Search NASA⌕ Search

SEARCH · Search NASA

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

An online, energy-resolving beam profile detector for laser-driven proton beams

In this paper, a scintillator-based online beam profile detector for the characterization of laser-driven proton beams is presented. Using a pixelated matrix with varying absorber thicknesses, the proton beam is spatially resolved in two dimensions and simultaneously energy-resolved. A thin plastic scintillator placed behind the absorber and read out by a CCD camera is used as the active detector material. The spatial detector resolution reaches down to ∼4 mm and the detector can resolve proton beam profiles for up to 9 proton threshold energies. With these detector design parameters, the spatial characteristics of the proton distribution and its cut-off energy can be analyzed online and on-shot under vacuum conditions. The paper discusses the detector design, its characterization and calibration at a conventional proton source, as well as the first detector application at a laser-driven proton source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical simulation of a signal for a scheme of an atomic spin gyroscope with optical detection

An operation scheme of an atomic spin gyroscope with optical detection is described, in which two noble gas isotopes, {sup 129} Xe and {sup 131} Xe, are used as carriers of the spin of an atomic nucleus. Based on this scheme, we construct a theoretical model of the dynamics of the spin polarisation of an alkali metal and the magnetisation of a noble gas under conditions of spin-exchange interaction and optical pumping. This model allows one to simulate the pumping and signal readout in the gyroscope scheme. The time dependences of this signal are plotted, the analysis of which shows that the signal has a sophisticated complex structure. Thus, the problem arises of demodulating this signal based on the improvement of demodulation methods and algorithms. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE TAOS PROJECT: RESULTS FROM SEVEN YEARS OF SURVEY DATA

The Taiwanese-American Occultation Survey (TAOS) aims to detect serendipitous occultations of stars by small ({approx}1 km diameter) objects in the Kuiper Belt and beyond. Such events are very rare (<10{sup -3} events per star per year) and short in duration ({approx}200 ms), so many stars must be monitored at a high readout cadence. TAOS monitors typically {approx}500 stars simultaneously at a 5 Hz readout cadence with four telescopes located at Lulin Observatory in central Taiwan. In this paper, we report the results of the search for small Kuiper Belt objects (KBOs) in seven years of data. No occultation events were found, resulting in a 95% c.l. upper limit on the slope of the faint end of the KBO size distribution of q = 3.34-3.82, depending on the surface density at the break in the size distribution at a diameter of about 90 km.

79 ASTRONOMY AND ASTROPHYSICS↗

CHANDRA DETECTION OF EXTENDED X-RAY EMISSION FROM THE RECURRENT NOVA RS OPHIUCHI

Radio, infrared, and optical observations of the 2006 eruption of the symbiotic recurrent nova RS Ophiuchi showed that the explosion produced non-spherical ejecta. Some of this ejected material was in the form of bipolar jets to the east and west of the central source. Here we describe X-ray observations taken with the Chandra X-ray Observatory one and a half years after the beginning of the outburst that reveal narrow, extended structure with a position angle of approximately 300 deg. (east of north). Although the orientation of the extended feature in the X-ray image is consistent with the readout direction of the CCD detector, extensive testing suggests that the feature is not an artifact. Assuming it is not an instrumental effect, the extended X-ray structure shows hot plasma stretching more than 1900 AU from the central binary (taking a distance of 1.6 kpc). The X-ray emission is elongated in the northwest direction-in line with the extended infrared emission and some minor features in the published radio image. It is less consistent with the orientation of the radio jets and the main bipolar optical structure. Most of the photons in the extended X-ray structure have energies of less than 0.8 keV. If the extended X-ray feature was produced when the nova explosion occurred, then its 1.''2 length as of 2007 August implies that it expanded at an average rate of more than 2 mas day{sup -1}, which corresponds to a flow speed of greater than 6000 km s{sup -1} (days/1.6 kpc) in the plane of the sky. This expansion rate is similar to the earliest measured expansion rates for the radio jets.

