Search NASA⌕ Search

SEARCH · Search NASA

Results for “Randomization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Low or High Fractionation Dose {beta}-Radiotherapy for Pterygium? A Randomized Clinical Trial

Purpose: Postoperative adjuvant treatment using {beta}-radiotherapy (RT) is a proven technique for reducing the recurrence of pterygium. A randomized trial was conducted to determine whether a low fractionation dose of 2 Gy within 10 fractions would provide local control similar to that after a high fractionation dose of 5 Gy within 7 fractions for surgically resected pterygium. Methods: A randomized trial was conducted in 200 patients (216 pterygia) between February 2006 and July 2007. Only patients with fresh pterygium resected using a bare sclera method and given RT within 3 days were included. Postoperative RT was delivered using a strontium-90 eye applicator. The pterygia were randomly treated using either 5 Gy within 7 fractions (Group 1) or 2 Gy within 10 fractions (Group 2). The local control rate was calculated from the date of surgery. Results: Of the 216 pterygia included, 112 were allocated to Group 1 and 104 to Group 2. The 3-year local control rate for Groups 1 and 2 was 93.8% and 92.3%, respectively (p = .616). A statistically significant difference for cosmetic effect (p = .034), photophobia (p = .02), irritation (p = .001), and scleromalacia (p = .017) was noted in favor of Group 2. Conclusions: No better local control rate for postoperative pterygium was obtained using high-dose fractionation vs. low-dose fractionation. However, a low-dose fractionation schedule produced better cosmetic effects and resulted in fewer symptoms than high-dose fractionation. Moreover, pterygia can be safely treated in terms of local recurrence using RT schedules with a biologic effective dose of 24-52.5 Gy{sub 10.}.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Therapy Oncology Group 0247: A Randomized Phase II Study of Neoadjuvant Capecitabine and Irinotecan or Capecitabine and Oxaliplatin With Concurrent Radiotherapy for Patients With Locally Advanced Rectal Cancer

Purpose: To evaluate the rate of pathologic complete response (pCR) and the toxicity of two neoadjuvant chemoradiotherapy (chemoRT) regimens for Stage T3-T4 rectal cancer in a randomized Phase II study. Methods and Materials: Patients with Stage T3 or T4 rectal cancer of <12 cm from the anal verge were randomized to preoperative RT (50.4 Gy in 1.8-Gy fractions) with concurrent capecitabine (1,200 mg/m{sup 2}/d Mondays through Friday) and irinotecan (50 mg/m{sup 2} weekly in four doses) (Arm 1) or concurrent capecitabine (1,650 mg/m{sup 2}/d Monday through Friday) and oxaliplatin (50 mg/m{sup 2} weekly in five doses) (Arm 2). Surgery was performed 4-8 weeks after chemoRT, and adjuvant chemotherapy 4-6 weeks after surgery. The primary endpoint was the pCR rate, requiring 48 evaluable patients per arm. Results: A total of 146 patients were enrolled. The protocol chemotherapy was modified because of excessive gastrointestinal toxicity after treatment of 35 patients; 96 were assessed for the primary endpoint-the final regimen described above. The patient characteristics were similar for both arms. After chemoRT, the rate of tumor downstaging was 52% and 60% and the rate of nodal downstaging (excluding N0 patients) was 46% and 40%, for Arms 1 and 2, respectively. The pCR rate for Arm 1 was 10% and for Arm 2 was 21%. For Arm 1 and 2, the preoperative chemoRT rate of Grade 3-4 hematologic toxicity was 9% and 4% and the rate of Grade 3-4 nonhematologic toxicity was 26% and 27%, respectively. Conclusions: Preoperative chemoRT with capecitabine plus oxaliplatin for distal rectal cancer has significant clinical activity (10 of 48 pCRs) and acceptable toxicity. This regimen is currently being evaluated in a Phase III randomized trial (National Surgical Adjuvant Breast and Bowel Project R04).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SPECT Analysis of Cardiac Perfusion Changes After Whole-Breast/Chest Wall Radiation Therapy With or Without Active Breathing Coordinator: Results of a Randomized Phase 3 Trial

