Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

A versatile and low-cost chip-to-world interface: enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device

Microfluidics offer novel and state-of-the-art pathways to process materials. Microfluidic systems drastically reduce timeframes and costs associated with traditional lab-scale efforts in the area of analytical sample preparations. The challenge arises in effectively connecting microfluidics to off-chip analysis tools to accurately characterize samples after treatment on-chip. Here, a fused silica microfluidic device (MFD) is connected to a fused-silica capillary in order to create a world-to-chip connection between the MFD and an inductively coupled plasma mass spectrometer (ICP-MS). Specifically, this is demonstrated by utilizing isotachophoresis (ITP) on a microfluidic chip to separate samples containing up to 14 lanthanides into elementally pure bands. The separated sample is successfully transferred across a 7 nL dead space at the microchip-capillary junction, such that separation resolution is maintained and even increased through the interface and into the ICP-MS, where the elemental composition of the separated sample is analysed. Lanthanide samples of varying composition are detected using ICP-MS, demonstrating this versatile and cost-effective approach that does not degrade the separation quality achieved on the MFD. This simple and inexpensive connection enables fast, low-cost sample preparation immediately prior to injection into an ICP-MS or other analytical instruments.

Lackey, Hope E.↗

Nonlinear optical thin films

A focused approach to development and evaluation of organic polymer films for use in optoelectronics is presented. The issues and challenges that are addressed include: (1) material synthesis, purification, and the tailoring of the material properties; (2) deposition of uniform thin films by a variety of methods; (3) characterization of material physical properties (thermal, electrical, optical, and electro-optical); and (4) device fabrication and testing. Photonic materials, devices, and systems were identified as critical technology areas by the Department of Commerce and the Department of Defense. This approach offers strong integration of basic material issues through engineering applications by the development of materials that can be exploited as the active unit in a variety of polymeric thin film devices. Improved materials were developed with unprecedented purity and stability. The absorptive properties can be tailored and controlled to provide significant improvement in propagation losses and nonlinear performance. Furthermore, the materials were incorporated into polymers that are highly compatible with fabrication and patterning processes for integrated optical devices and circuits. By simultaneously addressing the issues of materials development and characterization, keeping device design and fabrication in mind, many obstacles were overcome for implementation of these polymeric materials and devices into systems. We intend to considerably improve the upper use temperature, poling stability, and compatibility with silicon based devices. The principal device application that was targeted is a linear electro-optic modulation etalon. Organic polymers need to be properly designed and coupled with existing integrated circuit technology to create new photonic devices for optical communication, image processing, other laser applications such as harmonic generation, and eventually optical computing. The progression from microscopic sample to a suitable film-forming material in a working device is a complex, multifaceted endeavor. It requires close attention to maintaining the optical properties of the electro-optic active portion of the polymer while manipulating the polymer structure to obtain the desired secondary polymer properties.

Leslie, Thomas M.↗

Characterization of devices, circuits, and high-temperature superconductor transmission lines by electro-optic testing

The development of a capability for testing transmission lines, devices, and circuits using the optically-based technique of electro-optics sampling was the goal of this project. Electro-optic network analysis of a high-speed device was demonstrated. The project involved research on all of the facets necessary in order to realize this result, including the discovery of the optimum electronic pulse source, development of an adequate test fixture, improvement of the electro-optic probe tip, and identification of a device which responded at high frequency but did not oscillate in the test fixture. In addition, during the process of investigating patterned high-critical-temperature superconductors, several non-contacting techniques for the determination of the transport properties of high T(sub c) films were developed and implemented. These are a transient, optical pump-probe, time-resolved reflectivity experiment, an impulsive-stimulated Raman scattering experiment, and a terahertz-beam coherent-spectroscopy experiment. The latter technique has enabled us to measure both the complex refractive index of an MgO substrate used for high-T(sub c) films and the complex conductivity of a YBa2Cu3O(7-x) sample. This information was acquired across an extremely wide frequency range: from the microwave to the submillimeter-wave regime. The experiments on the YBCO were conducted without patterning of, or contact to, the thin film. Thus, the need for the more difficult transmission-line experiments was eliminated. Progress in all of these areas was made and is documented in a number of papers. These papers may be found in the section listing the abstracts of the publications that were issued during the course of the research.

