Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Modeling, Simulation, and Implementation of Solar-Driven Water-Splitting Devices

An integrated cell for the solar-driven splitting of water consists of multiple functional components and couples various photoelectrochemical (PEC) processes at different length and time scales. The overall solar-to-hydrogen (STH) conversion efficiency of such a system depends on the performance and materials properties of the individual components as well as on the component integration, overall device architecture, and system operating conditions. This Review focuses on the modeling- and simulation-guided development and implementation of solar-driven water-splitting prototypes from a holistic viewpoint that explores the various interplays between the components. The underlying physics and interactions at the cell level is are reviewed and discussed, followed by an overview of the use of the cell model to provide target properties of materials and guide the design of a range of traditional and unique device architectures.

14 SOLAR ENERGY↗

Greenbuilt Construction Energy Efficiency Retrofit House Demonstration - Sacramento

One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the home. The home underwent an extensive energy efficiency retrofit with a goal of achieving a 50% reduction in energy use to demonstrate the potential for other builders and homeowners in the area. The retrofit measures included installing: ENERGY STAR appliances high efficiency light roof radiant barrier additional ceiling and wall insulation double-pane, low-e windows external motorized shading and solar tubes a 16 SEER/9.75 HSPF heat pump improved ducts a whole-house fan a heat pump water heater (HPWH) integrated collector storage solar water heater (ICS SWH) and 3.2 kW of PV. In addition, the home was air sealed to reduce infiltration. Researchers from the National Renewable Energy Laboratory (NREL) performed short-term tests on the major systems installed as part of the retrofit to ensure that they were performing as expected. The systems evaluated included the space conditioning heat pump, the air handler and ducts, the HPWH, the ICS SWH, and the PV array. Some ducts were untwisted after testing revealed that two rooms were not getting sufficient airflow. Afterwards, all systems were performing as expected. In addition to testing to confirm adequate performance of all new systems, NREL was given the opportunity to use the Greenbuilt house as a laboratory house for a year. The space conditioning system and home water systems were subjected to a series of tests to determine optimal control strategies for lowering energy consumption and reducing peak (4:00-7:00 p.m.) energy consumption during the summer. The different cooling strategies considered included two different precooling schedules, drawing the external shades during the day and using the whole-house fan at night, and combinations of those. The most effective strategy for reducing overall energy consumption was the use of external shades, which cut the daily cooling load by 34% and reduced the energy use during peak hours by 40%. The different precooling strategies eliminated the peak load entirely but actually increased daily cooling energy use. The use of shades and the advanced precooling strategy increased the daily energy use by 5% but eliminated all peak use and maintained a comfortable home. These results were verified over the entire summer using an Energy Plus model of the home. The hot water system was tested in two configurations: the HPWH alone and the ICS solar water heater paired with the HPWH. Six hot water draw profiles, varying in terms of daily hot water volume, time of day for hot water use, and the duration of the draws, were imposed on the hot water system to test their effects on performance. When operating alone in the summer, the HPWH operated with a COP around 2.2, except for a draw that used a quarter of the averaged daily hot water usage, which had an average COP of 1.6. The combination of ICS and HPWH resulted in larger COPs, but also more variability depending on the draw profile. The standard, hourly draw profile produced the highest COP of 6.4. The quarter volume draw profile had the lowest COP of 2.8 for the combined system. Relative to a standard electric water heater, the HPWH operating alone reduced the peak load by 56% and the combined ICS and HPWH system completely eliminated the peak load.

air sealing↗

FINAL REPORT: SUNSHINE STATE SOLAR GRID INITIATIVE (SUNGRIN) PHASE 1 (Critical Milestone Review Version)

