Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid state detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The FRAM robotic telescope for atmospheric monitoring at the Pierre Auger Observatory

FRAM (F/Photometric Robotic Atmospheric Monitor) is a robotic telescope operated at the Pierre Auger Observatory in Argentina for the purposes of atmospheric monitoring using stellar photometry. As a passive system which does not produce any light that could interfere with the observations of the fluorescence telescopes of the observatory, it complements the active monitoring systems that use lasers. We discuss the applications of stellar photometry for atmospheric monitoring at optical observatories in general and the particular modes of operation employed by the Auger FRAM. We describe in detail the technical aspects of FRAM, the hardware and software requirements for a successful operation of a robotic telescope for such a purpose and their implementation within the FRAM system.

Optics↗

Reflectivity of VUV-sensitive silicon photomultipliers in liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. Here, the reflectivity is determined to be 25–36 % at an angle of incidence of 20° for the four samples and increases to up to 65 % at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

(pin diodes, APDs, SiPMs, G-APDs, CCDs, EBCCDs, EM↗

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Batch VUV4 characterization for the SBC-LAr10 scintillating bubble chamber

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (V BD ), the SiPM gain (g SiPM ), the rate of change of g SiPM with respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (P CA ) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate V BD to tens of mV precision and DCR close to Poissonian error. The temperature dependence of V BD was found to be 56 ± 2 mV K -1 , and m on average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 10 3 e- PE -1 V -1 . The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K -1 corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of P CA was estimated to be 4000 ± 1000 ppm K -1 . P CA estimated from the average across all SiPMs is a better estimator than the P CA calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DUNE Photon Detection System

The Deep Underground Neutrino Experiment (DUNE) aims to provide a broad physics program primarily addressed to probing CP violation in the neutrino sector and identifying the neutrino mass hierarchy. The search for proton decay, the observation of supernova neutrino bursts, and the investigation of solar neutrinos represent other additional goals of DUNE experiment, which can be enhanced by the use and the high performances of the Photon Detection System (PDS). Using the technology based on liquid argon Time Projection Chamber (LArTPC), the experiment plans to observe neutrino interactions inside detectors located 1300 km away from the Long Baseline Neutrino Facility (LBNF) at Fermi National Accelerator Laboratory (FNAL), where the neutrinos are produced. The experiment consists of two main parts, respectively the far and near detectors. The far site will comprise four detector modules. The first module is constituted by a vertical drift single-phase LArTPC, while the second module provides a horizontal drift single-phase LArTPC. The configurations of the other modules are still under definition. Neutrino detection in LArTPCs is achieved by identifying the charge and light generated from its interactions with liquid argon. The wire planes of the instrumented anode and the PDS detect these signals, respectively. The PDS in the first two modules, detailed in the present document, uses a modified version of the so-called ARAPUCA technology, named X-ARAPUCA. This system consisting of a highly reflecting box with an entrance window made by dichroic filters and wavelength shifters, creates a trap to detect the VUV (128 nm) scintillation photons. The X-ARAPUCA of the first module is called Supercell, and it has dimensions of 488×100 mm 2 , while Megacell is the second module version, with an active area of 60×60 cm 2 . This latter configuration also represents a significant technological advancement. Since half of the modules are placed on the cathode at high voltage, they are powered and read out using innovative power-over-fiber (PoF) and signal-over-fiber (SoF) technologies. Meanwhile, the other half are installed in a membrane behind the field cage, with a total transparency of around 70%.

Neutrino detectors↗

Preliminary design study. Shuttle modular scanning spectroradiometer

Fundamental concepts on which to base a detailed design for a Shuttle Modular Scanning Spectroradiometer were developed, and a preliminary design is presented. The recommended design features modularity and flexibility. It includes a 75-cm f/1.7-telescope assembly in an all-reflective Schmidt configuration, a solid state scan system (pushbroom) with high resolution over a 15 deg field of view, and ten detector channels covering the spectral range from 0.45 to 12.5 micrometers. It uses charge transfer device techniques to accommodate a large number of detector elements for earth observation measurements. Methods for in-flight radiometric calibration, for image motion compensation, and for data processing are described. Recommendations for ground support equipment are included, and interfaces with the shuttle orbiter vehicle are illustrated.