79 ASTRONOMY AND ASTROPHYSICS↗

REVISITING THE SHORT-TERM X-RAY SPECTRAL VARIABILITY OF NGC 4151 WITH CHANDRA

We present new X-ray spectral data for the Seyfert 1 nucleus in NGC 4151 observed with Chandra for {approx}200 ks. A significant ACIS pileup is present, resulting in a nonlinear count rate variation during the observation. With pileup corrected spectral fitting, we are able to recover the spectral parameters and find consistency with those derived from unpiled events in the ACIS readout streak and outer region from the bright nucleus. The absorption corrected 2-10 keV flux of the nucleus varied between 6 x 10{sup -11} erg s{sup -1} cm{sup -2} and 10{sup -10} erg s{sup -1} cm{sup -2} (L{sub 2-10{sub keV}} {approx} 1.3-2.1 x 10{sup 42} erg s{sup -1}). Similar to earlier Chandra studies of NGC 4151 at a historical low state, the photon indices derived from the same absorbed power-law model are {Gamma} {approx} 0.7-0.9. However, we show that {Gamma} is highly dependent on the adopted spectral models. Fitting the power-law continuum with a Compton reflection component gives {Gamma} {approx} 1.1. By including passage of non-uniform X-ray obscuring clouds, we can reproduce the apparent flat spectral states with {Gamma} {approx} 1.7, typical for Seyfert 1 active galactic nuclei. The same model also fits the hard spectra from previous ASCA 'long look' observation of NGC 4151 in the lowest flux state. The spectral variability during our observation can be interpreted as variations in intrinsic soft continuum flux relative to a Compton reflection component that is from distant cold material and constant on short timescale, or variations of partially covering absorber in the line of sight toward the nucleus. An ionized absorber model with ionization parameter log {xi} {approx} 0.8-1.1 can also fit the low-resolution ACIS spectra. If the partial covering model is correct, adopting a black hole mass M{sub BH{approx}}4.6x10{sup 7} M{sub sun} we constrain the distance of the obscuring cloud from the central black hole to be r {approx_lt} 9 lt-day, consistent with the size of the broad emission line region of NGC 4151 from optical reverberation mapping.

79 ASTRONOMY AND ASTROPHYSICS↗

CHROMOSPHERIC EVAPORATION IN AN M1.8 FLARE OBSERVED BY THE EXTREME-ULTRAVIOLET IMAGING SPECTROMETER ON HINODE

We discuss observations of chromospheric evaporation for a complex flare that occurred on 2012 March 9 near 03:30 UT obtained from the Extreme-ultraviolet Imaging Spectrometer (EIS) on board the Hinode spacecraft. This was a multiple event with a strong energy input that reached the M1.8 class when observed by EIS. EIS was in raster mode and fortunately the slit was almost at the exact location of a significant energy input. Also, EIS obtained a full-CCD spectrum of the flare, i.e., the entire CCD was readout so that data were obtained for about the 500 lines identified in the EIS wavelength ranges. Chromospheric evaporation characterized by 150-200 km s{sup -1} upflows was observed in multiple locations in multi-million degree spectral lines of flare ions such as Fe XXII, Fe XXIII, and Fe XXIV, with simultaneous 20-60 km s{sup -1} upflows in million degree coronal lines from ions such as Fe XII-Fe XVI. The behavior of cooler, transition region ions such as O VI, Fe VIII, He II, and Fe X is more complex, but upflows were also observed in Fe VIII and Fe X lines. At a point close to strong energy input in space and time, the flare ions Fe XXII, Fe XXIII, and Fe XXIV reveal an isothermal source with a temperature close to 14 MK and no strong blueshifted components. At this location there is a strong downflow in cooler active region lines from ions such as Fe XIII and Fe XIV, on the order of 200 km s{sup -1}. We speculate that this downflow may be evidence of the downward shock produced by reconnection in the current sheet seen in MHD simulations. A sunquake also occurred near this location. Electron densities were obtained from density sensitive lines ratios from Fe XIII and Fe XIV. Atmospheric Imaging Assembly (AIA) observations from the Solar Dynamics Observatory are used with JHelioviewer to obtain a qualitative overview of the flare. However, AIA data are not presented in this paper. In summary, spectroscopic data from EIS are presented that can be used for predictive tests of models of chromospheric evaporation as envisaged in the Standard Flare Model.

79 ASTRONOMY AND ASTROPHYSICS↗

THE ARCONS PIPELINE: DATA REDUCTION FOR MKID ARRAYS

The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and energy of each photon are recorded in a manner similar to X-ray calorimetry, but at higher photon fluxes. The technique works over a very large wavelength range, is free from fundamental read noise and dark-current limitations, and provides microsecond-level timing resolution. Since the instrument reads out all pixels continuously while exposing, there is no loss of active exposure time to readout. The technology requires a different approach to data reduction compared to conventional CCDs. Here we outline here the prototype data reduction pipeline developed for ARCONS, though many of the principles are also more broadly applicable to energy-resolved photon counting arrays (e.g., transition edge sensors, superconducting tunnel junctions). We describe the pipeline's current status, and the algorithms and techniques employed in taking data from the arrival of photons at the MKID array to the production of images, spectra, and time-resolved light curves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micromegas readouts for double beta decay searches

