Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar simulator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

ATS-6 - Solar cell flight experiment after 325 days in synchronous orbit

Preliminary results of the Applications Technology Satellite-6 (ATS-6) solar cell flight experiment to isolate and identify solar cell degradation mechanisms resulting from particulate radiation and to obtain specific design data applicable to extended synchronous spacecraft missions are presented. The experiment includes 80 individual cells representing 16 different solar cell/cover glass configurations. Most of the cells are 0.030 cm thick boron doped n/p cells with 10 ohm cm resistivity and solder-coated AgTi contacts. The voltage-current characteristics were measured regularly. The data for the first 325 days of flight show short circuit currents 1-8% higher than measurements made with solar simulations. Maximum power varied between -1 and +6%. After 50 days in orbit the degradation of short circuit current due to ultraviolet effects was determined to be about 2%. All cells except those with fluorinated ethylene propylene covers performed well after 325 days.

Goldhammer, L. J.↗

Performance correlations of five solar collectors tested simultaneously outdoors

Collector thermal efficiency, and efficiency degradation with time were measured for 5 flat-plate solar collectors tested simultaneously in an outdoor solar collector test facility. Results indicate that by using collector performance parameters which account for diffuse isolation, outdoor data recorded on cloud days can be used as a measure of performance, as long as the ratio of direct to total insolation exceeds approximately 0.6. These outdoor results also show good agreement with thermal efficiency data obtained indoors in a solar simulator. Significant efficiency degradation occurred on only one of the five collectors exposed to outdoor conditions for a period of one to two years.

Miller, D. R.↗

Baseline performance of solar collectors for NASA Langley solar building test facility

The solar collector field contains seven collector designs. Before operation in the field, the experimental performances (thermal efficiencies) of the seven collector designs were measured in an indoor solar simulator. The resulting data provided a baseline for later comparison with actual field test data. The simulator test results are presented for the collectors as received, and after several weeks of outdoor exposure with no coolant (dry operation). Six of the seven collector designs tested showed substantial reductions in thermal efficiency after dry operation.

Knoll, R. H.↗

Indoor and outdoor measurements of performance of photovoltaic arrays

A description of the techniques and methodology for making outdoor I-V measurements of solar cells is given. Temperature and irradiance measurement, experimental arrangement, data acquisition system and I-V data transformations are discussed. Data are presented comparing outdoor measurements to indoor measurements using a pulsed solar simulator.

Curtis, H. B.↗

Terrestrial photovoltaic measurements, 2

The following major topics are discussed; (1) Terrestrial solar irradiance; (2) Solar simulation and reference cell calibration; and (3) Cell and array measurement procedures. Numerous related subtopics are also discussed within each major topic area.

Source record↗

Thermal design of the IUE hydrazine auxiliary propulsion system

The International Ultraviolet Explorer is a large astronomical observatory scheduled to be placed in a three-axis stabilized synchronous orbit in the fourth quarter of 1977. The Hydrazine Auxiliary Propulsion System (HAPS) must perform a number of spacecraft maneuvers to achieve a successful mission. This paper describes the thermal design which accomplishes temperature control between 5 and 65 C for all orbital conditions by utilizing multilayer insulation and commandable component heaters. A primary design criteria was the minimization of spacecraft power by the selective use of the solar environment. The thermal design was carefully assessed and verified in both spacecraft thermal balance and subsystem solar simulation testing.

Joseph T. Skladany↗

Performance correlations of five solar collectors tested simultaneously outdoors

Collector thermal efficiency, and efficiency degradation with time were measured for 5 flat-plate solar collectors tested simultaneously in an outdoor solar collector test facility. Results indicate that by using collector performance parameters which account for diffuse insolation, outdoor data recorded on 'cloudy' days can be used as a measure of performance, as long as the ratio of direct to total insolation exceeds approximately 0.6. These outdoor results also show good agreement with thermal efficiency data obtained indoors in a solar simulator. Significant efficiency degradation occurred on only one of the five collectors exposed to outdoor conditions for a period of one to two years.

Miller, D. R.↗

Indoor tests of a hot-air solar collector

Data taken relating indoor testing using solar simulator at Marshall Space Center has been compared with data taken during outdoor tests in previous studies. Data includes tests on thermal performance, time constance, and incidence-angle modifier tests in table/graph form.

Source record↗

Performance evaluation of an air solar collector

Indoor tests on signal-glazed flat-plate collector are described in report. Marhsall Space Flight Center solar simulator is used to make tests. Test included evaluations on thermal performance under various combinations of flow rate, incident flux, inlet temperature, and wind speed. Results are presented in graph/table form.

