Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

493 records · Page 28

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

Abstract The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $$^3$$ 3 He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the Ricochet experiment should reach a statistical significance of 4.6 to 13.6 $$\sigma $$ σ for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Mapping the dark matter in the NGC 5044 group with ROSAT: Evidence for a nearly homogeneous cooling flow with a cooling wake

The NGC 5044 group of galaxies was observed by the ROSAT Position Sensitive Proportional Counter (PSPC) for 30 ks during its reduced pointed phase (1991 July). Due to the relatively cool gas temperature in the group (kT = 0.98 +/- 0.02 keV) and the excellent photon statistics (65,000 net counts), we are able to determine precisely a number of fundamental properties of the group within 250 kpc of the central galaxy. In particular, we present model-independent measurements of the total gravitating mass, the temperature and abundance profiles of the gas, and the mass accretion rate. Between 60 and 250 kpc, the gas is nearly isothermal with T varies as r(exp (-0.13 +/- 0.03)). The total gravitating mass of the group can be unambiguously determined from the observed density and temperature profiles of the gas using the equation of hydrostatic equilibrium. Within 250 kpc, the gravitating mass is 1.6 x 10(exp 13) solar mass, yielding a mass-to-light ratio of 130 solar mass/solar luminosity. The baryons (gas and stars) comprise 12% of the total mass within this radius. At small radii, the temperature clearly increases outward and attains a maximum value at 60 kpc. The positive temperature gradient in the center of the group confirms the existence of a cooling flow. The cooling flow region extends well beyond the temperature maximum with a cooling radius between 100 and 150 kpc. There are two distinct regions in the cooling flow separated by the temperature maximum. In the outer region, the gas is nearly isothermal with a unifor m Fe abundance of approximately 80% solar, the flow is nearly homogeneous with dot-M= 20 to 25 solar mass/year, the X-ray contours are spherically symmetric, and rho(sub gas) varies as r(exp -1.6). In the inner region, the temperature profile has a positive gradient, the mass accretion rate decreases rapidly inward, the gas density profile is steeper, and the X-ray image shows some substrucutre. NGC 5044 is offset from the centroid of the outer X-ray contours indicating that the central galaxy may have a residual velocity with respect to the center of the group potential. There is also a linear X-ray feature with an extent of approximately 30 kpc with one end coincident with NGC 5044. The X-ray emission from this feature is softer than the ambient gas. We interpret this feature as a 'cooling wake' formed by the accreting gas as it is gravitationally focused into the wake of NGC 5044. One of the most surprising results of our PSPC observation is the discovery of a nearly homogeneous cooling flow. Prior results concerning the mass accretion profile in cooling flows indicate that dot-M varies as r. This relation implies that significant mass deposition occurs at large radii which generates an inhomogeneous flow. The mass accretion rate in the NGC 5044 group is essentially a constant beyond 40 kpc (well within the cooling radius). Significant mass deposition (a declining dot-M) does not commence until the gas accretes to within 40 kpc of the group center where the radiative cooling time is approximately equals 10(exp 9) year. Th is radius also corresponds to the temperature maximum, the break in gas density profile, and the onset of structure in the X-ray image. A Hubble constant of H(sub 0) = 50 km/sec/Mpc is used throughout the paper.

