At least 505 records · Page 28

Optimization of Preparation Method, Nucleating Agent, and Stabilizers for Synthesizing Calcium Chloride Hexahydrate (CaCl2.6H2O) Phase Change Material

This study investigates improvements in low-cost latent heat storage material calcium chloride hexahydrate (CaCl2.6H2O). Its melting point is between 25 and 28 °C, with relatively high enthalpy (170–190 J/g); however, this phase change material (PCM) shows supercooling and phase separation. In CaCl2.6H2O incongruent melting causes lower hydrates of CaCl2 to form, which affects the overall energy storage capacity and long-term durability. In this work, PCM performance enhancement was achieved by adding SrCl2.6H2O as a nucleating agent and NaCl/KCl as a stabilizer to prevent supercooling and phase separation, respectively. We investigated the PCM preparation method and optimized the proportions of SrCl2.6H2O and NaCl/KCl. Thermal testing for 25 cycles combined with DSC and T-history testing was performed to observe changes in enthalpy, phase transitions and supercooling over the extended period of usage. X-ray diffraction was used to verify crystalline structure in the compounds. It was found that the addition of 2 wt.% of SrCl2.6H2O reduced supercooling from 12 °C to 0 °C compared to unmodified CaCl2.6H2O. The addition of 5 wt.% NaCl or KCl proved to effectively suppress separation and the melting enthalpy achieved was 169 J/g–178 J/g with congruent melting over 25 cycles, with no supercooling and almost no reduction in the latent heat.

42 ENGINEERING↗

Multi-agent AI collaboration for digital twin development and assessment

Developing a digital twin (DT) model involves different steps that encompass formulating requirements, model development, implementation, and assessment with respect to real applications. Human expertise is required to coordinate and implement different steps in the DT development and assessment process. However, certain parts of this process can be automated using artificial intelligence (AI) agents for efficient workflow development. In this work, we test and analyze a multiagent AI collaboration with humans in the loop to automate different elements of the DT development and assessment process. To implement the workflow for multiagent AI DT development and assessment, we use Autogen, a multiagent framework developed by Microsoft. Autogen offers a modular and flexible framework for configuring and designing task-specific multiagent workflows. In this framework, large language models (LLMs) form the core intelligence of the AI agents where the quality and performance of the automated element is governed by the inherent capabilities and knowledge base of the LLM. We use retrieval augmented generation to supplement the LLM with relevant domain-specific information for DT requirement formulation. We illustrate this multiagent workflow using a case study on a thermal energy storage system, focusing on how AI agents can collaborate with humans to expedite and optimize different elements of DT development and assessment process.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Coupled Experimental and High-Temperature Discrete-Element Method Modeling Studies of Aluminosilicate Particle Handling in Concentrated Solar Power Environments

Chemically inert, aluminosilicate based particles have been investigated as both a thermal transport and sensible energy storage medium for concentrated solar power facilities. These particles will experience a wide range of operating temperatures (300-1000 K) and handling conditions (dense to dilute falling particle curtains, dense granular flows, or dense structures), requiring specially-designed and optimized infrastructures. The relative influence of collisional and frictional interactions between particles varies based on temperature-dependent particulate properties and greatly impacts the bulk, granular flow behavior. These underlying physics are captured using discrete element method modeling tools. However, this modeling method is computationally expensive as each particle position and interaction is tracked during the simulation. These modeling methods are further complicated by introducing temperature-dependent particle properties, high-temperature radiative exchange, and directional irradiation sources experienced by granular flows in concentrated solar power environments. Coupled experimental and numerical studies of aluminosilicate particles in rotary kilns and dense particle curtains were performed for bulk temperatures up to 1073 K. The three particle types investigated included Carbobead HSP 30 /60, Carbobead CP 30/60, and Granusil 4030. Temperature, spatial, and velocity profile data were extracted from experimental runs using embedded K-type thermocouple probes and particle image velocimetry techniques. Experimental and numerical studies were compared using spatial temperature profiles, velocity fields, and shape profiles of the bulk, granular flows. Numerical models were developed using commercially available discrete element method modeling software, Aspherix®. Existing Aspherix® functionality was expanded by introducing coupled radiative exchange modeling tools. The laboratory-scale rotary kiln was developed to investigate the steady-state heat and mass transfer performance of aluminosilicate particles based on particle type, bulk handling temperature, and wall roughness. The rotational speed of the rotary kiln was varied to control the relative impact of collisional and frictional effects upon the granular flow behavior. Heat and mass transfer performance was categorized based on the Froude number and the observed flow regimes of slipping, rolling, cascading, and centrifuging. Coupled discrete element method modeling studies were used to evaluate the effects of temperature-dependent, particulate mechanical properties upon bulk flow behavior and upon the relative effects of radiative, advective, and/or conductive heat transfer. A high-temperature (< 1073 K) falling particle curtain was similarly fabricated to investigate the heat and mass transfer performance of aluminosilicate particles in particle handling situations dominated by inter-particle collisions. The impact of particle type, flow preheat temperatures (< 1073K), and bulk mass flow rates were investigated upon the particle curtain shape, temperature, and velocity profiles. Coupled discrete element method modeling studies were performed to evaluate the varying impact of temperature-dependent, particulate mechanical properties on the bulk flow behavior and the temperature profile of the particle curtain.

