Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCANNING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Chronic recording of regenerating VIIIth nerve axons with a sieve electrode

A micromachined silicon substrate sieve electrode was implanted within transected toadfish (Opsanus tau) otolith nerves. High fidelity, single unit neural activity was recorded from seven alert and unrestrained fish 30 to 60 days after implantation. Fibrous coatings of genetically engineered bioactive protein polymers and nerve guide tubes increased the number of axons regenerating through the electrode pores when compared with controls. Sieve electrodes have potential as permanent interfaces to the nervous system and to bridge missing connections between severed or damaged nerves and muscles. Recorded impulses might also be amplified and used to control prosthetic devices.

NASA Discipline Neuroscience↗

NASA Tech Briefs, May 2012

Topics covered include: An "Inefficient Fin" Non-Dimensional Parameter to Measure Gas Temperatures Efficiently; On-Wafer Measurement of a Multi-Stage MMIC Amplifier with 10 dB of Gain at 475 GHz; Software to Control and Monitor Gas Streams; Miniaturized Laser Heterodyne Radiometer (LHR) for Measurements of Greenhouse Gases in the Atmospheric Column; Anomaly Detection in Test Equipment via Sliding Mode Observers; Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems; Goldstone Solar System Radar Waveform Generator; Fast and Adaptive Lossless Onboard Hyperspectral Data Compression System; Iridium Interfacial Stack - IrIS; Downsampling Photodetector Array with Windowing; Optical Phase Recovery and Locking in a PPM Laser Communication Link; High-Speed Edge-Detecting Line Scan Smart Camera; Optical Communications Channel Combiner; Development of Thermal Infrared Sensor to Supplement Operational Land Imager; Amplitude-Stabilized Oscillator for a Capacitance-Probe Electrometer; Automated Performance Characterization of DSN System Frequency Stability Using Spacecraft Tracking Data; Histogrammatic Method for Determining Relative Abundance of Input Gas Pulse; Predictive Sea State Estimation for Automated Ride Control and Handling - PSSEARCH; LEGION: Lightweight Expandable Group of Independently Operating Nodes; Real-Time Projection to Verify Plan Success During Execution; Automated Performance Characterization of DSN System Frequency Stability Using Spacecraft Tracking Data; Web-Based Customizable Viewer for Mars Network Overflight Opportunities; Fabrication of a Cryogenic Terahertz Emitter for Bolometer Focal Plane Calibrations; Fabrication of an Absorber-Coupled MKID Detector; Graphene Transparent Conductive Electrodes for Next- Generation Microshutter Arrays; Method of Bonding Optical Elements with Near-Zero Displacement; Free-Mass and Interface Configurations of Hammering Mechanisms; Wavefront Compensation Segmented Mirror Sensing and Control; Long-Life, Lightweight, Multi-Roller Traction Drives for Planetary Vehicle Surface Exploration; Reliable Optical Pump Architecture for Highly Coherent Lasers Used in Space Metrology Applications; Electrochemical Ultracapacitors Using Graphitic Nanostacks; Improved Whole-Blood-Staining Device; Monitoring Location and Angular Orientation of a Pill; Molecular Technique to Reduce PCR Bias for Deeper Understanding of Microbial Diversity; Laser Ablation Electrodynamic Ion Funnel for In Situ Mass Spectrometry on Mars; High-Altitude MMIC Sounding Radiometer for the Global Hawk Unmanned Aerial Vehicle; PRTs and Their Bonding for Long-Duration, Extreme-Temperature Environments; Mid- and Long-IR Broadband Quantum Well Photodetector; 3D Display Using Conjugated Multiband Bandpass Filters; Real-Time, Non-Intrusive Detection of Liquid Nitrogen in Liquid Oxygen at High Pressure and High Flow; Method to Enhance the Operation of an Optical Inspection Instrument Using Spatial Light Modulators; Dual-Compartment Inflatable Suitlock; Large-Strain Transparent Magnetoactive Polymer Nanocomposites; Thermodynamic Vent System for an On-Orbit Cryogenic Reaction Control Engine; Time Distribution Using SpaceWire in the SCaN Testbed on ISS; and Techniques for Solution- Assisted Optical Contacting.

