Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Finding order in a bustling construction zone: quantitative imaging and analysis of cell wall assembly in plants

Assembly of polysaccharide-based walls by plant cells involves the rapid synthesis, trafficking, and deposition of complex biopolymers, but how these events are controlled and coordinated to achieve a strong, resilient extracellular matrix has remained obscure for decades. Recent quantitative analyses of fluorescence microscopy data have revealed details of the trafficking and synthetic activity of cellulose synthases, and new methods for labeling matrix polymers have unveiled aspects of their regulated deposition in the wall. Detailed studies of the identity, architecture, activity, and trafficking of the proteins and protein complexes that synthesize wall polymers, combined with advances in image acquisition and analysis, will aid future efforts to dissect wall assembly.

biofuels (including algae and biomass), bio-inspir↗

The Effect Of Spectral Lines Choice For Depth Profiling LIPS Experiment

Laser-induced Plasma spectroscopy (LIPS) is a useful method for determining the elemental composition of various materials but for long time it have been mainly restricted to qualitative and quantitative analysis of samples material. Recently LIPS is applied in addition to depth-profile analysis. In this paper we were trying to investigate the differences in the depth profile, obtained adopting femtosecond LIPS, that may occur on changing the spectral lines chosen for the analysis. The used femtosecond laser has pulse duration of 130 fs, wave length of 795 nm and pulse energy 200 {mu}J. It was found that the differences observed were not significant as long as the spectral lines chosen are fulfilling the LIPS spectral lines conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-G-207-05: Relationship Between CT Image Quality, Segmentation Performance, and Quantitative Image Feature Analysis

Purpose: Segmentation quality can affect quantitative image feature analysis. The objective of this study is to examine the relationship between computed tomography (CT) image quality, segmentation performance, and quantitative image feature analysis. Methods: A total of 90 pathology proven breast lesions in 87 dedicated breast CT images were considered. An iterative image reconstruction (IIR) algorithm was used to obtain CT images with different quality. With different combinations of 4 variables in the algorithm, this study obtained a total of 28 different qualities of CT images. Two imaging tasks/objectives were considered: 1) segmentation and 2) classification of the lesion as benign or malignant. Twenty-three image features were extracted after segmentation using a semi-automated algorithm and 5 of them were selected via a feature selection technique. Logistic regression was trained and tested using leave-one-out-cross-validation and its area under the ROC curve (AUC) was recorded. The standard deviation of a homogeneous portion and the gradient of a parenchymal portion of an example breast were used as an estimate of image noise and sharpness. The DICE coefficient was computed using a radiologist’s drawing on the lesion. Mean DICE and AUC were used as performance metrics for each of the 28 reconstructions. The relationship between segmentation and classification performance under different reconstructions were compared. Distributions (median, 95% confidence interval) of DICE and AUC for each reconstruction were also compared. Results: Moderate correlation (Pearson’s rho = 0.43, p-value = 0.02) between DICE and AUC values was found. However, the variation between DICE and AUC values for each reconstruction increased as the image sharpness increased. There was a combination of IIR parameters that resulted in the best segmentation with the worst classification performance. Conclusion: There are certain images that yield better segmentation or classification performance. The best segmentation Result does not necessarily lead to the best classification Result. This work has been supported in part by grants from the NIH R21-EB015053. R Nishikawa is receives royalties form Hologic, Inc.

60 APPLIED LIFE SCIENCES↗

Spectral analysis of groove spacing on Ganymede

A quantitative analysis of groove spacing on Ganymede is described. Fourier transforms of a large number of photometric profiles across groove sets are calculated and the resulting power spectra are examined for the position and strength of peaks representing topographic periodicities. The geographic and global statistical distribution of groove wavelengths are examined, and these data are related to models of groove tectonism. It is found that groove spacing on Ganymede shows an approximately long-normal distribution with a minimum of about 3.5 km, a maximum of about 17 km, and a mean of 8.4 km. Groove spacing tends to be quite regular within a single groove set but can vary substantially from one groove set to another within a single geographic region.