Source record↗

Search For Excited Cascade Hypersons (¿*-) Using the CLAS12 Spectrometer at Jefferson Laboratory

The number of experimentally observed doubly strange Cascade states to date is far fewer than has been predicted theoretically. The CLAS12 Very Strange physics program (E12- 11-005A) at the Thomas Jefferson National Accelerator Facility aims to study the electroproduction of these states using the newly upgraded CEBAF Large Acceptance Spectrometer for 12 GeV (CLAS12) in experimental Hall B. In this project, the reaction ep ! e0K+K+??? ! e0K+K+K?(?=?0) is studied using CLAS12 Run Group A (RG-A) data sets taken by impinging electron beams of 10:2 and 10:6 GeV energies on an LH2 target. Scattered electrons are detected with either the Forward Detector (FD), covering a polar angle range of 5? to 35? to study electroproduction, or with the Forward Tagger (FT), covering a polar angle range of 2:5? to 4:5?, to study quasi-real photoproduction. The CLAS12 detector with nearly a 4? solid angle coverage is used to detect scattered electrons and charged kaons in the ?final state. ?=?0 hyperons are reconstructed using the missing mass technique to explore intermediate doubly-strange hyperons (???) that decay to K? and ?=?0. No statistically significant ??? states other than the ???(1530) were found in the missing mass spectra based on the currently available statistics in the CLAS12-FD acceptance only. A maximum log-likelihood method is implemented to determine the statistical significance and the upper limits on the ???(1820) electroproduction cross section by constructing 95% confidence level boundaries on the ???(1820) yields. Additional research was conducted to investigate the upper limit electroproduction cross section of the reaction ep ! e0K+K+??? ! e0K+K+K?(?=?0) as a function of the electroproduced ??? mass and the differential cross section ( d?dMM(e0K+K+) ) as a function of missing mass MM(e0K+K+) for electroproduction and quasi-real photoproduction processes.

Khanal, Achyut↗

Non-Markovian Hole Excess Noise in Avalanche Amorphous Selenium Thin Films

Enhancing the signal-to-noise ratio in avalanche photodiodes by utilizing impact ionization gain requires materials exhibiting low excess noise factors. Amorphous selenium (a-Se) as a wide bandgap at ~2.1 eV, a solid-state avalanche layer, demonstrates single-carrier hole impact ionization gain and manifests ultralow thermal generation rates. A comprehensive study of the history dependent and non-Markovian nature of hot hole transport in a-Se was modeled using a Monte Carlo (MC) random walk of single hole free flights, interrupted by instantaneous phonon, disorder, hole–dipole, and impact-ionization scattering interactions. The hole excess noise factors were simulated for 0.1–15 μm a-Se thin-films as a function of mean avalanche gain. The hole excess noise factors in a-Se decreases with an increase in electric field, impact ionization gain, and device thickness. The history dependent nature of branching of holes is explained using a Gaussian avalanche threshold distance distribution and the dead space distance, which increases determinism in the stochastic impact ionization process. An ultralow non-Markovian excess noise factor of ~1 was simulated for 100 nm a-Se thin films corresponding to avalanche gains of 1000. Future detector designs can utilize the nonlocal/non-Markovian nature of the hole avalanche in a-Se, to enable a true solid-state photomultiplier with noiseless gain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comprehensive study of the X-ray structure and spectrum of IC 443

This paper presents the results of a comprehensive study of the X-ray emission from the supernova remnant IC 443, using the solid state spectrometer, IPC, and high-resolution images of the Einstein Observatory, and the medium-energy detector of the HEAO 1 A-2 experiment. A soft X-ray appearance was observed, highly atypical of a supernova remnant in the adiabatic phase, with little correlation between X-ray and optical or radio features. The best-fit models of the low-energy X-ray spectrum of the brightest area of the remnant suggest either that the remnant has not yet attained ionization equilibrium or that the X-rays arise in a multiphase medium. Pronounced soft X-ray spectral differences across the remnant are accounted for by variations in absorption by an intervening molecular cloud. The analysis suggests that, despite the atypical X-ray appearance, the X-ray emission in IC 443 is probably confined to a thin (0.1 pc) shell.