Purpose: Cardiac muscle perfusion, as determined by single-photon emission computed tomography (SPECT), decreases after breast and/or chest wall (BCW) irradiation. The active breathing coordinator (ABC) enables radiation delivery when the BCW is farther from the heart, thereby decreasing cardiac exposure. We hypothesized that ABC would prevent radiation-induced cardiac toxicity and conducted a randomized controlled trial evaluating myocardial perfusion changes after radiation for left-sided breast cancer with or without ABC. Methods and Materials: Stages I to III left breast cancer patients requiring adjuvant radiation therapy (XRT) were randomized to ABC or No-ABC. Myocardial perfusion was evaluated by SPECT scans (before and 6 months after BCW radiation) using 2 methods: (1) fully automated quantitative polar mapping; and (2) semiquantitative visual assessment. The left ventricle was divided into 20 segments for the polar map and 17 segments for the visual method. Segments were grouped by anatomical rings (apical, mid, basal) or by coronary artery distribution. For the visual method, 2 nuclear medicine physicians, blinded to treatment groups, scored each segment's perfusion. Scores were analyzed with nonparametric tests and linear regression. Results: Between 2006 and 2010, 57 patients were enrolled and 43 were available for analysis. The cohorts were well matched. The apical and left anterior descending coronary artery segments had significant decreases in perfusion on SPECT scans in both ABC and No-ABC cohorts. In unadjusted and adjusted analyses, controlling for pretreatment perfusion score, age, and chemotherapy, ABC was not significantly associated with prevention of perfusion deficits. Conclusions: In this randomized controlled trial, ABC does not appear to prevent radiation-induced cardiac perfusion deficits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Voice Quality After Treatment of Early Vocal Cord Cancer: A Randomized Trial Comparing Laser Surgery With Radiation Therapy

Objective: Early laryngeal cancer is usually treated with either transoral laser surgery or radiation therapy. The quality of voice achieved with these treatments has not been compared in a randomized trial. Methods and Materials: Male patients with carcinoma limited to 1 mobile vocal cord (T1aN0M0) were randomly assigned to receive either laser surgery (n=32) or external beam radiation therapy (n=28). Surgery consisted of tumor excision with a CO{sub 2} laser with the patient under general anaesthesia. External beam radiation therapy to the larynx was delivered to a cumulative dose of 66 Gy in 2-Gy daily fractions over 6.5 weeks. Voice quality was assessed at baseline and 6 and 24 months after treatment. The main outcome measures were expert-rated voice quality on a grade, roughness, breathiness, asthenia, and strain (GRBAS) scale, videolaryngostroboscopic findings, and the patients' self-rated voice quality and its impact on activities of daily living. Results: Overall voice quality between the groups was rated similar, but voice was more breathy and the glottal gap was wider in patients treated with laser surgery than in those who received radiation therapy. Patients treated with radiation therapy reported less hoarseness-related inconvenience in daily living 2 years after treatment. Three patients in each group had local cancer recurrence within 2 years from randomization. Conclusions: Radiation therapy may be the treatment of choice for patients whose requirements for voice quality are demanding. Overall voice quality was similar in both treatment groups, however, indicating a need for careful consideration of patient-related factors in the choice of a treatment option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the Effects of Aluminum-Containing and Non-Aluminum Containing Deodorants on Axillary Skin Toxicity During Radiation Therapy for Breast Cancer: A 3-Armed Randomized Controlled Trial

