At least 505 records · Page 28

Machine Learning for Automated Weld Quality Monitoring and Control

Resistance Spot Welding (RSW) is a critical process in the automotive industry, valued for its cost-effectiveness, short cycle time, and robustness. However, achieving consistent high-quality joints remains challenging due to the complex interplay of various factors, like materials, processes, and manufacturing uncertainties, etc. Under the collaborative project between Oak Ridge National Laboratory (ORNL) and General Motors (GM), we have developed a robust and expansible machine learning (ML) framework aimed at enhancing quality control in RSW. By harnessing the power of machine learning, we have developed the ability to ensure every aspect of the welding process, from the initial process design stage to the final weld joint quality. The framework operates by analyzing a variety of data streams, including in-line process signals, process parameters, materials, and postprocessed weld joint data. Through this analysis, the models have been trained to detect deviations from optimal quality standards, leveraging their ability to identify signature data patterns and anomalies within in-line signals and construct complex correlations between these signals and weld quality parameters. Meanwhile, the machine learning framework is designed to adapt to a variety of materials, including high strength steels and aluminum alloys, etc. Its flexible architecture facilitates the incorporation of diverse data sources and features, enabling precise modeling and prediction across a broad range of material properties and weld quality variables. The expansible ML frameworks represent a promising transformation in weld quality monitoring and control, empowering industry to achieve high levels of efficiency, consistency, and reliability in manufacturing.

42 ENGINEERING↗

Characterizing the Vertical Distribution of Aerosols Over the ARM SGP Site

This project focused on: 1) evaluating the performance of the DOE ARM SGP Raman lidar system in measuring profiles of water vapor and aerosols, and 2) the use of the Raman lidar measurements of aerosol and water vapor profiles for assessing the vertical distribution of aerosols and water vapor simulated by global transport models and examining diurnal variability of aerosols and water vapor. The highest aerosol extinction was generally observed close to the surface during the nighttime just prior to sunrise. The high values of aerosol extinction are most likely associated with increased scattering by hygroscopic aerosols, since the corresponding average relative humidity values were above 70%. After sunrise, relative humidity and aerosol extinction below 500 m decreased with the growth in the daytime convective boundary layer. The largest aerosol extinction for altitudes above 1 km occurred during the early afternoon most likely as a result of the increase in relative humidity. The water vapor mixing ratio profiles generally showed smaller variations with altitude between day and night. We also compared simultaneous measurements of relative humidity, aerosol extinction, and aerosol optical thickness derived from the ARM SGP Raman lidar and in situ instruments on board a small aircraft flown routinely over the ARM SGP site. In contrast, the differences between the CARL and IAP aerosol extinction measurements are considerably larger. Aerosol extinction derived from the IAP measurements is, on average, about 30-40% less than values derived from the Raman lidar. The reasons for this difference are not clear, but may be related to the corrections for supermicron scattering and relative humidity that were applied to the IAP data. The investigators on this project helped to set up a major field mission (2003 Aerosol IOP) over the DOE ARM SGP site. One of the goals of the mission was to further evaluate the aerosol and water vapor retrievals from this lidar system. Analysis of the aerosol and water vapor data collected by the Raman lidar during the 2003 Aerosol IOP indicated that the sensitivity of the lidar was significantly lower than when the lidar was initially deployed. A detailed analysis after the IOP of the long-term dataset demonstrated that the lidar began degrading in early 2002, and that it lost approximately a factor of 4 in sensitivity between 2002 and 2004. We participated in the development of the remediation plan for the system to restore its initial performance. We conducted this refurbishment and upgrade from May- September 2004. This remediation lead to an increase in the signal-to-noise ratio of 10 and 30 for the Raman lidar's water vapor mixing ratio and aerosol backscatter coefficient data, respectively as compared to the signal strengths when the system was first deployed. The DOE ARM Aerosol Lidar Validation Experiment (ALIVE), which was conducted during September 2005, evaluated the impact of these modifications and upgrades on the SGP Raman lidar measurements of aerosol extinction and optical thickness. The CARL modifications significantly improved the accuracy and temporal resolution of the aerosol measurements. Aerosol extinction profiles measured by the Raman lidar were also used to evaluate aerosol extinction profiles and aerosol optical thickness (AOT) simulated by aerosol models as part of the Aerosol module inter-Comparison in global models (AEROCOM) (http://nansen.ipsl.jussieu.fr/AEROCOM/aerocomhome.html) project. There was a wide range in how the models represent the aerosol extinction profiles over the ARM SGP site, even though the average annual AOT represented by the various models and measured by CARL and the Sun photometer were in general agreement, at least within the standard deviations of the averages. There were considerable differences in the average vertical distributions among the models, even among models that had similar average aerosol optical thickness. Deviations between mean aerosol extinction profiles were generally small (~20-30%) for altitudes above 2 km, and grew considerably larger below 2 km.

