Search NASA⌕ Search

SEARCH · Search NASA

Results for “Resilient estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

492 records · Page 28

High-Resolution Wind Resource Data Set of the Greater Puerto Rico Region

In February 2022, the U.S. Department of Energy and six national laboratories launched the Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100). PR100 aims to provide a comprehensive analysis of possible pathways for Puerto Rico's energy future, with a goal of 100% renewable energy by 2050. As a part of the renewable energy potential assessment in this project, we developed 20 years (2001-2020) of data using a numerical weather prediction (NWP) model for onshore and offshore wind resource assessment for the Puerto Rico. The research steps in developing the long-term wind resource data sets based on the NWP model were: 1. Model wind resource based on the Weather Research and Forecasting (WRF) model. 2. Develop WRF model configurations for Puerto Rico. 3. Test WRF with 11 different physics parameterizations for planetary boundary layer (PBL). 4. Assess WRF output from the different PBL schemes against observations. 5. Select a final model configuration which can produce the modeled wind speed with sufficient accuracy. 6. Produce 20 years wind resource data sets for Puerto Rico region. In the first stage of our framework for developing wind resource data, we developed a WRF model configuration using two nested domains (9 km and 3 km) to cover Puerto Rico and U.S. Virgin Islands and downscale the ERA5 reanalysis data (0.25 degrees x 0.25 degrees; hourly interval) to a 3-km domain. For the second stage, we implemented one-year simulations focused on using 11 different PBL physics parameterizations to find a combination of WRF physics parameterizations that could provide accurately modeled wind speed for Puerto Rico. We also analyzed the sensitivity of the modeled wind speed to PBL schemes for onshore and offshore locations. The WRF output resulting from the 11 WRF experiments using different PBL parameterizations were evaluated against observations obtained from the National Data Buoy Center (NDBC) as well as at hub height for a location for which measurements were available. A final model setup selected through the validation with observational data was used to produce 20 years of data with 3-km spatial and 5-minute temporal resolution. The WRF model output was post-processed to include wind profiles and basic atmospheric variables in a format that can be easily used for downstream modeling. The 20 years of wind resource data will be made available through NREL and support the estimation of wind energy development costs for the PR100 study.

17 WIND ENERGY↗

Developing an Automated Uncertainty Quantification Tool to Improve Watershed-Scale Predictions of Water and Nutrient Cycling

Managing the flow of water, nutrients, and contaminants in watersheds is vital to addressing pressing issues related to water scarcity, access to clean drinking water, energy production, resilience to natural and anthropogenic perturbations, and ecological restoration. Decisions about the management of watersheds critically depend on the accuracy with which the flow of water and chemicals through the watershed can be predicted by computer models. Prediction uncertainty can be reduced by matching the model to data, which are collected in the field at great expense. The contribution of watershed characterization data to reducing uncertainty of relevant model predictions can be evaluated in a so-called data-worth analysis, which provides transparent, quantitative metrics about a data set’s value for the support of relevant watershed management objectives. To achieve this goal, we developed a software package that implements the data-worth analysis approach for use with state-of-the-art watershed models. The purpose of the proposed data-worth analysis is to help decision-makers allocate resources for watershed characterization such that the uncertainty in model predictions can be significantly reduced, which leads to better, more effective management decisions. At the same time, watershed characterization costs can be reduced. The specific technical objectives of this SBIR/STTR Phase II project were to develop a framework and associated software toolsets that implement the uncertainty quantification and data-worth analysis approach for use with state-of-the-art watershed models. This goal was achieved by (A) developing a user-friendly, robust software package that is accessible to a wide audience, including watershed managers, policy-makers, and public stakeholders; (B) by demonstrating application of the prototype on several use cases that are representative of complex watershed management challenges spanning a range of scales and that consider different open-source, DOE-based codes and other modeling platforms; and (C) by gathering information about the needs and requirements from potential users to help guide future developments, ensuring that the final product will be commercially viable. The developed software consists of a graphical user interface that guides the user through a sequence of analysis steps, supported by toolsets that leverage state-of-the-art computational simulation-optimization capabilities. A prototype of the software runs on multiple platforms (PC, Mac, multi-processor Linux environment), is linked to diverse watershed simulators (e.g., ECOSYS, TOUGH2, TOUGHREACT, Amanzi-ATS), performs multiple analysis tasks (predictive simulations, sensitivity analysis, uncertainty analysis, automatic parameter estimation, and data-worth analysis, multicomponent geothermometry), and is readily extensible to include external simulators and analysis tools. The software is being commercialized and will be continually updated to address user needs.

