At least 505 records · Page 28

Combinatorial DNA Damage Pairing Model Based on X-Ray-Induced Foci Predicts the Dose and LET Dependence of Cell Death in Human Breast Cells

In contrast to the classic view of static DNA double-strand breaks (DSBs) being repaired at the site of damage, we hypothesize that DSBs move and merge with each other over large distances (m). As X-ray dose increases, the probability of having DSB clusters increases as does the probability of misrepair and cell death. Experimental work characterizing the X-ray dose dependence of radiation-induced foci (RIF) in nonmalignant human mammary epithelial cells (MCF10A) is used here to validate a DSB clustering model. We then use the principles of the local effect model (LEM) to predict the yield of DSBs at the submicron level. Two mechanisms for DSB clustering, namely random coalescence of DSBs versus active movement of DSBs into repair domains are compared and tested. Simulations that best predicted both RIF dose dependence and cell survival after X-ray irradiation favored the repair domain hypothesis, suggesting the nucleus is divided into an array of regularly spaced repair domains of ~;;1.55 m sides. Applying the same approach to high-linear energy transfer (LET) ion tracks, we are able to predict experimental RIF/m along tracks with an overall relative error of 12percent, for LET ranging between 30 350 keV/m and for three different ions. Finally, cell death was predicted by assuming an exponential dependence on the total number of DSBs and of all possible combinations of paired DSBs within each simulated RIF. Relative biological effectiveness (RBE) predictions for cell survival of MCF10A exposed to high-LET showed an LET dependence that matches previous experimental results for similar cell types. Overall, this work suggests that microdosimetric properties of ion tracks at the submicron level are sufficient to explain both RIF data and survival curves for any LET, similarly to the LEM assumption. Conversely, high-LET death mechanism does not have to infer linear-quadratic dose formalism as done in the LEM. In addition, the size of repair domains derived in our model are based on experimental RIF and are three times larger than the hypothetical LEM voxel used to fit survival curves. Our model is therefore an alternative to previous approaches that provides a testable biological mechanism (i.e., RIF). In addition, we propose that DSB pairing will help develop more accurate alternatives to the linear cancer risk model (LNT) currently used for regulating exposure to very low levels of ionizing radiation.

59 BASIC BIOLOGICAL SCIENCES↗

Dispersion of Radionuclides and Exposure Assessment in Urban Environments: A Joint CEA and LLNL Report

In the interest of promoting the international exchange of technical expertise, the US Department of Energy’s Office of Emergency Operations (NA-40) and the French Commissariat à l'Energie Atomique et aux énergies alternatives (CEA) requested that the National Atmospheric Release Advisory Center (NARAC) of Lawrence Livermore National Laboratory (LLNL) in Livermore, California host a joint table top exercise with experts in emergency management and atmospheric transport modeling. In this table top exercise, LLNL and CEA compared each other’s flow and dispersion models. The goal of the comparison is to facilitate the exchange of knowledge, capabilities, and practices, and to demonstrate the utility of modeling dispersal at different levels of computational fidelity. Two modeling approaches were examined, a regional scale modeling approach, appropriate for simple terrain and/or very large releases, and an urban scale modeling approach, appropriate for small releases in a city environment. This report is a summary of LLNL and CEA modeling efforts from this exercise. Two different types of LLNL and CEA models were employed in the analysis: urban-scale models (Aeolus CFD at LLNL/NARAC and Parallel- Micro-SWIFT-SPRAY, PMSS, at CEA) for analysis of a 5,000 Ci radiological release and Lagrangian Particle Dispersion Models (LODI at LLNL/NARAC and PSPRAY at CEA) for analysis of a much larger (500,000 Ci) regional radiological release. Two densely-populated urban locations were chosen: Chicago with its high-rise skyline and gridded street network and Paris with its more consistent, lower building height and complex unaligned street network. Each location was considered under early summer daytime and nighttime conditions. Different levels of fidelity were chosen for each scale: (1) lower fidelity mass-consistent diagnostic, intermediate fidelity Navier-Stokes RANS models, and higher fidelity Navier-Stokes LES for urban-scale analysis, and (2) lower-fidelity single-profile meteorology versus higher-fidelity three-dimensional gridded weather forecast for regional-scale analysis. Tradeoffs between computation time and the fidelity of the results are discussed for both scales. LES, for example, requires nearly 100 times more processor time than the mass-consistent diagnostic model or the RANS model, and seems better able to capture flow entrainment behind tall buildings. As anticipated, results obtained by LLNL and CEA at regional scale around Chicago and Paris look very similar in terms of both atmospheric dispersion of the radiological release and total effective dose. Both LLNL and CEA used the same meteorological data, Lagrangian particle dispersion models, and the same dose coefficients. LLNL and CEA urban-scale modeling results show consistent phenomenological behavior and predict similar impacted areas even though the detailed 3D flow patterns differ, particularly for the Chicago cases where differences in vertical entrainment behind tall buildings are particularly notable. Although RANS and LES (LLNL) models incorporate more detailed physics than do mass-consistent diagnostic flow models (CEA), it is not possible to reach definite conclusions about the prediction fidelity of the various models as experimental measurements were not available for comparison. Stronger conclusions about the relative performances of the models involved and evaluation of the tradeoffs involved in model simplification could be made with a systematic benchmarking of urban-scale modeling. This could be the purpose of a future US / French collaborative exercise.