Purpose: Deodorant use during radiation therapy for breast cancer has been controversial as there are concerns deodorant use may exacerbate axillary skin toxicity. The present study prospectively determined the use of both aluminum-containing and non aluminum containing deodorants on axillary skin toxicity during conventionally fractionated postoperative radiation therapy for breast cancer. Methods and Materials: This 3-arm randomized controlled study was conducted at a single center, tertiary cancer hospital between March 2011 and April 2013. Participants were randomized to 1 of 2 experimental groups (aluminum-containing deodorant and soap or non–aluminum containing deodorant and soap) or a control group (soap). A total of 333 participants were randomized. Generalized estimating equations were used to estimate and compare the odds of experiencing high levels of sweating and skin toxicity in each of the deodorant groups to the odds in the control group. The study evaluated a range of endpoints including objective measurements of axilla sweating, skin toxicity, pain, itch and burning. Quality of life was assessed with a validated questionnaire. Results: Radiation characteristics were similar across all groups. Patients in the deodorant groups did not report significantly different ratings for axillary pain, itch, or burning compared with the control group. Patients in the aluminum-containing deodorant group experienced significantly less sweating than the control; the odds of their sweating being barely tolerable and frequently or always interfering with their daily activities was decreased by 85% (odds ratio, 0.15; 95% confidence interval, 0.03-0.91). Conclusions: We found no evidence that the use of either aluminum-containing or non–aluminum containing deodorant adversely effects axillary skin reaction during conventionally fractionated radiation therapy for breast cancer. Our analysis also suggests patients in the aluminum-containing deodorant arm had significantly less sweating without increased symptoms of axillary radiation skin toxicity. These results add to the evidence that the prescription of deodorants during radiation therapy for breast cancer is now questionable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-term Results of the UCSF-LBNL Randomized Trial: Charged Particle With Helium Ion Versus Iodine-125 Plaque Therapy for Choroidal and Ciliary Body Melanoma

Purpose: Relevant clinical data are needed given the increasing national interest in charged particle radiation therapy (CPT) programs. Here we report long-term outcomes from the only randomized, stratified trial comparing CPT with iodine-125 plaque therapy for choroidal and ciliary body melanoma. Methods and Materials: From 1985 to 1991, 184 patients met eligibility criteria and were randomized to receive particle (86 patients) or plaque therapy (98 patients). Patients were stratified by tumor diameter, thickness, distance to disc/fovea, anterior extension, and visual acuity. Tumors close to the optic disc were included. Local tumor control, as well as eye preservation, metastases due to melanoma, and survival were evaluated. Results: Median follow-up times for particle and plaque arm patients were 14.6 years and 12.3 years, respectively (P=.22), and for those alive at last follow-up, 18.5 and 16.5 years, respectively (P=.81). Local control (LC) for particle versus plaque treatment was 100% versus 84% at 5 years, and 98% versus 79% at 12 years, respectively (log rank: P=.0006). If patients with tumors close to the disc (<2 mm) were excluded, CPT still resulted in significantly improved LC: 100% versus 90% at 5 years and 98% versus 86% at 12 years, respectively (log rank: P=.048). Enucleation rate was lower after CPT: 11% versus 22% at 5 years and 17% versus 37% at 12 years, respectively (log rank: P=.01). Using Cox regression model, likelihood ratio test, treatment was the most important predictor of LC (P=.0002) and eye preservation (P=.01). CPT was a significant predictor of prolonged disease-free survival (log rank: P=.001). Conclusions: Particle therapy resulted in significantly improved local control, eye preservation, and disease-free survival as confirmed by long-term outcomes from the only randomized study available to date comparing radiation modalities in choroidal and ciliary body melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Therapy Did Not Induce Long-Term Changes in Rectal Mucosa: Results From the Randomized Scandinavian Prostate Cancer Group 7 Trial

