Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pressure Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

An automated pressure data acquisition system for evaluation of pressure sensitive paint chemistries

An automated pressure data acquisition system for testing of pressure sensitive phosphorescent paints was designed, assembled, and tested. The purpose of the calibration system is the evaluation and selection of pressure sensitive paint chemistries that could be used to obtain global aerodynamic pressure distribution measurements. The test apparatus and setup used for pressure sensitive paint characterizations is described. The pressure calibrations, thermal sensitivity effects, and photodegradation properties are discussed.

Sealey, Bradley S.↗

High temperature creep model development using in-situ 3-D DIC techniques during a simulated LOCA transient

In-situ strain measurements of fuel cladding can enable high-throughput data collection and validation to support accelerated qualification of cladding materials. Here, in this work, 3D digital image correlation was used to map strain for both Zircaloy-4 (Zry-4) and Cr-coated Zry-4 during two types of cladding rupture experiments: isobaric temperature ramp tests at 5 °C/s and isothermal pressure jump tests at 600 °C. Zry-4 strain data initially showed a temperature dependence expected for creep deformation, yet a shift to a new plastic deformation mechanism not reported in literature dominated during the finals seconds prior to rupture. Cr-coated Zry-4 did not show the change in deformation mechanism at the end of life and showed a delay in measurable creep deformation. Stress dependences were similar for Zry-4 and Cr/Zry-4 during pressure jump tests. Cr-coatings were found to decrease the strain rate during both testing scenarios. Creep parameters were calculated to support modelling efforts regarding design basis accidents.

36 MATERIALS SCIENCE↗

Two-dimensional cold-air cascade study of a film-cooled turbine stator blade. 1: Experimental results of pressure-surface film cooling tests

The effect of film coolant ejection from the pressure side of a stator blade was determined in a two-dimensional cascade. Stator exit surveys were made for each of six rows of coolant holes. Successive multirow tests were made with two, three, four, five, and six rows of coolant holes open. The results of the multirow tests are compared with the predicted multirow performance obtained by adding the single-row data. Results are presented in terms of stator primary-air efficiency as a function of coolant fraction.

Moffitt, T. P.↗

Implications of Dynamic Pressure Transducer Mounting Variations on Measurements in Pyrotechnic Test Apparatus

Accurate dynamic pressure measurements are often difficult to make within small pyrotechnic devices, and transducer mounting difficulties can cause data anomalies that lead to erroneous conclusions. Delayed initial pressure response followed by data ringing has been observed when using miniaturized pressure transducer mounting adapters required to interface transducers to small test chambers. This delayed pressure response and ringing, combined with a high data acquisition rate, has complicated data analysis. This paper compares the output signal characteristics from different pressure transducer mounting options, where the passage distance from the transducer face to the pyrotechnic chamber is varied in length and diameter. By analyzing the data and understating the associated system dynamics, a more realistic understanding of the actual dynamic pressure variations is achieved. Three pressure transducer mounting configurations (elongated, standard, and face/flush mount) were simultaneously tested using NASA standard initiators in closed volume pressure bombs. This paper also presents results of these pressure transducer mounting configurations as a result of a larger NASA Engineering and Safety Center pyrovalve test project. Results from these tests indicate the improved performance of using face/flush mounted pressure transducers in this application. This type of mounting improved initial pressure measurement response time by approximately 19 s over standard adapter mounting, eliminating most of the lag time; provided a near step-function type initial pressure increase; and greatly reduced data ringing in high data acquisition rate systems. The paper goes on to discuss other issues associated with the firing and instrumentation that are important for the tester to understand.