Petre, R.↗

Atmospheric Trace Gas Abundances and Stable Isotope Ratios via IR-LIF

We propose to develop new technologies with support provided by PIDDP that will enable the in situ measurements of abundances and stable isotope ratios in important radiatively and biogenically active gases such as carbon dioxide, carbon monoxide, water, methane, nitrous oxide, and hydrogen sulfide to very high precision (0.1 per mil or better for the isotopic ratios, for example). Such measurements, impossible at present, could provide pivotal new constraints on the global (bio)geochemical budgets of these critical species, and could also be used to examine the dynamics of atmospheric transport on Mars, Titan, and other solar system bodies. We believe the combination of solid state light sources with imaging of the IR laser induced fluorescence (IR-LIF) via newly available detector arrays will make such in situ measurements possible for the first time. Even under ambient terrestrial conditions, the LIF yield from vibrational excitation of species such as water and carbon dioxide should produce emission measures well in excess of ten billion photons/sec from samples volumes of order 1 c.c. These count rates can, in principle, yield detection limits into the sub-ppt range that are required for the in situ isotopic study of atmospheric trace gases. While promising, such technologies are relatively immature, but developing rapidly, and there are a great many uncertainties regarding their applicability to in situ IR-LIF planetary studies. We therefore feel PIDDP support will be critical to developing these new tools, and propose a three-year program to combine microchip near-IR lasers with low background detection axes and state-of-the-art HgCdTe detectors developed for astronomical spectroscopy to investigate the sensitivity of IR-LIF under realistic planetary conditions, to optimize the optical pumping and filtering schemes for important species, and to apply the spectrometer to the non-destructive measurement of stable isotopes in a variety of test samples. These studies form the necessary precursors to the development of compact, lightweight stable isotope/trace gas sensors for future planetary missions.

Blake, Geoffrey A.↗

Development of a Submillimeter/Far-Infrared Radiometer for Cirrus Measurements

We introduce a low-cost, lightweight and compact polarisation-sensitive radiometer for the measurement of Cirrus clouds in the submillimeter and far-infrared region (10 150 cm-1). It is widely recognised that enhanced global measurements of cirrus properties are essential to the development of General Circulation and Climate Prediction Models since cirrus clouds have a strong effect on the Earth's Global Radiation Budget. The purpose of this project is to design and build a novel instrument suitable for aircraft deployment in order to measure Ice Water Path (IWP) along with cirrus particle size and shape. This airborne instrument, which is currently under development in Cardiff, will serve as a prototype for a future satellite-based radiometer. The radiometer will capitalize on the ongoing measurements of the NASA-led, Fourier Transform interferometer-based, FIRSC (Far-Infrared Sensor for Cirrus) instrument for which Cardiff has been closely associated. Data from FIRSC campaigns is being used to select optimum radiometer channels that exhibit good sensitivity to specific cirrus. This new multichannel radiometer will, however, have some key advantages over similar spectroscopic instruments, for example, portability, increased optical efficiency, a multi-angle field of view and a reduced integration period leading to an improved spatial resolution. The radiometer will benefit from the application of state-of-the-art submm/FIR polarizer and solid filter technology currently being developed in Cardiff. The instrument will require a detector array that is robust enough to withstand aircraft/space deployment.

