Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

X-ray and γ-ray beam interstellar communication and implications for SETI

The possibility of detecting artificial signals transmitted by alien civilizations via collimated X-ray or gamma-ray beams is investigated. The prospect of using such beams for human communication within the solar system and beyond is also discussed. Detector responses were simulated for input signals and analyzed using relative entropy. For simplicity, all signals were assumed to use on-off keying (OOK) modulation. “Real” signals were generated by taking digital files and sequentially feeding their raw binary data to the detector simulator, the resulting normalized information content of the detector signals was plotted and compared to random noise signals. Since jpeg files contain compressed information, these served as a proxy for artificial alien signals. This showed that there is a clear difference in measured information content between natural and artificial signals, even with relatively poor time resolution in the detector causing the signals to be smeared (dead-time/rise-time intervals many times longer than the duration between signal pulses). It was found that so long as the signal lasts for at least several rise-time/dead-time intervals, the distinction between random and artificial signals is obvious. A space-telescope with high time resolution for searching for such signals is briefly described and its basic requirements are outlined.

43 PARTICLE ACCELERATORS↗

Resonant X-ray Sum-Frequency-Generation Spectroscopy of K-edges in Acetyl Fluoride

Resonant X-ray sum-frequency generation is calculated for excitations of the fluorine and oxygen core K-edge electrons in acetyl fluoride using real-time time-dependent density functional theory. The signal is generated by an extreme-ultraviolet followed by an Xray pulse with variable delay T. The X-ray pulse is tuned to different element-specific core excitations and used to probe the dynamics of a valence electronic wavepacket. A twodimensional signal is recorded as a function of the dispersed X-ray pulse frequency and the frequency conjugated to T, revealing the couplings between core and valence excited states. Molecular orbital decomposition of the signal shows which regions of the molecule contribute to the X-ray excitation.

Bruner, Adam S.↗

POINT: Partially Observable Imitation Network for Traffic Signal Control

Smart traffic signals bring together transportation infrastructure and advance technologies to improve the mobility and efficiency of urban transportation network. Adaptive traffic signal control studies can be categorized into modeling-based approaches and learning-based approaches. In order to take advantages of these two systems, this study developed an offline-online combined Partial Observable Imitation Network for Traffic signal control (POINT). In the offline system, the traffic signal timing optimization problem was formulated as a Mixed Integer Nonlinear Programming (MINLP) given complete traffic information, i.e., second-by-second speeds and locations of all vehicles. Furthermore, the objective of MINLP is to minimize total travel delays considering individual vehicle trajectories under Connected Vehicle (CV) environment. The calculated optimal solutions under various traffic conditions were considered as the ”expert” decisions. In the online system, an imitation neural network model was developed to learn the ”expert” signal plans generated from offline system. Given partial observable traffic conditions in real time, e.g., the aggregate-level of traffic volume, the POINT model can compute the signal timing parameters in the online system. The numerical results demonstrated that the proposed method outperformed other state-of-the-art signal control method under high and unbalanced traffic demand levels in terms of reducing travel delays and queue length.

33 ADVANCED PROPULSION SYSTEMS↗

Redox conditions correlated with vibronic coupling modulate quantum beats in photosynthetic pigment–protein complexes

Significance Photosynthetic organisms evolved their light-harvesting antenna complexes to optimize energy transfer. It was recently shown that the redox environment can tune the mixing of electronic and vibrational states to steer energy through different pathways of a pigment–protein complex. Quantum beating signals in the spectra of pigment–protein complexes have been used to probe the excited-state dynamics within the complexes, but the microscopic dynamics that generate these signals and their role in promoting energy transfer are not fully understood. Here, we show that the redox environment that tunes energy transfer similarly tunes the quantum beating signals in the same complex. We find that the beats report on excited-state vibrations that maintain coherence through the vibronically enhanced energy transfer process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic Monitoring of the Ion-Plasma Treatment of Complex Components

Low-temperature ion-plasma treatment of metal workpieces may be monitored in terms of the electrical signals recorded in the circuit consisting of the plasma, the workpiece, the clamp, and ground. The electrical signals are analyzed by means of the Hurst statistic H, which provides a basic quantitative picture of the formation and modification of the signal structure in the course of machining. Experiments show that the best results (a surface layer of maximum hardness) are obtained when machining is accompanied by the generation of signals for which the Hurst statistic indicates antipersistent behavior.