Source record↗

Calibration of the SHERLOC Deep Ultraviolet Fluorescence–Raman Spectrometer on the Perseverance Rover

We describe the wavelength calibration of the spectrometer for the scanning of habitable environments with Raman and luminescence for organics and chemicals (SHERLOC) instrument onboard NASA’s Perseverance Rover. SHERLOC utilizes deep ultraviolet Raman and fluorescence (DUV R/F) spectroscopy to enable analysis of samples from the Martian surface. SHERLOC employs a 248.6 nm deep ultraviolet laser to generate Raman-scattered photons and native fluorescence emission photons from near-surface material to detect and classify chemical and mineralogical compositions. The collected photons are focused on a charge-coupled device and the data are returned to Earth for analysis. The compact DUV R/F spectrometer has a spectral range from 249.9 nm to 353.6 nm (200 cm1 to 12, 000 cm1) (with a spectral resolution of 0.296 nm (40 cm1)). The compact spectrometer uses a custom design to project a high-resolution Raman spectrum and a low-resolution fluorescence spectrum on a single charge-coupled device. The natural spectral separation enabled by deep ultraviolet excitation enables wavelength separation of the Raman/fluorescence spectra. The SHERLOC spectrometer was designed to optimize the resolution of the Raman spectral region and the wavelength range of the fluorescence region. The resulting illumination on the charge-coupled device is curved, requiring a segmented, nonlinear wavelength calibration in order to understand the mineralogy and chemistry of Martian materials.

Kyle Uckert↗

Investigating the Ability of Plastic Current Collectors to Isolate Internal Shorts

Metallized plastic current collectors in Li-ion cells reduce mass and reduce the internal short circuit hazard compared to aluminum and copper foils. Shorts induced by nail and by our internal short circuit device were performed on control 18650 cells and on cells with the collectors replaced with metallized polyester and aramid films. Tests were performed inside our fractional thermal runaway calorimeter to quantify the heat transferred and its distributions and those runs done at a synchrotron yielded fascinating very high speedX-ray videography. These show tolerance to nail penetration and activation of defect internal shorts and when thermally forced into thermal runaway, the heat output is significantly reduced. Very high resolutionCT scans, cross sections, and cell tear downs give insights into the thermal and mechanism for these plastic collectors.

Plastic Current Collectors↗

Determination of bulk diffusion lengths for angle-lapped semiconductor material via the scanning electron microscope: A theoretical analysis

A standard procedure for the determination of the minority carrier diffusion length by means of a scanning electron microscope (SEM) consists in scanning across an angle-lapped surface of a P-N junction and measuring the resultant short circuit current I sub sc as a function of beam position. A detailed analysis of the I sub sc originating from this configuration is presented. It is found that, for a point source excitation, the I sub sc depends very simply on x, the variable distance between the surface and the junction edge. The expression for the I sub sc of a planar junction device is well known. If d, the constant distance between the plane of the surface of the semiconductor and the junction edge in the expression for the I of a planar junction is merely replaced by x, the variable distance of the corresponding angle-lapped junction, an expression results which is correct to within a small fraction of a percent as long as the angle between the surfaces, 2 theta sub 1, is smaller than 10 deg.

Vonroos, O.↗

Studies of asteroids, comets, and Jupiter's outer satellites

The work comprises observational, theoretical, and computational research on asteroids, together with a smaller effort concerning the astrometry of comets and Jupiter's satellites JVI through JXIII. Two principal areas of research, centering on astrometry and photometry, are interrelated in their aim to study the overall structure of the asteroid belt and the physical and orbital properties of individual asteroids. About 2000 accurate photographic positions of asteroids and comets, including a number from the Lowell, Palomar, and Goethe-Link archival plate collections, the last of which was donated to us last winter by Indiana University were measured and published. Charge coupled device (CCD) astrometry of 36 faint targets was undertaken, including 4 comets; JVI, JVII, JVIII, JLX, JXI, and JXII; and 26 asteroids, most of which are Earth-approachers. A deep, bias-correctable asteroid survey (LUKAS), the aim of which is to determine the true spatial distribution of asteroids down to subkilometer diameters was started. A series of eight plates at the UK Schmidt telescope that contain images of asteroids as faint as V approximately 22 mag was obtained. Analysis of microdensitometric scans of two plates has shown that about 98 percent of the asteroid images could be identified completely automatically.

