, two possible Lambda-nn resonance states and one NN bound state were observed. The observed states have the energy resolution about 1.6 MeV (FWHM), however, great r statistics are required to solidly confirm the observed states. The A = 3 and 4 Sigma bound states have been predicted long ago but only the A = 4 Sigma hypernucleus, that is He-4/Sigma, was found in the (K-, pi-) reaction. A careful Monte Carlo study was conducted to study the A (nuclear mass number) dependence on the missing mass resolution by using the identical experimental conditions. The simulated and experimentally obtained Lambda and Sigma^0 channels agreed within 100 keV in sigma, where sigma is the standard deviation. The intrinsic missing mass resolution of A = 3 (3/Lambda-n) resonance was predicted about sigma = 0.67 MeV with a natural width of about 0.6 MeV. However, due to the low statistics the precision does not permit sufficient constrain on the determination of the Lambda-n interaction. The reason of having such low statistics is due to the use of unoptimized Hall A system which was definitely feasible but not ideal for this experiment. In addition, the cross section was found to be much smaller than expected.

Pandey, Bishnu↗

On entropic uncertainty relations in the presence of a minimal length

Entropic uncertainty relations for the position and momentum within the generalized uncertainty principle are examined. Studies of this principle are motivated by the existence of a minimal observable length. Then the position and momentum operators satisfy the modified commutation relation, for which more than one algebraic representation is known. One of them is described by auxiliary momentum so that the momentum and coordinate wave functions are connected by the Fourier transform. However, the probability density functions of the physically true and auxiliary momenta are different. As the corresponding entropies differ, known entropic uncertainty relations are changed. Using differential Shannon entropies, we give a state-dependent formulation with correction term. State-independent uncertainty relations are obtained in terms of the Rényi entropies and the Tsallis entropies with binning. Such relations allow one to take into account a finiteness of measurement resolution. - Highlights: • Entropic uncertainty bounds increase for position and physically true momentum. • Correction terms are always nonzero for wave packets of a finite width. • An increase of uncertainty bounds depends on acceptance functions of apparatuses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BAZAAR DIPLOMACY: Examining Iran's Nuclear Bargaining Tactics

Since undeclared elements of Iran’s nuclear program were revealed in 2002, Tehran has engaged in a decade of efforts to justify and advance its nuclear program. Unlike North Korea’s withdrawal from the Nuclear Nonproliferation Treaty (NPT), Iran has maximized advantage and minimized backlash by maneuvering near the borders of the NPT system. Iran has embraced a three-pronged approach to bargain with the international community: (1) divide international opposition, (2) delay international monitoring, negotiations, and sanctions, (3) and defy international monitoring, commitments, and pressure. Iran’s nuclear bargaining can be divided into several time periods, and Iran used divide, delay, and defy tactics in each period. During the first phase from 2003 to 2005, Iranian reformist leader Mohammad Khatami was more willing to negotiate with the international community, but his ability to negotiate was constrained domestically and particularly during his last year of leadership. Tehran mainly negotiated with the France, Germany, and the United Kingdom – the European 3 (EU-3) – to drive a wedge between European and U.S. pressures on Iran and to delay outside monitoring and prevent international sanctions. It is in this early period that Iran developed its range of divide, delay, and defy tactics. For divide, Iran negotiated with the EU-3 because Europe had a close and influential relationship with the United States, whereas other international actors such as Russia and China were powerful but could not form an united bloc against the U.S. Iran began to delay international monitoring of its nuclear program by creating hurdles for international inspectors, stalling requests for information, and not volunteering information but providing updates only when Iranian nuclear developments were exposed by other parties. Iranian diplomats also delayed negotiations and sanctions by framing talks, negotiating and responding slowly to offers, providing false hopes and the appearance of concessions before key international events and resolutions, and adopting temporary and shifting negotiating positions. To defy, Iran modified and razed nuclear sites to prevent detection, used legalistic and minimal interpretations to subvert commitments, argued for an international right to enrich uranium, and proclaimed a fatwa against nuclear weapons. After President Mahmoud Ahmadinejad came to power in 2005, Iran took a tougher stance internationally. Ahmadinejad and his cabinet did not provide major concessions to facilitate international negotiations, were less willing to seriously consider proposals to curb Iran’s nuclear program, and linked Iran’s nuclear program to sovereignty and national pride. Realizing that Europe was less optimistic about negotiations, Ahmadinejad leveraged Russia and China to Iran’s advantage. Both countries helped delay and dilute United Nations Security Council resolutions against Iran. Ahmadinejad employed more tactics to defy international monitoring and pressure. These tactics involved demonstrating Iran’s nuclear progress even as Tehran engaged in negotiations over its program. Iran also increased the cost of failed negotiations by sustaining and escalating regional and global tensions to coincide with international events and resolutions that criticized or condemned Iran’s nuclear program. The third and present phase of Iranian nuclear bargaining began during Ahmadinejad’s second term as president (2009-2012). During this period, Ahmadinejad’s power significant weakened and domestic turf wars made Iranian nuclear negotiations unpredictable and at times contradictory. Due to the domestic situation and the exhausting of successful divide and delay tactics, Iran began using more defy tactics. Iran, for example, considered enriching uranium to a higher percentage for naval reactors, warned of closing the Straits of Hormuz, and engaged in terrorist acts against the West and its allies. Currently, Iran’s range of bargaining options has narrowed, with many divide and delay tactics less useful since the international community has become more aware of Iranian efforts to stall and buy time. While Iran leaders have employed more acts of defiance, Iran’s ability to sustain its defy tactics are waning and it is still possible to prevent greater confrontation between Iran and the West.