Grimm, R. E.↗

The effect of school intervention programs on the body mass index of adolescents: a systematic review with meta-analysis

Abstract Effective obesity interventions in adolescent populations have been identified as an immediate priority action to stem the increasing prevalence of adult obesity. The purpose of this meta-analysis was to make a quantitative analysis of the impact of school-based interventions on body mass index during adolescence. Studies were retrieved from PubMed, Scopus, Science Direct and Web of Science databases. Results were pooled using a random-effects model with 95% confidence interval considered statistically significant. Of the 18 798 possible relevant articles identified, 12 articles were included in this meta-analysis. The global result showed a low magnitude effect, though it was statistically significant (N = 14 428), global e.s. = −0.055, P = 0.004 (95% CI = −0.092, −0.017). Heterogeneity was low among the studies (I2 = 9.017%). The funnel plot showed no evidence of publication bias. The rank-correlation test of Begg (P = 0.45641) and Egger’s regression (P = 0.19459) confirmed the absence of bias. This meta-analysis reported a significant effect favoring the interventions; however, future research are needed since the reported the evidence was of low magnitude, with the studies following a substantial range of approaches and mostly had a modest methodological quality.

Saavedra Dias, R.↗

Network Connectivity for Permanent, Transient, Independent, and Correlated Faults

This paper develops a method for the quantitative analysis of network connectivity in the presence of both permanent and transient faults. Even though transient noise is considered a common occurrence in networks, a survey of the literature reveals an emphasis on permanent faults. Transient faults introduce a time element into the analysis of network reliability. With permanent faults it is sufficient to consider the faults that have accumulated by the end of the operating period. With transient faults the arrival and recovery time must be included. The number and location of faults in the system is a dynamic variable. Transient faults also introduce system recovery into the analysis. The goal is the quantitative assessment of network connectivity in the presence of both permanent and transient faults. The approach is to construct a global model that includes all classes of faults: permanent, transient, independent, and correlated. A theorem is derived about this model that give distributions for (1) the number of fault occurrences, (2) the type of fault occurrence, (3) the time of the fault occurrences, and (4) the location of the fault occurrence. These results are applied to compare and contrast the connectivity of different network architectures in the presence of permanent, transient, independent, and correlated faults. The examples below use a Monte Carlo simulation, but the theorem mentioned above could be used to guide fault-injections in a laboratory.

White, Allan L.↗

Simulation of Transport Phenomena in Bubble Column Reactors

The production of carbon and hydrogen from methane is a viable pathway for monetizing the vast reserves of US natural gas. Liquid (metals and/or salts) bubble column reactors operating at temperatures greater than 1000° C allow the conversion of methane into hydrogen without CO 2 emission. The low-density carbon floats on top of the liquid surface, allowing an easier removal, compared to other reactor concepts for methane pyrolysis. In this current report, we present results from simulations of transport phenomena in a liquid bubble column reactor. The goal is to investigate and understand parameters that are crucial for bubble column reactor design and scale up. The report presents the formulation and numerical methods used in the multiphase direct numerical simulation software, Quilt. This software was validated for the bubbly flow using numerical and physics based test problems. Quilt was then used to perform simulations of the bubble column reactor as a parametric study, varying the bubble injection parameters. The simulations were visualized for qualitative analysis and followed up with a quantitative analysis. The effect of injection parameters on various quantitative measures of the bubble residence time, interfacial area and motion through the column are presented.

03 NATURAL GAS↗

Amino acid analysis

The process and apparatus for qualitative and quantitative analysis of the amino acid content of a biological sample are presented. The sample is deposited on a cation exchange resin and then is washed with suitable solvents. The amino acids and various cations and organic material with a basic function remain on the resin. The resin is eluted with an acid eluant, and the eluate containing the amino acids is transferred to a reaction vessel where the eluant is removed. Final analysis of the purified acylated amino acid esters is accomplished by gas-liquid chromatographic techniques.