Bowell, Edward↗

NASA Robotic Neurosurgery Testbed

The detection of tissue interface (e.g., normal tissue, cancer, tumor) has been limited clinically to tactile feedback, temperature monitoring, and the use of a miniature ultrasound probe for tissue differentiation during surgical operations. In neurosurgery, the needle used in the standard stereotactic CT (Computational Tomography) or MRI (Magnetic Resonance Imaging) guided brain biopsy provides no information about the tissue being sampled. The tissue sampled depends entirely upon the accuracy with which the localization provided by the preoperative CT or MRI scan is translated to the intracranial biopsy site. In addition, no information about the tissue being traversed by the needle (e.g., a blood vessel) is provided. Hemorrhage due to the biopsy needle tearing a blood vessel within the brain is the most devastating complication of stereotactic CT/MRI guided brain biopsy. A robotic neurosurgery testbed has been developed at NASA Ames Research Center as a spin-off of technologies from space, aeronautics and medical programs. The invention entitled 'Robotic Neurosurgery Leading to Multimodality Devices for Tissue Identification' is nearing a state ready for commercialization. The devices will: 1) improve diagnostic accuracy and precision of general surgery, with near term emphasis on stereotactic brain biopsy, 2) automate tissue identification, with near term emphasis on stereotactic brain biopsy, to permit remote control of the procedure, and 3) reduce morbidity for stereotactic brain biopsy. The commercial impact from this work is the potential development of a whole new generation of smart surgical tools to increase the safety, accuracy and efficiency of surgical procedures. Other potential markets include smart surgical tools for tumor ablation in neurosurgery, general exploratory surgery, prostate cancer surgery, and breast cancer surgery.

Mah, Robert↗

NASA Robotic Neurosurgery Testbed

The detection of tissue interface (e.g., normal tissue, cancer, tumor) has been limited clinically to tactile feedback, temperature monitoring, and the use of a miniature ultrasound probe for tissue differentiation during surgical operations, In neurosurgery, the needle used in the standard stereotactic CT or MRI guided brain biopsy provides no information about the tissue being sampled. The tissue sampled depends entirely upon the accuracy with which the localization provided by the preoperative CT or MRI scan is translated to the intracranial biopsy site. In addition, no information about the tissue being traversed by the needle (e.g., a blood vessel) is provided. Hemorrhage due to the biopsy needle tearing a blood vessel within the brain is the most devastating complication of stereotactic CT/MRI guided brain biopsy. A robotic neurosurgery testbed has been developed at NASA Ames Research Center as a spin-off of technologies from space, aeronautics and medical programs. The invention entitled "Robotic Neurosurgery Leading to Multimodality Devices for Tissue Identification" is nearing a state ready for commercialization. The devices will: 1) improve diagnostic accuracy and precision of general surgery, with near term emphasis on stereotactic brain biopsy, 2) automate tissue identification, with near term emphasis on stereotactic brain biopsy, to permit remote control of the procedure, and 3) reduce morbidity for stereotactic brain biopsy. The commercial impact from this work is the potential development of a whole new generation of smart surgical tools to increase the safety, accuracy and efficiency of surgical procedures. Other potential markets include smart surgical tools for tumor ablation in neurosurgery, general exploratory surgery, prostate cancer surgery, and breast cancer surgery.

Mah, Robert↗

Artifacts for Calibration of Submicron Width Measurements

Artifacts that are fabricated with the help of molecular-beam epitaxy (MBE) are undergoing development for use as dimensional calibration standards with submicron widths. Such standards are needed for calibrating instruments (principally, scanning electron microscopes and scanning probe microscopes) for measuring the widths of features in advanced integrated circuits. Dimensional calibration standards fabricated by an older process that involves lithography and etching of trenches in (110) surfaces of single-crystal silicon are generally reproducible to within dimensional tolerances of about 15 nm. It is anticipated that when the artifacts of the present type are fully developed, their critical dimensions will be reproducible to within 1 nm. These artifacts are expected to find increasing use in the semiconductor-device and integrated- circuit industries as the width tolerances on semiconductor devices shrink to a few nanometers during the next few years. Unlike in the older process, one does not rely on lithography and etching to define the critical dimensions. Instead, one relies on the inherent smoothness and flatness of MBE layers deposited under controlled conditions and defines the critical dimensions as the thicknesses of such layers. An artifact of the present type is fabricated in two stages (see figure): In the first stage, a multilayer epitaxial wafer is grown on a very flat substrate. In the second stage, the wafer is cleaved to expose the layers, then the exposed layers are differentially etched (taking advantage of large differences between the etch rates of the different epitaxial layer materials). The resulting structure includes narrow and well-defined trenches and a shelf with thicknesses determined by the thicknesses of the epitaxial layers from which they were etched. Eventually, it should be possible to add a third fabrication stage in which durable, electronically inert artifacts could be replicated in diamondlike carbon from a master made by MBE and etching as described above.