Double beta (ββ) decay experiments are one of the most active research topics in Neutrino Physics. The measurement of the neutrinoless mode 0νββ could give unique information on the neutrino mass scale and nature. The current generation of experiments aims at detector target masses at the 100 kg scale, while the next generation will need to go to the ton scale in order to completely explore the inverse hierarchy models of neutrino mass. Very good energy resolutions and ultra-low background levels are the two main experimental requirements for a successful experiment. The topological information of the ββ events offered by gaseous detectors like gas Time Projection Chambers (TPC) could provide a very powerful tool of signal identification and background rejection. However only recent advances in TPC readouts may assure the competitiveness of a high pressure gas TPCs for ββ searches, especially regarding the required energy resolution. In this paper we present first results on energy resolution with state-of-the-art microbulk Micromesh Gas Amplification Structure (Micromegas) using a 5.5 MeV alpha source in high pressure pure xenon. Resolutions down to 2 % FWHM have been achieved for pressures up to 5 bar. These results, together with their recently measured radiopurity, prove that Micromegas readouts are not only a viable option but a very competitive one for ββ searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OVERVIEW OF THE KEPLER SCIENCE PROCESSING PIPELINE

The Kepler Mission Science Operations Center (SOC) performs several critical functions including managing the {approx}156,000 target stars, associated target tables, science data compression tables and parameters, as well as processing the raw photometric data downlinked from the spacecraft each month. The raw data are first calibrated at the pixel level to correct for bias, smear induced by a shutterless readout, and other detector and electronic effects. A background sky flux is estimated from {approx}4500 pixels on each of the 84 CCD readout channels, and simple aperture photometry is performed on an optimal aperture for each star. Ancillary engineering data and diagnostic information extracted from the science data are used to remove systematic errors in the flux time series that are correlated with these data prior to searching for signatures of transiting planets with a wavelet-based, adaptive matched filter. Stars with signatures exceeding 7.1{sigma} are subjected to a suite of statistical tests including an examination of each star's centroid motion to reject false positives caused by background eclipsing binaries. Physical parameters for each planetary candidate are fitted to the transit signature, and signatures of additional transiting planets are sought in the residual light curve. The pipeline is operational, finding planetary signatures and providing robust eliminations of false positives.

79 ASTRONOMY AND ASTROPHYSICS↗

DISCOVERY OF FINELY STRUCTURED DYNAMIC SOLAR CORONA OBSERVED IN THE Hi-C TELESCOPE

In the Summer of 2012, the High-resolution Coronal Imager (Hi-C) flew on board a NASA sounding rocket and collected the highest spatial resolution images ever obtained of the solar corona. One of the goals of the Hi-C flight was to characterize the substructure of the solar corona. We therefore examine how the intensity scales from AIA resolution to Hi-C resolution. For each low-resolution pixel, we calculate the standard deviation in the contributing high-resolution pixel intensities and compare that to the expected standard deviation calculated from the noise. If these numbers are approximately equal, the corona can be assumed to be smoothly varying, i.e., have no evidence of substructure in the Hi-C image to within Hi-C's ability to measure it given its throughput and readout noise. A standard deviation much larger than the noise value indicates the presence of substructure. We calculate these values for each low-resolution pixel for each frame of the Hi-C data. On average, 70% of the pixels in each Hi-C image show no evidence of substructure. The locations where substructure is prevalent is in the moss regions and in regions of sheared magnetic field. We also find that the level of substructure varies significantly over the roughly 160 s of the Hi-C data analyzed here. This result indicates that the finely structured corona is concentrated in regions of heating and is highly time dependent.

79 ASTRONOMY AND ASTROPHYSICS↗

Multimode quantum memory based on atomic frequency combs

An efficient multimode quantum memory is a crucial resource for long-distance quantum communication based on quantum repeaters. We propose a quantum memory based on spectral shaping of an inhomogeneously broadened optical transition into an atomic frequency comb (AFC). The spectral width of the AFC allows efficient storage of multiple temporal modes without the need to increase the absorption depth of the storage material, in contrast to previously known quantum memories. Efficient readout is possible thanks to rephasing of the atomic dipoles due to the AFC structure. Long-time storage and on-demand readout is achieved by use of spin states in a lambda-type configuration. We show that an AFC quantum memory realized in solids doped with rare-earth-metal ions could store hundreds of modes or more with close to unit efficiency, for material parameters achievable today.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing macroscopic quantum states with a sub-Heisenberg accuracy