Purpose: To investigate long-term changes in the rectal mucosa after curative external beam radiation therapy in the treatment of prostate cancer. Methods and Materials: In the Scandinavian Prostate Cancer Group 7 trial, 880 men with locally advanced prostate cancer were randomized to hormonal therapy alone versus hormonal therapy plus radiation therapy to 70 Gy. A subcohort from this trial being randomized at our center (n=178) was invited to a study on late anorectal side effects during 2003-2005, approximately 5 years after treatment, including measuring health-reported quality of life and physician-assessed toxicity score by the Late Effects Normal Tissue Task Force/Subjective, Objective, Management, Analytic (LENT/SOMA) and European Organization for Research and Treatment of Cancer/Radiation Therapy Oncology Group score. Sixty-seven patients had a rectal mucosa biopsy. Sixty-four biopsies were included in the final analysis, of which 33 patients were randomized to hormonal treatment and 31 to hormonal treatment plus radiation therapy. The presence of fibrosis, number of capillaries, and lymphocyte infiltration was then evaluated by light microscopy. Results: The group receiving radiation therapy had significantly higher LENT/SOMA and function/bother scale scores than the group that only received hormonal treatment, but there was no significant difference in the presence of fibrosis, ectasia, number of capillaries in the lamina propria, or lymphocyte infiltration between the groups. Conclusion: Radiation therapy to 70 Gy to the prostate does not induce long-term microscopic mucosal changes in the rectum 5 years after treatment. This is in contrast to the general assumption that structural changes, including fibrosis, seen after radiation therapy include the mucosa. We speculate that the main late effects of radiation therapy on the structure of the rectum are located in the deeper layers of the rectal wall than the mucosa.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Guided Planning for Prostate Carcinomas With Incorporation of Anti-3-[18F]FACBC (Fluciclovine) Positron Emission Tomography: Workflow and Initial Findings From a Randomized Trial

Purpose: {sup 18}F-Fluciclovine (anti-1-amino-3-[{sup 18}F]fluorocyclobutane-1-carboxylic acid) is a novel positron emission tomography (PET)/computed tomography (CT) radiotracer that has demonstrated utility for detection of prostate cancer. Our goal is to report the initial results from a randomized controlled trial of the integration of {sup 18}F-fluciclovine PET-CT into treatment planning for defining prostate bed and lymph node target volumes. Methods and Materials: We report our initial findings from a cohort of 41 patients, of the first enrolled on a randomized controlled trial, who were randomized to the {sup 18}F-fluciclovine arm. All patients underwent {sup 18}F-fluciclovine PET-CT for the detection of metabolic abnormalities and high-resolution CT for treatment planning. The 2 datasets were registered first by use of a rigid registration. If soft tissue displacement was observable, the rigid registration was improved with a deformable registration. Each {sup 18}F-fluciclovine abnormality was segmented as a percentage of the maximum standard uptake value (SUV) within a small region of interest around the lesion. The percentage best describing the SUV falloff was integrated in planning by expanding standard target volumes with the PET abnormality. Results: In 21 of 55 abnormalities, a deformable registration was needed to map the {sup 18}F-fluciclovine activity into the simulation CT. The most selected percentage was 50% of maximum SUV, although values ranging from 15% to 70% were used for specific patients, illustrating the need for a per-patient selection of a threshold SUV value. The inclusion of {sup 18}F-fluciclovine changed the planning volumes for 46 abnormalities (83%) of the total 55, with 28 (51%) located in the lymph nodes, 11 (20%) in the prostate bed, 10 (18%) in the prostate, and 6 (11%) in the seminal vesicles. Only 9 PET abnormalities were fully contained in the standard target volumes based on the CT-based segmentations and did not necessitate expansion. Conclusions: The use of {sup 18}F-fluciclovine in postprostatectomy radiation therapy planning was feasible and led to augmentation of the target volumes in the majority (30 of 41) of the patients studied.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Results of a Randomized Phase 2 Trial Investigating the Addition of Cetuximab to Induction Chemotherapy and Accelerated or Hyperfractionated Chemoradiation for Locoregionally Advanced Head and Neck Cancer