Grunthaner, Frank↗

Microstructure-Sensitive Investigation of Fracture Using Acoustic Emission Coupled With Electron Microscopy

A novel technique using Scanning Electron Microscopy (SEM) in conjunction with Acoustic Emission (AE) monitoring is proposed to investigate microstructure-sensitive fatigue and fracture of metals. The coupling between quasi in situ microscopy with actual in situ nondestructive evaluation falls into the ICME framework and the idea of quantitative data-driven characterization of material behavior. To validate the use of AE monitoring inside the SEM chamber, Aluminum 2024-B sharp notch specimen were tested both inside and outside the microscope using a small scale mechanical testing device. Subsequently, the same type of specimen was tested inside the SEM chamber. Load data were correlated with both AE information and observations of microcracks around grain boundaries as well as secondary cracks, voids, and slip bands. The preliminary results are in excellent agreement with similar findings at the mesoscale. Extensions of the application of this novel technique are discussed.

Wisner, Brian↗

A Summary of Airframe Results from a Fokker F28 Full-Scale Crash Test

On June 20, 2019, a full-scale crash test was conducted on a Fokker F28 MK1000 aircraft as a part of a joint NASA / Federal Aviation Administration (FAA) research effort to investigate the crashworthiness characteristics of a Transport Category Aircraft (TCA), as defined by 14 Code of Federal Regulations, Part 25. The test was conducted at NASA Langley Research Center’s Landing and Impact Research Facility and was the third in a test series to further understand TCA crashworthiness characteristics. The test article featured 24 Anthropomorphic Test Devices (ATDs, a.k.a. crash test dummies), and over 700 channels of instrumentation covering major aircraft structures such as the wings, tail, nose, cockpit and cabin, along with recording seat, overhead bin and ATD accelerations. Five different U.S. Government agencies collaborated on the test including: NASA, the FAA, the U.S. Army Research Laboratory, the National Transportation Safety Board (NTSB) and the National Highway Traffic Safety Administration (NHTSA). This report will covertest article build up, which includes weight and balance measurements and pre-test laser scans. It will also cover the events of the test, which includes the test sequence of events and post-test damage inspections. Finally, it will show airframe level accelerations at all positions measured, with discussion on correlation to the airframe damage witnessed. The test build up consisted of outfitting the main cabin section of the aircraft with 24 ATDs seated in 12 rows of seats, overhead mass and the under floor cargo area with foam representing the luggage. The main cabin also included all of the onboard data system pallets, which recorded711 channels of data from the test. All major portions of the aircraft were instrumented, including locations at the floor / frame junction locations in the cabin where the ATDs were located along with other major exterior components such as the nose, the tail, each engine cowling, and at overhead hat rack ballast locations. The aircraft impacted a soil surface at65.3 ft/s horizontal and 31.8 ft/s vertical velocities. The aircraft plowed through the soil and slid a distance of 32.5 feet from the initial impact location. There was a secondary impact occurring 0.9 s due to the “slap down” of the nose during the post-impact response. The duration of the event from impact to rest was1.62 seconds. There was major structural damage in the lower fuselage areas around the Wingbox and Aft Fuselage sections. The Aft Fuselage section deformation caused some cabin intrusion from the keel beams pushing the aft cabin floor into the cabin. Other structural deformations occurred around the tail and at transition regions in the aircraft structure; mainly in locations of differing overall stiffness. The data obtained showed average vertical accelerations between 12 and 16 g with spikes reaching almost 40 g at certain floor locations. Average horizontal accelerations were approximately 10 g for all floor locations measured with spikes reaching approximately 25 g in some locations. The report includes a full set of results on aircraft deformation and accelerations along with discussions as to the effect on the aircraft structure.

Justin D Littell↗

Micro and Nano Systems for Space Exploration

This slide presentation reviews the use of micro and nano systems in Space exploration. Included are: an explanation of the rationales behind nano and micro technologies for space exploration, a review of how the devices are fabricated, including details on lithography with more information on Electron Beam (E-Beam) lithography, and X-ray lithography, a review of micro gyroscopes and inchworm Microactuator as examples of the use of MicroElectoMechanical (MEMS) technology. Also included is information on Carbon Nanotubes, including a review of the CVD growth process. These micro-nano systems have given rise to the next generation of miniature X-ray Diffraction, X-ray Fluorescence instruments, mass spectrometers, and terahertz frequency vacuum tube oscillators and amplifiers, scanning electron microscopes and energy dispersive x-ray spectroscope. The nanotechnology has also given rise to coating technology, such as silicon nanotip anti-reflection coating.