Significant achievements in high-sensitivity measurements will soon allow us to probe quantum behaviors of macroscopic mechanical oscillators. In a recent work [Phys. Rev. A 80, 043802 (2009)], we formulated a general framework for treating preparation of Gaussian quantum states of macroscopic oscillators through linear position measurements. To outline a complete procedure for testing macroscopic quantum mechanics, here we consider a subsequent verification stage which probes the prepared macroscopic quantum state and verifies the quantum dynamics. By adopting an optimal time-dependent homodyne detection in which the phase of the local oscillator varies in time, the conditional quantum state can be characterized below the Heisenberg limit, thereby achieving a quantum tomography. In the limiting case of no readout loss, such a scheme evades measurement-induced back action, which is identical to the variational-type measurement scheme invented by Vyatchanin et al. [JETP 77, 218 (1993)] but in the context for detecting gravitational waves. To motivate macroscopic quantum mechanics experiments with future gravitational-wave detectors, we mostly focus on the parameter regime where the characteristic measurement frequency is much higher than the oscillator frequency and the classical noises are Markovian, which captures the main feature of a broadband gravitational-wave detector. In addition, we discuss verifications of Einstein-Podolsky-Rosen-type entanglement between macroscopic test masses in future gravitational-wave detectors, which enables us to test one particular version of gravity decoherence conjectured by Diosi [Phys. Lett. A120, 377 (1987)] and Penrose [Gen. Rel. Grav. 28, 581 (1996)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum volume hologram

We propose a scheme for parallel spatially multimode quantum memory for light. The scheme is based on a counterpropagating quantum signal wave and a strong classical reference wave as in a classical volume hologram and therefore can be called a quantum volume hologram. The medium for the hologram consists of a spatially extended ensemble of atoms placed in a magnetic field. The write-in and readout of this quantum hologram is as simple as that of its classical counterpart and consists of a single-pass illumination. In addition, we show that the present scheme for a quantum hologram is less sensitive to diffraction and therefore is capable of achieving a higher density of storage of spatial modes as compared to previous proposals. We present a feasibility study and show that experimental implementation is possible with available cold atomic samples. A quantum hologram capable of storing entangled images can become an important ingredient in quantum information processing and quantum imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Entangling the lattice clock: Towards Heisenberg-limited timekeeping

A scheme is presented for entangling the atoms of an optical lattice to reduce the quantum projection noise of a clock measurement. The divalent clock atoms are held in a lattice at a 'magic' wavelength that does not perturb the clock frequency - to maintain clock accuracy - while an open-shell J=1/2 'head' atom is coherently transported between lattice sites via the lattice polarization. This polarization-dependent 'Archimedes' screw' transport at magic wavelength takes advantage of the vanishing vector polarizability of the scalar, J=0, clock states of bosonic isotopes of divalent atoms. The on-site interactions between the clock atoms and the head atom are used to engineer entanglement and for clock readout.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum-information-processing architecture with endohedral fullerenes in a carbon nanotube

A potential quantum-information processor is proposed using an array of the endohedral fullerenes {sup 15}N-C{sub 60} or {sup 31}P-C{sub 60} contained in a single walled carbon nanotube (SWCNT). The qubits are encoded in the nuclear spins of the doped atoms, while the electronic spins are used for initialization and readout, as well as for two-qubit operations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tunable joint measurements in the dispersive regime of cavity QED

Joint measurements of multiple qubits open new possibilities for quantum information processing. Here we present an approach based on homodyne detection to realize such measurements in the dispersive regime of cavity or circuit QED. By changing details of the measurement, the readout can be tuned from extracting only single-qubit to extracting only multiqubit properties. We obtain a reduced stochastic master equation describing this measurement and its effect on the qubits. As an example, we present results showing parity measurements of two qubits. In this situation, measurement of an initially unentangled state can yield, with near unit probability, a state of significant concurrence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scalable simultaneous multiqubit readout with 99.99% single-shot fidelity

We describe single-shot readout of a trapped-ion multiqubit register using space- and time-resolved camera detection. For a single qubit we measure 0.9(3)x10{sup -4} readout error in 400 {mu}s exposure time, limited by the qubit's decay lifetime. For a four-qubit register (a 'qunybble'), we measure an additional error of only 0.1(1)x10{sup -4} per qubit, despite the presence of 4% optical cross-talk between neighboring qubits. A study of the cross-talk indicates that the method would scale with a negligible loss of fidelity to {approx}10 000 qubits at a density of < or approx. 1 qubit/{mu}m{sup 2}, with a readout time of {approx}1 {mu}s/qubit.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hyperfine and optical barium ion qubits

State preparation, qubit rotation, and high fidelity readout are demonstrated for two different {sup 137}Ba{sup +} qubit types. First, an optical qubit on the narrow 6S{sub 1/2} to 5D{sub 5/2} transition at 1.76 {mu}m is implemented. Then, leveraging the techniques developed there for readout, a ground-state hyperfine qubit using the magnetically insensitive transition at 8 GHz is accomplished.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