99 GENERAL AND MISCELLANEOUS↗

Spatial and Time Coincidence Detection of the Decay Chain of Short-Lived Radioactive Nuclei

The quantum counting position sensitive pixel detector Timepix with per-pixel energy and time resolution enables to detect radioactive ions and register the consecutive decay chain by simultaneous position-and time-correlation. This spatial and timing coincidence technique in the same sensor is demonstrated by the registration of the decay chain {sup 8}He{yields}{sup {beta} 8}Li and {sup 8}Li{yields}{sup {beta}-} {sup 8}Be{yields}{alpha}+{alpha} and by the measurement of the {beta} decay half-lives. Radioactive ions, selectively obtained from the Lohengrin fission fragment spectrometer installed at the High Flux Reactor of the ILL Grenoble, are delivered to the Timepix silicon sensor where decays of the implanted ions and daughter nuclei are registered and visualized. We measure decay lifetimes in the range {>=}{mu}s with precision limited just by counting statistics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Comparison of Vanadate to a 2'-5' Linkage at the Active Site of a Small Ribozyme Suggests a Role for Water in Transition-State Stabilization

The potential for water to participate in RNA catalyzed reactions has been the topic of several recent studies. Here, we report crystals of a minimal, hinged hairpin ribozyme in complex with the transition-state analog vanadate at 2.05 A resolution. Waters are present in the active site and are discussed in light of existing views of catalytic strategies employed by the hairpin ribozyme. A second structure harboring a 2',5'-phosphodiester linkage at the site of cleavage was also solved at 2.35 A resolution and corroborates the assignment of active site waters in the structure containing vanadate. A comparison of the two structures reveals that the 2',5' structure adopts a conformation that resembles the reaction intermediate in terms of (1) the positioning of its nonbridging oxygens and (2) the covalent attachment of the 2'-O nucleophile with the scissile G+1 phosphorus. The 2',5'-linked structure was then overlaid with scissile bonds of other small ribozymes including the glmS metabolite-sensing riboswitch and the hammerhead ribozyme, and suggests the potential of the 2',5' linkage to elicit a reaction-intermediate conformation without the need to form metalloenzyme complexes. The hairpin ribozyme structures presented here also suggest how water molecules bound at each of the nonbridging oxygens of G+1 may electrostatically stabilize the transition state in a manner that supplements nucleobase functional groups. Such coordination has not been reported for small ribozymes, but is consistent with the structures of protein enzymes. Overall, this work establishes significant parallels between the RNA and protein enzyme worlds.