Whitaker, John F.↗

Deuterium supersaturated surface layer in tungsten: ion energy dependence

Abstract Properties of deuterium (D) supersaturated surface layers (DSSLs) formed in tungsten (W), such as thickness, internal microstructures, and D retention, are experimentally investigated as a function of the incident ion energy, E i . W samples were exposed to D plasmas in the PISCES-A linear plasma device in a range of E i ∼ 45–175 eV, while other plasma exposure parameters were fixed: sample temperature, T s , ∼423 K, ion flux, Γ i , ∼1.2 × 10 21 m −2 s −1 , and fluence, Φ i , ∼3.0 × 10 24 m −2 . High-resolution, cross-sectional, transmission electron microscopy observations confirm that (1) a DSSL forms even at the lowest E i ∼ 45 eV, (2) the DSSL thickness, Δ t DSSL , is found to decrease with decreasing E i from ∼11–12 nm at E i ∼ 175 eV to ∼5–6 nm at ∼45 eV, and to agree with approximately the maximum implantation depth calculated using SDTrimSP, and (3) high-density D nanobubbles with a diameter of ∼1 nm or less exist inside the DSSL, which is deemed to validate a theory-predicted vacancy stabilization process due to trapping of a solute D atom(s). Utilizing a D areal density of ∼4.2 × 10 19 m −2 in the first 14 nm from the surface at E i ∼ 75 eV from nuclear reaction analysis and the measured E i dependence of Δ t DSSL , our previous laser-induced breakdown spectroscopy data is updated: both dynamic and static D retention increase with decreasing E i , and the D/W atomic fraction during plasma exposure reaches ∼0.3 at E i ∼ 45 eV. A possible DSSL formation mechanism is proposed.

Physics↗

Laboratory investigations of cloud nuclei from combustion of Space Shuttle propellant

Small quantities of solid rocket motor propellant, of the type to launch the Space Shuttle, were burned at ambient pressure in the laboratory to provide aerosol samples for characterization. A portion of each sample was injected into an isothermal cloud chamber and the remainder into a 770-liter holding tank. Portable ice nucleus (IN) counters, filter devices for IN determinations and a cloud condensation nucleus (CCN) counter sampled from the tank. The measurements show that particles resulting from the combustion of the propellant are active IN (3.3 times 10 to the 8th to 1.5 times 10 to the 11th/g active at 20 C). The portable counters and filters detected significantly fewer IN than the isothermal cloud chamber. The propellant aerosol is a prolific source of CCN that swamped the instrument.

Hindman Ii, E. E.↗

CMOS imager for pointing and tracking applications

Systems and techniques to realize pointing and tracking applications with CMOS imaging devices. In general, in one implementation, the technique includes: sampling multiple rows and multiple columns of an active pixel sensor array into a memory array (e.g., an on-chip memory array), and reading out the multiple rows and multiple columns sampled in the memory array to provide image data with reduced motion artifact. Various operation modes may be provided, including TDS, CDS, CQS, a tracking mode to read out multiple windows, and/or a mode employing a sample-first-read-later readout scheme. The tracking mode can take advantage of a diagonal switch array. The diagonal switch array, the active pixel sensor array and the memory array can be integrated onto a single imager chip with a controller. This imager device can be part of a larger imaging system for both space-based applications and terrestrial applications.

Pain, Bedabrata↗

Trace Element Sampling and Partitioning Modeling to Estimate Wastewater Composition and Treatment Performance at Coal Generators

The coal combusted at coal-fired power plants (CFPPs) contains several trace elements that impact human heath if released to the environment. Effective combinations of air pollution control devices (APCDs) and water pollution control devices (WPCDs) are critical to reducing these impacts. This work sampled pulverized CFPPs owned and operated by Louisville Gas & Electricity – Kentucky Utilities (LGE-KU) during baseload and cycling conditions. Next, an open-source and easy-to-implement trace element partitioning model was developed using publicly available datasets, literature studies of trace element partitioning, and sampling data to estimate trace element partitioning in APCDs to the gas, liquid, and solid phases exiting CFPPs. These estimates of the liquid phase trace element concentration in FGD wastewater were then used to estimate trace element behavior in WPCDs and evaluate treated wastewater effluent concentrations for compliance with the Effluent Limitation Guidelines (ELG) for the Steam Electric Generating Sector. Finally, cost estimates were developed for established and emerging wastewater treatment trains to identify the most cost-effective approaches for ELG compliance.

01 COAL, LIGNITE, AND PEAT↗

Method and Apparatus for Automated Isolation of Nucleic Acids from Small Cell Samples