Source record↗

Laboratory measurements of radiance and reflectance spectra of dilute primary-treated sewage sludge

The feasibility of remotely monitoring ocean dumping of waste products such as acid and sewage sludge is evaluated. The laboratory arrangement, solar simulator, and test results from three experiments conducted in the laboratory are described. Radiance and reflectance spectra are presented for primary-treated sewage sludge mixed with two types of base water. Results indicate that upwelled reflectance varies in a near-linear manner with concentration and that the sludge has a practically flat signal response between 420 and 970 nm. Well-defined upwelled reflectance spectra were obtained for the sewage-sludge mixtures at all wavelengths and concentrations. The spectral-reflectance values appeared to be influenced by the type of base water, but this influence was small, especially for the mixtures with low concentrations of sewage sludge.

Usry, J. W.↗

Owens-Illinois liquid solar collector materials assessment

From the beginning, it was noted that the baseline drawings for the liquid solar collector exhibited a distinct weakness concerning materials specification where elastomers, plastics, and foam insulation materials were utilized. A relatively small effort by a competent design organization would alleviate this deficiency. Based on results obtained from boilout and stagnation tests on the solar simulator, it was concluded that proof testing of the collector tubes prior to use helps to predict their performance for limited service life. Fracture mechanics data are desirable for predicting extended service life and establishing a minimum proof pressure level requirement. The temperature capability of this collector system was increased as the design matured and the coating efficiency improved. This higher temperature demands the use of higher temperature materials at critical locations in the collector.

Nichols, R. L.↗

MSFC Assessment of Owens-Illinois SUNPAK Collector Problems

An in-depth assessment is presented of problems encountered with the Owens-Illinois SUNPAK collector installed in several ERDA solar system demonstration sites. Analysis and independent tests of the collector in the MSFC Solar Simulator where the system failure conditions were duplicated are included. The basic design of the SUNPAK collector was shown to be sound; however, material limitations dictate that near-term applications constraints be recognized by system designers. MSFC recommendations were presented to ERDA in March 1977. Subsequent retrofit activity by Owens-Illinois appears to have been effective in demonstrating the integrity of the SUNPAK collector.

Wiesenmaier, B. L.↗

High altitude calibration of thirty-three silicon and gallium arsenide solar cells on a sounding rocket

Twenty-nine n/p silicon and four p/n gallium arsenide solar cells were calibrated on board a high-altitude sounding rocket which provided a stable platform outside the earth's atmosphere. Approximately 75 characteristic current-voltage curves were obtained for each of thirty-two of the cells; the calibration accuracy for both current and voltage was 0.1%. For comparison, the short circuit current, open circuit voltage, and maximum power of the solar cells were also measured under solar simulators (air mass = 0) and on the ground (air mass = 1.2).

Thomas, N. L.↗

Temperature control analysis and flight results for the Viking Orbiter 1975 Mars atmospheric water detection instrument

The Mars atmospheric water detector (MAWD) instrument required a temperature of -70 C at the detector. The monochromator housing required +20 C + or - 1 C. This instrument was located on the scan platform, and slewed across two solar panels. The thermal design for the detector was an open flat plate radiator thermally isolated on four 1-in. tubes, with a flexible strap to the detector. MAWD radiator view factors and heat loads from the spacecraft were determined for the Lander on and off, for all angular positions of the scan platform. Subsystem and system tests were performed using the 25-ft diameter solar simulator. In-flight results have shown no anomalies, and no degradation has been observed. Servo-controlled heaters are used to control the temperature.

Kavanagh, H. M.↗

U.S. terrestrial solar cell calibration and measurement procedures

An outline is presented of changes in measurement procedures concerning solar cells. Outdoor measurements of cell performance based on pyranometer or pyrheliometer determination of intensity are discouraged. The absolute scale of irradiance is to be adopted as soon as possible. The standard atmosphere conditions are 1000 W/sq m irradiance, temperature 28 C, air mass 1.5, and precipitable water vapor content of 2 cm. The allowable light sources for solar simulation are short arc xenon lamps, pulsed xenon lamps, and dichroic filtered tungsten lamps. Key considerations in the design of a reference cell are considered and approaches for the matching of a reference cell to a test cell or modules are discussed.

Brandhorst, H. W., Jr.↗

Weathering of a liquid-filled solar collector

Report describes procedures and results of tests for effects of weathering on flat-plate liquid solar collector. Thermal performance was measured before and after natural weathering for 15-1/2 months by using Marshall Space Flight solar simulator.

Source record↗