This report provides details on the activities and accomplishments of Phase 1 of the Sunshine State Solar Grid Initiative (SUNGRIN) Project for the period beginning 4/28/2010 and ending 12/31/2011. SUNGRIN is a five-phase high-penetration solar PV project within the Systems Integration (SI) area of the Solar Energy Technologies (SETP) Program, under the SunShot Initiative. SUNGRIN is focused on understanding and enabling high-penetration grid-connected solar PV through simulation assisted studies of actual Florida utility high-penetration distribution circuits as well as substations and, to a limited extent, the bulk power system. Each phase builds and expands upon the efforts of the previous phase, leading to a comprehensive examination and understanding of high-penetration solar PV issues, from the solar resource to the conversion and integration technologies to the electric power system, with Florida and it’s utility partners providing the broad range of conditions and system integration scenarios necessary to develop useful insight and solutions. This phase, Phase 1, was funded with American Recovery and Reinvestment Act (ARRA) funds. This version of the final report is organized to align with statement of project objectives (SOPO) critical milestones.

14 SOLAR ENERGY↗

23.4% monolithic epitaxial GaAsP/Si tandem solar cells and quantification of losses from threading dislocations

A 2-terminal, dual-junction, epitaxially integrated, GaAsP/Si tandem solar cell with an 3rd party certified efficiency of 23.4 % was fabricated via MOCVD growth on an ex-situ produced Si sub cell. The drastic efficiency improvement over the authors previous peer-reviewed demonstration of such a device architecture is examined. Critical advancements in top cell design to maximize short wavelength response were critical in enabling improved top cell response. An in-depth analysis of this champion tandem cell has identified key loss mechanisms which elucidate the pathway for further efficiency gains. First, voltage dependent collection efficiency in the GaAsP top cell is the primary cause of fill factor losses currently limiting efficiency. Analysis of spectrally resolved I–V measurements and analytical device modeling and indicate poor diffusion length due to elevated dislocation densities as the likely cause for the voltage dependent collection efficiency. Second, modeling for the GaAs 0.75 P 0.25 top cell, using experimental data at multiple dislocation densities, provides quantitative understanding of the current and voltage losses associated with threading dislocations providing a clear efficiency pathway with reduction in dislocation density. Finally, Si subcell modeling identifies the pathway for further Si subcell advances over the present, simplistic design, which has yet to employ the known benefits of rear surface texture or dielectric passivation.

14 SOLAR ENERGY↗

Optical properties enhancement of thermal energy media for consistently high solar absorptivity

This study aimed to evaluate the optical properties of particles intended for use as thermal energy absorbers in generation 3 concentrated solar power systems. Their characterization involved UV–Vis NIR measurements with an integrating sphere for solar absorptivity, while a reflectometer was employed to measure thermal emittance. By combining absorptivity and emittance data, the solar absorption efficiency was calculated. Laser flash analysis, differential scanning calorimetry, and thermogravimetric analysis were utilized to determine thermal conductivity and specific heat. The solar absorptivity of the particles was initially measured at 0.90. After exposure to air at 1000 °C, it decreased to 0.73. However, following a reduction process, the particle recovered absorptivity of 0.90. The thermal aging and recovery were repeated multiple times, consistently achieving an absorptivity of 0.90. The thermal conductivity of the particles ranged from 0.50 to 0.88 W/(m-K). Solar absorptivity was found to be influenced by the types of iron oxide present in the particles. Particles with a predominance of hematite exhibited decreased solar absorptivity, while those containing magnetite, wüstite, and iron showed increased absorptivity. The estimated cost of the developed particles was more than ten times lower than that of current products. Given that component costs significantly impact the levelized cost of electricity (LCOE), this price reduction corresponded to an 8 % decrease in LCOE compared to other products. The low-cost thermal energy media show great promise for contributing to a reduced LCOE in the third generation of concentrating solar power systems.

14 SOLAR ENERGY↗

Enhanced sub-bandgap efficiency of a solid-state organic intermediate band solar cell using triplet–triplet annihilation

Conventional solar cells absorb photons with energy above the bandgap of the active layer while sub-bandgap photons are unharvested. One way to overcome this loss is to capture the low energy light in the triplet state of a molecule capable of undergoing triplet–triplet annihilation (TTA), which pools the energy of two triplet states into one high energy singlet state that can then be utilized. This mechanism underlies the function of an organic intermediate band solar cell (IBSC). Here, we report a solid-state organic IBSC that shows enhanced photocurrent derived from TTA that converts sub-bandgap light into charge carriers. Femtosecond resolution transient absorption spectroscopy and delayed fluorescence spectroscopy provide evidence for the triplet sensitization and upconversion mechanisms, while external quantum efficiency measurements in the presence of a broadband background light demonstrate that sub-bandgap performance enhancements are achievable in this device. In conclusion, the solid-state architecture introduced in this work serves as an alternative to previously demonstrated solution-based IBSCs, and is a compelling model for future research efforts in this area.