David, Laurence P.↗

Long-Term Health Risk Quantification

Astronauts face hazards during spaceflight, including space radiation exposure, isolation and confinement, traveling far distances from Earth, reduced gravity levels, and closed and hostile environments. These hazards drive the definition of human health and performance risks associated with spaceflight. NASA’s Human System Risk Board maintains the human spaceflight risk posture for in-mission risks, as well as post-flight, Long-Term Health (LTH)risks potentially occurring later in the astronaut’s life. LTH risk encompasses the timeframe from immediately post-flight, through the rest of an astronaut’s career, through retirement, and until death. Possible LTH risk outcomes include the time and interventions needed for the astronaut to return to preflight physiological states after experiencing spaceflight hazards and recovery from any in-mission medical events that persist into the post-flight timeframe. It includes chronic complications that may arise due to experiencing in-flight medical conditions or injuries and medical conditions that occur later in life with a higher probability of occurrence or with more severity because of their spaceflight exposure. Finally, LTH risk outcomes can also include a reduction in life expectancy due to spaceflight exposures. There have been 144 medical conditions identified by NASA’s Lifetime Surveillance of Astronaut Health team to be associated with LTH risk. Epidemiological studies have been performed for some of these conditions to determine if astronauts suffer from an increased prevalence or severity of the condition due to their spaceflight experience compared to a comparable cohort .Differences in astronaut mortality or morbidity due to spaceflight experience were not detected in several of these studies. There were two cases where a modest increase in the incidence rate of astronaut LTH outcomes was detected. The first suggested an increase in the incidence of melanoma cases in astronauts, where the number of cases in astronauts were similar to the elevated number of cases observed in airplane pilots. The second provided some evidence of elevated numbers of cardiovascular disease events in astronauts compared to an appropriate healthy comparator cohort, which may warrant additional investigation. The lack of detection of LTH risk outcomes should not ease concerns about astronaut LTH. The studies highlighted here constitute only a small portion of the potential LTH conditions that could occur. Once epidemiological studies are performed on all conditions, significant findings may be detected. The analysis of astronaut LTH also suffers from limited numbers of data points because of the limited numbers of astronauts overall and the even fewer who have reached an age where LTH outcomes may begin to manifest. As shuttle and ISS astronauts begin to age and increase the feasibility of analysis, LTH outcomes may be detected. An application of risk quantification is the use of risk metrics within trade studies for resource prioritization and decision making. Trade studies regarding countermeasures to LTH risk outcomes would benefit from a quantification of LTH risk. NASA has ground-based processes in place such as astronaut screening and access to continuous medical monitoring and care during and after their astronaut career which are the main methods for mitigating LTH risk. In-mission countermeasures, such as acceptable levels of medical care and available countermeasures to counter spaceflight related physiological decrements, can mitigate a poor health and performance status immediately post-flight. Identifying appropriate risk metrics, obtaining valid quantities for them, and tying them to LTH countermeasures are necessary steps for realizing their use in trade studies. This presentation will highlight the challenges associated with the identification, quantification, and utilization of LTH risk metrics

Beth Lewandowski↗

147 Nd Quantification Using HSCCC-Purified Samples

Quantifying the fission product 147 Nd in nuclear debris samples is an important component of post-detonation nuclear forensics. The most accurate quantifications are obtained when Nd is purified from all other fission products, actinides, activation products, and environmental matrix contained within the debris. In this study, a recently developed method for Nd purification was tested, purifying 147 Nd from solutions of mixed fission products using high-speed counter-current chromatography (HSCCC). Importantly, the new method allowed for faster elution of Nd from the column as compared with established high performance liquid chromatography (HPLC) methods, and resulted in accurate/precise 147 Nd quantification by gamma-ray spectrometry. While the up-front equipment costs associated with HSCCC may be higher, its operational costs are on par with those of HPLC (solvents, extractants, power). Gas-flow proportional beta decay counting revealed contamination from the nearest neighbor lanthanide 143 Pr (a gamma-silent radioisotope) in the HSCCC-purified samples, but the activity contribution from 147 Nd could still be quantified. Remarkably consistent elution profiles were observed for the HSCCC method, spanning rare earth element (REE) loadings of more than 10 orders of magnitude (tracer to mmol quantities). In conclusion, the reliability and speed of the new method suggest utility for the rapid separation and quantification of 147 Nd in unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large Aperture Scanning Lidar Based on Holographic Optical Elements