14 SOLAR ENERGY↗

An Innovative Design of High-Temperature, Sensible Molten Salt Thermal Energy Storage Systems With Geopolymer Insulation

This project aims to mitigate the risks of the current molten salt TES tank designs. The goal is to create a more reliable and cost-effective TES by (1) developing a new material solution for internal thermal insulation and (2) by designing a concrete-based tank structure to eliminate metal-related issues (e.g., corrosion, thermomechanical failure, etc.). Firstly, the project aims to engineer a composite refractory insulation material that possesses sufficient thermal insulation properties without significantly sacrificing the resistance to salt permeation and mechanical strength, which is the major trade-off in traditional refractory insulation design. The primary objective is to perform materials design and optimization of the composite refractory to achieve the required thermal and mechanical properties as suitable internal insulation for molten salt TES. Secondly, the project aims to design a concrete-based TES system with conventional low- cost Portland cement serving as the primary tank structure and the aforementioned composite refractory as the internal thermal insulation and salt containment. The objective is to investigate the technical and economical feasibilities of concrete tanks for high- temperature molten salt storage applications.

14 SOLAR ENERGY↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60°C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant: Preprint

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99 ®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60 °C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Power and energy capacity tradeoffs in an all-aqueous copper thermally regenerative ammonia battery

Thermally regenerative ammonia batteries (TRABs) can provide energy storage and produce electrical power from low-grade waste heat instead of electricity. The use of all-aqueous copper-based electrolytes has recently produced higher power densities than those achieved using previous TRAB approaches based on reversible metal deposition and dissolution processes, but further gains are possible in power and energy density. We investigated the limitations of power and energy density and how they are impacted by the electrolyte composition and discharge currents. By increasing the ammonia concentration from 1 to 5 M, the power density of the battery increased from 11.2 to 28.5 mW cm –2 , but the energy density decreased from 0.56 to 0.31 Wh L –1 . Increasing discharge current densities from 4 to 12.5 mA cm –2 increased the average power density during discharge from 2.4 to 5.9 mW cm –2 without appreciable losses in energy density. Increasing the copper concentration from 0.1 to 0.5 M increased both energy density to 2.15 Wh L –1 and energy efficiency to 2.2% but did not substantially impact the power density. Furthermore, these results represent the highest performance metrics achieved for a low-grade waste heat to electricity system.

25 ENERGY STORAGE↗

CSP Plant Optimization Study for the California Power Market (“CalCSP”) (Final Technical Report)

Concentrating Solar Power (CSP) with thermal energy storage offers a unique and strategic opportunity to support California’s clean energy transition. Unlike photovoltaic (PV) systems, CSP with thermal storage can generate electricity after sunset and during periods of high demand, making it a valuable complement to intermittent renewable resources. CSP also provides synchronous, inertia-contributing generation, long-duration storage, and flexible dispatch—capabilities increasingly important as thermal plants retire. This report summarizes the findings of the CSP Plant Optimization Study for the California Power Market or “CalCSP study,” which evaluated the technical, economic, environmental, and policy factors that influence the deployment of CSP technologies in California. The CalCSP study was conducted to assess how CSP can contribute to California’s long-term decarbonization goals while enhancing grid reliability, supporting local economic development, and making efficient use of land and transmission resources. It draws on detailed modeling of CSP performance and costs, site suitability analysis, policy reviews, and stakeholder engagement across utilities, regulators, developers, and community organizations. The analysis focuses on mature molten-salt tower technology and incorporates lessons learned from the global CSP fleet, distinguishing today’s CSP from earlier first-of-a-kind projects in the U.S. The findings support a more prominent role for CSP in California’s evolving clean energy landscape. With strategic planning, targeted policy support, and continued cost improvements, CSP can complement PV and batteries to deliver reliable, around-the-clock clean electricity—especially in areas with high solar resource and constrained grid capacity.

14 SOLAR ENERGY↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review of energy storage technologies for demand-side management in industrial facilities

Demand-side management (DSM) in industrial facilities provides an opportunity for substantial amounts of energy cost savings, since industrial facilities are the largest energy consuming sectors globally. In this work, energy storage (ES) technologies are critically reviewed and compared with industrial DSM in mind. ES technologies reviewed herein include lithium-ion battery energy storage (BES), sodium-sulfur BES, lead-acid BES, flow BES, supercapacitor ES, superconducting magnetic ES, thermal ES, flywheel ES, pumped hydro ES, and compressed air ES. The fundamentals of these energy storage technologies are reviewed in detail including recent developments, followed by case studies and extensive comparisons. These comparisons include, but are not limited to cost per cycle analyses, levelized cost of energy analyses, and comparisons between performance, transient, and cost characteristics. Here, some key properties analyzed include the rated power, power density, efficiency, lifetime, discharge time, capital costs, and O&M costs.