14 SOLAR ENERGY↗

In situ energetics modulation enables high-efficiency and stable inverted perovskite solar cells

In contrast to conventional (n-i-p) perovskite solar cells (PSCs), inverted (p-i-n) PSCs offer enhanced stability and integrability with tandem solar cell architectures, which have garnered increasing interest. However, p-i-n cells suffer from energy level misalignment with transport layers, imbalanced transport of photo-generated electrons and holes, and significant defects with the perovskite films. Here we introduce tris(2,4,6-trimethyl-3-(pyridin-3-yl)phenyl)borane (3TPYMB), a nonionic n-type molecule that, through hydrogen bonding and Lewis acid-base reactions with perovskite surfaces or grain boundaries, enables in situ modulation of perovskite energetics, effectively mitigating the key challenges of p-i-n PSCs. The p-i-n PSCs incorporating 3TPYMB achieve a certified quasi-steady-state power conversion efficiency of 24.55 +- 0.33%, with a reverse scan efficiency of 25.58%. Finally, they also exhibit exceptional stability, with unencapsulated devices retaining 97.8% of their initial efficiency after 1,800 h of continuous operation at maximum power point under N 2 atmosphere, 1 sun illumination and 60 °C conditions.

14 SOLAR ENERGY↗

Observations and Lessons Learned From Installing Residential Roofing-Integrated Photovoltaics

Building-sited solar photovoltaics (PV) could play a key role in decarbonizing the building sector either through racked and mounted PV or through Building-integrated PV (BIPV). BIPV is installed into the building envelope itself, with solar cells and/or modules forming the outer layer of a building structure, thus transforming a single-purpose structure into one that serves the dual purposes of the building envelope and electricity. BIPV can be applied to building roofs, facades, awnings, pergolas, windows, skylights, balustrades, and other external surfaces. Given BIPV products vary widely, the focus of this research is residential roofing integrated PV (RIPV), where solar is incorporated into or otherwise replaces the roofing material. Previous research suggests that residential RIPV could reduce customer acquisition, labor, supply chain, and equipment costs. These products have yet to realize these cost savings and deployment remains significantly less than conventional rooftop PV as a relative share of the addressable market in the US. One potential barrier to broader residential roofing integrated PV deployment may be higher costs relative to conventional rooftop PV, primarily because the design and installation of these products is still evolving. Here, we explore residential RIPV cost-reduction opportunities by analyzing installation processes. Our study documents residential RIPV installations at 2 reroofing sites and the equivalent of 9 new construction sites in California through a methodology known as time and motion study. We also conducted interviews with subject-matter experts to identify barriers and solutions to maximize these products' market penetration. Our time and motion study breaks the RIPV installation process into four steps: 1) staging, unloading, and roof preparation; 2) fire resistant underlayment(s) (synthetic material laid between roof shingles and roof deck); 3) flashings and PV installation; and 4) wiring and monitoring. We measure the time required for each step in terms of worker-hours, representing an hour of labor from a single worker. We further normalize process time by dividing worker-hours by kilowatt (kW) of system capacity. The most time-intensive step was flashings and PV installation, taking around 2.4 worker-hours per kW on average and accounting for around 60% of the process time for an average installation. The total installation process took on average about 6.4 and 3.5 worker-hours per kW at the reroofing sites and new construction sites, respectively. For comparison, a previous time and motion study documented a time of 6.9 worker-hours per kW for conventional rooftop PV. The shorter RIPV installation times are consistent with previous studies suggesting that RIPV could be installed faster than conventional rooftop PV. The time and motion results and feedback from interviewees provide insights into potential residential RIPV cost reduction opportunities. Several interviewees suggested that these products would be more efficient if PV installation was more fully integrated into the roofing/construction industries, which currently use separate supply chains and skillsets. Further integration could reduce supply chain delays and labor force redundancies. Future research could explore specific ways to integrate these industries to help realize the cost savings potential of RIPV.