59 BASIC BIOLOGICAL SCIENCES↗

CHANDRA OBSERVATIONS OF FIVE INTEGRAL SOURCES: NEW X-RAY POSITIONS FOR IGR J16393-4643 AND IGR J17091-3624

The Chandra High Resolution Camera observed the fields of five hard X-ray sources in order to help us obtain X-ray coordinates with subarcsecond precision. These observations provide the most accurate X-ray positions known for IGR J16393-4643 and IGR J17091-3624. The obscured X-ray pulsar IGR J16393-4643 lies at R.A. (J2000) = 16{sup h}39{sup m}05.{sup s}47, and decl. = -46 Degree-Sign 42'13.''0 (error radius of 0.''6 at 90% confidence). This position is incompatible with the previously proposed counterpart 2MASS J16390535-4642137, and it points instead to a new counterpart candidate that is possibly blended with the Two Micron All Sky Survey star. The black hole candidate IGR J17091-3624 was observed during its 2011 outburst providing coordinates of R.A. = 17{sup h}09{sup m}07.{sup s}59, and decl. = -36 Degree-Sign 24'25.''4. This position is compatible with those of the proposed optical/IR and radio counterparts, solidifying the source's status as a microquasar. Three targets, IGR J14043-6148, IGR J16358-4726, and IGR J17597-2201, were not detected. We obtained 3{sigma} upper limits of, respectively, 1.7, 1.8, and 1.5 Multiplication-Sign 10{sup -12} erg cm{sup -2} s{sup -1} on their 2-10 keV fluxes.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative and three-dimensional assessment of holdup material

Nuclear material deposited in equipment, transfer lines, and ventilation systems of a processing facility is usually referred to as holdup. Operators need to know the location and amount of holdup in their facility for radiation safety and material accountability. In this work, we propose to use an array of detectors co-axial to the inspected pipe to measure the holdup material. This method is implementable into an automated system capable of crawling on surfaces and pipes of various curvatures, which would enable faster, easier, and more accurate holdup safeguards measurements. We first demonstrated that the current holdup assay procedure could lead to a non-negligible bias in the estimate of special nuclear material mass, due to the simplified assumption of deposited geometry introduced by the Generalized Geometry Holdup (GGH) model. The new approach consists of imaging the inner holdup material by characterizing the detector array’s response and unfolding it from the measured light output. Our experimental proof of principle consists of three NaI(Tl) detectors surrounding an aluminum pipe containing two cesium-137 ( 137 Cs) sources. We derived the source distribution inside the pipe by first calculating the detector response matrix using a method adaptive to the surface geometry of the object containing the measured holdup material. Creating a matrix of the detector array’s measured counts, we then proceed to solve an inverse problem, resulting in an accurately located source position and activity distribution within the response matrix’s spatial resolution. Furthermore, we then developed a simulated model of the envisioned experimental setup, which accurately described both the activity and position of the source in 2D. Finally, we extended our model onto a discretized three-dimensional model of the system, encompassing 36 detectors. The model was simulated to measure the source distribution and activity of multiple sources in pipes of varied geometries, which could then be conveniently translated to a real-time holdup measurement protocol. For the 3D simulation of four different source geometries, the model accurately localized the source position in 3D, while the activity retained a maximum relative error of ±5.32%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ON MEASURING THE COSMIC MICROWAVE BACKGROUND TEMPERATURE AT REDSHIFT 0.89

We report on a measurement of the temperature of the cosmic microwave background radiation field, T {sub CMB}, at z = 0.88582 by imaging HC{sub 3}N(3 <- 2) and (5 <- 4) absorption in the foreground galaxy of the gravitationally lens magnified radio source PKS 1830-211 using the Very Long Baseline Array and the phased Very Large Array. Low-resolution imaging of the data yields a value of T {sub rot} = 5.6{sup +2.5} {sub -0.9} K for the rotational temperature, T {sub rot}, which is consistent with the temperature of the cosmic microwave background at the absorber's redshift of 2.73(1 + z) K. However, our high-resolution imaging reveals that the absorption peak position of the foreground gas is offset from the continuum peak position of the synchrotron radiation from PKS 1830-211SW, which indicates that the absorbing cloud is covering only part of the emission from PKS 1830-211, rather than the entire core-jet region. This changes the line-to-continuum ratios, and we find T {sub rot} between 1.1 and 2.5 K, which is lower than the expected value. This shows that previous T {sub rot} measurements could be biased due to unresolved structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Intercomparison of gamma scattering, gammatography and radiography techniques for mild steel nonuniform corrosion detection

