Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Development and Evaluation of Occupancy-Aware HVAC Control for Residential Building Energy Efficiency and Occupant Comfort

Occupancy-aware heating, ventilation, and air conditioning (HVAC) control offers the opportunity to reduce energy use without sacrificing thermal comfort. Residential HVAC systems often use manually-adjusted or constant setpoint temperatures, which heat and cool the house regardless of whether it is needed. By incorporating occupancy-awareness into HVAC control, heating and cooling can be used for only those time periods it is needed. Yet, bringing this technology to fruition is dependent on accurately predicting occupancy. Non-probabilistic prediction models offer an opportunity to use collected occupancy data to predict future occupancy profiles. Smart devices, such as a connected thermostat, which already include occupancy sensors, can be used to provide a continually growing collection of data that can then be harnessed for short-term occupancy prediction by compiling and creating a binary occupancy prediction. Real occupancy data from six homes located in Colorado is analyzed and investigated using this occupancy prediction model. Results show that non-probabilistic occupancy models in combination with occupancy sensors can be combined to provide a hybrid HVAC control with savings on average of 5.0% and without degradation of thermal comfort. Model predictive control provides further opportunities, with the ability to adjust the relative importance between thermal comfort and energy savings to achieve savings between 1% and 13.3% depending on the relative weighting between thermal comfort and energy savings. In all cases, occupancy prediction allows the opportunity for a more intelligent and optimized strategy to residential HVAC control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Uncontrolled Electric Vehicle Charging Impacts on Distribution Electric Power Systems with Primarily Residential, Commercial or Industrial Loads

An increase in Electric Vehicles (EV) will result in higher demands on the distribution electric power systems (EPS) which may result in thermal line overloading and low voltage violations. To understand the impact, this work simulates two EV charging scenarios (home- and work-dominant) under potential 2030 EV adoption levels on 10 actual distribution feeders that support residential, commercial, and industrial loads. The simulations include actual driving patterns of existing (non-EV) vehicles taken from global positioning system (GPS) data. The GPS driving behaviors, which explain the spatial and temporal EV charging demands, provide information on each vehicles travel distance, dwell locations, and dwell durations. Then, the EPS simulations incorporate the EV charging demands to calculate the power flow across the feeder. Simulation results show that voltage impacts are modest (less than 0.01 p.u.), likely due to robust feeder designs and the models only represent the high-voltage (“primary”) system components. Line loading impacts are more noticeable, with a maximum increase of about 15%. Additionally, the feeder peak load times experience a slight shift for residential and mixed feeders (≈1 h), not at all for the industrial, and 8 h for the commercial feeder.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transport improvement, commuting costs, and residential location

A theoretical framework for evaluating the effects of introducing new transportation on residential travel patterns is presented. Data are based on changes in residential location of urban commuters that alter the mode and length of work trips as well as economic factors.

Stucker, J. P.↗

Preliminary design package for residential heating/cooling system: Rankine air conditioner redesign

A summary of the preliminary redesign and development of a marketable single family heating and cooling system is presented. The interim design and schedule status of the residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities were discussed. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.

Source record↗

Integrated residential photovoltaic array development

An optimum integrated residential photovoltaic array/module is addressed. Nineteen existing or proposed systems intended for residential applications are described. Each of these systems is rated against a comprehensive set of evaluation criteria in an effort to formulate three module design concepts for further study and analysis. This evaluation led to a number of observations which are enumerated and should be considered in future module and array designs. Three module concepts are presented as baseline design approaches to be further analyzed and optimized. These options include: (1) a rectangular, direct mounted, shingle type module; (2) an integrally mounted module with nonconductive exposed elements; and (3) an aluminum framed, stand off module. Preliminary design drawings are presented for each of these module configurations.

Shepard, N. F., Jr.↗

Survey of residential and intermediate photovoltaic applications

The construction and operation of residential and intermediate size photovoltaic power systems as performed by the DOE Photovoltaics Program are reviewed. The program is directed toward the development of economically competitive, commercially available, photovoltaic power systems to provide safe and reliable energy for a wide range of applications. Systems which are currently operational or in construction range in size from 5 kWp to 225 kWp, and real-world testing is being pursued with residential, industrial, institutional, and commercial systems to establish their feasibility and readiness for commercialization.