14 SOLAR ENERGY↗

Life Cycle Assessment of Pasture-based Agrivoltaic Systems: Emissions and Energy Use of Integrated Rabbit Production

Agrivoltaic systems, which deliberately maximize the utility of a single parcel of land for both solar photovoltaic (PV) electricity production and agriculture, have been demonstrated as a viable technology that can ameliorate competing land uses and meet growing energy and food demands efficiently. The goal of this study is to assess the environmental impacts of a novel pasture-based agrivoltaic concept: co-farming rabbits and solar PV. A life cycle assessment (LCA) quantified the impacts of 1) the integrated agrivoltaic concept in comparison to conventional practices including 2) separate rabbit farming and PV production and 3) separate rabbit farming and conventional electricity production. The impact assessment methods employed to determine the environmental impacts were IPCC 2013 global warming potential 100a V1.03 and fossil energy demand V1.11. The results indicate that the pasture-based agrivoltaic system produces the least amount of greenhouse gas emissions (3.8 million kg CO₂ equivalent) and demands the least amount of fossil energy (46 million MJ) per functional unit of cumulative MWh output of electricity and cumulative kg of meat over 30 years in comparison to the two other scenarios under study. The pasture-based agrivoltaic system features a dual synergy that consequently produces 69.3% less emissions and demands 82.9% less fossil energy compared to non-integrated production. The potential for agrivoltaic systems to significantly reduce environmental impacts revealed by this LCA, which was limited to emissions and fossil energy demand, demonstrates that integrated solar and pasture-based agricultural systems are superior to conventional practices in terms of their comparatively lower emission and energy intensity. These findings provide empirical support for increased agrivoltaic system development more broadly.

14 SOLAR ENERGY↗

Assessment of wind and solar power in global low-carbon energy scenarios: An introduction

This preface introduces the special section on the assessment of wind and solar in global low-carbon energy scenarios. The special section documents the results of a coordinated research effort to improve the representation of variable renewable energies (VRE), including wind and solar power, in Integrated Assessment Models (IAM) and presents an overview of the results obtained in the underlying coordinated model inter-comparison exercise.

24 POWER TRANSMISSION AND DISTRIBUTION↗

What you get is not always what you see—pitfalls in solar array assessment using overhead imagery

Effective integration planning for small, distributed solar photovoltaic (PV) arrays into electric power grids requires access to high quality data: the location and power capacity of individual solar PV arrays. Unfortunately, national databases of small-scale solar PV do not exist; those that do are limited in their spatial resolution, typically aggregated up to state or national levels. While several promising approaches for solar PV detection have been published, strategies for evaluating the performance of these models are often highly heterogeneous from study to study. The resulting comparison of these methods for practical applications for energy assessments becomes challenging and may imply that the reported performance evaluations overly optimistic. The heterogeneity comes in many forms, each of which we explore in this work: the degree of diversity of the locations and sensors (e.g. different satellites, aerial photography) from which the training and validation data originate, the validation of ground truth (manual annotation of imagery vs known solar PV locations), the level of spatial aggregation (e.g. array-level vs regional estimates), and inconsistencies in the training and validation datasets (e.g. different datasets are used for each study and those data are not always made accessible). For each, we discuss emerging practices from the literature to address them or suggest directions of future research. As part of our investigation, we evaluate solar PV identification performance in two large regions: the entire state of Connecticut and the city of San Diego, CA. In Connecticut, we also use 33,114 known parcel-level solar PV installations from Berkeley Lab’s Tracking the Sun dataset to evaluate parcel-level performance and evaluate capacity estimates using 169 municipalities. We also make our code (which we call SolarMapper), pre-trained models, training data, and predictions publicly available and provide a web portal for interactively inspecting each prediction that was made. Here our findings suggest that traditional performance evaluation of the automated identification of solar PV from satellite imagery may be optimistic due to common limitations in the validation process. The takeaways from this work are intended to inform and catalyze the large-scale practical application of automated solar PV assessment techniques by energy researchers and professionals.