Dibbern, Andreas↗

Flight testing of a luminescent surface pressure sensor

NASA ARC has conducted flight tests of a new type of aerodynamic pressure sensor based on a luminescent surface coating. Flights were conducted at the NASA ARC-Dryden Flight Research Facility. The luminescent pressure sensor is based on a surface coating which, when illuminated with ultraviolet light, emits visible light with an intensity dependent on the local air pressure on the surface. This technique makes it possible to obtain pressure data over the entire surface of an aircraft, as opposed to conventional instrumentation, which can only make measurements at pre-selected points. The objective of the flight tests was to evaluate the effectiveness and practicality of a luminescent pressure sensor in the actual flight environment. A luminescent pressure sensor was installed on a fin, the Flight Test Fixture (FTF), that is attached to the underside of an F-104 aircraft. The response of one particular surface coating was evaluated at low supersonic Mach numbers (M = 1.0-1.6) in order to provide an initial estimate of the sensor's capabilities. This memo describes the test approach, the techniques used, and the pressure sensor's behavior under flight conditions. A direct comparison between data provided by the luminescent pressure sensor and that produced by conventional pressure instrumentation shows that the luminescent sensor can provide quantitative data under flight conditions. However, the test results also show that the sensor has a number of limitations which must be addressed if this technique is to prove useful in the flight environment.

Mclachlan, B. G.↗

Temperature and pressure measurement techniques for an advanced turbine test facility

A high pressure, high-temperature turbine test facility constructed for use in turbine cooling research is described. Several recently developed temperature and pressure measuring techniques are used in this facility. The measurement techniques, their status, previous applications and some results are discussed. Noncontact surface temperature measurements are made by optical methods. Radiation pyrometry principles combined with photoelectric scanning are used for rotating components and infrared photography for stationary components. Contact (direct) temperature and pressure measurements on rotating components are expected to be handled with an 80 channel rotary data package which mounts on and rotates with the turbine shaft at speeds up to 17,500 rpm. The data channels are time-division multiplexed and converted to digital words in the data package. A rotary transformer couples power and digital data to and from the shaft.

Pollack, F. G.↗

Temperature and pressure measurement techniques for an advanced turbine test facility

A high pressure, high-temperature turbine test facility is being constructed at the NASA Lewis Research Center for use in turbine cooling research. Several recently developed temperature and pressure measuring techniques will be used in this facility. This paper describes these measurement techniques, their status, previous applications and some results. Noncontact surface temperature measurements will be made by optical methods. Radiation pyrometry principles combined with photoelectric scanning will be used for rotating components and infrared photography for stationary components. Contact (direct) temperature and pressure measurements on rotating components will be handled with an 80-channel rotary data package which mounts on and rotates with the turbine shaft at speeds up to 17,500 rpm. The data channels are time-division multiplexed and converted to digital words in the data package. A rotary transformer couples power and digital data to and from the shaft.

Pollack, F. G.↗

Wind-Tunnel Investigation of Shielded Horn Balances and Tabs on a 0.7-Scale Model of XF6F Vertical Tail Surface

Results of subject tests indicate the difficulty of obtaining closely balanced rudder surfaces for most tail assemblies with shielded horns and maintaining a near zero rate-of-change of hinge-moment coefficient without an additional balancing device. A comparison is made between shielded and unshielded horn test results. Pressure distribution and tuft tests of flow over different shaped horns showed higher critical speed for medium-taper nosed horn. The trim tab nose shape had little effect on tab test results.

CONTROL SURFACES, BALANCED-HORN↗

Wind-Tunnel Tests of Seven Static-Pressure Probes at Transonic Speeds

Wind-tunnel tests have been conducted to determine the errors of 3 seven static-pressure probes mounted very close to the nose of a body of revolution simulating a missile forebody. The tests were conducted at Mach numbers from 0.80 to 1.08 and at angles of attack from -1.7 deg to 8.4 deg. The test Reynolds number per foot varied from 3.35 x 10(exp 6) to 4.05 x 10(exp 6). For three 4-vane, gimbaled probes, the static-pressure errors remained constant throughout the test angle-of-attack range for all Mach numbers except 1.02. For two single-vane, self-rotating probes having two orifices at +/-37.5 deg. from the plane of symmetry on the lower surface of the probe body, the static-pressure error varied as much as 1.5 percent of free-stream static pressure through the test angle-of- attack range for all Mach numbers. For two fixed, cone-cylinder probes of short length and large diameter, the static-pressure error varied over the test angle-of-attack range at constant Mach numbers as much as 8 to 10 percent of free-stream static pressure.