Hayton, Darren↗

Mechanical quantum sensing in the search for dark matter

Numerous astrophysical and cosmological observations are best explained by the existence of dark matter, a mass density which interacts only very weakly with visible, baryonic matter. Here, searching for the extremely weak signals produced by this dark matter strongly motivate the development of new, ultra-sensitive detector technologies. Paradigmatic advances in the control and readout of massive mechanical systems, in both the classical and quantum regimes, have enabled unprecedented levels of sensitivity. In this white paper, we outline recent ideas in the potential use of a range of solid-state mechanical sensing technologies to aid in the search for dark matter in a number of energy scales and with a variety of coupling mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗

Solid State Radiation Dosimeters for Space and Medical Applications

This report describes the development of two radiation monitors (RADMON's) for use in detecting total radiation dose and high-energy particles. These radiation detectors are chip-size devices fabricated in 1.2 micrometer CMOS and have flown in space on both experimental and commercial spacecraft. They have been used to characterize protons and electrons in the Earth's radiation belts, particles from the Sun, and protons used for medical therapy. Having proven useful in a variety of applications, the detector is now being readied for commercialization.

Buehler, Martin G.↗

A 100Mbps coherent optical link demonstration using frequency stabilized solid state lasers

The design, implementation, and performance evaluation of a 100Mbps binary phase shift keying (BPSK) coherent optical link using frequency stabilized solid state lasers is described. In this demonstration, the transmitted data is binary phase modulated at 100Mbps using an external resonant cavity phase modulator. At the receiving end, the signal is detected using a balanced heterodyne detector. An auxiliary frequency tracking loop (FTL) is used to help the initial frequency acquisition before handing over to the carrier phase tracking loop. The FTL is implemented using a delay line discriminator, and the detected frequency error is fed back to the local oscillator laser to close the tracking loop. Phase coherent reception is achieved by synchronizing the carrier phase using a Costas tracking loop. The demonstration showed that a high data rate phase coherent optical link can be implemented using frequency stabilized solid state lasers.

Chen, CHIEN-C.↗

Multispectral linear array

The Multispectral Linear Array (MLA) is a solid-state earth imagery radiometer operating in the 'push-broom' mode and using a focal plane containing multiple spectral band linear detector arrays. The MLA sensor offers the capability for increased spatial and spectral resolution with multiple selectable bands and in-orbit operation flexibility. Both free-flyer (satellite) and Shuttle-attached instrument designs have been studied. Four Shuttle-attached MLA instrument design studies were initiated in 1982, and the concepts resulting from these studies are described.

Richard, H. L.↗

Einstein SSS and MPC observations of Aql X-1 and 4U1820-30

The results of timing and spectral analyses of the X-ray sources Aql X-1 (X1908+005) and 4U1820-30 (NGC6624) are reported using data obtained with the Einstein SSS (Solid State Spectrometer) and MPC (Monitor Proportional Counter) instruments. A classic type I burst was observed from Aql X-1 in both detectors and a coherent modulation with a period of 131.66 + or - 0.02 ms and a pulsed fraction of 10 percent was detected in the SSS data. There is no evidence for a loss of coherance during the approximately 80 sec when the burst is observable. The 2 sigma upper limit on the rate of change of the pulse period is 0.00005s/s. It is argued that an asymmetrical burst occurring on a neutron star rotating at 7.6 Hz offers a plausible explanation for the oscillation. The data from 4U1820-30 show that the amplitude of the 685 sec modulation, identified as the orbital period, is independent of energy down to 0.6 keV. The SSS data show that the light curve in the 0.6 to 4.5 keV band is smoother than at higher energies.

Kelley, R. L.↗

The Galileo Solid-State Imaging experiment

The Galileo Orbiter's Solid-State Imaging (SSI) experiment uses a 1.5-m focal length TV camera with 800 x 800 pixel, virtual-phase CCD detector in order to obtain images of Jupiter and its satellites which possess a combination of sensitivity levels, spatial resolutions, geometric fidelity, and spectral range that are unmatched by earlier imaging data. After describing the performance of this equipment on the basis of ground calibrations, attention is given to the SSI experiment's Jupiter system observation objectives; these encompass atmospheric science, satellite surfaces, ring structure, and 'darkside' experiments.

Belton, Michael J. S.↗