54 ENVIRONMENTAL SCIENCES↗

Measurement and modeling of the effect of support arm backscatter on dosimetry with a Varian EPID

Purpose: Amorphous silicon EPIDs have been used for planar dose verification in IMRT treatments for many years. The support arm used to attach some types of EPIDs to linear accelerators can introduce inaccuracies to dosimetry measurements due to the presence of metallic parts in their structures. It is demonstrated that this uncertainty may be as large as {approx}6% of maximum image signal for large fields. In this study, a method has been described to quantify, model and correct for the effect of backscattered radiation from the EPID support arm (E-Arm type, Varian Medical Systems). Methods: Measurements of a support arm backscatter kernel were made using several 1x1 cm{sup 2} 6 MV pencil beam irradiations at a sample of positions over the sensitive area of the EPID in standard clinical setup and repeated with the EPID removed from the support arm but at the same positions. A curve-fit to the subtraction of EPID response obtained on and off the arm was used to define the backscatter kernel. The measured kernel was compared with a backscatter kernel obtained by Monte Carlo simulations with EGS/BEAM code. A backscatter dose prediction using the measured backscatter kernel was added to an existing EPID dose prediction model. The improvement in the agreement of the modified model predictions with EPID measurements for a number of open fields and IMRT beams were investigated by comparison to the original model results. Results: Considering all functions tested to find the best functional fit to the data points, a broad Gaussian curve proved to be the optimum fit to the backscatter data. The best fit through the Monte Carlo simulated backscatter kernel was also found to be a Gaussian curve. The maximum decrease in normalized root mean squared deviation of the measured and modeled EPID image profiles for open fields was 13.7% for a 15x15 cm{sup 2} field with no decrease observed for a 3x3 cm{sup 2} (the smallest) field as it was not affected by the arm backscatter. Gamma evaluation (2%, 2 mm criteria) showed the improvement in agreement between the model and measurement results when the backscatter was incorporated. The average increase in Gamma pass rate was 2% for head and neck and 1.3% for prostate IMRT fields investigated in this study. Conclusions: The application of the backscatter kernel determined in this study improved the accuracy of dosimetry using a Varian EPID with E-arm for open fields of different sizes: Eight head and neck and seven prostate IMRT fields. Further improvement in the agreement between the model predictions and EPID measurements requires more sophisticated modeling of the backscatter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal ''image-based'' weighting for energy-resolved CT

This paper investigates a method of reconstructing images from energy-resolved CT data with negligible beam-hardening artifacts and improved contrast-to-nosie ratio (CNR) compared to conventional energy-weighting methods. Conceptually, the investigated method first reconstructs separate images from each energy bin. The final image is a linear combination of the energy-bin images, with the weights chosen to maximize the CNR in the final image. The optimal weight of a particular energy-bin image is derived to be proportional to the contrast-to-noise-variance ratio in that image. The investigated weighting method is referred to as ''image-based'' weighting, although, as will be described, the weights can be calculated and the energy-bin data combined prior to reconstruction. The performance of optimal image-based energy weighting with respect to CNR and beam-hardening artifacts was investigated through simulations and compared to that of energy integrating, photon counting, and previously studied optimal ''projection-based'' energy weighting. Two acquisitions were simulated: dedicated breast CT and a conventional thorax scan. The energy-resolving detector was simulated with five energy bins. Four methods of estimating the optimal weights were investigated, including task-specific and task-independent methods and methods that require a single reconstruction versus multiple reconstructions. Results demonstrated that optimal image-based weighting improved the CNR compared to energy-integrating weighting by factors of 1.15-1.6 depending on the task. Compared to photon-counting weighting, the CNR improvement ranged from 1.0 to 1.3. The CNR improvement factors were comparable to those of projection-based optimal energy weighting. The beam-hardening cupping artifact increased from 5.2% for energy-integrating weighting to 12.8% for optimal projection-based weighting, while optimal image-based weighting reduced the cupping to 0.6%. Overall, optimal image-based energy weighting provides images with negligible beam-hardening artifacts and improved CNR compared to energy-integrating and photon-counting methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic cone beam CT angiography of carotid and cerebral arteries using canine model