14 SOLAR ENERGY↗

Far-UV spectroscopy of the planet-hosting star WASP-13: High-energy irradiance, distance, age, planetary mass-loss rate, and circumstellar environment

Several transiting hot Jupiters orbit relatively inactive main-sequence stars. For some of those, the logR{sub HK}{sup ′} activity parameter lies below the basal level (−5.1). Two explanations have been proposed so far: (i) the planet affects the stellar dynamo, (ii) the logR{sub HK}{sup ′} measurements are biased by extrinsic absorption, either by the interstellar medium (ISM) or by material local to the system. We present here Hubble Space Telescope/COS far-UV spectra of WASP-13, which hosts an inflated hot Jupiter and has a measured logR{sub HK}{sup ′} value (−5.26), well below the basal level. From the star’s spectral energy distribution we obtain an extinction E(B − V) = 0.045 ± 0.025 mag and a distance d = 232 ± 8 pc. We detect at ≳4σ lines belonging to three different ionization states of carbon (C i, C ii, and C iv) and the Si iv doublet at ∼3σ. Using far-UV spectra of nearby early G-type stars of known age, we derive a C iv/C i flux ratio–age relation, from which we estimate WASP-13's age to be 5.1 ± 2.0 Gyr. We rescale the solar irradiance reference spectrum to match the flux of the C iv 1548 doublet. By integrating the rescaled solar spectrum, we obtain an XUV flux at 1 AU of 5.4 erg s{sup −1} cm{sup −2}. We use a detailed model of the planet’s upper atmosphere, deriving a mass-loss rate of 1.5 × 10{sup 11} g s{sup −1}. Despite the low logR{sub HK}{sup ′} value, the star shows a far-UV spectrum typical of middle-aged solar-type stars, pointing toward the presence of significant extrinsic absorption. The analysis of a high-resolution spectrum of the Ca ii H and K lines indicates that the ISM absorption could be the origin of the low logR{sub HK}{sup ′} value. Nevertheless, the large uncertainty in the Ca ii ISM abundance does not allow us to firmly exclude the presence of circumstellar gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Case Study of a Californian Brewery to Potentially Use Concentrating Solar Power for Renewable Heat Generation

With the increasing relevance and acceptance of solar thermal for industrial process heat (IPH), a case study for a proposed concentrating solar power (CSP) integration into an existing Californian brewery is highlighted. The thermal generation from a 1 MWth solar field was modelled in the System Advisor Model (SAM), and the economics considered the viability of the project where different variables such as the installed solar field cost were investigated on metrics such as Net Present Value (NPV) and payback period. For the Base Case, without the 30% Investment Tax Credit (ITC), and using a 2017 Federal income tax rate of 35%, the project’s NPV reached $0 (i.e., the project becomes viable), when the installed solar field cost reached $158/m2. With the 30% ITC and 35% tax, the solar field installed cost is estimated at $324/m2 to obtain an NPV = $0. The biggest influences on project viability measured by NPV were the project life, Federal tax rate, and the solar field cost.

case study↗

A Stochastic Power Network Calculus for Integrating Renewable Energy Sources into the Power Grid

Renewable energy such as solar and wind generation will constitute an important part of the future grid. As the availability of renewable sources may not match the load, energy storage is essential for grid stability. In this paper we investigate the feasibility of integrating solar photovoltaic (PV) panels and wind turbines into the grid by also accounting for energy storage. To deal with the fluctuation in both the power supply and demand, we extend and apply stochastic network calculus to analyze the power supply reliability with various renewable energy configurations. To illustrate the validity of the model, we conduct a case study for the integration of renewable energy sources into the power system of an island off the coast of Southern California. In particular, we asses the power supply reliability in terms of the average Fraction of Time that energy is Not-Served (FTNS).

Wang, K↗