Lidar remote sensing instruments can make a significant contribution to satisfying many of the required measurements of atmospheric and surface parameters for future spaceborne platforms, including topographic altimeters, atmospheric profiles of, wind, humidity, temperature, trace molecules, aerosols, and clouds. It is highly desirable to have wide measurement swaths for rapid coverage rather than just the narrow ribbon of data that is obtained with a nadir only observation. For most applications global coverage is required, and for wind measurements scanning or pointing is required in order to retrieve the full 3-D wind vector from multiple line-of-sight Doppler measurements. Conventional lidar receivers make up a substantial portion of the instrument's size and weight. Wide angle scanning typically requires a large scanning mirror in front of the receiver telescope, or pointing the entire telescope and aft optics assembly, Either of these methods entails the use of large bearings, motors, gearing and their associated electronics. Spaceborne instruments also need reaction wheels to counter the torque applied to the spacecraft by these motions. NASA has developed simplified conical scanning telescopes using Holographic Optical Elements (HOEs) to reduce the size, mass, angular momentum, and cost of scanning lidar systems. NASA has developed two operating lidar systems based on 40 cm diameter HOEs. The first such system, named Prototype Holographic Atmospheric Scanner for Environmental Remote Sensing (PHASERS) was a joint development between NASA Goddard Space Flight Center (GSFC) and the University of Maryland College Park. PHASERS is based on a reflection HOE for use at the doubled Nd:YAG laser wavelength of 532 nm and has recently undergone a number of design changes in a collaborative effort between GSFC and Saint Anselm College in New Hampshire. The next step was to develop IR transmission HOEs for use with the Nd:YAG fundamental in the Holographic Airborne Rotating Lidar Instrument Experiment (HARLIE). The HOE spins like a compact disk in a large ring ball bearing. In an aircraft the HOE faces down, looking out through a window at an angle of 45 degrees off-nadir. The HOE diffracts 85% of the incident 532 nm light into a 160 micron spot at a focal length of 1 meter. HARLIE is a field deployable lidar measuring aerosol, cloud, and boundary layer backscatter for atmospheric research. It has flown several times and is also used from a ground-based trailer in an upward-looking mode. The HOE generates a 45 degree conical scan pattern by rotating at speeds up to 30 rpm. Like PHASERS, the HOE in HARLIE serves both as the laser collimating lens as well as the receiver telescope primary optic. The telescope is coupled to the receiver package via fiber optic. The transmitter is a diode pumped Nd:YAG laser operating at 1064 nm, delivering 1 mJ pulses at a 5 KHz rep-rate. The receiver has a 200 microradian field-of-view and a 0.5 nm optical bandpass. The photon counting data system utilizes a single Geiger-mode silicon avalanche photodiode detector, This new technology has also presented us with new data visualization challenges as well as new measurement techniques. The backscatter data obtained from a stationary (i.e. ground-based) scanning HOE lidar is on the surface of a cone, which when viewed over many consecutive scans can reveal atmospheric motions on this surface over time as the atmosphere advects over the site. In a moving platform such as an airplane or satellite, the data from consecutive scans cover different areas under the flight path, revealing atmospheric structure in 3-dimensions. An example of a visualization of HARLIE ground-based data is presented, showing aerosol backscatter on a 90 degree conical surface generated from one 360 degree scan of the lidar during the HOLO-1 field campaign on the afternoon of 10 March 1999. Higher backscatter levels are rendered as lighter signal against a dark background. Breaking Kelvin-Helmholtz waves are evident on the north side of the scan at an altitude of 10-11 km. Time series of successive scans made at regular intervals render unique views of atmospheric motions, from which vertical profiles of atmospheric wind vectors can be obtained using a unique data analysis approach. Wind vectors obtained from the lidar were compared with co-located radiosonde wind profiles during an intensive operating period in September-October 2000 at the Atmospheric Radiation Measurement Program's Southern Great Plains Central Facility.

Schwemmer, Geary K.↗

Search for the 𝐾 𝐿 → 𝜋 0 ⁢$𝜈⁢\bar{𝜈}$ Decay at the J-PARC KOTO Experiment

We performed a search for the 𝐾 𝐿 → 𝜋 0 ⁢$𝜈⁢\bar{𝜈}$ decay using the data taken in 2021 at the J-PARC KOTO experiment. With newly installed counters and new analysis method, the expected background was suppressed to 0.252 ± 0.055 stat ⁢ $^{+0.052}_{{−0.067^{syst}}}$. With a single event sensitivity of (9.33 ± 0.0⁢6 stat ±0.8⁢4 syst ) × 10 −10 , no events were observed in the signal region. An upper limit on the branching fraction for the decay was set to be 2.2 ×10 −9 at the 90% confidence level (C.L.), which improved the previous upper limit from KOTO by a factor of 1.4. With the same data, a search for 𝐾 𝐿 → 𝜋 0 ⁢𝑋 0 was also performed, where 𝑋 0 is an invisible boson with a mass ranging from 1 to 260 MeV/𝑐 2 . For 𝑋 0 with a mass of 135 MeV/𝑐 2 , an upper limit on the branching fraction of 𝐾 𝐿 → 𝜋 0 ⁢𝑋 0 was set to be 1.6 ×10 −9 at the 90% C.L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