carbon nanotubes↗

Design of a sample acquistion system for the Mars exobiological penetrator

The Mars Exobiological Penetrator will be imbedded into several locations on the Martian surface. It contains various scientific instruments, such as an Alpha-Particle Instrument (API), Differential Scanning Calorimeter (DSC), Evolved Gas Analyzer (EGA) and accelerometers. A sample is required for analysis in the API and DSC. To avoid impact contaminated material, this sample must be taken from soil greater than 2 cm away from the penetrator shell. This study examines the design of a dedicated sampling system including deployment, suspension, fore/after body coupling, sample gathering and placement. To prevent subsurface material from entering the penetrator sampling compartment during impact, a plug is placed in the exit hole of the wall. A U-lever device is used to hold this plug in the penetrator wall. The U-lever rotates upon initial motion of the core-grinder mechanism (CGM), releasing the plug. Research points to a combination of coring and grinding as a plausible solution to the problem of dry drilling. The CGM, driven by two compressed springs, will be deployed along a tracking system. A slowly varying load i.e., springs, is favored over a fixed displacement motion because of its adaptability to different material hardness. However, to accommodate sampling in a low density soil, two dash pots set a maximum transverse velocity. In addition, minimal power use is achieved by unidirectional motion of the CGM. The sample will be transported to the scientific instruments by means of a sample placement tray that is driven by a compressed spring to avoid unnecessary power usage. This paper also explores possible modifications for size, weight, and time as well as possible future studies.

Thomson, Ron↗

High-performance mass storage system for workstations

Reduced Instruction Set Computer (RISC) workstations and Personnel Computers (PC) are very popular tools for office automation, command and control, scientific analysis, database management, and many other applications. However, when using Input/Output (I/O) intensive applications, the RISC workstations and PC's are often overburdened with the tasks of collecting, staging, storing, and distributing data. Also, by using standard high-performance peripherals and storage devices, the I/O function can still be a common bottleneck process. Therefore, the high-performance mass storage system, developed by Loral AeroSys' Independent Research and Development (IR&D) engineers, can offload a RISC workstation of I/O related functions and provide high-performance I/O functions and external interfaces. The high-performance mass storage system has the capabilities to ingest high-speed real-time data, perform signal or image processing, and stage, archive, and distribute the data. This mass storage system uses a hierarchical storage structure, thus reducing the total data storage cost, while maintaining high-I/O performance. The high-performance mass storage system is a network of low-cost parallel processors and storage devices. The nodes in the network have special I/O functions such as: SCSI controller, Ethernet controller, gateway controller, RS232 controller, IEEE488 controller, and digital/analog converter. The nodes are interconnected through high-speed direct memory access links to form a network. The topology of the network is easily reconfigurable to maximize system throughput for various applications. This high-performance mass storage system takes advantage of a 'busless' architecture for maximum expandability. The mass storage system consists of magnetic disks, a WORM optical disk jukebox, and an 8mm helical scan tape to form a hierarchical storage structure. Commonly used files are kept in the magnetic disk for fast retrieval. The optical disks are used as archive media, and the tapes are used as backup media. The storage system is managed by the IEEE mass storage reference model-based UniTree software package. UniTree software will keep track of all files in the system, will automatically migrate the lesser used files to archive media, and will stage the files when needed by the system. The user can access the files without knowledge of their physical location. The high-performance mass storage system developed by Loral AeroSys will significantly boost the system I/O performance and reduce the overall data storage cost. This storage system provides a highly flexible and cost-effective architecture for a variety of applications (e.g., realtime data acquisition with a signal and image processing requirement, long-term data archiving and distribution, and image analysis and enhancement).

