Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pressure interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Trielectrode capacitive pressure transducer

A capacitive transducer and circuit especially suited for making measurements in a high-temperature environment are described. The transducer includes two capacitive electrodes and a shield electrode. As the temperature of the transducer rises, the resistance of the insulation between the capacitive electrode decreases and a resistive current attempts to interfere with the capacitive current between the capacitive electrodes. The shield electrode and the circuit coupled there reduce the resistive current in the transducer. A bridge-type circuit coupled to the transducer ignores the resistive current and measures only the capacitive current flowing between the capacitive electrodes.

Coon, G. W.↗

Residual interference and wind tunnel wall adaption

Measured flow variables near the test section boundaries, used to guide adjustments of the walls in adaptive wind tunnels, can also be used to quantify the residual interference. Because of a finite number of wall control devices (jacks, plenum compartments), the finite test section length, and the approximation character of adaptation algorithms, the unconfined flow conditions are not expected to be precisely attained even in the fully adapted stage. The procedures for the evaluation of residual wall interference are essentially the same as those used for assessing the correction in conventional, non-adaptive wind tunnels. Depending upon the number of flow variables utilized, one can speak of one- or two-variable methods; in two dimensions also of Schwarz- or Cauchy-type methods. The one-variable methods use the measured static pressure and normal velocity at the test section boundary, but do not require any model representation. This is clearly of an advantage for adaptive wall test section, which are often relatively small with respect to the test model, and for the variety of complex flows commonly encountered in wind tunnel testing. For test sections with flexible walls the normal component of velocity is given by the shape of the wall, adjusted for the displacement effect of its boundary layer. For ventilated test section walls it has to be measured by the Calspan pipes, laser Doppler velocimetry, or other appropriate techniques. The interface discontinuity method, also described, is a genuine residual interference assessment technique. It is specific to adaptive wall wind tunnels, where the computation results for the fictitious flow in the exterior of the test section are provided.

Mokry, Miroslav↗

Estimation of sensor measurement errors in reactor coolant systems using multi-sensor fusion

A nuclear power plant is typically instrumented with a variety of sensors to continually monitor its variables, and their sensor’s measurements may be used to assess the plant state and initiate safety actions, if needed. Errors in sensor measurements, due to factors such as calibration drifts, critically affect such state assessments. Here, we address a problem of estimating sensor errors using physics-informed machine learning methods that use measurements collected under known plant conditions. For a given sensor, we propose an information fusion method that uses measurements from other sensors to estimate its output assuming it is error-free and provides its difference from an actual measurement as an error estimate. We present the ensemble of trees and support vector machine fusers, and evaluate their performance using measurements collected over an emulated test loop of a pressurized water reactor. The plant variables are related to each other through the underlying physical laws under inertial constraints that place bounds on their derivatives, which analytically justify the applicability of machine learning methods for computing these fusers. Under twenty scenarios, we assess their sensor error estimates for pressure sensors of the heat exchanger of a reactor’s primary coolant system. Multiple types of errors are captured by both fusers under externally induced calibration drifts, blockages, minor leaks and air gaps in sensing lines, and electromagnetic interference; the root mean square error of the estimation of error is under 2.2% percent of the maximum measurement. We present generalization equations, in the framework of statistical learning theory, for these methods that characterize the confidence probability that the estimation error is bounded by a specified parameter in future test scenarios.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

HFIR SiC Bowing Test Ready to Insert

This report describes the successful assembly of a High Flux Isotope Reactor (HFIR) irradiation experiment designed to assess radiation-induced lateral bowing of silicon carbide fiber–reinforced, silicon carbide matrix composite (SiC/SiC) components under a radial fast neutron flux gradient. Excessive bowing of a SiC/SiC channel box in a boiling water reactor could potentially interfere with control blade movements. Similar concerns exist for SiC/SiC fuel cladding in light water reactors. The experiment described herein will provide experimental validation of the structural response of a miniature SiC/SiC channel box and tube specimens with pressurized water reactor diameters during irradiation. The significant radial fast neutron flux gradients that exist in the permanent reflector of HFIR were characterized using detailed three-dimensional neutronic calculations. The three-dimensional displacement damage dose rate profile and the resulting volumetric swelling in SiC were used as inputs to structural analyses that predicted the deformation and stresses in the channel box specimen. The specimens were thoroughly characterized prior to irradiation using traditional dimensional inspection and surface profilometry so that these measurements can later be compared with similar measurements that will be made post-irradiation to determine radiation-induced deformations. Furthermore, fine engraving markers were inscribed along all outer surfaces of the specimen and mapped using a digital microscope and a three-dimensional stage. This technique allowed for accurate measurements of the marker spacings, which can be compared with similar measurements that will be made post-irradiation to provide local radiation-induced strain mapping. The experiment was successfully assembled and is scheduled for insertion during HFIR cycle 492, which is currently scheduled to run from May 25, 2021 to June 18, 2021.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Does the Hood Canal Bridge traffic noise affect migrating steelhead smolts?