This paper focuses on the mild steel (MS) corrosion detection and intercomparison of results obtained by gamma scattering, gammatography, and radiography techniques. The gamma scattering non-destructive evaluation (NDE) method utilizes scattered gamma radiation for the detection of corrosion, and the scattering experimental setup is an indigenously designed automated personal computer (PC) controlled scanning system consisting of computerized numerical control (CNC) controlled six-axis source detector system and four-axis job positioning system. The system has been successfully used to quantify the magnitude of corrosion and the thickness profile of a MS plate with nonuniform corrosion, and the results are correlated with those obtained from the conventional gammatography and radiography imaging measurements. A simple and straightforward reconstruction algorithm to reconstruct the densities of the objects under investigation and an unambiguous interpretation of the signal as a function of material density at any point of the thick object being inspected is described. In this simple and straightforward method the density of the target need not be known and only the knowledge of the target material's mass attenuation coefficients (composition) for the incident and scattered energies is enough to reconstruct the density of the each voxel of the specimen being studied. The Monte Carlo (MC) numerical simulation of the phenomena is done using the Monte Carlo N-Particle Transport Code (MCNP) and the quantitative estimates of the values of signal-to-noise ratio for different percentages of MS corrosion derived from these simulations are presented and the spectra are compared with the experimental data. The gammatography experiments are carried out using the same PC controlled scanning system in a narrow beam, good geometry setup, and the thickness loss is estimated from the measured transmitted intensity. Radiography of the MS plates is carried out using 160 kV x-ray machine. The digitized radiographs with a resolution of 50 {mu}m are processed for the detection of corrosion damage in five different locations. The thickness losses due to the corrosion of the MS plate obtained by gamma scattering method are compared with those values obtained by gammatography and radiography techniques. The percentage thickness loss estimated at different positions of the corroded MS plate varies from 17.78 to 27.0, from 18.9 to 24.28, and from 18.9 to 24.28 by gamma scattering, gammatography, and radiography techniques, respectively. Overall, these results are consistent and in line with each other.

36 MATERIALS SCIENCE↗

Nanoposition sensors with superior linear response to position and unlimited travel ranges

With the advancement in nanotechnology, the ability of positioning/measuring at subnanometer scale has been one of the most critical issues for the nanofabrication industry and researchers using scanning probe microscopy. Commercial nanopositioners have achieved direct measurements at the scale of 0.01 nm with capacitive sensing metrology. However, the commercial sensors have small dynamic ranges (up to only a few hundred micrometers) and are relatively large in size (centimeters in the transverse directions to the motion), which is necessary for healthy signal detections but making it difficult to use on smaller devices. This limits applications in which large materials (on the scale of centimeters or greater) are handled with needs of subnanometer resolutions. What has been done in the past is to combine the fine and coarse translation stages with different dynamic ranges to simultaneously achieve long travel range and high spatial resolution. In this paper, we present a novel capacitive position sensing metrology with ultrawide dynamic range from subnanometer to literally any practically desired length for a translation stage. This sensor will greatly simplify the task and enhance the performance of direct metrology in a hybrid translational stage covering translation tasks from subnanometer to centimeters.

36 MATERIALS SCIENCE↗

An EPID based method for efficient and precise asymmetric jaw alignment quality assurance

Purpose: The aim of this work was to investigate the use of amorphous silicon electronic portal imaging devices (EPIDs) for regular quality assurance of linear accelerator asymmetric jaw junctioning. Methods: The method uses the beam central axis position on the EPID measured to subpixel accuracy found from two EPID images with 180 degree sign opposing collimator angles. Individual zero jaw position (''half-beam blocked'') images are then acquired and the jaw position precisely determined for each using penumbra interpolation. The accuracy of determining jaw position with the EPID method was measured by translating a block (simulating a jaw) by known distances, using a translation stage, and then measuring each translation distance with the EPID. To establish the utility of EPID based junction dose measurements, radiographic film measurements of junction dose maxima/minima as a function of jaw gap/overlap were made and compared to EPID measurements. Using the method, the long-term stability of zero jaw positioning was assessed for four linear accelerators over a 1-1.5 yr time period. The stability at nonzero gantry angles was assessed over a shorter time period. Results: The accuracy of determining jaw translations with the method was within 0.14 mm found using the translation stage [standard deviation (SD) of 0.037 mm]. The junction doses measured with the EPID were different from film due to the nonwater equivalent EPID scattering properties and hence different penumbra profile. The doses were approximately linear with gap or overlap, and a correction factor was derived to convert EPID measured junction dose to film measured equivalent. Over a 1 yr period, the zero jaw positions at gantry zero position were highly reproducible with an average SD of 0.07 mm for the 16 collimator jaws examined. However, the average jaw positions ranged from -0.7 to 0.9 mm relative to central axis for the different jaws. The zero jaw position was also reproducible at gantry 90 degree sign position with 0.1 mm SD variation with the mean jaw position offset from the gantry zero position consistently by 0.3-0.4 mm for the jaws studied. Conclusions: The EPID based method is efficient and yields more precise data on linear accelerator jaw positioning and reproducibility than previous methods. The results highlight that zero jaw positions are highly reproducible to a level much smaller than the displayed jaw resolution and that there is a need for better methods to calibrate the jaw positioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of submicron particles influenced by mixed biogenic and anthropogenic emissions using high-resolution aerosol mass spectrometry: results from CARES