42 ENGINEERING↗

Generating Uncertainty Distributions for Seismic Signal Onset Times

Signal arrival-time estimation plays a critical role in a variety of downstream seismic analyses, including location estimation and source characterization. Any arrival-time errors propagate through subsequent data-processing results. In this article, we detail a general framework for refining estimated seismic signal arrival times along with full estimation of their associated uncertainty. Using the standard short-term average/long-term average threshold algorithm to identify a search window, we demonstrate how to refine the pick estimate through two different approaches. In both cases, new waveform realizations are generated through bootstrap algorithms to produce full a posteriori estimates of uncertainty of onset arrival time of the seismic signal. The onset arrival uncertainty estimates provide additional data-derived information from the signal and have the potential to influence seismic analysis along several fronts.

58 GEOSCIENCES↗

Molecular mechanisms of 3,3′4,4′,5-pentachlorobiphenyl-induced epithelial-mesenchymal transition in human hepatocellular carcinoma cells

Polychlorinated biphenyls (PCBs) are classic persistent organic pollutants (POPs). Many studies have found a positive association between the progression of hepatocellular carcinoma (HCC) and PCBs exposure. However, the influence of PCBs on epithelial-mesenchymal transition (EMT) of HCC remains to be unclear. In this study, we explored the effect of PCB126 on EMT in HCC cells and its underlying mechanisms. The data showed that PCB126, exposing both Bel-7402 and SMMC-7721 cells for 48 h, promoted EMT that was demonstrated by E-cadherin repression, up-regulation of N-cadherin and vimentin, and morphological alteration. We found that signal transducer and activator of transcription 3 (STAT3)/Snail1 signaling was activated after PCB126 exposure, and the addition of STAT3 inhibitor WP1066 blocked PCB126-induced down-regulation of E-cadherin as well as up-regulation of N-cadherin and vimentin. Moreover, PCB126 exposure increased pyruvate kinase M2 (PKM2) expression and its nuclear translocation, whereas treatment with PKM2 shRNA suppressed the activation of STAT3/Snail1 signaling and the alternation of EMT-related molecules (E-cadherin, N-cadherin and vimentin). Furthermore, this study indicated estrogen receptor (ER) and aryl hydrocarbon receptor (AhR) were involved in PCB126-induced effects on PKM2, STAT3/Snail1 signaling and EMT by according treatment using ER inhibitor ICI and AhR shRNA. Notably, PCB126-increased reactive oxygen species (ROS) production via AhR is associated with activation of PKM2/STAT3/Snail1 cascades and contributes to EMT. Taken together, these results indicated that PCB126 promotes EMT process of HCC cells via PKM2/STAT3/Snail1 signaling which is mediated by ER and AhR. - Highlights: • PCB126 promotes epithelial-mesenchymal transition of HCC cells. • PCB126 regulates EMT through the activation of STAT3/Snail1 signaling. • PKM2 is responsible for PCB126-induced activation of STAT3/Snail1 signaling. • AhR-induced ROS generation regulates PKM2/STAT3/Snail1 signaling. • PCB126-induced EMT is mediated by ER and AhR.

60 APPLIED LIFE SCIENCES↗

Control and optimization system and method for chemical looping processes

A control system for optimizing a chemical loop system includes one or more sensors for measuring one or more parameters in a chemical loop. The sensors are disposed on or in a conduit positioned in the chemical loop. The sensors generate one or more data signals representative of an amount of solids in the conduit. The control system includes a data acquisition system in communication with the sensors and a controller in communication with the data acquisition system. The data acquisition system receives the data signals and the controller generates the control signals. The controller is in communication with one or more valves positioned in the chemical loop. The valves are configured to regulate a flow of the solids through the chemical loop.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Control and optimization system and method for chemical looping processes

A control system for optimizing a chemical loop system includes one or more sensors for measuring one or more parameters in a chemical loop. The sensors are disposed on or in a conduit positioned in the chemical loop. The sensors generate one or more data signals representative of an amount of solids in the conduit. The control system includes a data acquisition system in communication with the sensors and a controller in communication with the data acquisition system. The data acquisition system receives the data signals and the controller generates the control signals. The controller is in communication with one or more valves positioned in the chemical loop. The valves are configured to regulate a flow of the solids through the chemical loop.

