Search NASA⌕ Search

SEARCH · Search NASA

Results for “Seat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Electric Vehicle Supply Equipment (EVSE) Site Assessment Report for the U.S. Army Corps of Engineers Chena Site Near Fairbanks, Alaska

This report presents an analysis of the requirements for charging station installation and electric vehicle operation at the US Army Corps of Engineers - Chena Site, located in a cold weather climate in the Fairbanks North Star Borough, AK. The report includes findings from a site visit, and a detailed electric vehicle (EV) charging site plan with cost estimates. Cost for three 50-ampere pedestal chargers located on the edge of the existing parking lot is estimated at $\$$53,100, and the cost of three 80-ampere chargers is estimated at $\$$89,400. The authors did not assess the cost of a heated garage. The USACE Chena site reaches extreme cold temperatures of -40 Degrees Celsius (-40 Degrees Fahrenheit) and below in a typical winter, often for days on end. Considerations of operating EVs as well as electrical vehicle supply equipment (EVSE) at this site can be applicable to other cold or extremely cold locations. Interviews with EV users in cold climates and a literature review indicated that EVs operate well but have significantly decreased range compared to 21 Degrees Celsius (70 Degrees Fahrenheit) operations. Some strategies such as prewarming the vehicle while it is plugged in and using heated seats and steering wheel instead of cabin heat, can improve cold weather performance. Storing the EV in a garage would mean the battery and cabin are automatically preheated, the battery would not age as rapidly as when the vehicle is stored outside, and problems with charging the vehicle are less likely. Lowest temperate-rated Electric Vehicle Supply Equipment (EVSE), as electric vehicle chargers are known as, are rated to -40 Degrees Celsius (-40 Degrees Fahrenheit), and sometimes malfunction. No EVSE is rated to the temperatures that USACE Chena site experienced for more than a week in winter 2023-4, of -50 Degrees Celsius (-45 Degrees Fahrenheit) and which are typical for the area. If reliability is a must, entities may want to consider a heated garage to minimize potential problems with charging equipment. There is a companion technical report to this titled "Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska" that examines the data on EV and EVSE cold-weather functionality in more detail. (Esparza, Truffer Moudra, and Hodge 2024).

33 ADVANCED PROPULSION SYSTEMS↗

The Impact of Operated Window Shading on Visual Comfort, Non-Visual Health, and Energy Demand from Electric Lighting

This paper introduces a simulation-based workflow to assess annual circadian lighting performance, glare risk and energy demand for an array of seated view positions under operated shading and electric lighting conditions. This workflow uses a combination of 9-band and 81-band simulations to represent daylight and electric lighting respectively. Annual daylight-driven calculations rely on a python-based code provided in the LARK simulation engine which was used to run 180-degree high dynamic range (HDR) renderings with 9-bands of spectral resolution. The results reveal the impact of shading systems on equivalent melanopic lux (EML) and daylight glare probability (DGP) over time and the energy demand (kWh) from electric lighting systems to supplement eye-level recommendations from the WELL v2 Building Standard.

Rockcastle, Siobhan↗

AI-Based Protein Interaction Screening and Identification (AISID)

In this study, we presented an AISID method extending AlphaFold-Multimer’s success in structure prediction towards identifying specific protein interactions with an optimized AISIDscore. The method was tested to identify the binding proteins in 18 human TNFSF (Tumor Necrosis Factor superfamily) members for each of 27 human TNFRSF (TNF receptor superfamily) members. For each TNFRSF member, we ranked the AISIDscore among the 18 TNFSF members. The correct pairing resulted in the highest AISIDscore for 13 out of 24 TNFRSF members which have known interactions with TNFSF members. Out of the 33 correct pairing between TNFSF and TNFRSF members, 28 pairs could be found in the top five (including 25 pairs in the top three) seats in the AISIDscore ranking. Surprisingly, the specific interactions between TNFSF10 (TNF-related apoptosis-inducing ligand, TRAIL) and its decoy receptors DcR1 and DcR2 gave the highest AISIDscore in the list, while the structures of DcR1 and DcR2 are unknown. The data strongly suggests that AlphaFold-Multimer might be a useful computational screening tool to find novel specific protein bindings. This AISID method may have broad applications in protein biochemistry, extending the application of AlphaFold far beyond structure predictions.