58 GEOSCIENCES↗

Cost Analysis of Wind and Uranium from Seawater Acquisition symbiotic Infrastructure using Shell Enclosures

At current consumption rates, global conventional reserves of uranium, estimated to be 7.6 million tonnes, could be depleted in a little over a century. As these reserves decrease, extraction of uranium is expected to shift to lower quality sites, resulting in higher extraction costs and greater environmental impact. Fortunately, the ocean contains approximately 4.5 billion tonnes of uranium, as uranyl ions at low concentrations of about 3 ppb. Uranium from seawater is a widely studied topic due to the long term security it can assure the nuclear fuel cycle. Additionally, harvesting uranium from seawater could reduce some of the environmental impacts associated with the recovery of land-based uranium. Seawater uranium is meant to create a cost ceiling that provides economic stability and potential savings, not to act as a direct competitor to terrestrial uranium. A recent review of uranium recovery technologies by found uranium adsorption by chelating polymers to be the most promising in terms of adsorbent capacity, environmental footprint, and cost. In this technology, chelating polymers are deployed in seawater and remain submerged until the amount of captured uranium approaches the adsorption capacity. Then, an elution bath is used to strip metal ions, such as uranium, off the adsorbent polymer. A polymer may be immersed in a number of elution baths before it is regenerated by an alkali wash to free its functional groups, allowing for the reuse of the polymer. The output from the elution process undergoes purification and precipitation typical for mined uranium to produce yellowcake. Offshore systems for the extraction of uranium from seawater have been developed since the early 2000's. The system currently studied by a nationwide consortium of national laboratory and university partners utilizes continuous adsorbent polyethylene fibers that are braided around a porous polypropylene float which can be made into long lengths. However, because this deployment scheme requires the adsorbent be brought to a mother-ship for the elution process and redeployed afterward, it has significant practical and economic deployment challenges. Detailed economic analysis have identified the adsorbent production and mooring as the most expensive components of the recovery process. Based on these results, proposed an alternative deployment method that is attached to an offshore wind turbine and continuously takes the adsorbent, that is fabricated into a belt, from the ocean through an elution process and before submerging it back into the sea. However, it has been found that adsorbents with high tensile strength and durability often have very low uranium adsorption properties. Hence, the Wind and Uranium from Seawater Acquisition symbiotic Infrastructure (WUSABI) previously studied, which requires the adsorbent into a belt held in tension, could face difficulties in an ocean environment. Instead, the design, further referred to in this paper as WUSABI-Koosh, utilized a two-part system to decouple the mechanical and chemical needs of an adsorbent for seawater harvesting of uranium. In these designs, the uranium adsorbent material with high adsorbent capacity is enclosed in a hard permeable outer shell with sufficient mechanical strength and durability for use in an offshore environment and chemical resilience against elution treatments. The integration of the design of a uranium harvesting system into an offshore wind turbine tower is pursued because the development of offshore wind or uranium harvesting by themselves bears a high capital cost for the structures, but if the mooring function can be shared, the overall cost for each will be lower. Furthermore, initial design analysis and prototyping of these symbiotic systems has proven they are technically feasible. This paper presents preliminary cost analysis for comparison to uranium recovery via alternative deployment schemes.