Hesse, J. L.↗

A Methology for Assessing the Regional Transportation Energy Demands of Different Spatial Residential Development Scenarios: a Case Study for the Upper Housatonic River Basin, Massachusetts

A method is suggested whereby regional landscape planning efforts can be aided by the use of a geographic information system to determine sites for more energy efficient residential and mixed use developments within a study area. The location of land parcels suited for residential and mixed land use developments in the Upper Housatonic River Basin Study Area in Berkshire County, Massachusetts is described as well as the three development options. Significant steps in the procedure are discussed and the computation of the transportation energy requirement is elaborated.

Oski, J. A.↗

Market opportunities in Canada for multimedia residential services in rural and small urban areas

This paper reviews the studies which were undertaken jointly by Telesat and Industry Canada to provide an estimate of the market opportunities for residential multi-media services in the rural and small urban areas of Canada. This study is part of the Advanced Satcom program, a Ka-band satellite system proposal which is currently in the implementation proposal phase by the government and the Canadian space industry of which Telesat is an active member. Advanced Satcom extends the reach of terrestrial information highways to the remote and sparsely populated parts of the country in a cost-effective manner and thus provides a ubiquitous coverage of the information highways to all Canadians. Therefore, the rural and small urban markets are believed to be good opportunities for the Advanced Satcom. Although the results are primarily intended for fixed residential applications, they can also be used as input to market opportunity studies for wideband mobile applications.

Shariatmadar, Mehran↗

Measured Rattle Threshold of Residential House Windows

Window rattle is a common indoor noise effect in houses exposed to low frequency noise from such sources as railroads, blast noise and sonic boom. Human perception of rattle can be negative that is a motivating factor of the current research effort to study sonic boom induced window rattle. A rattle study has been conducted on residential houses containing windows of different construction at a variety of geographic locations within the United States. Windows in these houses were excited by a portable, high-powered loudspeaker and enclosure specifically designed to be mounted on the house exterior to cover an entire window. Window vibration was measured with accelerometers placed on different window components. Reference microphones were also placed inside the house and inside of the loudspeaker box. Swept sine excitation was used to identify the vibration threshold at which the response of the structure becomes non-linear and begins to rattle. Initial results from this study are presented and discussed. Future efforts will continue to explore the rattle occurrence in windows of residential houses exposed to sonic booms.

Sizov, Natalia↗

Phoenix Climate: Employing NASA Earth Observations to Conduct Site Suitability Analyses on Residential Tree Planting Initiatives in Phoenix, AZ

Phoenix, Arizona is the hottest city in the United States, with daytime summer temperatures consistently reaching upwards of 100°F. As these daytime temperatures continue to climb, heat-related illnesses and morbidity also increase. The City of Phoenix hopes to secure funding to implement the American Rescue Plan Act (ARPA) residential tree equity accelerator program. This funding will be used for targeted investments in underserved neighborhoods to increase tree canopy cover, engaging 5,000 households across selected neighborhoods. By partnering with the City of Phoenix, the Arizona Office of Heat Mitigation, and Arizona State University’s Urban Climate Research Center, our team identified residential neighborhoods, block groups within qualified census tracts, and parcels to be prioritized in the ARPA program. We conducted an analysis using NASA Earth observations, movement and heat exposure data, sociodemographic data, and tree canopy data. For Earth observations, we acquired daytime land surface temperature from the Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) and land cover classification from the United States Geological Survey (USGS) National Land Cover Database (NLCD). The project will support the prioritization of city resources and tree plantings based on community vulnerability, as well as help initiate public engagement efforts and literacy with an interactive dashboard and GIS layers that contribute to the city’s property information portal.