Recent research conducted by NOAA’s Manchester Research Laboratory has provided strong evidence of a substantial migration interference and increased mortality risk associated with the Hood Canal Bridge , which drives the need to investigate the sound and vibration generated by the vehicles crossing the bridge. A month-long monitoring of in-water sound pressure and the vibration of the bridge pontoons was performed at the Hood Canal Bridge by three sets of autonomous sound and vibration recording systems deployed along the bridge. At each deployment site, sound pressure in water was recorded by a hydrophone submerged three meters under water, and the vibration of the bridge pontoon was recorded by an array of three orthogonally mounted single-axis accelerometers. Both sound pressure and acceleration data were analyzed and compared to the threshold levels suggested by previous studies. Results show that the observed sound pressure levels and particle accelerations are strongly correlated with traffic volume across the bridge, and particle accelerations occasionally exceeded the threshold levels that could elicit the avoidance behavior of juvenile salmon. It is concluded that the Hood Canal Bridge traffic noise can potentially affect migrating salmonids due to the intense particle accelerations caused by the bridge pontoons in water.

Zang, Xiaoqin↗

Could Microplasma Ionization and Ultrahigh Mass Resolution Alleviate Chemical Separations for Elemental and Isotopic Analysis?

At the extremes, all analytical spectrometric measurements are limited by the resolution of the spectrometer system. Spectral overlaps, isobars in the case of mass spectrometry, can lead to the implementation of complex and time-consuming chemical separations to alleviate those interferences. In the area of elemental/isotopic mass spectrometry, use of sector-field instruments can provide a mass resolution of ~10,000, but still necessitate chemical separations. Described here is the coupling of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to ultra-high resolution Orbitrap mass analyzer systems to yield mass resolution values ranging from 70k to 1M. Resolution of this order, with commensurate improvements in precision and accuracy, holds the promise to affect elemental/isotopic determinations without the need for chemical separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Work function determination of promising electrode materials for thermionic converters

Work performed on this contract was primarily for the evaluation of selected electrode materials for thermionic energy converters. The original objective was to characterize selected nickel based superalloys up to temperatures of 1400 K. It was found that an early selection, Inconel 800 produced a high vapor pressure which interfered with the vacuum emission measurements. The program then shifted to two other areas. The first area was to obtain emission from the superalloys in a cesiated atmosphere. The cesium plasma helps to suppress the vaporization interference. The second area involved characterization of the Lanthanum-Boron series as thermionic emitters. These final two areas resulted in three journal publications which are attached to this report.

Jacobson, D.↗

Characteristics of a separating confluent boundary layer and the downstream wake

Measurements of pressure and velocity characteristics are presented and analyzed for flow over and downstream of a NACA 4412 airfoil equipped with a NACA 4415 single-slotted flap at high angle of attack and close to maximum lift. The flow remained attached over the main element while a large region of recirculating flow occurred over the aft 61 percent of the flap. The airfoil configuration was tested at a Mach number of 0.09 and a chord Reynolds number of 1.8x10 to the 6th power in the NASA Ames Research Center 7- by 10-Foot Wind Tunnel. Measurement of mean and fluctuation velocities were obtained in regions of recirculation and high turbulence intensity using 3-D laser velocimetry. In regions where the flow had a preferred direction and relatively low turbulence intensity, hot-wire anemometry was used. Emphasis was placed on obtaining characteristics in the confluent boundary layer, the region of recirculating flow, and in the downstream wake. Surface pressure measurements were made on the main airfoil, flap, wind tunnel roof and floor. It is thought likely that because the model is large when compared to the wind tunnel cross section, the wind tunnel floor and ceiling interference should be taken into account when the flow field is calculated.

Adair, Desmond↗

Test results at transonic speeds on a contoured over-the-wing propfan model

A semispan wing/body model with a powered highly loaded propeller has been tested to provide data on the propulsion installation drag of advanced propfan-powered aircraft. The model had a supercritical wing with a contoured over-the-wing nacelle. It was tested in the Ames Research Center's (ARC) 14-foot Transonic Wind Tunnel at a total pressure of 1 atm. The test was conducted at angles of attack from -0.5 to 4 deg at Mach numbers ranging from 0.6 to 0.8. The test objectives were to determine propeller performance, exhaust jet effects, propeller slipstream interference drag, and total powerplant installation drag. Test results indicated a total powerplant installation drag of 82 counts (0.0082) at a Mach number of 0.8 and a lift coefficient of 0.5, which is approximately 29 percent of a typical airplane cruise drag.