Purpose: This research is designed to develop and evaluate a flat-panel detector-based dynamic cone beam CT system for dynamic angiography imaging, which is able to provide both dynamic functional information and dynamic anatomic information from one multirevolution cone beam CT scan. Methods: A dynamic cone beam CT scan acquired projections over four revolutions within a time window of 40 s after contrast agent injection through a femoral vein to cover the entire wash-in and wash-out phases. A dynamic cone beam CT reconstruction algorithm was utilized and a novel recovery method was developed to correct the time-enhancement curve of contrast flow. From the same data set, both projection-based subtraction and reconstruction-based subtraction approaches were utilized and compared to remove the background tissues and visualize the 3D vascular structure to provide the dynamic anatomic information. Results: Through computer simulations, the new recovery algorithm for dynamic time-enhancement curves was optimized and showed excellent accuracy to recover the actual contrast flow. Canine model experiments also indicated that the recovered time-enhancement curves from dynamic cone beam CT imaging agreed well with that of an IV-digital subtraction angiography (DSA) study. The dynamic vascular structures reconstructed using both projection-based subtraction and reconstruction-based subtraction were almost identical as the differences between them were comparable to the background noise level. At the enhancement peak, all the major carotid and cerebral arteries and the Circle of Willis could be clearly observed. Conclusions: The proposed dynamic cone beam CT approach can accurately recover the actual contrast flow, and dynamic anatomic imaging can be obtained with high isotropic 3D resolution. This approach is promising for diagnosis and treatment planning of vascular diseases and strokes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-QI-11: Measurement of Renal Pyruvate-To-Lactate Exchange with Hyperpolarized 13C MRI

Purpose: Previous work [1] modeling the metabolic flux between hyperpolarized [1-13C]pyruvate and [1-13C]lactate in magnetic resonance spectroscopic imaging (MRSI) experiments failed to account for vascular signal artifacts. Here, we investigate a method to minimize the vascular signal and its impact on the fidelity of metabolic modeling. Methods: MRSI was simulated for renal metabolism in MATLAB both with and without bipolar gradients. The resulting data were fit to a two-site exchange model [1], and the effects of vascular partial volume artifacts on kinetic modeling were assessed. Bipolar gradients were then incorporated into a gradient echo sequence to validate the simulations experimentally. The degree of diffusion weighting (b = 32 s/mm{sup 2}) was determined empirically from 1H imaging of murine renal vascular signal. The method was then tested in vivo using MRSI with bipolar gradients following injection of hyperpolarized [1-{sup 13}C]pyruvate (∼80 mM at 20% polarization). Results: In simulations, vascular signal contaminated the renal metabolic signal at resolutions as high as 2 × 2 mm{sup 2} due to partial volume effects. The apparent exchange rate from pyruvate to lactate (k{sub p}) was underestimated in the presence of these artifacts due to contaminating pyruvate signal. Incorporation of bipolar gradients suppressed vascular signal and improved the accuracy of kp estimation. Experimentally, the in vivo results supported the ability of bipolar gradients to suppress vascular signal. The in vivo exchange rate increased, as predicted in simulations, from k{sub p} = 0.012 s-{sup 1} to k{sub p} = 0.020-{sup 1} after vascular signal suppression. Conclusion: We have demonstrated the limited accuracy of the two-site exchange model in the presence of vascular partial volume artifacts. The addition of bipolar gradients suppressed vascular signal and improved model accuracy in simulations. Bipolar gradients largely affected kp estimation in vivo. Currently, slow-flowing spins in small vessels and capillaries are only partially suppressed, so further improvement is possible. Funding support: Seed Grant from the Radiological Society of North America, GE Healthcare, University of Wisconsin Graduate School.

60 APPLIED LIFE SCIENCES↗

Land and Water Use Characteristics and Human Health Input Parameters for use in Environmental Dosimetry and Risk Assessments at the Savannah River Site. 2016 Update

Operations at the Savannah River Site (SRS) result in releases of small amounts of radioactive materials to the atmosphere and to the Savannah River. For regulatory compliance purposes, potential offsite radiological doses are estimated annually using computer models that follow U.S. Nuclear Regulatory Commission (NRC) regulatory guides. Within the regulatory guides, default values are provided for many of the dose model parameters, but the use of applicant site-specific values is encouraged. Detailed surveys of land-use and water-use parameters were conducted in 1991 and 2010. They are being updated in this report. These parameters include local characteristics of meat, milk and vegetable production; river recreational activities; and meat, milk and vegetable consumption rates, as well as other human usage parameters required in the SRS dosimetry models. In addition, the preferred elemental bioaccumulation factors and transfer factors (to be used in human health exposure calculations at SRS) are documented. The intent of this report is to establish a standardized source for these parameters that is up to date with existing data, and that is maintained via review of future-issued national references (to evaluate the need for changes as new information is released). These reviews will continue to be added to this document by revision.