59 BASIC BIOLOGICAL SCIENCES↗

Microanalytical Approaches to Characterizing REE in Appalachian Basin Underclays

The search for a reliable U.S. domestic source of rare earth elements (REE) is necessary to support the demand of advanced energy applications (e.g., catalysts, electronics, magnets). Sedimentary deposits may be sources for selectively recovering REE and critical metals—specifically the interbedded seat rock, or underclay, that underlies or forms the floor of a coal seam. This material is often a major component of coal waste fines and refuse and thus readily available. This study examines several Appalachian Basin underclays associated with actively mined coal seams as potential feedstocks for the REE. Multimodal microanalytical electron microscopy (SEM, FIB-SEM, EMPA) synchrotron-based µXRF, and image processing techniques are coupled with detailed elemental and mineral data to classify the 2D and 3D petrophysical properties of the materials. The REE contents of Appalachian Basin underclays were measured from 235–399 ppm and predominantly observed as discrete REE-bearing minerals such as monazite and xenotime on the order of 10–100 µm in size. These REE-bearing minerals typically accounted for less than 1% of the scanned areas and volumes under SEM and FIB-SEM analysis, with the exception of regions enriched in crandallite. Synchrotron-based µXRF elemental maps further identified several REE deposition environments in different underclays, including micro-scale (10–100 µm) light REEs co-localizing with Ca and P, micro-scale heavy REEs with Fe, and large-scale light REEs (>200 µm) co-localizing with Sr, Ba, Ca and P.

36 MATERIALS SCIENCE↗

Constraining the Dynamo Layers in Jupiter and Saturn with Observations and Scaling Laws

The dipole-dominated magnetic fields of Jupiter and Saturn provide evidence for active dynamos operating within their deep interiors, yet the depth of the convecting dynamo layers remains poorly constrained. While magnetic field observations, gravity data, and interior models each provide partial insight, they have not been combined into a single, self-consistent picture of the internal structure. Here, we develop a framework that links observed magnetic field strength with intrinsic heat flux and gravity-constrained interior structure using energy-based dynamo scaling laws. By relating the axial magnetic field strength to the convective power, we infer the radial thickness of the dynamo-generating region for both Jupiter and Saturn. The constants of proportionality in the scaling relations are derived using independent constraints from Earth observations, Jupiter observations, and numerical dynamo simulations. Applied to Jupiter, this framework shows how the inferred dynamo layer thickness is coupled to the outer boundary of the dynamo region. Thinner dynamo layers are predicted when the outer boundary shifts to shallower depths, and no solutions are possible when the outer boundary is less than 73% of Jupiter’s radius. These results constrain plausible geometries for future numerical dynamo simulations. Extending the analysis to Saturn, we find a thick, deep-seated dynamo layer with an outer radius at 42% of the radius to be most plausible. An alternative solution with an inner radius of the dynamo region at 60% of the planetary radius, as suggested by ring seismology models, requires a very thin dynamo layer, occupying only 2%–3% of the total radius.

Geosciences↗

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗

HUMAN CONTROL PERFORMANCE AND TOLERANCE UNDER SEVERE COMPLEX WAVE FORM VIBRATION, WITH A PRELIMINARY HISTORICAL REVIEW OF FLIGHT SIMULATION

What can we do, preparing for these pioneers, to insure that these expected vibrations will not jeopardize their lives nor their missions? This paper will describe one approach, of attempting to simulate the expected and more than the expected complex wave form vibrations to determine tolerance and pilot control capabilities, to attempt to find solutions in simulation before the first flights in reality. The experimental work to be described was done in November, 1959, and June, 1960, on the Johnsville Navy human centrifuge, at the Aviation Medical Acceleration Laboratory, U.S. Naval Air Development Center, Johnsville, Pennsylvania, and in June, 1960, on the North American "G-seat", the vertical accelerator of the North American Aviation Co., Inc., Columbus, Ohio, while the author was Jostle Program Officer at the Aviation Medical Acceleration Laboratory. The experimental work was the subject of the confidential reports NADC-MA-L6005 and NADC-MA-6128, U.S. Naval Air Development Center, and NA60H-444, North American Aviation, Inc., Columbus. Unclassified aspects can now be reported.