Levin, Alan D.↗

An Analysis of Thrust Normalization of Ground Flowfield Pressures, Temperatures, and Velocities, for an AV-8B -408 Harrier During Hover

An external environment test for an AV-8B Harrier during hover and vertical operations was conducted at NAWCAD at Patuxent River, Maryland in July 1997. Four boundary layer rakes were instrumented with static and total pressures, and thermocouples for measuring temperatures. These rakes were installed at 30, 50, 75, and 100 foot from the hover center. The 50 ft and 100 ft rakes were offset 20 deg from the other two to minimize interference effects. In order to measure a complete flowfield footprint, it was necessary to have the Harrier change its heading relative to the rakes from 0 to 180 deg. A 20 deg increment in azimuth was used. This permitted the four rakes to measure the flowfield at 72 locations relative to the aircraft. However, as the Harrier burns fuel, the hover thrust must be reduced by the pilot in order to maintain a constant height above ground. The typical test procedure employed was: (1) vertical takeoff at an initial heading; (2) 20 second hover dwell at that heading; (3) pedal turn to a second heading, followed by a 20 second dwell hover; (4) pedal turn to a third heading, followed by a 20 second dwell hover; and (5) vertical landing at the third heading. Additional information is contained in the original extended abstract.

Naumowicz, Tim↗

Controlling Triboelectrification Effects on Spacecraft Ethernet Cabling

Triboelectric charging of a spacecraft and launch vehicles on ascent may occur due to the process of contact and separation between the vehicle skin and aerosols, dust, ice, water droplets, smoke, and other particulates encountered in the flight path. Depending on characteristics at the atomic and molecular levels of the vehicle skin’s surface and the substances and particulates encountered, electrical charge will transfer between the vehicle and the encountered substances, resulting in an accumulation of electrical charge on the vehicle skin. If the vehicle skin is conductive and electrically bonded such that in its entirety it presents an equipotential surface, then the accumulated electrical charge will spread in a nearly uniform manner leaving all regions with a nearly equal potential with respect to each other and the surrounding environment. Regions that are not electrically bonded as described, or surfaces that have resistivity values, can reach different potentials than the surrounding surfaces. When this happens, the differing potentials may grow to very large magnitudes, leading to electrostatic discharge events between the regions. As the vehicle rises in altitude, the breakdown potential between these regions of differing potential decreases commensurate with decreases in atmospheric density and pressure. If the potential differences between surfaces of the vehicle become equal to or exceed the breakdown potential, one or more discharge events may occur, each of them generating voltage and current transients that can easily damage or interfere with the designed operation of on-board electrical, avionic, and communications and navigation systems. This lesson learned discusses an in-flight anomaly caused by triboelectric discharge events and exacerbated by the lack of adequate cable shielding that affected flight computer communication links. Also discussed are mitigations to prevent this occurrence.

Ethernet↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Molten Salt Lattice Confinement Fusion (LCF) Fast Fission Reactor for Lunar and Planetary Surface Power

Molten salt fission reactors (MSR) have been suggested for lunar and planetary surface power systems. They have the advantage of operating at high temperature, for efficient thermal-electrical conversion, low pressure, long-lived with high nuclear fuel burnup. MSR are often designed to breed fissile 233U from natural 232Th by neutron capture and  decay via: 232Th(n,)233Th(,)233Pa(,)233U Unfortunately, this process requires 233Pa isotope separation and segregation to decay to 233U. This requirement prevents additional neutron capture that interferes with 233U breeding. Instead, Wooley’s sub-critical, fast fission, molten salt reactor would use externally generated tokamak fusion neutrons1,2 to fission all actinides.We propose a simpler fusion-fast-fission sub-critical reactor that generates fast neutrons in situ from lattice confinement fusion (LCF) to fission fertile and fissile actinides. This hybrid reactor doesn't require enriched 235U fissile pins to initiate fis-sion reactions, nor 233Pa separation and segregation during operation. Like Wooley’s, this hybrid reactor “burns” natural uranium (238U) or thorium (232Th) which avoids uranium enrichment and additional fissile material launch safety and security costs. The LCF neutron source is initiated by bremsstrahlung photoneutrons (Fig. 1)3 or isotopic neutron sources in electron-screened lattices (Fig. 2)4,5. Alternatively, the electrolytic Pd-deuterium co-deposition6protocol fast fissions7 both 232Th and 238U. However, an aqueous electrolyte-based system, without pressurization similar to conventional pressurized water fission reactors, is incapable of high temperatures due to the boiling point of the electrolyte slightly over 100 C. Molten salts can be used instead as was demonstrated at the University of Hawaii8 using a variety of Ni and Pd cathodes in lithiated, hydrided and deuterated salts. These salts have melting points often exceeding 500C making them suitable to efficiently produce electrical power9 through either Advanced Stirling Genera-tors (< 100 kWe) or closed-Brayton Cycle (> 100 kWe). This hybrid reactor could power a wide range of lunar or Martian applications from unmanned in-struments, to charging vehicles and entire facilities such as human habitats or in situ resource utilization. The power conversion cycles are Carnot Cycle limited, but generally 30% efficient at best. However, waste heat on the moon or Mars is important to surviving either two-week lunar nights or Martian nights as well as providing process heat for mineral extraction and “living off the land”