The Carbonaceous Aerosols and Radiative Effects Study (CARES) took place in the Sacramento Valley of California in summer 2010. We present results obtained at Cool, CA, the T1 site of the project ({approx}40 km downwind of urban emissions from Sacramento), where we deployed an Aerodyne high resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) in parallel with complementary instrumentation to characterize the sources and processes of submicron particles (PM1). Cool is located at the foothill of the Sierra Nevada Mountains, where intense biogenic emissions are periodically mixed with urban outflow transported by daytime southwesterly winds from the Sacramento metropolitan area. The particle mass loading was low (3.0 {micro}gm{sup -3} on average) and dominated by organics (80% of the PM1 mass) followed by sulfate (9.9 %). Organics and sulfate appeared to be externally mixed, as suggested by their different time series (r2 = 0.13) and size distributions. Sulfate showed a bimodal distribution with a droplet mode peaking at {approx}400nm in vacuum aerodynamic diameter (Dva), and a condensation mode at {approx}150 nm, while organics generally displayed a broad distribution in 60-600nm (Dva). New particle formation and growth events were observed almost every day, emphasizing the roles of organics and sulfate in new particle growth, especially that of organics. The organic aerosol (OA) had a nominal formula of C{sub 1}H{sub 1.38}N{sub 0.004}O{sub 0.44}, thus an average organic mass-to-carbon (OM/OC) ratio of 1.70. Two different oxygenated OA (OOA, 90% of total OA mass) and a hydrocarbon-like OA (HOA, 10 %) were identified by Positive matrix factorization (PMF) of the high resolution mass spectra. The more oxidized MO-OOA (O/C = 0.54) corresponded to secondary OA (SOA) primarily influenced by biogenic emissions, while the less oxidized LO-OOA (O/C = 0.42) corresponded to SOA associated with urban transport. The HOA factor corresponded to primary emissions mainly due to local traffic. Twenty three periods of urban plumes from T0 (Sacramento) to T1 (Cool) were identified using the Weather Research and Forecasting model coupled with Chemistry (WRF-Chem). The average PM1 mass loading was much higher in urban plumes (3.9 {micro}gm{sup -3}) than in air masses dominated by biogenic SOA (1.8 {micro}gm{sup -3}). The change in OA mass relative to CO ({Delta}OA/{Delta}CO) varied in the range of 5-196 {micro}gm{sup -3} ppm{sup -1}, reflecting large variability in SOA production. The highest {Delta}OA/{Delta}CO were reached when urban plumes arrived at Cool in the presence of a high concentration of biogenic volatile organic compounds (BVOCs=isoprene+monoterpenes+2-methyl-3-buten-2- ol [MBO]+methyl chavicol). This ratio, which was 77 {micro}gm{sup -3} ppm{sup -1} on average when BVOCs > 2 ppb, is much higher than when urban plumes arrived in a low biogenic VOCs environment (28 {micro}gm{sup -3} ppm{sup -1} when BVOCs < 0.7 ppb) or during other periods dominated by biogenic SOA (40 {micro}gm{sup -3} ppm{sup -1}). The results from this study demon10 strate that SOA formation is enhanced when anthropogenic emissions interact with biogenic precursors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A multiphysics coupling framework for exascale simulation of fracture evolution in subsurface energy applications