RNA isolation is a ubiquitous need, driven by current emphasis on microarrays and miniaturization. With commercial systems requiring 100,000 to 1,000,000 cells for successful isolation, there is a growing need for a small-footprint, easy-to-use device that can harvest nucleic acids from much smaller cell samples (1,000 to 10,000 cells). The process of extraction of RNA from cell cultures is a complex, multi-step one, and requires timed, asynchronous operations with multiple reagents/buffers. An added complexity is the fragility of RNA (subject to degradation) and its reactivity to surface. A novel, microfluidics-based, integrated cartridge has been developed that can fully automate the complex process of RNA isolation (lyse, capture, and elute RNA) from small cell culture samples. On-cartridge cell lysis is achieved using either reagents or high-strength electric fields made possible by the miniaturized format. Traditionally, silica-based, porous-membrane formats have been used for RNA capture, requiring slow perfusion for effective capture. In this design, high efficiency capture/elution are achieved using a microsphere-based "microfluidized" format. Electrokinetic phenomena are harnessed to actively mix microspheres with the cell lysate and capture/elution buffer, providing important advantages in extraction efficiency, processing time, and operational flexibility. Successful RNA isolation was demonstrated using both suspension (HL-60) and adherent (BHK-21) cells. Novel features associated with this development are twofold. First, novel designs that execute needed processes with improved speed and efficiency were developed. These primarily encompass electric-field-driven lysis of cells. The configurations include electrode-containing constructs, or an "electrode-less" chip design, which is easy to fabricate and mitigates fouling at the electrode surface; and the "fluidized" extraction format based on electrokinetically assisted mixing and contacting of microbeads in a shape-optimized chamber. A secondary proprietary feature is in the particular layout integrating these components to perform the desired operation of RNA isolation. Apart from a novel functional capability, advantages of the innovation include reduced or eliminated use of toxic reagents, and operator-independent extraction of RNA.

Sundaram, Shivshankar↗

Programmable, four-channel, 128-sample, 40-Ms/s analog-ternary correlator

A four-channel analog-ternary CCD correlator that extends the state of the art in several important areas is discussed. Surface acoustic wave, acoustic charge transport, and CCD implementation technologies are compared, and the architecture of the CCD device is described. It is shown that, in addition to a sampling rate up to 40 Ms (megasamples) per second, a dynamic range of 66 dB, and nonlinearity below -50 dB, the device exhibits a level of integration and user-friendliness not previously available. The correlator is intended for use in communications and radar systems where pseudonoise codes are employed.

Munroe, Scott C.↗

Problem-tailored Simulation of Energy Transport on Noisy Quantum Computers

The transport of conserved quantities like spin and charge is fundamental to characterizing the behavior of quantum many-body systems. Numerically simulating such dynamics is generically challenging, which motivates the consideration of quantum computing strategies. However, the relatively high gate errors and limited coherence times of today's quantum computers pose their own challenge, highlighting the need to be frugal with quantum resources. In this work we report simulations on quantum hardware of infinite-temperature energy transport in the mixed-field Ising chain, a paradigmatic many-body system that can exhibit a range of transport behaviors at intermediate times. We consider a chain with L = 12 sites and find results broadly consistent with those from ideal circuit simulators over 90 Trotter steps, containing up to 990 entangling gates. To obtain these results, we use two key problem-tailored insights. First, we identify a convenient basis – the Pauli Y basis – in which to sample the infinite-temperature trace and provide theoretical and numerical justifications for its efficiency relative to, e.g., the computational basis. Second, in addition to a variety of problem-agnostic error mitigation strategies, we employ a renormalization strategy that compensates for global nonconservation of energy due to device noise. We discuss the applicability of the proposed sampling approach beyond the mixed-field Ising chain and formulate a variational method to search for a sampling basis with small sample-to-sample fluctuations for an arbitrary Hamiltonian. This opens the door to applying these techniques in more general models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ERDE: The Earth-Field Resonance Detection and Evaluation Devices

Researchers at Los Alamos have developed the Earth-field Resonance Detection and Evaluation devices, or ERDE (German for “Earth”) which brings portable chemical analysis and identification into the field. ERDE uses the Earth’s magnetic field to perform nuclear magnetic resonance measurements without the need for sample preparation, costly cryogens, or calibration procedures, meaning it is extremely user-friendly. In fact, using the Earth’s magnetic field allows detection and identification of chemical species through non-magnetic pipes without sampling, reducing the likelihood of costly biofouling. This innovative new device brings together these outstanding benefits to improve processes in the detection of noxious chemicals in water supplies as well as the identification of toxic materials anywhere. There are two fully-functional ERDE prototypes and efforts are underway to miniaturize the system further for improved portability, increased sensitivity, and expanded capabilities. The Laboratory is seeking qualified licensing or CRADA partners to finalize development of this system.

47 OTHER INSTRUMENTATION↗

Powder Handling Device for Analytical Instruments

Method and system for causing a powder sample in a sample holder to undergo at least one of three motions (vibration, rotation and translation) at a selected motion frequency in order to present several views of an individual grain of the sample. One or more measurements of diffraction, fluorescence, spectroscopic interaction, transmission, absorption and/or reflection can be made on the sample, using light in a selected wavelength region.

Sarrazin, Philippe C.↗

Picoliter droplet sample processing and deposition for mass spectrometry

Disclosed herein include systems, devices, and methods for droplet deposition for mass spectrometry. In some embodiments, a microfluidic device comprising wells is reversibly sealed to a mass spectrometry surface and used to deposit contents of droplets (e.g., enzymes and substrates), or products thereof, onto the mass spectrometry surface. The contents of droplets can be analyzed by laser desorption/ionization to, for example, identify a substrate of an enzyme or an enzyme capable of catalyzing a substrate to a product.