Lawrence Forsley↗

Parametric optimization of the liquid sampling-atmospheric pressure glow discharge ionization source coupled to an Orbitrap mass spectrometer for neodymium isotope ratio determinations

Isotope ratio determinations are a valuable tool in several application areas. In nuclear forensics, the isotope ratios of uranium and plutonium are commonly used as a signature for the nuclear material's provenance and processing history. However, signatures from other coexisting elements, such as neodymium and samarium, can offer additional insights. Here, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source coupled to an Orbitrap mass spectrometer (MS) has demonstrated its utility for actinide measurements. This instrumental platform can leverage the high resolution offered by the Orbitrap MS to overcome potential isobaric interferences, such as 144 Nd- 144 Sm, 148 Nd- 148 Sm, and 150 Nd- 150 Sm pairs. The work presented herein demonstrates the rapid, accurate, and precise determination of the isotope ratios for neodymium using the LS-APGD/Orbitrap MS. Both the LS-APGD and Orbitrap MS parameters were optimized systematically, with NdO + found to be the most abundant, most reduced species after applying the optimal collision-induced dissociation modalities. A limit of detection of 3 pg of 142 Nd was achieved when data was acquired and processed using the FTMS Booster, an external data acquisition and processing system offered by Spectroswiss. Excellent accuracy of better than 99 % and precision of <1 % RSD were achieved when a solution of the well-characterized neodymium standard (JNdi-1 standard) was analyzed under the optimized condition, indicating the LS-APGD/Orbitrap's great potential for isotope ratio analysis of Nd and other REEs for diverse applications.

47 OTHER INSTRUMENTATION↗

Sensor Drift Estimation for Reactor Systems by Fusing Multiple Sensor Measurements

A nuclear power plant is instrumented with a variety of sensors that monitor its variables to estimate the state and initiate safety actions, if needed. We address the problem of estimating drifts or errors in sensor measurements due to factors such as calibration changes. We propose an information fusion method that uses measurements from other sensors to generate an estimate of a sensor measurement, and its difference from an actual measurement provides an error estimate. We present two fusers based on the ensemble of trees and support vector machine that are trained using sensor measurements collected at an emulated test loop of a pressurized water reactor under no-drift conditions. We present error estimates for a differential pressure sensor of the heat exchanger of the primary coolant system, under twenty controlled scenarios using the test loop. Both positive and negative errors are captured by both methods in scenarios involving calibration drifts, blocking, air gap and electromagnetic interference. The root mean square errors of estimated drifts are typically within 2% percent of the maximum.

Rao, Nageswara↗

Transonic pressure and load distributions for a group of simulated launch vehicles

Pressure and load distributions for a related group of simulated launch vehicle configurations are presented. The configurations were selected so that the nose cone and interstage transition flare components were relatively close to one another and subject to mutual interference effects. Tests extended over a Mach number range from 0.40 to 1.20 at angles of attack from 0 deg to about 10 deg. The test Reynolds numbers, based on main stage diameter, were of the order of 0.00000098.

Kelly, T. C.↗

HO2 detection by near infrared absorption using tunable diode lasers

The strongest absorption lines are in the v sub 2 vibrational band around 1400/cm; several near-coincident line pairs in this region provide max linestrengths of 1.2 x 10 exp -20 sq. cm/(molecule*cm). High Frequency wavelength modulation coupled with sweep integration were used to minimize noise and maintain spectral discrimination. Reduced pressure sampling was performed using supersonic nozzle and an aerodynamic flow cell to minimize residence time and wall losses of radicals. The astigmatic mirror design provides pathlengths up to 200 m in volume of 3 liters with minimal optical interference fringes; longer pathlengths are possible. The detection limit depends on pathlength and minimum fractional absorptions.

Nelson, David↗