07 ISOTOPE AND RADIATION SOURCES↗

Critical Minerals and Rare Earth Elements in Powder River Basin Coal and Associated Sediments, Wyoming, USA

The demand for Rare Earth Elements (REE) and other critical minerals (CM) required for consumer products, defense-related applications, and low-carbon energy technology is increasing rapidly. Unconventional sources of REE/CM, such as coal and associated sediments, could prove very important in building resilient and ethical energy supply chains. Utilization of existing infrastructure and the highly trained energy workforce in traditionally coal-producing regions in emerging REE/CM industries could provide an economic boost to coal communities. The Powder River Basin (PRB) of Wyoming and Montana, USA, is a prime candidate to investigate the feasibility of extracting REE/CM from coal and associated sediments. The PRB hosts thick (>50 ft) coal seams that are mined at the surface and more than 40% of the coal produced in the US comes from the PRB. Geochemical data from multiple locations in PRB coal systems show REE enrichments at the top and bottom margins and at internal partings in coal seams. This trend is exhibited in two cores drilled at Peabody’s North Antelope Rochelle mine in the east central PRB, the largest coal mine in the world. The two cores include the Wyodak Anderson coal zone as well as the over- and underlying shale units. The Wyodak Anderson coal zone is part of the Paleocene Tongue River Member of the Fort Union Formation in which most of the coal resources in the PRB reside. To understand REE/CM enrichment, a total of 188 samples were analyzed for their major and trace element chemistry from both cores, sampled at one foot or smaller intervals. The two cores show distinct REE enrichments in the uppermost and lowermost 3 to 12 feet of the Wyodak Anderson coal zone, as well as enrichments in bounding carbonaceous shale units. Total REE+Y (REY) concentrations as high as 2510 ppm (all concentrations reported on an ash basis), or 15 times average upper continental crust values (Taylor and McLennan, 1995), were identified in the coal. Partings within the coal zone also show relative REE enrichment, with concentrations up to 485 ppm REY. The remaining interior portions of the coal zone contain lower concentrations of REE, resulting in an average REY for all samples from both cores of 288 ppm. The proportion of high-value critical REE (Nd, Eu, Tb, Dy, Er, Y) compared to REY averages 36%, which is higher than the critical REE proportion in average upper continental crust of 33%. This finding highlights the relative enrichment of middle REE compared to light REE, in contrast to many conventional REE deposits. Other critical trace elements that show enrichments above average upper continental crust include Ga, Nb, and V. Within this sample suite, Ga concentrations range from 2.8 to 213 ppm, with an average of 29 ppm; Nb from 2.9 to 166 ppm with an average of 26 ppm; and V from 27 to 1695 ppm with an average of 188 ppm. None of these trace elements exhibit the same distinct pattern of enrichment as REE in the upper and lower bounding layers and internal partings of the coal zone. Major element chemistry indicates CaO concentrations averaging ~25% in the coal samples from both cores, which has important implications for the extractability of REE from coal. Calcium-rich PRB coal has been shown to be more amenable to REE extraction than lower calcium coals by some methods (Stuckman et al., 2019; Taggart et al., 2016), highlighting the importance of REE extractability in addition to REE concentration in assessing the value of potential feedstocks. The original coal resource in the PRB is estimated at 1.16 trillion short tons (Luppens et al., 2015). Thus, the PRB represents an important potential unconventional source for REE and other CM. Ongoing research to fully characterize the REE/CM resource, identify enrichment mechanisms, and further develop and scale extraction technologies is necessary to understand the full potential of this resource.