Predicting the evolution of fractured media is challenging due to coupled thermal, hydrological, chemical and mechanical processes that occur over a broad range of spatial scales, from the microscopic pore scale to field scale. We present a software framework and scientific workflow that couples the pore scale flow and reactive transport simulator Chombo-Crunch with the field scale geomechanics solver in GEOS to simulate fracture evolution in subsurface fluid-rock systems. This new multiphysics coupling capability comprises several novel features. An HDF5 data schema for coupling fracture positions between the two codes is employed and leverages the coarse resolution of the GEOS mechanics solver which limits the size of data coupled, and is, thus, not taxed by data resulting from the high resolution pore scale Chombo-Crunch solver. The coupling framework requires tracking of both before and after coarse nodal positions in GEOS as well as the resolved embedded boundary in Chombo-Crunch. We accomplished this by developing an approach to geometry generation that tracks the fracture interface between the two different methodologies. The GEOS quadrilateral mesh is converted to triangles which are organized into bins and an accessible tree structure; the nodes are then mapped to the Chombo representation using a continuous signed distance function that determines locations inside, on and outside of the fracture boundary. The GEOS positions are retained in memory on the Chombo-Crunch side of the coupling. The time stepping cadence for coupled multiphysics processes of flow, transport, reactions and mechanics is stable and demonstrates temporal reach to experimental time scales. The approach is validated by demonstration of 9 days of simulated time of a core flood experiment with fracture aperture evolution due to invasion of carbonated brine in wellbore-cement and sandstone. We also demonstrate usage of exascale computing resources by simulating a high resolution version of the validation problem on OLCF Frontier.

97 MATHEMATICS AND COMPUTING↗

Effect of laser spectral bandwidth on coherent control of resonance-enhanced multiphoton-ionization photoelectron spectroscopy

The high-resolution (2 + 1) resonance-enhanced multiphoton-ionization photoelectron spectroscopy (REMPI-PS) can be obtained by measuring the photoelectron intensity at a given kinetic energy and scanning the single π phase step position. In this paper, we further demonstrate that the high-resolution (2 + 1) REMPI-PS cannot be achieved at any measured position of the kinetic energy by this measurement method, which is affected by the laser spectral bandwidth. We propose a double π phase step modulation to eliminate the effect of the laser spectral bandwidth, and show the advantage of the double π phase step modulation on achieving the high-resolution (2 + 1) REMPI-PS by considering the contributions involving on- and near-resonant three-photon excitation pathways.

74 ATOMIC AND MOLECULAR PHYSICS↗

Developing new optical imaging techniques for single particle and molecule tracking in live cells

Differential interference contrast (DIC) microscopy is a far-field as well as wide-field optical imaging technique. Since it is non-invasive and requires no sample staining, DIC microscopy is suitable for tracking the motion of target molecules in live cells without interfering their functions. In addition, high numerical aperture objectives and condensers can be used in DIC microscopy. The depth of focus of DIC is shallow, which gives DIC much better optical sectioning ability than those of phase contrast and dark field microscopies. In this work, DIC was utilized to study dynamic biological processes including endocytosis and intracellular transport in live cells. The suitability of DIC microscopy for single particle tracking in live cells was first demonstrated by using DIC to monitor the entire endocytosis process of one mesoporous silica nanoparticle (MSN) into a live mammalian cell. By taking advantage of the optical sectioning ability of DIC, we recorded the depth profile of the MSN during the endocytosis process. The shape change around the nanoparticle due to the formation of a vesicle was also captured. DIC microscopy was further modified that the sample can be illuminated and imaged at two wavelengths simultaneously. By using the new technique, noble metal nanoparticles with different shapes and sizes were selectively imaged. Among all the examined metal nanoparticles, gold nanoparticles in rod shapes were found to be especially useful. Due to their anisotropic optical properties, gold nanorods showed as diffraction-limited spots with disproportionate bright and dark parts that are strongly dependent on their orientation in the 3D space. Gold nanorods were developed as orientation nanoprobes and were successfully used to report the self-rotation of gliding microtubules on kinesin coated substrates. Gold nanorods were further used to study the rotational motions of cargoes during the endocytosis and intracellular transport processes in live mammalian cells. New rotational information was obtained: (1) during endocytosis, cargoes lost their rotation freedom at the late stage of internalization; (2) cargoes performed train-like motion when they were transported along the microtubule network by motor proteins inside live cells; (3) During the pause stage of fast axonal transport, cargoes were still bound to the microtubule tracks by motor proteins. Total internal reflection fluorescence microscopy (TIRFM) is another non-invasive and far-field optical imaging technique. Because of its near-field illumination mechanism, TIRFM has better axial resolution than epi-fluorescence microscopy and confocal microscopy. In this work, an auto-calibrated, prism type, angle-scanning TIRFM instrument was built. The incident angle can range from subcritical angles to nearly 90°, with an angle interval less than 0.2°. The angle precision of the new instrument was demonstrated through the finding of the surface plasmon resonance (SPR) angle of metal film coated glass slide. The new instrument improved significantly the precision in determining the axial position. As a result, the best obtained axial resolution was ~ 8 nm, which is better than current existing instruments similar in function. The instrument was further modified to function as a pseudo TIRF microscope. The illumination depth can be controlled by changing the incident angle of the excitation laser beam or adjusting the horizontal position of the illumination laser spot on the prism top surface. With the new technique, i.e., variable-illumination-depth pseudo TIRF microscopy, the whole cell body from bottom to top was scanned.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-126: Respiratory Gating Quality Assurance: A Simple Method to Achieve Millisecond Temporal Resolution