Purpose: The role of cetuximab in the treatment of locoregionally advanced head and neck squamous cell cancer (LA-HNSCC) remains poorly defined. In this phase 2 randomized study, we investigated the addition of cetuximab to both induction chemotherapy (IC) and hyperfractionated or accelerated chemoradiation. Methods and Materials: Patients with LA-HNSCC were randomized to receive 2 cycles of weekly IC (cetuximab, paclitaxel, carboplatin) and either Cetux-FHX (concurrent cetuximab, 5-fluorouracil, hydroxyurea, and 1.5 Gy twice-daily radiation therapy every other week to 75 Gy) or Cetux-PX (cetuximab, cisplatin, and accelerated radiation therapy with delayed concomitant boost to 72 Gy in 42 fractions). The primary endpoint was progression-free survival (PFS), with superiority compared with historical control achieved if either arm had 2-year PFS ≥70%. Results: 110 patients were randomly assigned to either Cetux-FHX (n=57) or Cetux-PX (n=53). The overall response rate to IC was 91%. Severe toxicity on IC was limited to rash (23% grade ≥3) and myelosuppression (38% grade ≥3 neutropenia). The 2-year rates of PFS for both Cetux-FHX (82.5%) and Cetux-PX (84.9%) were significantly higher than for historical control (P<.001). The 2-year overall survival (OS) was 91.2% for Cetux-FHX and 94.3% for Cetux-PX. With a median follow-up time of 72 months, there were no significant differences in PFS (P=.35) or OS (P=.15) between the treatment arms. The late outcomes for the entire cohort included 5-year PFS, OS, locoregional failure, and distant metastasis rates of 74.1%, 80.3%, 15.7%, and 7.4%, respectively. The 5-year PFS and OS were 84.4% and 91.3%, respectively, among human papillomavirus (HPV)-positive patients and 65.9% and 72.5%, respectively, among HPV-negative patients. Conclusions: The addition of cetuximab to IC and chemoradiation was tolerable and produced long-term control of LA-HNSCC, particularly among poor-prognosis HPV-negative patients. Further investigation of cetuximab may be warranted in the neoadjuvant setting and with non–platinum-based chemoradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterisation of the spatial variability of material properties of Gilsocarbon and NBG-18 using random fields

Graphite is a candidate material for Generation IV concepts and is used as a moderator in Advanced Gas-cooled Reactors (AGR) in the UK. Spatial material variability is present within billets causing different material property values between different components. Variations in material properties and irradiation effects can produce stress concentrations and diverse mechanical responses in a nuclear reactor graphite core. In order to characterise the material variability, geostatistical techniques called variography and random field theory were adapted for studying the density and Young's modulus of a billet of Gilsocarbon and NBG-18 graphite grades. Variography is a technique for estimating the distance over which material property values have significant spatial correlation, known as the scale of fluctuation or spatial correlation length. The paper uses random field theory to create models that mimic the original spatial and statistical distributions of the original data set. This study found different values of correlation length for density and Young's modulus around the edges of a Gilsocarbon billet, while in the case of NBG-18, similar correlation lengths where found across the billet. Furthermore examples of several random fields are given to reproduce the spatial patterns and values found in the original data.

36 MATERIALS SCIENCE↗

Grain boundary inter-connections in polycrystalline aluminum with random orientation

Highlights: • The GBICs in a pure aluminum are not random, showing remarkable preference on the planes of low Miller index. • {1 1 1}/{1 1 1} is the most frequent GBIC in pure aluminum. • {1 1 1}/{1 1 1} GBIC is mainly coming from the GBs formed by rotations around , and axes. • {1 1 1}/{1 1 1} GBIC possesses higher PCSD and definite dislocation structures compared to the general GBs. • To pursue {1 1 1}/{1 1 1} GBIC is a pint-cut for the GBE research in high stacking fault energy FCC materials. - Abstract: Grain boundary inter-connection (GBIC) is the matching of two crystallographic planes from two abutting grains ending on the grain boundary (GB) position in polycrystalline materials, which can be expressed as {h_1k_1l_1}/{h_2k_2l_2}. GBIC is the critical parameter that intrinsically defines the character and properties of a GB. In current work, a zone-melted polycrystalline aluminum bar with a purity higher than 99.99% (mass fraction) was subjected to a multi-directional forging (MDF) with a true strain of 4 followed by a recrystallization annealing at 360 °C. Such process repeated at least 4 times until an equiaxed-grain microstructure with random orientation and averaged grain size approximate 30 μm was achieved. Then the GBICs were determined by electron backscatter diffraction (EBSD) measurement and stereology-based five-parameter analysis (FPA) coupled with crystallographic analysis after the grain boundaries (GBs) were filtered according to their misorientations (e.g. angle/axis pair). The results revealed that the GBICs for any group of GBs with a given misorientation are not random, showing remarkable preference on the planes of low Miller index forming mixed and twist GBs. The work also demonstrated that among the high angle boundaries (HABs), {1 1 1}/{1 1 1}, including coherent ∑3 boundaries, is the most frequent GBIC, mainly due to the GBs formed by rotations around <1 1 1>, <1 2 2> and <1 1 2> axes. Near coincidence site (NCS) and O-lattice theory analyses indicate that the {1 1 1}/{1 1 1} GBICs usually possess higher planar coincidence site density (PCSD) and definite dislocation structures compared to the general GBs, implying their more structural stability when only crystallography is taken into account. This result agrees very well with the recent results obtained by molecular dynamic simulations. It is significant to the grain boundary engineering (GBE) in the high stacking fault energy (SFE) face-centered cubic (FCC) materials such as aluminum and its alloys.