Phillips, Erin↗

Monitoring Soil Erosion on a Burned Site in the Mojave-Great Basin Transition Zone: Final Report for the Jacob Fire Site

A historic return interval of 100 years for large fires in the U.S. southwestern deserts is being replaced by one where fires may reoccur as frequently as every 20 to 30 years. The shortened return interval, which translates to an increase in fires, has implications for management of Soil Corrective Action Units (CAUs) and Corrective Action Sites (CASs) for which the Department of Energy, National Nuclear Security Administration Nevada Field Office has responsibility. A series of studies was initiated at uncontaminated analog sites to better understand the possible impacts of erosion and transport by wind and water should contaminated soil sites burn. The first of these studies was undertaken at the Jacob Fire site approximately 12 kilometers (7.5 miles) north of Hiko, Nevada. A lightning-caused fire burned approximately 200 hectares during August 6-8, 2008. The site is representative of a transition between Mojave and Great Basin desert ecoregions on the Nevada National Security Site (NNSS), where the largest number of Soil CAUs/CASs are located. The area that burned at the Jacob Fire site was primarily a Coleogyne ramosissima (blackbrush) and Ephedra nevadensis (Mormon tea) community, also an abundant shrub assemblage in the similar transition zone on the NNSS. This report summarizes three years of measurements after the fire. Seven measurement campaigns at the Jacob Fire site were completed. Measurements were made on burned ridge (upland) and drainage sites, and on burned and unburned sites beneath and between vegetation. A Portable In-Situ Wind Erosion Lab (PI-SWERL) was used to estimate emissions of suspended particles at different wind speeds. Context for these measurements was provided through a meteorological tower that was installed at the Jacob Fire site to obtain local, relevant environmental parameters. Filter samples, collected from the exhaust of the PI-SWERL during measurements, were analyzed for chemical composition. Runoff and water erosion were quantified through a series of rainfall/runoff simulation tests in which controlled amounts of water were delivered to the soil surface in a specified amount of time. Runoff data were collected from understory and interspace soils on burned ridge and drainage areas. Runoff volume and suspended sediment in the runoff were sampled; the particle size distribution of the sediment was determined by laboratory analysis. Several land surface and soil characteristics associated with runoff were integrated by the calculation of site-specific curve numbers. Several vegetation surveys were conducted to assess post-burn recovery. Data from plots in both burned and unburned areas included species identification, counts, and location. Characterization of fire-affected area included measures at both the landscape scale and at specific sites. Although wind erosion measurements indicate that there are seasonal influences on almost all parameters measured, several trends were observed. PI-SWERL measurements indicated the potential for PM 10 windblown dust emissions was higher on areas that were burned compared to areas that were not. Among the burned areas, understory soils in drainage areas were the most emissive, and interspace soils along burned ridges were least emissive. By 34 months after the burn (MAB), at the end of the study, emissions from all burned soil sites were virtually indistinguishable from unburned levels. Like the amount of emissions, the chemical signature of the fire (indicated by the EC-Soil ratio) was elevated immediately after the fire and approached pre-burn levels by 24 MAB. Thus, the potential for wind erosion at the Jacob Fire site, as measured by the amount and type of emissions, increased significantly after the fire and returned to unburned levels by 24 MAB. The effect of fire on the potential for water erosion at the Jacob Fire site was more ambiguous. Runoff and sediment from ridge interspace soils and unburned interspace soils were similar throughout the study period. Seldom, if ever, did runoff and sediment occur in burned drainage area soils. For burned soils where runoff occurred at 1 MAB, the sediment size was finer than on unburned sites, but this effect disappeared by 3 MAB. For the three year study under the conditions tested at the Jacob Fire site, the potential for water erosion appeared relatively unaffected by the fire. Vegetation responses were documented for each year following the fire. By the end of the study, there was a substantial difference in plant densities and richness between drainage and ridge sites. Cheatgrass densities were higher in unburned plots, and cheatgrass was also more dominant in the community composition in unburned plots. Cheatgrass had increased in the burned area but so did other native species. Three years after the fire, the burned landscape continued to revegetate but had yet to approximate the condition of an unburned landscape. The results from the vegetation surveys support the wind erosion results, where the primary source of windborne particles originate from the understory, where lower plant diversity and densities were found. The soil appears to be more resilient and have a much shorter recovery time than the vegetation in this particular community.

54 ENVIRONMENTAL SCIENCES↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