Ha, Noel↗

Miniature cyclotron resonance ion source using small permanent magnet

An ion source using the cyclotron resonance principle is described. A miniaturized ion source device is used in an air gap of a small permanent magnet with a substantially uniform field in the air gap of about 0.5 inch. The device and permanent magnet are placed in an enclosure which is maintained at a high vacuum (typically 10 to the minus 7th power) into which a sample gas can be introduced. The ion beam end of the device is placed very close to an aperture through which an ion beam can exit into the apparatus for an experiment.

Anicich, V. G.↗

A 600-MHz median-type digital filter on GaAs

A single-chip GaAs implementation of an FIR-median hybrid filter is presented. The very high-speed digital filter combines linear averaging structures to a median selector. The filter operates on 5-b samples with ECL-compatible I/O interfaces. The 1500-transistor LSI device with 3.6-sq mm chip size was processed with a 1.0-micron GaAs depletion-mode (D-mode) MESFET process. The filter demonstrates 600-MHz sample rate when operated in test mode utilizing special built-in feedback.

Vainjo, Olli↗

Nanomechanical testing of freestanding polymer films: in situ tensile testing and Tg measurement

Abstract A method for small-scale testing and imaging of freestanding, microtomed polymer films using a push-to-pull device is presented. Central to this method was the development of a sample preparation technique which utilized solvents at cryogenic temperatures to transfer and deposit delicate thin films onto the microfabricated push-to-pull devices. The preparation of focused ion beam (FIB)-milled tensile specimens enabled quantitative in situ TEM tensile testing, but artifacts associated with ion and electron beam irradiation motivated the development of a FIB-free specimen preparation method. The FIB-free method was enabled by the design and fabrication of oversized strain-locking push-to-pull devices. An adaptation for push-to-pull devices to be compatible with an instrumented nanoindenter expanded the testing capabilities to include in situ heating. These innovations provided quantitative mechanical testing, postmortem TEM imaging, and the ability to measure the glass transition temperature, via dynamic mechanical analysis, of freestanding polymer films. Results for each of these mentioned characterization methods are presented and discussed in terms of polymer nanomechanics. Graphic Abstract

36 MATERIALS SCIENCE↗

Polystyrene latex separations by continuous flow electrophoresis on the Space Shuttle

The seventh mission of the Space Shuttle carried two NASA experiments in the McDonnell Douglas Astronautics Corporation continuous flow electrophoresis system. The objectives were to test the operation of continuous flow electrophoresis in a reduced gravity environment using stable particles with established electrokinetic properties and specifically to evaluate the influence of the electrical properties of the sample constituents on the resolution of the continuous flow electrophoretic device. Polystrene latex microspheres dispersed in a solution with three times the electrical conductivity of the curtain buffer separated with a significantly larger band spread compared to the second experiment under matched conductivity conditions. It is proposed that the sample of higher electrical conductivity distorted the electric field near the sample stream so that the polystyrene latex particles migrated toward the chamber walls where electroosmosis retarded and spread the sample.

Snyder, R. S.↗

Summary of activities

Four space projects' activities are summarized. Design work on the Mars Penetrator Project, in cooperation with the NASA Ames Research Center, is being continued. Efforts are focused on the drilling mechanism which must penetrate the martian subsurface soil to collect and retrieve an uncontaminated sample. The new design consists of a rotary-percussive drill mechanism. This mechanism is optimum for dry drilling, necessary to avoid contamination of the soil sample, in many different soil types. The need for a small, relatively inexpensive device to study the chemical structure of this martian soil was also established. The egg design was chosen for its low cost compared to other systems and potential for a large number of eggs to be deployed on the martian surface. The design process included analysis of the dynamics of reentry, dissipation of heat during reentry, impact with the surface, access to undisturbed soil samples, and ability to gather samples from the soil at three depths. The egg consists of the reentry systems, soil probe lifting system, soil probe package, gas chromatograph, transmitter, and battery power supply. The egg must function only once, but is designed to withstand one martian year. The Mars Mole is designed as a rover-based device which penetrates the martian soil to a depth of up to 10 m, obtains a sample of soil, and returns it to the surface for analysis. The mole was designed to meet the following specifications: (1) weight less than 10 kg; (2) size less than 20 x 20 x 30 cm; (3) power less than 100 W; (4) ability to obtain a sample of at least 5 cc; (5) ability to penetrate fine, loose sand; and (6) need to obtain at least one sample. The space station umbilical connector project is a device which provides the translational motion of the connectors on the Space Station Freedom to allow engagement for power and data transfer. The design is capable of delivering a 20 lb force within the necessary tolerances and will operate reliably in the space environment.

Source record↗