Capone, Francis J.↗

Space Shuttle Main Engine instrumented High Pressure Oxidizer Turbopump technology test bed testing results summary

This paper presents the test results from the Space Shuttle Main Engine (SSME) instrumented High Pressure Oxidizer Turbopump (HPOTP). The turbopump was tested on Engine 3001, a highly instrumented engine, in an effort to characterize the turbopump and the engine system. Seven tests, for a total duration of 766 seconds, were performed over a five month time period. The testing was performed at a wide variety of engine conditions. Changes in engine mixture ratio, power level, engine inlet oxidizer pressure, engine inlet fuel pressure, and engine start sequence were made. A discussion of all the HPOTP pressure and temperature data obtained are presented with comparisons to supporting analyses made where applicable. The effect of the various engine conditions on the measured data is addressed. This paper also discusses the challenges that were overcome to obtain the data. The significant instrumentation related problems encountered during the design, fabrication, and testing of this turbopump are summarized. Only those issues that affected the data obtained or the instrumentation itself are discussed. The relevance of the data to other noninstrumented turbomachinery is outlined. Conclusions and recommendations resulting from the test series will be presented.

Koelbl, Mary E.↗

Small, high-pressure ratio compressor mechanical acceptance test, volume 2

The fabrication and mechanical testing of the high-pressure-ratio compressor are reported. Mechanical testing was performed to demonstrate overspeed capability, adequate rotor dynamics, electrical isolation of the gas bearing trunnion mounted diffuser and shroud and the effect of operating parameters (speed and pressure ratio) on clearance of the compressor test rig. The speed range covered was 20 to 120 percent of rated speed (80,000 rpm). Following these tests an acceptance test which consisted of a 5 hour run at 80,000 rpm was made with approximately design impeller to shroud clearances. For Vol. 1, see N73-26483.

Metty, G. R.↗

Integration time required to extract accurate static and dynamic data from transonic wind-tunnel tests

Because the forces and pressures on wind-tunnel models tested at transonic speeds are not steady, even for 'static' aerodynamic tests, integration time is required to obtain data of acceptable accuracy. The integration time required for both static and dynamic tests is evaluated analytically and confirmed by experimental measurements. It is shown that, for static and dynamic tests, the accuracy obtained is a function of integration time, frequency content of the signal, and the ratio of the dynamic amplitude to the full signal of interest. In addition, for the dynamic case, the frequency band width used in analysis is important. Results of this study indicate that, for typical data accuracy desired from models in a large transonic wind tunnel (11- by 11-ft), up to the following integration times are required: static force and moment tests, 0.5 sec; static pressure tests, 0.1 sec; flutter tests, 30 to 60 sec; and random-dynamic tests, 10 sec.

Muhlstein, L., Jr.↗

Integration Time Required to Extract Accurate Data from Transonic Wind-Tunnel Tests

Because the forces and pressures on wind-tunnel models tested at transonic speeds are not steady, even for static aerodynamic tests, integration time is required to obtain data of acceptable accuracy. The integration time required for both static and dynamic tests is evaluated analytically and confirmed by experimental measurements. It is shown that, for static and dynamic tests, the accuracy obtained is a function of integration time, frequency of the signal, and the ratio of the dynamic amplitude to the full signal of interest. In addition, for the dynamic case, the frequency bandwidth used in analysis is important. Results of this study indicate that, for typical data accuracy desired from models in a large transonic wind tunnel (11- by 11-ft), up to the following integration times are required: static force and moment tests, 0.5 s; static pressure tests, 1 s; flutter tests, 30 to 60 s; and random-dynamic tests, 10 s.

Muhlstein, Lado, Jr.↗

Simulating Pressure Effects of High-Flow Volumes

Dynamic test stresses realized without high-volume pumps. Assembled in Sections in gas-flow passage, contoured mandrel restricts flow rate to valve convenient for testing and spatially varies pressure on passage walls to simulate operating-pressure profile. Realistic test pressures thereby achieved without extremely high flow volumes.

Kaufman, M.↗