Chiang, T.↗

Measurement of Model Noise in a Hard-Wall Wind Tunnel

Identification, analysis, and control of fluid-mechanically-generated sound from models of aircraft and automobiles in special low-noise, semi-anechoic wind tunnels are an important research endeavor. Such studies can also be done in aerodynamic wind tunnels that have hard walls if phased microphone arrays are used to focus on the noise-source regions and reject unwanted reflections or background noise. Although it may be difficult to simulate the total flyover or drive-by noise in a closed wind tunnel, individual noise sources can be isolated and analyzed. An acoustic and aerodynamic study was made of a 7-percent-scale aircraft model in a NASA Ames 7-by-10-ft (about 2-by-3-m) wind tunnel for the purpose of identifying and attenuating airframe noise sources. Simulated landing, takeoff, and approach configurations were evaluated at Mach 0.26. Using a phased microphone array mounted in the ceiling over the inverted model, various noise sources in the high-lift system, landing gear, fins, and miscellaneous other components were located and compared for sound level and frequency at one flyover location. Numerous noise-alleviation devices and modifications of the model were evaluated. Simultaneously with acoustic measurements, aerodynamic forces were recorded to document aircraft conditions and any performance changes caused by geometric modifications. Most modern microphone-array systems function in the frequency domain in the sense that spectra of the microphone outputs are computed, then operations are performed on the matrices of microphone-signal cross-spectra. The entire acoustic field at one station in such a system is acquired quickly and interrogated during postprocessing. Beam-forming algorithms are employed to scan a plane near the model surface and locate noise sources while rejecting most background noise and spurious reflections. In the case of the system used in this study, previous studies in the wind tunnel have identified noise sources up to 19 dB below the normal background noise of the wind tunnel. Theoretical predictions of array performance are used to minimize the width and the side lobes of the beam pattern of the microphone array for a given test arrangement. To capture flyover noise of the inverted model, a 104-element microphone array in a 622-mm-diameter cluster was installed in a 19-mm-thick poly(methyl methacrylate) plate in the ceiling of the test section of the wind tunnel above the aircraft model (see Figure 1). The microphones were of the condenser type, and their diaphragms were mounted flush in the array plate, which was recessed 12.7 mm into the ceiling and covered by a porous aromatic polyamide cloth (not shown in the figure) to minimize boundary-layer noise. This design caused the level of flow noise to be much less than that of flush-mount designs. The drawback of this design was that the cloth attenuated sound somewhat and created acoustic resonances that could grow to several dB at a frequency of 10 kHz.

Soderman, Paul T.↗

Polarized-Cathodoluminescence Study Of Stress In GaAs/Si

Report describes experiments in which linearly polarized cathodoluminesce scanning electron microscopy, in both imaging and spectroscopic forms, used to analyze spatial variations in stress tensors in specimens of GaAs/Si. Specimens fabricated by atmospheric-pressure metallo-organic chemical vapor deposition of GaAs to thickness of 4 micrometers on Si substrates. Combination of mismatch between Si and GaAs crystal lattices and differential thermal contraction of materials from deposition temperature (700 degrees C) to room temperature gives rise to stresses in GaAs layer. Experiments conducted to contribute to understanding of effects of these stresses and ramifications thereof for fabrication of electronic devices in GaAs/Si system.

Rich, Daniel H.↗

Remote sensing of directional wave spectra using the surface contour radar

A unique radio-oceanographic remote sensing instrument was developed. The 36 GHz airborne Surface Contour Radar (SCR) remotely produces a real-time topographical map of the sea surface beneath the aircraft. It can routinely produce ocean directional wave spectra with off-line data processing. The transmitter is a coherent dual-frequency device that uses pulse compression to compensate for the limited available power at Ka band. The radar has selectable pulse widths of 1, 2, 4, and 10 nanoseconds. The transmitting antenna is a 58 lambda horn fed dielectric lens whose axis is parallel to the longitudinal axis of the aircraft. It illuminates an elliptical mirror which is oriented 45 deg to the lens' longitudinal axis to deflect the beam towards the region beneath the aircraft. The mirror is oscillated in a sinusoidal fashion through mechanical linkages driven to a variable speed motor to scan the transmitter beam (1.2 deg X 1.2 deg) with + or - 16 deg of the perpendicular to the aircraft wings in the plane perpendicular to the aircraft flight direction.

Walsh, E. J.↗

Software simulations of the detection of rapidly moving asteroids by a charge-coupled device

A rendezvous of an unmanned probe to an earth-approaching asteroid has been given a high priority in the planning of interplanetary missions for the 1990s. Even without a space mission, much could be learned about the history of asteroids and comet nuclei if more information were available concerning asteroids with orbits which cross or approach the orbit of earth. It is estimated that the total number of earth-crossers accessible to ground-based survey telescopes should be approximately 1000. However, in connection with the small size and rapid angular motion expected of many of these objects an average of only one object is discovered per year. Attention is given to the development of the software necessary to distinguish such rapidly moving asteroids from stars and noise in continuously scanned CCD exposures of the night sky. Model and input parameters are considered along with detector sensitivity, aspects of minimum detectable displacement, and the point-spread function of the CCD.

Mcmillan, R. S.↗