61 RADIATION PROTECTION AND DOSIMETRY↗

Computer Modeling of Yttrium-90-Microsphere Transport in the Hepatic Arterial Tree to Improve Clinical Outcomes

Purpose: Radioembolization (RE) via yttrium-90 ({sup 90}Y) microspheres is an effective and safe treatment for unresectable liver malignancies. However, no data are available regarding the impact of local blood flow dynamics on {sup 90}Y-microsphere transport and distribution in the human hepatic arterial system. Methods and Materials: A three-dimensional (3-D) computer model was developed to analyze and simulate blood-microsphere flow dynamics in the hepatic arterial system with tumor. Supplemental geometric and flow data sets from patients undergoing RE were also available to validate the accuracy of the computer simulation model. Specifically, vessel diameters, curvatures, and branching patterns, as well as blood flow velocities/pressures and microsphere characteristics (i.e., diameter and specific gravity), were measured. Three-dimensional computer-aided design software was used to create the vessel geometries. Initial trials, with 10,000 noninteracting microspheres released into the hepatic artery, used resin spheres 32-{mu}m in diameter with a density twice that of blood. Results: Simulations of blood flow subject to different branch-outlet pressures as well as blood-microsphere transport were successfully carried out, allowing testing of two types of microsphere release distributions in the inlet plane of the main hepatic artery. If the inlet distribution of microspheres was uniform (evenly spaced particles), a greater percentage would exit into the vessel branch feeding the tumor. Conversely, a parabolic inlet distribution of microspheres (more particles around the vessel center) showed a high percentage of microspheres exiting the branch vessel leading to the normal liver. Conclusions: Computer simulations of both blood flow patterns and microsphere dynamics have the potential to provide valuable insight on how to optimize {sup 90}Y-microsphere implantation into hepatic tumors while sparing normal tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Effects of Air Pockets Around High-Dose Rate Brachytherapy Vaginal Cylinders

Purpose: Most physicians use a single-channel vaginal cylinder for postoperative endometrial cancer brachytherapy. Recent published data have identified air pockets between the vaginal cylinders and the vaginal mucosa. The purpose of this research was to evaluate the incidence, size, and dosimetric effects of these air pockets. Methods and Materials: 25 patients receiving postoperative vaginal cuff brachytherapy with a high-dose rate vaginal cylinders were enrolled in this prospective data collection study. Patients were treated with 6 fractions of 200 to 400 cGy per fraction prescribed at 5 mm depth. Computed tomography simulation for brachytherapy treatment planning was performed for each fraction. The quantity, volume, and dosimetric impact of the air pockets surrounding the cylinder were quantified. Results: In 25 patients, a total of 90 air pockets were present in 150 procedures (60%). Five patients had no air pockets present during any of their treatments. The average number of air pockets per patient was 3.6, with the average total air pocket volume being 0.34 cm{sup 3} (range, 0.01-1.32 cm{sup 3}). The average dose reduction to the vaginal mucosa at the air pocket was 27% (range, 9-58%). Ten patients had no air pockets on their first fraction but air pockets occurred in subsequent fractions. Conclusion: Air pockets between high-dose rate vaginal cylinder applicators and the vaginal mucosa are present in the majority of fractions of therapy, and their presence varies from patient to patient and fraction to fraction. The existence of air pockets results in reduced radiation dose to the vaginal mucosa.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons

Purpose: The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides ({sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source {beta}{sup -}, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the {sup 192}Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Results: Electronic equilibrium within 1% is reached for {sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for {sup 60}Co and {sup 192}Ir, respectively. Electron emissions become important (i.e., >0.5%) within 3.3 mm of {sup 60}Co and 1.7 mm of {sup 192}Ir sources, yet are negligible over all distances for {sup 137}Cs and {sup 169}Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Conclusions: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experiment Design of Secondary Neutron and Charged Particles Measurement with Stopping Targets Bombarded by 100- and 230-MeV/amu Helium Ions - Paper 124