Purpose: Low temporal latency between a gating on/off signal and a linac beam on/off during respiratory gating is critical for patient safety. Although, a measurement of temporal lag is recommended by AAPM Task Group 142 for commissioning and annual quality assurance, there currently exists no published method. Here we describe a simple, inexpensive, and reliable method to precisely measure gating lag at millisecond resolutions. Methods: A Varian Real-time Position Management™ (RPM) gating simulator with rotating disk was modified with a resistive flex sensor (Spectra Symbol) attached to the gating box platform. A photon diode was placed at machine isocenter. Output signals of the flex sensor and diode were monitored with a multichannel oscilloscope (Tektronix™ DPO3014). Qualitative inspection of the gating window/beam on synchronicity were made by setting the linac to beam on/off at end-expiration, and the oscilloscope's temporal window to 100 ms to visually examine if the on/off timing was within the recommended 100-ms tolerance. Quantitative measurements were made by saving the signal traces and analyzing in MatLab™. The on and off of the beam signal were located and compared to the expected gating window (e.g. 40% to 60%). Four gating cycles were measured and compared. Results: On a Varian TrueBeam™ STx linac with RPM gating software, the average difference in synchronicity at beam on and off for four cycles was 14 ms (3 to 30 ms) and 11 ms (2 to 32 ms), respectively. For a Varian Clinac™ 21EX the average difference at beam on and off was 127 ms (122 to 133 ms) and 46 ms (42 to 49 ms), respectively. The uncertainty in the synchrony difference was estimated at ±6 ms. Conclusion: This new gating QA method is easy to implement and allows for fast qualitative inspection and quantitative measurements for commissioning and TG-142 annual QA measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gaussian kernel density functions for compositional quantification in atom probe tomography

Highlights: • A methodology for compositional quantification from atom probe tomography is proposed. • A probability density function p(x) given discrete data points is constructed. • Each atom approximated by a Gaussian function with a particular smoothing parameter. • Density Kernel functions are used to find the optimum smoothing parameter. • The method is validated by using simulated data of semiconductor materials. - Abstract: Atom probe tomography (APT) has the ability to identify the nature and position of single atoms in a material with an almost 3D atomic resolution. However, the quantification of the material composition requires an appropriate treatment of the discrete APT data. When the amount of atoms selected to quantify the composition is relatively small, the spatial resolution is enhanced but the statistical error worsens. Conversely, the increase in the number of atoms considered reduces the spatial resolution, but improving the statistics. We have developed a methodology to reach an optimum equilibrium between the positional and the statistical error in an unsupervised form using Gaussian Kernel density functions. The validity of the method has been tested using APT simulated data of semiconductor materials. It has been proved that the chemical quantification in these materials requires the appropriate selection of the smoothing parameter, obtained without user intervention. In addition, the results have been compared to the usual techniques for composition measurement from APT data (voxelization and proximity histograms), showing better precision for high spatial resolution. This work supplies a data driven methodology based in Gaussian Kernel density functions for the accurate quantification of the composition from APT data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