36 MATERIALS SCIENCE↗

Using porous random fields to predict the elastic modulus of unoxidized and oxidized superfine graphite

Nuclear graphite is a candidate material for Generation IV nuclear power plants. Porous materials such as graphite can contain complex networks of pores that influence the material's mechanical and irradiation response. A methodology known as the random finite element method (RFEM) was adapted to create synthetic microstructures and predict the influence of porosity on the elastic properties of graphite during oxidation. RFEM combines random field theory and the finite element method in a Monte Carlo framework to estimate the mechanical response of a given grade of graphite. In this research, the random fields were verified through experimental characterization to predict the elastic response of three nuclear graphite grades, ETU-10, IG-110, and 2114. Finite element models (FEM) were generated using segmentations of x-ray computed tomography (XCT) data known as image-based models (IBMs) to validate and compare with the RFEM results and better understand the effects of uniform oxidation in these graphite grades. The RFEM predictions appear to correlate well with the experimental values of the measured Young’s modulus of the three graphite grades and display the same trends as IBMs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of Electron Microscopes with Binary Pseudo-random Multilayer Test Samples

Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [1] and [2] and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi2/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pairwise interaction extended point-particle model for a random array of monodisperse spheres

This study introduces a new point-particle force model that attempts to account for the hydrodynamic influence of the neighbouring particles in an Eulerian–Lagrangian simulation. In previous point-particle models the force on a particle depends only on Reynolds number and mean volume fraction. Thus, as long as the mean local volume fraction is the same, the force on different particles will be estimated to be the same, even though the precise arrangement of neighbours can be vastly different. From direct numerical simulation (DNS) it has been observed that in a random arrangement of spheres that were distributed with uniform probability, the particle-to-particle variation in force can be as large as the mean drag. Since the Reynolds number and mean volume fraction of all the particles within the array are the same, the standard models fail to account for the significant particle-to-particle force variation within the random array. Here, we develop a model which can compute the drag and lateral forces on each particle by accounting for the precise location of a few surrounding neighbours. A pairwise interaction is assumed where the perturbation flow induced by each neighbour is considered separately, then the effects of all neighbours are linearly superposed to obtain the total perturbation. Faxén correction is used to quantify the force perturbation due to the presence of the neighbours. The single neighbour perturbations are mapped in the vicinity of a reference sphere and stored as libraries. We test the pairwise interaction extended point-particle (PIEP) model for random arrays at two different volume fractions of $\unicode[STIX]{x1D719}=0.1$ and 0.21 and Reynolds numbers in the range $16.5\leqslant Re\leqslant 170$ . The PIEP model predictions are compared against drag and lift forces obtained from the fully resolved DNS simulations performed using the immersed boundary method. Although not perfect, we observe the PIEP model prediction to correlate much better with the DNS results than the classical mean drag model prediction.