Radiotherapy using ion beams has gained momentum in radiation oncology. While the number of proton therapy facilities that have been established or are under construction is rapidly growing, interest in heavy ion (whose atomic number Z is greater than one) radiotherapy has also been revitalized in the U.S. Helium ions, with mass and charge between protons and carbon ions, have advantages of deep penetration distances with significant peak-to-entrance dose ratios and limited dose contributions from secondary neutrons and other secondary charged fragments. In consideration of these advantages, the U.S. ion beam therapy community has expressed interests in helium ions as a potential candidate for ion beam therapy, especially pediatric cases. As such, characterizing the secondary nuclear fragment field created by primary helium ion interactions along the beam delivery devices and in human tissue is important for dose assessment and patient protection. Up to now the experimental data with respect to helium ions over the therapeutic energy range, 100 - 230 MeV/amu, is scarce compared to protons and carbon ions. Kurosawa et al. measured stopping target yields and angular spectra of neutrons, protons, deuterons and tritons produced by various target materials bombarded by 100- and 180- MeV/amu helium ions; Heilbronn et al. and Cecil et al. also measured the stopping target neutron yields by 155-, 160- and 177.5-MeV/amu helium ion bombardments. We have proposed to measure angular distributions of secondary neutrons and light charged ions produced by 100- and 230-MeV/amu helium ions bombarding stopping water and iron targets. The experiment was conducted at the Heavy Ion Medical Accelerator in Chiba (HIMAC) of the National Institute of Radiological Sciences (NIRS) in Japan this June. During the literature survey for experimental setup, we found that the ratio of the ion beam range (R) to the target depth (d) varies from 0.5 - 0.98 in the stopping target measurements either for helium ions incident on various targets or carbon ions bombarding targets as tissue surrogates. The difference in the values of ratio R/d makes comparison of experimental results complicated and require accurate corrections. Hence, how the R/d ratio and cross sectional area of the targets influence the angular distributions of secondary particles is investigated by using a Monte Carlo method in this study. The influence of the depth and the cross sectional area of stopping water and iron targets on the yield and the spectra of secondary particles induced by 100- and 230-MeV/amu He ions was studied by a Monte Carlo simulation code, PHITS. The secondary charged particles and secondary neutrons who come from breakup of projectiles are highly forward-focused, while the secondary particles produced by target breakup are nearly isotropic. As the energy of {sup 4}He ions increases from 100 MeV/amu to 230 MeV/amu, the normalized intensities of charged particles decrease more gently with increasing angles, whereas the neutron angular distribution falls quickly at angles smaller than 30 deg. and starts to exceed the normalized profile of 100 MeV/amu He from 60 deg. When the target depth increases, the impact on attenuation of secondary particles is more significant for lighter target mass and higher-energy projectiles at forward angles. Also, with deeper targets, more interactions occur between the secondary particles and the target elements, which results in more target-like fragments at large and backward angles. In respect of the cross sectional area of the stopping targets, the forward angular distributions are similar to the system with smaller cross sectional area of the targets; however, no general rule was found for how the large-angle distributions are affected by the target cross sectional area. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Synthesis of Post-fire Monitoring Activities in the Great Basin Desert, Mojave Desert, and Transition Zones