Winitz, M.↗

The S-054 X-ray telescope experiment on Skylab

A description of the S-054 X-ray telescope on Skylab is presented with a discussion of the experimental objectives, observing program, data reduction and analysis. Some results from the Skylab mission are given. The telescope photographically records high-resolution images of the solar corona in several broadband regions of the soft X-ray spectrum. It includes an objective grating used to study the line spectrum. The spatial resolution, sensitivity, dynamic range and time resolution of the instrument were chosen to survey a wide variety of solar phenomena. It embodies improvements in design, fabrication, and calibration techniques which were developed over a ten-year period. The observing program was devised to optimize the use of the instrument and to provide studies on a wide range of time scales. The data analysis program includes morphological studies and quantitative analysis using digitized images. A small sample of the data obtained in the mission is presented to demonstrate the type of information that is available and the kinds of results that can be obtained from it.

Vaiana, G. S.↗

The Spectral Image Processing System (SIPS): Software for integrated analysis of AVIRIS data

The Spectral Image Processing System (SIPS) is a software package developed by the Center for the Study of Earth from Space (CSES) at the University of Colorado, Boulder, in response to a perceived need to provide integrated tools for analysis of imaging spectrometer data both spectrally and spatially. SIPS was specifically designed to deal with data from the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and the High Resolution Imaging Spectrometer (HIRIS), but was tested with other datasets including the Geophysical and Environmental Research Imaging Spectrometer (GERIS), GEOSCAN images, and Landsat TM. SIPS was developed using the 'Interactive Data Language' (IDL). It takes advantage of high speed disk access and fast processors running under the UNIX operating system to provide rapid analysis of entire imaging spectrometer datasets. SIPS allows analysis of single or multiple imaging spectrometer data segments at full spatial and spectral resolution. It also allows visualization and interactive analysis of image cubes derived from quantitative analysis procedures such as absorption band characterization and spectral unmixing. SIPS consists of three modules: SIPS Utilities, SIPS_View, and SIPS Analysis. SIPS version 1.1 is described below.

Kruse, F. A.↗

Building a Database for a Quantitative Model

A database can greatly benefit a quantitative analysis. The defining characteristic of a quantitative risk, or reliability, model is the use of failure estimate data. Models can easily contain a thousand Basic Events, relying on hundreds of individual data sources. Obviously, entering so much data by hand will eventually lead to errors. Not so obviously entering data this way does not aid linking the Basic Events to the data sources. The best way to organize large amounts of data on a computer is with a database. But a model does not require a large, enterprise-level database with dedicated developers and administrators. A database built in Excel can be quite sufficient. A simple spreadsheet database can link every Basic Event to the individual data source selected for them. This database can also contain the manipulations appropriate for how the data is used in the model. These manipulations include stressing factors based on use and maintenance cycles, dormancy, unique failure modes, the modeling of multiple items as a single "Super component" Basic Event, and Bayesian Updating based on flight and testing experience. A simple, unique metadata field in both the model and database provides a link from any Basic Event in the model to its data source and all relevant calculations. The credibility for the entire model often rests on the credibility and traceability of the data.

Kahn, C. Joseph↗

Q-Spectroscopy

A new tool for rapid single-particle analysis in safeguards is described. This quantitative analysis tool has advantages over conventional methods for isotopic analysis of actinide-bearing samples. The method can be used to determine chemical age via 241 Am/ 241 Pu ''atomic clock''.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

imageMCR

imageMCR is a user friendly software package that consists of a variety inputs to preprocess and analyze the hyperspectral image data using multivariate algorithms such as Multivariate Curve Resolution (MCR), Principle Component Analysis (PCA), Classical Least Squares (CLS) and Parallel Factor Analysis (PARAFAC). MCR provides a relative quantitative analysis of the hyperspectral image data without the need for standards, and it discovers all the emitting species (spectral pure components) present in an image, even those in which there is no a priori information. Once the spectral components are discovered, these spectral components can be used for future MCR analyses or used with CLS algorithms to quickly extract concentration image maps for each component within spectral image data sets.

Source record↗