47 OTHER INSTRUMENTATION↗

Multiscale spectral nanoscopy

A system and method for non-invasively tracking a particle in a sample is disclosed. The system includes a 2-photon or confocal laser scanning microscope (LSM) and a particle-holding device coupled to a stage with X-Y and Z position control. The system also includes a tracking module having a tracking excitation laser, X-Y and Z radiation-gathering components configured to detect deviations of the particle in an X-Y and Z directions. The system also includes a processor coupled to the X-Y and Z radiation gathering components, generate control signals configured to drive the stage X-Y and Z position controls to track the movement of the particle. The system may also include a synchronization module configured to generate LSM pixels stamped with stage position and a processing module configured to generate a 3D image showing the 3D trajectory of a particle using the LSM pixels stamped with stage position.

42 ENGINEERING↗

Design and Testing of the Address in Real-Time Data Driver Card for the Micromegas Detector of the ATLAS New Small Wheel Upgrade

The Address in Real Time Data Driver Card (ADDC) is designed to transmit the trigger data in the Micro-Mesh Gaseous Structure (Micromegas) detector of the ATLAS New Small Wheel (NSW) upgrade. The Address in Real Time (ART) signals are generated by the front-end ASIC, named VMM chip, to indicate the address of the first above-threshold event. A custom ASIC (ART ASIC) is designed to receive the ART signals from the VMM chip and implement the hit-selection. The processed data from the ART ASIC will be transmitted out of the NSW through the GBTx serializer, the unidirectional Versatile Twin Transmitter (VTTx) and fiber optical links. The ART signal is critical for the ATLAS experiment trigger selection thus the performance and stability of the ADDC is very important. To ensure extensive testing of the ADDC, an FPGA Mezzanine Card (FMC) based testing platform and a special designed firmware/software are developed. We find that this test platform works with the commercial Xilinx VC707 FPGA development kit, independent of the other electronics of the NSW it can test all the functions of the ADDC and its long-term stability. This paper will introduce the design, testing procedure and results of the ADDC and the FMC testing platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improving ICARUS Track Reconstruction Algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino (SBN) program at Fermilab. The main goal of the experiment is to investigate the possibility of sterile neutrinos in the O(1 eV) mass region and provide clarification of the anomaly detected from the Liquid Scintillator Neutrino Detector (LSND) and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber (LAr-TPC), that can provide excellent 3D imaging and calorimetric reconstruction of any ionizing particles. This detection technique allows a detailed study of neutrino interactions, spanning a wide energy spectrum (from a few keV to several hundreds of GeV). The detector consists of two identical adjacent modules, filled with a total of 760 tons of ultra-pure liquid argon. Each module houses two LAr-TPCs separated by a common cathode with a maximum drift distance of 1.5 m, equivalent to about 1 ms drift time for the nominal $500$ V/m electric drift field. The anode is made of three parallel wire planes positioned 3 mm apart, where the stainless-steel wires are oriented on each plane at a different angle with respect to the horizontal direction ($+60^\degree$,$-60^\degree$,$0^\degree$). The first two planes (Induction 1 and Induction 2) provide a non-destructive charge measurement, whereas the ionization charge is fully collected by the last collection plane. In total, 53248 wires with a 3 mm pitch and length up to 9 m are installed in the detector. In the first stage of the reconstruction, segments of waveforms corresponding to physical signals (hits) are searched for in the deconvolved wire waveform with a threshold-based hit-finding algorithm. Each hit is then fitted with a Gaussian, whose area is proportional to the number of drift electrons generating the signal. In the second stage of the reconstruction, hits are passed as input to Pandora, a framework software composed of different pattern recognition algorithms, that performs a 3D reconstruction of the full image recorded in the collected event, including the identification of interaction vertices and tracks and showers inside the TPC. These are organized into a hierarchical structure (called slice) of particles generated starting from a primary interaction vertex. In some cases, related to the inefficiencies in the hit detection or excessive deflection of the particle trajectory, Pandora breaks the particle's track into two or more smaller pieces and considers each piece as an independent track. We studied this phenomenon focusing on primary muons from ν_μ CC interactions contained in a single module with a track at least 20 cm long, to exclude delta rays. The study determined that about $7-8\%$ of the muon tracks are broken. Approximately $80\%$ of the times, Pandora assigns all segments of the track to the same slice (intra-slice track split), while in the remaining $20\%$ of the cases, one of the segments is associated with another slice (extra-slice track split). To mitigate this phenomenon, we designed an algorithm that detects and stitches the tracks broken by Pandora for the intra-slice split. In Monte Carlo simulations, the algorithm showed an efficiency exceeding $80\%$ and a purity exceeding $93\%$.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Large Area Picosecond Photodetector (LAPPD TM ) - Pilot production and development status