In the deserts of the American Southwest, fire return intervals of centuries to millennia are being replaced by fire return intervals of decades. This increased burn frequency has implications for post-closure management and long-term stewardship for Soils Corrective Action Units (CAUs) and Corrective Action Sites (CASs) on the Nevada National Security Site (NNSS), Tonopah Test Range, and Nevada Test and Training Range for which the U.S. Department of Energy (DOE), Environmental Management-Nevada (EM-NV) is responsible. For many CAUs and CASs, where closure-in-place alternatives were implemented or are being considered, there is a chance that these sites could burn over while they still pose a risk to the environment or human health given the long half-lives of some of the radionuclide contaminants of concern (COCs) (Shafer et al., 2007; Shafer and Gomes, 2009). Although it would have been ideal to conduct a fire-related study at a radionuclide contaminated site on the NNSS to determine how contaminated soils are transported post-fire, it was more practical to examine fires in environments analogous to where Soils Activity CAUs and CASs exist. Therefore, a series of studies were initiated at three radiologically uncontaminated analog sites to better understand the possible effects of wildfire on erosion and sediment transport by wind and water should vegetation at contaminated sites burn at the NNSS. The studies took place at the sites of the Gleason Fire, a prescribed burn that occurred near Ely, Nevada, which is in the Great Basin ecoregion; the White Rock Fire that occurred near Mesquite, Nevada, which is in the Mojave Desert ecoregion; and the Jacob Fire that occurred near Hiko, Nevada, in the transitional zone between the Great Basin Desert and the Mojave Desert. Each site was representative of one of the three ecoregions found on the NNSS. Erosion and vegetation characteristics were measured multiple times post-fire on both burned and unburned test plots at these study sites to compare and monitor the effects of fire over time. However, at the Mojave Desert site, there was an additional burn from nearly 25 years ago that was also compared with the more recent burned areas from 2013. Also, the time elapsed after the fire and the time when sampling began differed among the ecoregions. For example, at the Great Basin site, samples were collected prior to the fire and less than one month after the fire, whereas data collected at the Mojave Desert site did not occur until 22 months after the fire. The differences between the sample measurements and the time that elapsed after the fire may contribute to the variability in the data and the interpretations of the data. Runoff and water erosion were quantified through a series of rainfall and runoff simulation tests in which controlled amounts of water were delivered to the soil surface. Runoff data were collected from different microhabitats (e.g., undercanopies, interspace soils, ridges, and drainage areas). The data showed soil hydrophobicity (i.e., water repellency) on the Great Basin site for up to 12 months after the fire. The soil structure remained changed and weaker on the burned areas compared with the unburned areas for the three-year study period. Although runoff data at both the Great Basin site and transition zone site were highly variable, the post-fire runoff potential did not generally increase at either location after three years of monitoring. Mojave runoff did not differ much between fire ages or between burned and unburned areas, possibly because of the amount of vegetation growing on all three surfaces and because the fire intensity was likely lower relative to other ecoregions due to the amount of space between plants. Additionally, the measurements conducted on the Mojave fire occurred several years after the fire had burned and not within several months of the burn, which may also account for the lack of differences in runoff between burned and unburned locations. Wind erosion was assessed and quantified with a Portable In-Situ Wind ERosion Lab (PI-SWERL) on both the burned and unburned soils of different microhabitats (e.g., ridges, drainages, interspaces between plants, and plant undercanopies). Estimates of emissions (e.g., particulate matter with aerodynamic diameters less than or equal to 10 micrometers, or PM10) at different wind speeds were collected and filter samples were analyzed for chemical composition. The measurements among the fires were similar and the results of the wind erosion measurements indicate that there were seasonal influences on many parameters, but the potential for PM10 windblown dust emissions was higher on burned areas compared with unburned areas. Among the burned areas, drainages produced the most dust emissions, whereas burned ridges were the least emissive. Emissions at the Mojave site and transition zone site were similar between burned and unburned areas approximately three years after the respective fires. Emissions remained much greater on burned soils at the Great Basin site. However, site selection may have also contributed to the differences of emissions among the three study locations. Post-fire vegetation responses were documented for three years following each fire in different microhabitats (e.g., ridge, drainage, undercanopy, and interspace) at the Great Basin and transition zone sites. In 2013, at the Mojave fire site, random permanent plots were established in newly burned areas, areas that burned approximately 25 years ago, and an unburned control area. At each fire site, the regeneration of native plant species dominated the burned areas, but invasive annual grasses were present at each fire site. During the course of each three-year study, the invasive annual grasses increased in density or percentage at both the Great Basin and transition fire sites but not at the Mojave site, where annual invasive grasses remained high throughout the study period. However, the chronosequence data from the Mojave site indicate a transition to different invasive grass species with time. The post-burn vegetation at all three ecoregions is still in the early stages of succession, and shrub size should increase over time and shrub density should decrease over time. However, the recovery of the plant communities to pre-burn compositions may not occur for decades or centuries, or may not occur because of changes in climate and the presence of invasive annual grasses. Results from the three study locations suggested that contaminated soils on the NNSS that experienced wildfire had the potential for soil erosion and transport of contaminated soils. Both wind and soil runoff studies indicated that locations in the Great Basin and transition zone ecoregions were more susceptible to erosion than the Mojave Desert ecoregion, but the highest levels of erosion occurred during the early portions of the study (the first 24 months) and the Mojave Desert was not measured until 22 months after the burn. Additionally, data from the Great Basin indicated deeper soils may increase susceptibility to wind erosion. Historically, the Great Basin and transition zone ecoregions burned more frequently than the Mojave Desert because of fuel abundance and connectivity—and they continue to burn more frequently, particularly after the introduction of invasive grasses (Davies and Nafus, 2013). However, both ecoregions and the transition zone have burned with extensive, high-severity fires when certain weather and fuel conditions are met. For example, the high abundance and productivity of annual grasses and forbs—which are usually produced by above average winter precipitation—combined with early spring and summer warm, dry conditions. Future climate scenarios predict increased temperatures, variable to reduced precipitation, and larger, more extreme wildfires throughout western North America. These predictions suggest that future fires on the NNSS could increase in frequency, intensity, and severity similar to their analog ecosystems throughout the Great Basin and Mojave Desert (Dennison et al., 2014; Abatzoglou andWilliams, 2016; Westerling, 2016).

54 ENVIRONMENTAL SCIENCES↗

Dose and detectability for a cone-beam C-arm CT system revisited

Purpose: The authors had previously published measurements of the detectability of disk-shaped contrast objects in images obtained from a C-arm CT system. A simple approach based on Rose's criterion was used to scale the date, assuming the threshold for the smallest diameter detected should be inversely proportional to (dose){sup 1/2}. A more detailed analysis based on recent theoretical modeling of C-arm CT images is presented in this work. Methods: The signal and noise propagations in a C-arm based CT system have been formulated by other authors using cascaded systems analysis. They established a relationship between detectability and the noise equivalent quanta. Based on this model, the authors obtained a relation between x-ray dose and the diameter of the smallest disks detected. A closed form solution was established by assuming no rebinning and no resampling of data, with low additive noise and using a ramp filter. For the case when no such assumptions were made, a numerically calculated solution using previously reported imaging and reconstruction parameters was obtained. The detection probabilities for a range of dose and kVp values had been measured previously. These probabilities were normalized to a single dose of 56.6 mGy using the Rose-criteria-based relation to obtain a universal curve. Normalizations based on the new numerically calculated relationship were compared to the measured results. Results: The theoretical and numerical calculations have similar results and predict the detected diameter size to be inversely proportional to (dose){sup 1/3} and (dose){sup 1/2.8}, respectively. The normalized experimental curves and the associated universal plot using the new relation were not significantly different from those obtained using the Rose-criterion-based normalization. Conclusions: From numerical simulations, the authors found that the diameter of detected disks depends inversely on the cube root of the dose. For observer studies for disks larger than 4 mm, the cube root as well as square root relations appear to give similar results when used for normalization.