Vibration↗

ADVANCED VALVE TECHNOLOGY FOR SPACECRAFT ENGINES FINAL REPORT

This final report describes the work that was done to determine the state-of-the-art of valves required for space exploration vehicles and the steps that were taken to advance the technology. Interviews were held with personnel of major prime manufacturers to determine current problems and current and future requirements. Manufacturers were surveyed by mail to determine what equipment is presently being produced. An extensive search of patent office files was made to determine if any novel valve concepts not already applied to aerospace valves might exist. A literature search was conducted to provide the necessary technical information that was required for the program. Several extensive studies were made to determine the effects on materials resulting from use in space applications, and an investigation of the basic phenomena of valve seat wear was initiated. With the information developed in the surveys and studies, the significant problems associated with valves were identified and are described under "Discussion of Problems. " A novel valve concept was developed and a prototype valve was built and successfully tested. A seal compound of Teflon and stainless steel was developed which possesses superior cold flow characteristics while retaining the desirable properties of the basic Teflon material.

Spacecraft propulsion↗

Removable well in reaction flask facilitates carbon dioxide collection

Removable plastic well with a flange that seats on the rim of an Erlenmeyer screwcap flask aids quantitative collection of carbon dioxide liberated in the flask. The well can be removed without danger of cross-contamination. It can collect other gases using appropriate absorbents.

Source record↗

Pressure responsive seal handles static and dynamic loads

Ported ball valves are sealed under both static and dynamic load conditions by a line-pressure responsive double-acting seal. The top of the seal engages the ported ball at the outer circumferential edge of the seal upper end, and the bottom of the seal seats on a flat circular land with a continuous wall.

Marsh, H. W.↗

Strainer fits inside flared-tube fittings

Cylindrical wire-mesh strainer which fits inside flare-tube fittings is readily installed and easily replaced. It has a collar that seats on the tapered shoulder of the male fitting.

Parker, O. J.↗

Ring valve responds to differential pressure changes

Pressure valve has a moving annular ring seal that automatically reacts to differential pressure changes across the seat. This valve has good potential for the petroleum and chemical industries.

Source record↗

Shock-operated valve would automatically protect fluid systems

Glandless valve shuts down high-pressure fluid systems when severe shock from an explosion or earthquake occurs. The valve uses a pendulum to support the valve closure plug in the open position. When jarred, the valve body is moved relative to the pendulum and the plug support is displaced, allowing the plug to seat and be held by spring pressure.

Branum, L. W.↗

Advanced valve technology for spacecraft.

Valve technology for spacecraft and rocket engine applications, discussing zero-gravity vent valve, zero leakage valve, insensitive valve seat and solenoid actuator

CONTROL VALVE↗

Dual rate pressure relief valve

Pressure relief valve vents at a slow bleed rate at one pressure level and at a higher bleed rate at a higher pressure level. The value housing contains a sleeve, inlet port, outlet port, an orifice, a ball and seat arrangement, and a belleville spring diaphragm.

Steeneken, J.↗

Tool repairs tube components in situ

Two versions of a portable tool repair the seats of tube fittings and the flared ends of tubing. Each version operates on the principle of lapping to remove imperfections from tube and fitting interfacing surfaces.

Rush, R. E.↗

Two-functional seal for hose connection

Seal, machined from a plastic material, prevents liquid hydrogen leakage from hose connectors. It serves as a block-type seal supporting maximum loading of the poppet with slight elastic deflection or as a lip-type seal that is deformed elastically in bending, tension, or compression by the seated poppet.

Richardson, M. B.↗