Search NASA⌕ Search

SEARCH · Search NASA

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

An X-ray shadowgraph to locate transient high-energy celestial sources

A new technique has been developed to locate strong, transient X-ray sources such as the recently discovered gamma ray bursts. The instrument, termed a shadowgraph, locates sources by detecting the X-ray shadow cast by a large occulting mask pattern on an imaging detector. Angular resolutions of from 2 to 10 arc minutes are obtainable while essentially full sky coverage is maintained. The optimum energy range of operation is between 20 keV and 100 keV. The high efficiency X-ray imaging detectors, which make it possible to locate bursts with intensities down to approximately 10 photons/sq cm sec, are capable of detecting single 20 keV photons with a spatial resolution of approximately 0.2 mm. The detectors consist of an X-ray to optical conversion phosphor, a multistage image intensifier, and a CCD image readout.

Fishman, G. J.↗

A CCD image transducer and processor suitable for space flight

A satellite borne extreme ultraviolet solar telescope makes use of CCD area arrays for both image readout and onboard data processing. The instrument is designed to view the inner solar corona in the wavelength band 170 - 630 A, and the output video stream may be selected by ground command to present the coronal scene, or the time-rate-of-change of the scene. Details of the CCD application to onboard image processing are described, and a discussion of the processor's potential for telemetry bandwidth compression is included. Optical coupling methods, data storage requirements, spatial and temporal resolution, and nonsymmetry of resolution (pitch) in the CCD are discussed.

Michels, D. J.↗

Planetary investigation utilizing an imaging spectrometer system based upon charge injection technology

An intrinsic silicon charge injection device (CID) television sensor array has been used in conjunction with a CaMoO4 colinear tunable acousto optic filter, a 61 inch reflector, a sophisticated computer system, and a digital color TV scan converter/computer to produce near IR images of Saturn and Jupiter with 10A spectral resolution and approximately 3 inch spatial resolution. The CID camera has successfully obtained digitized 100 x 100 array images with 5 minutes of exposure time, and slow-scanned readout to a computer. Details of the equipment setup, innovations, problems, experience, data and final equipment performance limits are given.

Wattson, R. B.↗

Cooled slow-scan performance of a 512 by 320 element charge-coupled imager

A 512 x 320 element charge coupled imager has been fabricated and tested under cooled slow scan conditions to evaluate the device's performance under a variety of long integration and slow scan readout conditions. Operation in a low blooming mode of operation enables the sensor to be exposed with portions of the image heavily overexposed, without those areas spreading into adjacent picture areas. Device design, layout, and operating mode are described, and presents experimental results, including displayed images taken under cooled slow scan operation, are reported.

Rodgers, R. L., III↗

Slow-scan operation of long linear CCD arrays

Linear CCD arrays used singly or in optically butted assemblies permit practical implementation of long line array systems with 6000 or more picture elements per line with readout rates in excess of 5 MHz. Display and tape recording of slow scan imagery with over 1000 picture elements per line also presents unique challenges. This paper discusses performance results and the operation of 1728-element CCD arrays for generation of high resolution slow scan imagery and some approaches for recording and display of the imagery. The implication of dark current and its control are discussed.

Vicars-Harris, M.↗

Manual control displays for a four-dimensional landing approach

Six instrument rated pilots flew a STOL fixed base simulator to study the effectiveness of three displays for a four dimensional approach. The three examined displays were a digital readout of forward position error, a digital speed command, and an analog display showing forward position error and error prediction. A flight director was used in all conditions. All test runs were for a typical four dimensional approach in moderate turbulence that included a change in commanded ground speed, a change in flight path angle, and two standard rate sixty degree turns. Use of the digital forward position error display resulted in large overshoot in the forward position error. Some type of lead (rate or prediction information) was shown to be needed. The best overall performance was obtained using the speed command display. It was demonstrated that curved approaches can be flown with relative ease.

Silverthorn, J. T.↗

The Nimbus F Random Access Measurement System /RAMS/

In 1974, the Random Access Measurement System (RAMS) will be launched aboard the Nimbus F satellite as part of the Tropical Wind, Energy Conversion, and Reference Level Experiment (TWERLE). This paper describes operation and performance of the RAMS instrument, which will provide a means of tracking and collecting data from a large number of instrumented platforms. In operation, the RAMS will perform satellite onboard processing of up to eight simultaneous platform transmissions, following search and detection of the randomly received platform transmissions in a compressed-time expanded-frequency domain. The processed data is stored aboard the satellite for readout every 108 minutes (orbital period), and platform locational coordinates and/or velocity components are determined in a central ground data processing facility.

Coates, J. L.↗

Electro-optical liquid depth sensor

Transducer utilizes absorptive properties of water to determine variations in depth without disturbing liquid. Instrument is inexpensive, simple, and small and thus can be used in lieu of direct graduated scale readout or capacitive, ultrasonic, resistive or inducive sensors when these are impractical because of complexity or cost.

Heppner, D. B.↗

Interactive imaging and data processing

Image processing method is capable of contrast enhancement, noise filtering, and photometric distortion removal in near real time. System uses digital image integration and digital video recorder as image buffer. Each frame of data is entered into memory; registers provide readout of stored TV frame.