36 MATERIALS SCIENCE↗

Effect of intrafractional prostate motion on simultaneous boost intensity-modulated radiotherapy to the prostate: A simulation study based on intrafractional motion in the prone position

Although the prostate displacement of patients in the prone position is affected by respiration-induced motion, the effect of intrafractional prostate motion in the prone position during “simultaneous integrated boost intensity-modulated radiotherapy” (SIB-IMRT) is unclear. The purpose of this study was to evaluate the dosimetric effects of intrafractional motion on SIB-IMRT to a dominant intraprostatic lesion (IPL) using measured motion data of patients in a prone position, fixed with a thermoplastic shell. We obtained 2 orthogonal x-ray fluoroscopic images at the same moment every 0.2 seconds for 30 seconds before and after treatment, once weekly, from 7 patients with localized prostate cancer with detectable prostatic calcification. Prostate displacements in the left-right (LR), anteroposterior (AP), and superoinferior (SI) directions were calculated using the prostatic calcification as a fiducial marker. We defined the displacement between pretreatment and posttreatment as baseline drift (BD). An SIB-IMRT plan was generated in which each IPL + 3 mm received a dose of 94.5 Gy, whereas the remainder of the prostate + 7 mm received a dose of 75.6 Gy in 9 fields. A simulated plan of dose blurring was generated by the convolution of isocenter-shifted plans using measured motion data in 30 seconds and motion in 30 seconds + distance between pretreatment and posttreatment position (BD) for each of the 7 patients. The motion in 30 seconds mainly reflected respiration-induced motion. The mean displacements of BD were 1.4 mm (− 3.1 to 8.2 mm), − 2.2 mm (− 9.1 to 1.5 mm), and − 0.3 mm (− 5.0 to 1.8 mm) in the AP, SI, and LR directions, respectively. The differences in the target coverage with V{sub 90%} of the IPL and V{sub 100%} of the prostate between the simulated plan and original plan were − 3.9% to − 0.3% and − 0.6% to 1.1% for respiration-induced motion and 3.1% to − 67.8% and 3.6% to − 13.3% for BD with respiration-induced motion, respectively. The large motion of BD resulted in an inadequate coverage by the prescribed dose of the SIB-IMRT to the IPL. A 7-mm margin is recommended when real-time tracking techniques are not applied. The effect of respiration-induced motion was small, so long as a 3-mm margin was added.

61 RADIATION PROTECTION AND DOSIMETRY↗

Self-Management of Patient Body Position, Pose, and Motion Using Wide-Field, Real-Time Optical Measurement Feedback: Results of a Volunteer Study

Purpose: We present the results of a clinical feasibility study, performed in 10 healthy volunteers undergoing a simulated treatment over 3 sessions, to investigate the use of a wide-field visual feedback technique intended to help patients control their pose while reducing motion during radiation therapy treatment. Methods and Materials: An optical surface sensor is used to capture wide-area measurements of a subject's body surface with visualizations of these data displayed back to them in real time. In this study we hypothesize that this active feedback mechanism will enable patients to control their motion and help them maintain their setup pose and position. A capability hierarchy of 3 different level-of-detail abstractions of the measured surface data is systematically compared. Results: Use of the device enabled volunteers to increase their conformance to a reference surface, as measured by decreased variability across their body surfaces. The use of visual feedback also enabled volunteers to reduce their respiratory motion amplitude to 1.7 ± 0.6 mm compared with 2.7 ± 1.4 mm without visual feedback. Conclusions: The use of live feedback of their optically measured body surfaces enabled a set of volunteers to better manage their pose and motion when compared with free breathing. The method is suitable to be taken forward to patient studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A quality assurance framework for the fully automated and objective evaluation of image quality in cone-beam computed tomography