Here, we discuss performance results achieved for fully functional sealed Large Area Picosecond Photodetectors (LAPPD (TM)) in tests performed at Incom Inc., as well as independent test results reported by our early adopters. The LAPPD is a microchannel plate (MCP) based large area picosecond photodetector, capable of imaging with single-photon sensitivity at high spatial and temporal resolutions in a hermetic package. The LAPPD has an active area of 350 square centimeters in an all-glass hermetic package with a fused silica window and bottom plate and sidewalls made of borosilicate float glass. Signals are generated by a bi-alkali Na 2 KSb photocathode and amplified with a stacked chevron pair of MCPs produced by applying resistive and emissive atomic layer deposition coatings to glass capillary array (GCA) substrates. Signals are collected on RF stripline anodes applied to the bottom plates which exit the detector via pin-free hermetic seals under the side walls. LAPPD test and performance results for product produced and delivered to early adopter customers during the first half of 2018 are reviewed. These results include electron gains ≥ 7.5 x 10 6 @ 850/950 V (entry/exit MCP), low dark noise rates (22 Cts/s/cm 2 ), single photoelectron (PE) timing resolution of 64 picoseconds RMS, and single photoelectron spatial resolution along and across strips of 2.8 mm and 1.3 mm RMS respectively. Many of these devices also had very high QE photocathodes that were uniform over the full 195 mm x 195 mm window active area (LAPPD #15 QE% @ 365 nm Max/Avg/Min = 25.8/22.3 ± 3/15.7). An update is additionally provided of developments that enable capacitive signal coupling from the detector to application specific pads or stripline readout patterns deployed on printed circuit boards positioned beneath the file, outside of the vacuum package. We conclude with examples of how sensors offering picosecond timing, in diverse applications can bring transformative change to detector technology and applications in future experiments.

47 OTHER INSTRUMENTATION↗

THE SPECTRAL-TIMING PROPERTIES OF UPPER AND LOWER kHz QPOs

Soft lags from the emission of the lower kilohertz quasi-periodic oscillations (kHz QPOs) of neutron star low-mass X-ray binaries have been reported from 4U1608-522 and 4U1636-536. Those lags hold prospects for constraining the origin of the QPO emission. In this paper, we investigate the spectral-timing properties of both the lower and upper kHz QPOs from the neutron star binary 4U1728-34, using the entire Rossi X-Ray Timing Explorer archive on this source. We show that the lag-energy spectra of the two QPOs are systematically different: while the lower kHz QPO shows soft lags, the upper kHz QPO shows either a flat lag-energy spectrum or hard variations lagging softer variations. This suggests two different QPO-generation mechanisms. We also performed the first spectral deconvolution of the covariance spectra of both kHz QPOs. The QPO spectra are consistent with Comptonized blackbody emission, similar to the one found in the time-averaged spectrum, but with a higher seed-photon temperature, suggesting that a more compact inner region of the Comptonization layer (boundary/spreading layer, corona) is responsible for the QPO emission. Considering our results together with other recent findings, this leads us to the hypothesis that the lower kHz QPO signal is generated by coherent oscillations of the compact boundary layer region itself. The upper kHz QPO signal may then be linked to less-coherent accretion-rate variations produced in the inner accretion disk, and is then detected when they reach the boundary layer.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing Magnetite Nanoparticles for Mass Sensitivity in Magnetic Particle Imaging