Alsberg, H.↗

Low-light-level integrating video system

System consists of television camera using 25 mm SEC vidicon, low dispersion spectrograph, and digital video image system used for buffer storage of video data during tube readout scanning. Six-bit ADC converts video to digital data which are stored on magnetic tape for future evaluation.

Duncan, B. J.↗

Quartz-crystal-oscillator hygrometer

Measuring device, which eliminates complex and expensive optical components by electronically sensing dewpoint of water vapor in gas, employs piezoelectric crystal oscillator, supportive circuitry, temperature regulators, and readout.

Kruger, R.↗

A landmark recognition and tracking experiment for flight on the Shuttle/Advanced Technology Laboratory (ATL)

The preliminary design of an experiment for landmark recognition and tracking from the Shuttle/Advanced Technology Laboratory is described. It makes use of parallel coherent optical processing to perform correlation tests between landmarks observed passively with a telescope and previously made holographic matched filters. The experimental equipment including the optics, the low power laser, the random access file of matched filters and the electro-optical readout device are described. A real time optically excited liquid crystal device is recommended for performing the input non-coherent optical to coherent optical interface function. A development program leading to a flight experiment in 1981 is outlined.

Welch, J. D.↗

Redundancy management of multiple KT-70 inertial measurement units applicable to the space shuttle

Results of an investigation of velocity failure detection and isolation for 3 inertial measuring units (IMU) and 2 inertial measuring units (IMU) configurations are presented. The failure detection and isolation algorithm performance was highly successful and most types of velocity errors were detected and isolated. The failure detection and isolation algorithm also included attitude FDI but was not evaluated because of the lack of time and low resolution in the gimbal angle synchro outputs. The shuttle KT-70 IMUs will have dual-speed resolvers and high resolution gimbal angle readouts. It was demonstrated by these tests that a single computer utilizing a serial data bus can successfully control a redundant 3-IMU system and perform FDI.

Cook, L. J.↗

Solid state television camera

The design, fabrication, and tests of a solid state television camera using a new charge-coupled imaging device are reported. An RCA charge-coupled device arranged in a 512 by 320 format and directly compatible with EIA format standards was the sensor selected. This is a three-phase, sealed surface-channel array that has 163,840 sensor elements, which employs a vertical frame transfer system for image readout. Included are test results of the complete camera system, circuit description and changes to such circuits as a result of integration and test, maintenance and operation section, recommendations to improve the camera system, and a complete set of electrical and mechanical drawing sketches.

Source record↗

Water system virus detection

A monitoring system developed to test the capability of a water recovery system to reject the passage of viruses into the recovered water is described. A nonpathogenic marker virus, bacteriophage F2, is fed into the process stream before the recovery unit and the reclaimed water is assayed for its presence. Detection of the marker virus consists of two major components, concentration and isolation of the marker virus, and detection of the marker virus. The concentration system involves adsorption of virus to cellulose acetate filters in the presence of trivalent cations and low pH with subsequent desorption of the virus using volumes of high pH buffer. The detection of the virus is performed by a passive immune agglutination test utilizing specially prepared polystyrene particles. An engineering preliminary design was performed as a parallel effort to the laboratory development of the marker virus test system. Engineering schematics and drawings of a fully functional laboratory prototype capable of zero-G operation are presented. The instrument consists of reagent pump/metering system, reagent storage containers, a filter concentrator, an incubation/detector system, and an electronic readout and control system.

Fraser, A. S.↗

Study of cryogenic propellant systems for loading the space shuttle. Part 2: Hydrogen systems

Computer simulation studies of liquid hydrogen fill and vent systems for the space shuttle are studied. The computer programs calculate maximum and minimum permissible flow rates during cooldown as limited by thermal stress considerations, fill line cooldown time, pressure drop, flow rates, vapor content, vent line pressure drop and vent line discharge temperature. The input data for these programs are selected through graphic displays which schematically depict the part of the system being analyzed. The computed output is also displayed in the form of printed messages and graphs. Digital readouts of graph coordinates may also be obtained. Procedures are given for operation of the graphic display unit and the associated minicomputer and timesharing computer.

Steward, W. G.↗

Manufacturing techniques for gyroscopes in gravity probe B

The design of the fused silica gyroscope configuration is presented. The first gyroscope was made for erection and spin tests only and does not contain the angle readout loops necessary for a functioning experimental gyroscope. The rotor ball described is not coated with the ultimate material, niobium, but instead with a sandwich of titanium, cooper, and titanium for spin-up test purposes. Background, historical information, manufacturing procedures, and sketches for this gyroscope are included to provide a better understanding of the device and the techniques and special tools required to manufacture a fused silica gyroscope to the required specifications.

Rasquin, J. R.↗

Solid state, CCD-buried channel, television camera study and design

An investigation of an all solid state television camera design, which uses a buried channel charge-coupled device (CCD) as the image sensor, was undertaken. A 380 x 488 element CCD array was utilized to ensure compatibility with 525 line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (a) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (b) techniques for the elimination or suppression of CCD blemish effects, and (c) automatic light control and video gain control techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a design which addresses the program requirements for a deliverable solid state TV camera.

Hoagland, K. A.↗