Purpose: Thousands of cone-beam computed tomography (CBCT) scanners for vascular, maxillofacial, neurological, and body imaging are in clinical use today, but there is no consensus on uniform acceptance and constancy testing for image quality (IQ) and dose yet. The authors developed a quality assurance (QA) framework for fully automated and time-efficient performance evaluation of these systems. In addition, the dependence of objective Fourier-based IQ metrics on direction and position in 3D volumes was investigated for CBCT. Methods: The authors designed a dedicated QA phantom 10 cm in length consisting of five compartments, each with a diameter of 10 cm, and an optional extension ring 16 cm in diameter. A homogeneous section of water-equivalent material allows measuring CT value accuracy, image noise and uniformity, and multidimensional global and local noise power spectra (NPS). For the quantitative determination of 3D high-contrast spatial resolution, the modulation transfer function (MTF) of centrally and peripherally positioned aluminum spheres was computed from edge profiles. Additional in-plane and axial resolution patterns were used to assess resolution qualitatively. The characterization of low-contrast detectability as well as CT value linearity and artifact behavior was tested by utilizing sections with soft-tissue-equivalent and metallic inserts. For an automated QA procedure, a phantom detection algorithm was implemented. All tests used in the dedicated QA program were initially verified in simulation studies and experimentally confirmed on a clinical dental CBCT system. Results: The automated IQ evaluation of volume data sets of the dental CBCT system was achieved with the proposed phantom requiring only one scan for the determination of all desired parameters. Typically, less than 5 min were needed for phantom set-up, scanning, and data analysis. Quantitative evaluation of system performance over time by comparison to previous examinations was also verified. The maximum percentage interscan variation of repeated measurements was less than 4% and 1.7% on average for all investigated quality criteria. The NPS-based image noise differed by less than 5% from the conventional standard deviation approach and spatially selective 10% MTF values were well comparable to subjective results obtained with 3D resolution pattern. Determining only transverse spatial resolution and global noise behavior in the central field of measurement turned out to be insufficient. Conclusions: The proposed framework transfers QA routines employed in conventional CT in an advanced version to CBCT for fully automated and time-efficient evaluation of technical equipment. With the modular phantom design, a routine as well as an expert version for assessing IQ is provided. The QA program can be used for arbitrary CT units to evaluate 3D imaging characteristics automatically.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positional Reproducibility of Pancreatic Tumors Under End-Exhalation Breath-Hold Conditions Using a Visual Feedback Technique

Purpose: To assess positional reproducibility of pancreatic tumors under end-exhalation (EE) breath-hold (BH) conditions with a visual feedback technique based on computed tomography (CT) images. Methods and Materials: Ten patients with pancreatic cancer were enrolled in an institutional review board-approved trial. All patients were placed in a supine position on an individualized vacuum pillow with both arms raised. At the time of CT scan, they held their breath at EE with the aid of video goggles displaying their abdominal displacement. Each three-consecutive helical CT data set was acquired four times (sessions 1-4; session 1 corresponded to the time of CT simulation). The point of interest within or in proximity to a gross tumor volume was defined based on certain structural features. The positional variations in point of interest and margin size required to cover positional variations were assessed. Results: The means {+-} standard deviations (SDs) of intrafraction positional variations were 0.0 {+-} 1.1, 0.1 {+-} 1.2, and 0.1 {+-} 1.0 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively (p = 0.726). The means {+-} SDs of interfraction positional variations were 0.3 {+-} 2.0, 0.8 {+-} 1.8, and 0.3 {+-} 1.8 mm in the LR, AP, and SI directions, respectively (p = 0.533). Population-based margin sizes required to cover 95th percentiles of the overall positional variations were 4.7, 5.3, and 4.9 mm in the LR, AP, and SI directions, respectively. Conclusions: A margin size of 5 mm was needed to cover the 95th percentiles of the overall positional variations under EE-BH conditions, using this noninvasive approach to motion management for pancreatic tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT image artifacts from brachytherapy seed implants: A postprocessing 3D adaptive median filter

Purpose: To design a postprocessing 3D adaptive median filter that minimizes streak artifacts and improves soft-tissue contrast in postoperative CT images of brachytherapy seed implantations. Methods: The filter works by identifying voxels that are likely streaks and estimating more reflective voxel intensity by using voxel intensities in adjacent CT slices and applying a median filter over voxels not identified as seeds. Median values are computed over a 5x5x5 mm region of interest (ROI) within the CT volume. An acrylic phantom simulating a clinical seed implant arrangement and containing nonradioactive seeds was created. Low contrast subvolumes of tissuelike material were also embedded in the phantom. Pre- and postprocessed image quality metrics were compared using the standard deviation of ROIs between the seeds, the CT numbers of low contrast ROIs embedded within the phantom, the signal to noise ratio (SNR), and the contrast to noise ratio (CNR) of the low contrast ROIs. The method was demonstrated with a clinical postimplant CT dataset. Results: After the filter was applied, the standard deviation of CT values in streak artifact regions was significantly reduced from 76.5 to 7.2 HU. Within the observable low contrast plugs, the mean of all ROI standard deviations was significantly reduced from 60.5 to 3.9 HU, SNR significantly increased from 2.3 to 22.4, and CNR significantly increased from 0.2 to 4.1 (all P<0.01). The mean CT in the low contrast plugs remained within 5 HU of the original values. Conclusion: An efficient postprocessing filter that does not require access to projection data, which can be applied irrespective of CT scan parameters has been developed, provided the slice thickness and spacing is 3 mm or less.

62 RADIOLOGY AND NUCLEAR MEDICINE↗