Alison Bautista↗

Employing NASA Earth Observations and Socioeconomic Data to Conduct Site Suitability Analyses on Residential Tree Planting Initiatives in Phoenix, Arizona

Phoenix, Arizona is the hottest large city in the United States with an average summer daytime temperature of 106°F. Temperatures in Phoenix continue to climb due to increasing global greenhouse gas concentrations and regional urbanization. The impacts of high temperatures, including heat-related illnesses and deaths, are disproportionately concentrated in low-income neighborhoods often characterized by little tree canopy, lack of green space, and insufficient access to shade. The City of Phoenix’s Office of Heat Response and Mitigation and Arizona State University’s Urban Climate Research Center, partnered with NASA DEVELOP to identify residential neighborhoods and parcels within qualified census tracts (QCTs) to be prioritized for tree planting initiatives using funding from the American Rescue Plan Act (ARPA). This project conducted analyses using NASA Earth observations, socioeconomic data from the 2019 American Community Survey, and local tree canopy and mobility data. For Earth observations, daytime land surface temperature, vegetation, and land cover were obtained from the Landsat 8 Thermal Infrared Sensor (TIRS) and Operational Land Imager (OLI). The project team incorporated these data into a heat vulnerability index (HVI) with an emphasis on tree canopy and social vulnerability to rank block groups within QCTs and focused on the resulting top 25 block group HVI scores. These top 25 most vulnerable block groups were then processed through a parcel analysis to determine the feasibility of residential tree planting based on building footprints on each parcel. Within the top 25 block groups, 2,411 parcels were analyzed, and 3,133 existing trees were identified averaging 1.3 trees per parcel with 90% of parcels having 3 trees or less. Homes with 2 trees or fewer were considered high priority for future planting efforts. Based on the City’s goals for increased tree canopy the project team determined that <10,000 additional trees would need to be planted within the most vulnerable 25 block groups. The project findings have helped initiate community engagement efforts and have contributed to the approval of tree planting funds in Phoenix.

Ryan Hammock↗

The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

Net metering has become a widespread mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), but has faced challenges as PV installations grow to a larger share of generation in a number of states. This paper examines the value of the bill savings that customers receive under net metering, and the associated role of retail rate design, based on a sample of approximately two hundred residential customers of California's two largest electric utilities. We find that the bill savings per kWh of PV electricity generated varies by more than a factor of four across the customers in the sample, which is largely attributable to the inclining block structure of the utilities' residential retail rates. We also compare the bill savings under net metering to that received under three potential alternative compensation mechanisms, based on California's Market Price Referent (MPR). We find that net metering provides significantly greater bill savings than a full MPR-based feed-in tariff, but only modestly greater savings than alternative mechanisms under which hourly or monthly net excess generation is compensated at the MPR rate.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Residential Segregation,Spatial Mismatch and Economic Growth across US Metropolitan Area

Numerous studies have demonstrated the detrimental influence of residential segregation on poor inner-city residents. This study examines the impact of residential segregation on the welfare of populations in US metropolitan areas using economic growth as the indicator. Panel data of US metropolitan areas spanning 25 years, 1980 2005, are used to analyze the effect of segregation on economic growth. The results show that both racial and skill segregation have a negative impact on short and long-term economic growth, which have increased over time. Further, the negative impact of the variables associated with spatial mismatch is also revealed. The results clearly point to the need for mobility policies that favor non-White households and comprehensive strategies that promote economic opportunities in low-resource communities in the US.

economics↗

Impact of Charge Degradation on the Life Cycle Climate Performance of a Residential Air-Conditioning System

Vapor compression systems continuously leak a small fraction of their refrigerant charge to the environment, whether during operation or servicing. As a result of the slow leak rate occurring during operation, the refrigerant charge decreases until the system is serviced and recharged. This charge degradation, after a certain limit, begins to have a detrimental effect on system capacity, energy consumption, and coefficient of performance (COP). This paper presents a literature review and a summary of previous experimental work on the effect of undercharging or charge degradation of different vapor compression systems, especially those without a receiver. These systems include residential air conditioning and heat pump systems utilizing different components and refrigerants, and water chiller systems. Most of these studies show similar trends for the effect of charge degradation on system performance. However, it is found that although much experimental work exists on the effect of charge degradation on system performance, no correlation or comparison between charge degradation and system performance yet exists. Thus, based on the literature review, three different correlations that characterize the effect of charge on system capacity and energy consumption are developed for different systems as follows: one for air-conditioning systems, one for vapor compression water-to-water chiller systems, and one for heat pumps. These correlations can be implemented in vapor compression cycle simulation tools to obtain a better prediction of the system performance throughout its lifetime. In this paper, these correlations are implemented in an open source tool for life cycle climate performance (LCCP) based design of vapor compression systems. The LCCP of a residential air-source heat pump is evaluated using the tool and the effect of charge degradation on the results is studied. The heat pump is simulated using a validated component-based vapor compression system model and the LCCP results obtained using the three charge degradation correlations are compared.