54 ENVIRONMENTAL SCIENCES↗

Fermilab Muon $g - 2$ experiment: Current status

The Muon $g$ - 2 experiment at Fermilab (E989) is currently measuring the muon magnetic anomaly with a goal precision of 140 part per billion, which will be a fourfold precision improvement over the current best measurement by the previous Muon $g$ -2 experiment at the Brookhaven Laboratory (BNL). The BNL-measured value of the muon magnetic anomaly and the corresponding Standard Model (SM) best estimate differ by more than three standard deviation which inspired the current measurement as well as a theoretical drive for a significantly more precise calculation of the muon magnetic anomaly to rule out (or establish) statistical fluctuation as the origin of such a huge discrepancy. Stable central values along with 4-fold precision improvements in both theoretical (SM) and experimental fronts, would imply a ~ 7σ discrepancy and that will be a clear hint of the physics beyond the Standard Model. Such an unprecedented precision demands state-of-the-art technological improvements in all involved components to keep the systematic uncertainty below 70 ppb. This paper reports the current status of the E989 experiment after two years of data acquisition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strong tW scattering at the LHC

Deviations of the top electroweak couplings from their Standard Model values imply that certain amplitudes for the scattering of third generation fermions and longitudinally polarized vector bosons or Higgses diverge quadratically with momenta. This high-energy growth is a genuine signal of models where the top quark is strongly coupled to the sector responsible for electroweak symmetry breaking. We propose to profit from the high energies accessible at the LHC to enhance the sensitivity to non-standard top-Z couplings, which are currently very weakly constrained. To demonstrate the effectiveness of the approach, we perform a detailed analysis of tW → tW scattering, which can be probed at the LHC via pp→$t\bar{t}$Wj. By recasting a CMS analysis at 8 TeV, we derive the strongest direct bounds to date on the Ztt couplings. We also design a dedicated search at 13 TeV that exploits the distinctive features of the $t\bar{t}$Wj signal. Lastly, we present other scattering processes in the same class that could provide further tests of the top-Higgs sector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence for the Higgs-boson Yukawa coupling to tau leptons with the ATLAS detector

Results of a search for H → ττ decays are presented, based on the full set of proton-proton collision data recorded by the ATLAS experiment at the LHC during 2011 and 2012. The data correspond to integrated luminosities of 4.5 fb –1 and 20.3 fb –1 at centre-of-mass energies of √s=7 TeV and √s=8 TeV respectively. All combinations of leptonic (τ → ℓνν¯ with ℓ = e, μ) and hadronic (τ → hadrons ν) tau decays are considered. An excess of events over the expected background from other Standard Model processes is found with an observed (expected) significance of 4.5 (3.4) standard deviations. This excess provides evidence for the direct coupling of the recently discovered Higgs boson to fermions. The measured signal strength, normalized to the Standard Model expectation, of μ = 1.43 –0.37 +0.43 is consistent with the predicted Yukawa coupling strength in the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the cross section for top quark pair production in association with a W or Z boson in proton-proton collisions at $ \sqrt{s}=13 $ TeV

Here, a measurement is performed of the cross section of top quark pair production in association with a W or Z boson using proton-proton collisions at a center-of-mass energy of 13 TeV at the LHC. The data sample corresponds to an integrated luminosity of 35.9 fb$^{-1}$, collected by the CMS experiment in 2016. The measurement is performed in the same-sign dilepton, three- and four-lepton final states. The production cross sections are measured to be $\sigma(\mathrm{t}\overline{\mathrm{t}}\mathrm{W})= 0.77 ^{+0.12}_{-0.11}\text{(stat)} ^{+0.13}_{-0.12}\text{(syst)}$ pb and $\sigma(\mathrm{t}\overline{\mathrm{t}}\mathrm{Z}) = 0.99 ^{+0.09}_{-0.08}\text{(stat)} ^{+0.12}_{-0.10}\text{(syst)}$ pb. The expected (observed) signal significance for the $\mathrm{t}\overline{\mathrm{t}}\mathrm{W}$ production in same-sign dilepton channel is found to be 4.5 (5.3) standard deviations, while for the $\mathrm{t}\overline{\mathrm{t}}\mathrm{Z}$ production in three- and four-lepton channels both the expected and the observed significances are found to be in excess of 5 standard deviations. The results are in agreement with the standard model predictions and are used to constrain the Wilson coefficients for eight dimension-six operators describing new interactions that would modify $\mathrm{t}\overline{\mathrm{t}}\mathrm{W}$ and $\mathrm{t}\overline{\mathrm{t}}\mathrm{Z}$ production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dual-Channel Enzymatic Inhibition Measurement (DEIM) Coupling Isotope Substrate via Matrix-Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry

A novel dual-channel enzymatic inhibition measurement (DEIM) method was developed to improve the repeatability with light/heavy isotope substrates, producing reliable relative standard deviations (< 3%) by employing acetylcholinesterase (AChE) as the model enzyme. The matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) was adapted for enzyme-inhibited method due to its good salt-tolerance and high throughput; meanwhile, dual-channel enzymatic reactions were performed to improve the repeatability of each well. The acetylcholinesterase inhibition measurement was conducted by mixing the quenched enzyme reaction solution of blank group (with heavy isotope as substrate) and experimental group (with light isotope as substrate), of which the inhibition rate might be affected by isotope effects. Hence, inverse study and Km measurement were implemented to validate the method. The inverse study shows similar inhibition rate (68.9 and 70.3%) and the Km of isotope substrates are analogous (0.139 and 0.135 mM), which demonstrated that the novel method is feasible to AChE inhibition measurement. Finally, the method was applied to herb extracts, half of which exhibit inhibition to AChE. The precise dual-channel enzymatic inhibition measurement (DEIM) method could be regarded as a promising approach to potential enzyme inhibitor screening. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Muon g-2 experiment at Fermilab

The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment aμ. This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation discrepancy between the measured value and the Standard Model prediction. The new measurement at Fermilab aims to improve the precision by a factor of four reducing the total uncertainty from 540 parts per billion (BNL E821) to 140 parts per billion (Fermilab E989). This paper gives the status of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

QCD Effects in Cosmology

The cosmological evolution in the radiation dominated regimen is usually computed by assuming an ideal relativistic thermal bath. In this note, we discuss the deviation from the noninteraction assumption. In either the standard model (SM) and the minimal supersymmetric standard model (MSSM), the main contribution comes from the strong interaction. An understanding of these effects are important for precision measurements and for the evolution of scalar modes, where the commented corrections constitute the main source of the dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tests of alternative quantum theories with neutrons

According to Bell’s theorem, every theory based on local realism is at variance with certain predictions of quantum mechanics. A theory that maintains realism but abandons reliance on locality, which has been proposed by Leggett, is incompatible with experimentally observable quantum correlations. In our experiment correlation measurements of spin-energy entangled single-neutrons violate a Leggett-type inequality by more than 7.6 standard deviations. The experimental data falsify the contextual realistic model and are fully in favor of quantum mechanics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Disconnected covariance of 2-point functions in large-scale structure

Optimal analyses using the 2-point functions of large-scale structure probes require accurate covariance matrices. A covariance matrix of the 2-point function comprises the disconnected part and the connected part. While the connected covariance only becomes important on small scales, the disconnected covariance is dominant on large scales, where the survey window has a significant impact. In this work, we develop an analytical method to compute the disconnected covariance, accounting for the window effect. Derived under the flat-sky approximation, our formalism is applicable to wide surveys by swapping in the curved-sky window functions. Our method works for both the power spectrum and the correlation function, and applies to the covariances of various probes including the multipoles and the wedges of 3D clustering, the angular and the projected statistics of clustering and shear, as well as the cross covariances between different probes. We verify the analytic covariance against the sample covariance from the galaxy mock simulations in two test cases: (1) the power spectrum multipole covariance, and (2) the joint covariance of the projected correlation function and the correlation function multipoles. Our method achieve good agreement with the mocks, while at a negligible computational cost. Unlike mocks, our analytic covariance is free of sampling noise, which often leads to numerical problems and the need to inflate the errors. In addition, our method can use the best-fit power spectrum as input, in contrast to the standard procedure of using a fiducial model that may deviate significantly from the truth. We also show that a naive diagonal power spectrum covariance underestimates the signal-to-noise ratio compared to our analytic covariance. The code that accompanies this paper is available at https://github.com/eelregit/covdisc.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative constraints on the transport properties of hot partonic matter from semi-inclusive single high transverse momentum pion suppression in Au+Au collisions at {radical}(s{sub NN})=200 GeV