Purpose: Magnetic particle imaging (MPI), using magnetite nanoparticles (MNPs) as tracer material, shows great promise as a platform for fast tomographic imaging. To date, the magnetic properties of MNPs used in imaging have not been optimized. As nanoparticle magnetism shows strong size dependence, we explore how varying MNP size impacts imaging performance in order to determine optimal MNP characteristics for MPI at any driving field frequency f 0 . Methods: Monodisperse MNPs of varying size were synthesized and their magnetic properties characterized. Their MPI response was measured experimentally, at an arbitrarily chosen f 0 = 250 kHz, using a custom-built MPI transceiver designed to detect the third harmonic of MNP magnetization. Results were interpreted using a model of dynamic MNP magnetization that is based on the Langevin theory of superparamagnetism and accounts for sample size distribution, and size-dependent magnetic relaxation. Results: Our experimental results show clear variation in the MPI signal intensity as a function of MNP size that is in good agreement with modeled results. A maxima in the plot of MPI signal vs. MNP size indicates there is a particular size that is optimal for the chosen frequency of 250 kHz. Conclusions: For MPI at any chosen frequency, there will exist a characteristic particle size that generates maximum signal amplitude. We illustrate this at 250 kHz with particles of 15 nm core diameter.

36 MATERIALS SCIENCE↗

TRUST Nonlinear Dynamics Testbed Assessment

The following assessment evaluates the efficacy of the control script for carrying out a linear signal to generate a linear mechanical response of the system: the TRUST nonlinear dynamics (TRUSTND) testbed. The hardware has three main components: the controller (NI PXIe 8861) embedded in the National Instruments chassis (NI PXIe 1092), the signal amplifier (The Modal Shop Linear Power Amplifier 2050E09) to amplify the output of a custom LabVIEW script, and a shaker (The Modal Shop Electrodynamic Exciter 2075E) where wave spring specimens live and are tested within the attached aluminum testbed (center mass). Different kinds of signals (single-tone, swept frequency and white noise) were sent through this hardware in the E-1 lab space at TA-53. First, the linearity of the setup was tested by specifying a sine wave in the control script and checking the quality of the oscillations in a wave spring (McMaster-Carr 9714K19 [1]). When passing a sine wave through the amplifier was succeeded, the frequency response of the wave spring was tested with white noise for comparison to finite-element model predictions. The testbed outputs a repeatable, linear response to the input excitation when used with the wave spring. These measurements reduce the uncertainty associated with the testbed and test procedure to better characterize uncertainty associated with material behavior (SX358 foam samples) in future tests

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Failure detection in high-performance clusters and computers using chaotic map computations

A programmable media includes a processing unit capable of independent operation in a machine that is capable of executing 10.sup.18 floating point operations per second. The processing unit is in communication with a memory element and an interconnect that couples computing nodes. The programmable media includes a logical unit configured to execute arithmetic functions, comparative functions, and/or logical functions. The processing unit is configured to detect computing component failures, memory element failures and/or interconnect failures by executing programming threads that generate one or more chaotic map trajectories. The central processing unit or graphical processing unit is configured to detect a computing component failure, memory element failure and/or an interconnect failure through an automated comparison of signal trajectories generated by the chaotic maps.

97 MATHEMATICS AND COMPUTING↗

Comments on Zihang Zhu, Shanghong Zhao, Xuan Li, and Kun Qu, Tao Lin, “Photonic generation of frequency-octupled microwave signal with reduced electrical local oscillator power and improved spectrum purity” Opt. Quant. Electron (2017)

In the title paper, Zhu et al. presented a technique for generating filter less frequency octo-tupling signal based on a cascade of two dual-polarization modulators. Firstly, the harmonics of order 4l (l in an integer) are generated in the x-polarization by driving the x-modulators with an RF signal with a 90° phase difference between the two stages. Then the carrier is suppressed using unmodulated y-polarization by means of polarization multiplexing. Accordingly, the demerit of their design is the requirement to reset a precise polarizer angle to suppress the optical carrier every time there is a change in the RF drive amplitude or the modulation index. Nevertheless, the authors claim superior performance to a similar architecture in which the y-branch is modulated with the proper RF drive phases to suppress the carrier for all drive levels with no need to adjust a splitting ratio. The aim of this comment is to show that by modulating the y-polarization with adjusted RF drive phases, same architecture can be used to perform frequency octo-tupling whose performance is neither limited by precise settings of the polarizer angle nor by the proper settings of the modulation index. The carrier is suppressed for a unique value of the polarizer angle for all modulation index. If the modulation index is adjusted to suppress the 4th harmonics, same circuit can be used to perform frequency 24-tupling generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