Air Conditioning↗

Laboratory Performance Evaluation of Residential Scale Gas Engine Driven Heat Pump

Building space cooling is, and until 2040 is expected to continue to be, the single largest use of electricity in the residential sector in the United States (EIA Energy Outlook 2015 .) Increases in electric-grid peak demand leads to higher electricity prices, system inefficiencies, power quality problems, and even failures. Thermally-activated systems, such as gas engine-driven heat pump (GHP), can reduce peak demand. This study describes the performance of a residential scale GHP. It was developed as part of a cooperative research and development agreement (CRADA) that was authorized by the Department of Energy (DOE) between OAK Ridge National Laboratory (ORNL) and Southwest Gas. Results showed the GHP produced 16.5 kW (4.7 RT) of cooling capacity at 35 C (95 F) rating condition with gas coefficient of performance (COP) of 0.99. In heating, the GHP produced 20.2 kW (5.75 RT) with a gas COP of 1.33. The study also discusses other benefits and challenges facing the GHP technology such as cost, reliability, and noise.

Abu-Heiba, Ahmad↗

Experimental Evaluation of a Residential Refrigerator with a Novel Rotating Heat Exchanger as an Evaporator

Residential refrigerator designs have improved significantly over the recent years to achieve the required federal minimum energy standard and match with consumer expectations. Designers have been able to use innovative design features and components; however, evaporator designs have lagged in performance improvement due to the need to properly manage frost and maximize the freezer interior volume. Rotating Heat Exchangers (RHX) provide an innovative solution that addresses both of these concerns. The rotation of the fins results in continuous disruption to the boundary layer, hence reducing the overall thermal resistance. Thus, for the same capacity, the heat transfer area can be greatly reduced. Furthermore, the rotation inhibits frost growth on the fins and reduces the time and frequency of defrosting. In this paper, we present an experimental evaluation of the RHX in a benchtop refrigerant loop system showing results for different operating configurations. Cooling capacity, cooling COP, and overall energy consumption are investigated. High-speed imaging is also used to capture frost growth patterns over time on the RHX fins in the presence and absence of rotation. The results show that the rotating heat exchanger evaporator is capable of meeting the 100 W capacity requirement of residential refrigerators, while offering the potential of significant reduction in defrost energy consumption.

Evaporator↗

An Assessment of Impacts on Electric End-Use Load Profile of a Typical Residential Building from a Ground Source Heat Pump Systems Integrated with Underground Thermal Energy Storage

Buildings are the primary users of electricity, and a considerable amount of electric energy consumed in residential and commercial buildings is for meeting thermal demands (e.g., space heating/cooling, water heating, etc.). Therefore, integrating thermal energy storage with a building’s energy system has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable power supply and the thermal demands of buildings. A novel ground-source heat pump system (GSHP) integrated with underground thermal energy storage (UTES) has been developed to enable flexible electric demand at buildings while meeting their thermal demands with an energy-efficient GSHP system. This paper assessed the potential impacts of the proposed system on the peak electrical demand and annual electricity consumption in a typical residential building at various climate zones in the United States. The results show that by replacing the conventional HVAC system (air conditioner and natural gas furnace) with the UTES integrated GSHP system, summer peak electric demand can be reduced by 27% to 50% depending on the weather. Although the winter peak electrical demand could be increased by up to 70% if the proposed system replaces natural gas furnace, the existing electricity supply system for single-family homes in most regions of the United States have adequate capacity for the replacement. While eliminating the natural gas consumption for space heating, the proposed system consumes more electricity on an annual basis in heating-dominated regions. However, it consumes less electricity in cooling dominated regions. The resulting variance in annual electricity consumption in various climate zones is within 15% compared with the baseline system.

Shi, Liang↗