The PHENIX experiment has measured the suppression of semi-inclusive single high-transverse-momentum {pi}{sup 0}'s in Au+Au collisions at {radical}(s{sub NN})=200 GeV. The present understanding of this suppression is in terms of energy loss of the parent (fragmenting) parton in a dense color-charge medium. We have performed a quantitative comparison between various parton energy-loss models and our experimental data. The statistical point-to-point uncorrelated as well as correlated systematic uncertainties are taken into account in the comparison. We detail this methodology and the resulting constraint on the model parameters, such as the initial color-charge density dN{sup g}/dy, the medium transport coefficient <q-circumflex>, or the initial energy-loss parameter {epsilon}{sub 0}. We find that high-transverse-momentum {pi}{sup 0} suppression in Au+Au collisions has sufficient precision to constrain these model-dependent parameters at the {+-}20-25% (one standard deviation) level. These constraints include only the experimental uncertainties, and further studies are needed to compute the corresponding theoretical uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Top Yukawa coupling determination at high energy muon collider

The Top Yukawa coupling profoundly influences several core mysteries linked to the electroweak scale and the Higgs boson. We study the feasibility of measuring the Top Yukawa coupling at high energy muon colliders by examining the high energy dynamics of the weak boson fusion to top quark pair processes. A deviation of the Top Yukawa coupling from the Standard Model would lead to a modified VV → t⁢t¯ process, violating unitarity at high energy. Our analysis reveals that utilizing a muon collider with a center-of-mass energy of 10 TeV and an integrated luminosity of 10 ab –1 allows us to investigate the Top Yukawa coupling with a precision surpassing 1.5%, more than one order of magnitude better than the precision from t⁢t¯⁢ℎ channel at muon colliders. This precision represents a notable enhancement compared to the anticipated sensitivities of the High-Luminosity LHC (3.4%) and those at muon colliders derived from the t⁢t¯H process.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Heavy Neutral Leptons via Axionlike Particles at Neutrino Facilities

Heavy neutral leptons (HNLs) are often among the hypothetical ingredients behind nonzero neutrino masses. If sufficiently light, they can be produced and detected in fixed-target-like experiments. We show that if the HNLs belong to a richer—but rather generic—dark sector, their production mechanism can deviate dramatically from expectations associated with the standard-model weak interactions. In more detail, we postulate that the dark sector contains an axionlike particle (ALP) that naturally decays into HNLs. Since ALPs mix with the pseudoscalar hadrons, the HNL flux might be predominantly associated with the production of neutral mesons (e.g., π 0 , η ) as opposed to charge hadrons (e.g., π ± , K ± ). In this case, the physics responsible for HNL production and decay are not directly related and experiments like DUNE might be sensitive to HNLs that are too weakly coupled to the standard model to be produced via weak interactions, as is generically the case of HNLs that play a direct role in the type-I seesaw mechanism. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TH-A-18C-07: Noise Suppression in Material Decomposition for Dual-Energy CT

Purpose: A general problem of dual-energy CT (DECT) is that the decomposition is sensitive to noise in the two sets of dual-energy projection data, resulting in severely degraded qualities of decomposed images. We have previously proposed an iterative denoising method for DECT. Using a linear decomposition function, the method does not gain the full benefits of DECT on beam-hardening correction. In this work, we expand the framework of our iterative method to include non-linear decomposition models for noise suppression in DECT. Methods: We first obtain decomposed projections, which are free of beam-hardening artifacts, using a lookup table pre-measured on a calibration phantom. First-pass material images with high noise are reconstructed from the decomposed projections using standard filter-backprojection reconstruction. Noise on the decomposed images is then suppressed by an iterative method, which is formulated in the form of least-square estimation with smoothness regularization. Based on the design principles of a best linear unbiased estimator, we include the inverse of the estimated variance-covariance matrix of the decomposed images as the penalty weight in the least-square term. Analytical formulae are derived to compute the variance-covariance matrix from the measured decomposition lookup table. Results: We have evaluated the proposed method via phantom studies. Using non-linear decomposition, our method effectively suppresses the streaking artifacts of beam-hardening and obtains more uniform images than our previous approach based on a linear model. The proposed method reduces the average noise standard deviation of two basis materials by one order of magnitude without sacrificing the spatial resolution. Conclusion: We propose a general framework of iterative denoising for material decomposition of DECT. Preliminary phantom studies have shown the proposed method improves the image uniformity and reduces noise level without resolution loss. In the future, we will perform more phantom studies to further validate the performance of the purposed method. This work is supported by a Varian MRA grant.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correcting scan-to-scan response variability for a radiochromic film-based reference dosimetry system