Mechanics↗

The hidden structure of hydrodynamic transport in random fracture networks

We study the large-scale dynamics and prediction of hydrodynamic transport in random fracture networks. The flow and transport behaviour is characterized by first passage times and displacement statistics, which show heavy tails and anomalous dispersion with a strong dependence on the injection condition. The origin of these behaviours is investigated in terms of Lagrangian velocities sampled equidistantly along particle trajectories, unlike classical sampling strategies at a constant rate. The velocity series are analysed by their copula density, the joint distribution of the velocity unit scores, which reveals a simple, albeit hidden, correlation structure that can be described by a Gaussian copula. Based on this insight, we derive a Langevin equation for the evolution of equidistant particle speeds. In this framework, particle motion is quantified by a stochastic time-domain random walk, the joint density of particle position, and speed satisfies a Klein–Kramers equation. The upscaled theory quantifies particle motion in terms of the characteristic fracture length scale and the distribution of Eulerian flow velocities. That is, it is predictive in the sense that it does not require the a priori knowledge of transport attributes. The upscaled model captures non-Fickian transport features, and their dependence on the injection conditions in terms of the velocity point statistics and average fracture length. It shows that the first passage times and displacement moments are dominated by extremes occurring at the first step. The presented approach integrates the interaction of flow and structure into a predictive model for large-scale transport in random fracture networks.

42 ENGINEERING↗

Dimensional Interpolation for Random Walk

In this work, we employ a simple and accurate dimensional interpolation formula for the shapes of random walks at D = 3 and D = 2 based on the analytically known solutions at both limits D = ∞ and D = 1. The results obtained for the radius of gyration of an arbitrary shaped object have about 2% error compared with accurate numerical results at D = 3 and D = 2. We also calculated the asphericity for a three-dimensional random walk using the dimensional interpolation formula. The results agree very well with the numerically simulated results. The method is general and can be used to estimate other properties of random walks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Formation of Disordered Cocontinuous Phases by Randomly Linked Star Copolymers

Cocontinuous polymeric nanostructures have garnered significant interest due to their ability to combine different properties of two separate polymer domains. Randomly linked copolymer networks have proven to be especially robust for formation of disordered cocontinuous phases across wide composition ranges (≈30 wt % or more). While theoretical treatments of microphase-separated networks have focused primarily on the role of random elastic forces imposed on the self-assembled nanostructures by virtue of the network architecture, experimental studies seeking to disentangle these contributions from other potential effects, such as dispersity in preferred interfacial curvatures, have been scarce. To provide insight into this matter, we here study the self-assembly of randomly linked star copolymers (RSCs), constructed by linking premade polymer arms of polystyrene (PS) and poly(d,l-lactide) (PLA) using 3, 4, and 6-functional connectors. This architecture yields similar distributions of preferred curvature as networks made using corresponding difunctional strands, but lacks the elastic forces imposed by a network architecture. Gravimetry and small-angle X-ray scattering, coupled with scanning electron microscopy, were performed to identify the percolation of PS/PLA RSCs. Remarkably, the 4-arm RSC system exhibited a disordered cocontinuous window of ≈25 wt %, indicating that dispersity in preferred curvature can in some cases be sufficient to robustly drive formation of this morphology. However, the other RSC architectures showed smaller cocontinuous ranges, which we interpret in terms of the influence of homopolymer stars in the 3-arm case and the narrower distribution of preferred interfacial curvatures in the 6-arm case. Finally, thin layers of interconnected porous PS were achieved by solution-processing, suggesting that RSCs have the potential to serve as a robust and easily processable cocontinuous polymeric nanomaterials in both bulk and membrane geometries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermodynamic Model of Solvent Effects in Semiflexible Diblock and Random Copolymer Assembly

Here, we present a field-theoretic model to predict the equilibrium thermodynamic behavior of semiflexible diblock copolymers and random copolymers in the presence of solvent. We find that in both systems polymer–solvent contacts dramatically influence the thermodynamic behavior with decreasing the copolymer segment length (i.e., molecular weight). When a copolymer has unequal monomer composition, both polymer length and solvent concentration have a strong influence on the phase transition spinodal and magnitude of the critical wave modes. Diblock copolymers exhibit an expanded region of the lamellar phase in the phase diagram with decreasing chain length and polymer concentration. Such effects suggest a breakdown of the dilute approximation for solutions of short diblock copolymers. Random copolymer solutions also exhibit changes in the phase-transition spinodal and critical wave mode at asymmetric chemical compositions. This effect is highly relevant to most random copolymer materials, since a monomer is typically a low-molecular-weight chemical unit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