Purpose: In radiochromic film dosimetry systems, measurements are usually obtained from film images acquired on a CCD-based flatbed scanner. The authors investigated factors affecting scan-to-scan response variability leading to increased dose measurement uncertainty. Methods: The authors used flatbed document scanners to repetitively scan EBT3 radiochromic films exposed to doses 0–1000 cGy, together with three neutral density filters and three blue optical filters. Scanning was performed under two conditions: scanner lid closed and scanner lid opened/closed between scans. The authors also placed a scanner in a cold room at 9 °C and later in a room at 22 °C and scanned EBT3 films to explore temperature effects. Finally, the authors investigated the effect of altering the distance between the film and the scanner’s light source. Results: Using a measurement protocol to isolate the contribution of the CCD and electronic circuitry of the scanners, the authors found that the standard deviation of response measurements for the EBT3 film model was about 0.17% for one scanner and 0.09% for the second. When the lid of the first scanner was opened and closed between scans, the average scan-to-scan difference of responses increased from 0.12% to 0.27%. Increasing the sample temperature during scanning changed the RGB response values by about −0.17, −0.14, and −0.05%/°C, respectively. Reducing the film-to-light source distance increased the RBG response values about 1.1, 1.3, and 1.4%/mm, respectively. The authors observed that films and film samples were often not flat with some areas up to 8 mm away from the scanner’s glass window. Conclusions: In the absence of measures to deal with the response irregularities, each factor the authors investigated could lead to dose uncertainty >2%. Those factors related to the film-to-light source distance could be particularly impactful since the authors observed many instances where the curl of film samples had the potential to cause dose uncertainty in excess of 5%. Two expedients will eliminate the uncertainties: a transparent sheet (preferably glass) placed over the scanned film keeps the film-to-light source distance constant, and an EBT3 reference film included in all scans provides correction factors for measured response values.

60 APPLIED LIFE SCIENCES↗

Microstructure Scale Lithium-Ion Battery Modeling: Part II. On In-Plane Heterogeneities and the Mechanisms that Regulate Them

Li-ion batteries performance and degradation are typically modeled at the macroscopic scale, that is neglecting in-plane heterogeneities that can arise from non-uniform electrode microstructures. Herein, a microstructure scale electrochemical model is used to quantify the impact of microstructure heterogeneity on cell performance during fast charging. The model predicts the electrolyte and solid concentration in-plane standard deviation can reach, respectively, ≈200 mol·m −3 and 6–7 kmol·m −3 locally. Further, the intercalation current density in-plane relative standard deviation can reach extremely high values, around 100% in the cathode and well above 100% in the anode graphite. These denote highly non-uniform lithiation rates and material utilization within each slice of the microstructure along the cell thickness. Non-uniform curvatures, at the particle scale (surface roughness) and between particles (size distribution), were found to initiate these in-plane heterogeneities, while an OCP-induced mechanism subsequently regulates them. The present model provides new insights into small length scale heterogeneity impact on battery performance not available with standard macro-scale/P2D modeling.

25 ENERGY STORAGE↗

First Flavor-Tagged Determination of Bounds on Mixing-Induced CP Violation in B{sub s}{sup 0}{yields}J/{psi}{phi} Decays

This Letter describes the first determination of bounds on the CP-violation parameter 2{beta}{sub s} using B{sub s}{sup 0} decays in which the flavor of the bottom meson at production is identified. The result is based on approximately 2000 B{sub s}{sup 0}{yields}J/{psi}{phi} decays reconstructed in a 1.35 fb{sup -1} data sample collected with the CDF II detector using pp collisions produced at the Fermilab Tevatron. We report confidence regions in the two-dimensional space of 2{beta}{sub s} and the decay-width difference {delta}{gamma}. Assuming the standard model predictions of 2{beta}{sub s} and {delta}{gamma}, the probability of a deviation as large as the level of the observed data is 15%, corresponding to 1.5 Gaussian standard deviations.