25 ENERGY STORAGE↗

The application of simulation modeling to the cost and performance ranking of solar thermal power plants

Small solar thermal power systems (up to 10 MWe in size) were tested. The solar thermal power plant ranking study was performed to aid in experiment activity and support decisions for the selection of the most appropriate technological approach. The cost and performance were determined for insolation conditions by utilizing the Solar Energy Simulation computer code (SESII). This model optimizes the size of the collector field and energy storage subsystem for given engine generator and energy transport characteristics. The development of the simulation tool, its operation, and the results achieved from the analysis are discussed.

Rosenberg, L. S.↗

Development of Supervisory Control System for Thermal Energy Distribution System

The integrated energy system (IES) refers to the combination of nuclear energy generation with other energy sources to enable the efficiency and reliability of power generations. To create technologically viable and economically competitive systems, supervisory control strategies are critical for optimizing performance and ensuring stability across different energy generation, transportation, and utilization. This work focuses on the control strategies for the thermal energy distribution system (TEDS), which is a cornerstone of the Dynamic Energy Transport and Integration Laboratory at Idaho National Laboratory. TEDS currently relies on operators to coordinate across different components to manage energy storage and ensure efficiency. This work demonstrates the use of model predictive control (MPC) with surrogate models in determining optimal setpoints for major TEDS components. The capability of MPC-based supervisory control system is evaluated by autonomously matching the power outputs from a Dymola-based TEDS with target heat demands.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Energy Approaches for Mixed-Use Developments in the Front Range Urban Corridor

The primary objective of the document is to present example technical approaches and strategies that planners and developers can reference for all-electric mixed-use developments in the Rocky Mountain Front Range urban corridor that are considering advanced energy performance goals such as high levels of energy efficiency and renewable integration. The strategies are tailored toward the vision for a zero energy, all-electric, district thermal system-connected starter district. In this example, on-site solar generation is emphasized as a strategy that can be combined with electrical and thermal energy storage for enhanced community resilience and demand flexibility. Opportunities for utilizing or adapting these strategies include: sharing with vertical developers for potential integration of strategies into vertical design guidelines; incorporation into Owner Project Requirements (OPRs); providing example strategies to design teams as a starting point for design; informing structure of agenda for a building design charrette; comparing building designs to example strategies at various points in the design process to evaluate design progression. While the technical strategies outlined in this document can help inform the development of guidelines for projects in the Front Range urban corridor, this document does not set requirements for any rating, certification, program, or policy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alkali Metal/Salt Thermal-Energy-Storage Systems

Proposed thermal-energy-storage system based on mixture of alkali metal and one of its halide salts; metal and salt form slurry of two immiscible melts. Use of slurry expected to prevent incrustations of solidified salts on heat-transfer surfaces that occur where salts alone used. Since incrustations impede heat transfer, system performance improved. In system, charging heat-exchanger surface immersed in lower liquid, rich in halide-salt, phase-charge material. Discharging heat exchanger surface immersed in upper liquid, rich in alkali metal.

Phillips, Wayne W.↗

Performance and Durability of Hybrid Fuel Cell Systems for Class-8 Long Haul Trucks

Hybrid fuel cell-battery configurations are investigated that overcome thermal management issues in fuel cell powertrains for heavy-duty Class 8 trucks. The battery is sized so that it has sufficient capacity to provide supplemental power and energy on a hill climb transient at end-of-life. A dynamic load sharing strategy is developed to distribute the power demand between the fuel cell system (FCS) and the energy storage system in a manner that optimizes their lifetimes. The FCS end-of-life is identified as the terminal point beyond which the stack cannot generate the rated power with target power density at 0.7 V and 40 °C ambient temperature. Reaching the target lifetime with a-Pt/C cathode catalyst in one hybrid configuration requires voltage clipping to 813 mV, idle power limited to 50 kW, catalyst overloading to 0.45 mg cm -2 total Pt in anode and cathode, and 44% active membrane area oversizing. The stack and FCS drive cycle efficiencies decrease by 4.2% and 5.4%, respectively, during the electrode lifetime. Further, the FCS performance, durability and cost are compared with the targets of 68% peak efficiency, 0.30 mg cm -2 total Pt loading, 2.5 kW/g PGM Pt group metal (PGM) loading, 750 mW cm -2 power density, 25,000-h lifetime and $80/kW cost.

33 ADVANCED PROPULSION SYSTEMS↗

Tailored Additive Design of Scaffold‐Free Porous Mg for Ultimate Hydrogen Storage

For hydrogen storage materials to become practically viable, comprehensive improvements in key properties—kinetics, thermodynamics, thermal transport, and durability—are crucial. Porous Mg structure has been proposed as a promising strategy due to its high storage capacity and ability to accommodate volume expansion. However, challenges such as sluggish kinetics and structural degradation resulting from instability due to vacant sites still remain. In this study, a tailored design of porous Mg structure with site-specific transition metal dual-doping and structure-reinforced carbon nanotube (CNT)-framework is presented for optimal hydrogen storage. Ti and Ni are strategically deposited on the surface to synergistically enhance hydrogen sorption kinetics by facilitating hydrogen dissociation and diffusion, while CNTs are interpenetrated into 3D Mg structure for improving thermal conductivity and maintaining the porous structure. The resulting composite demonstrates exceptional performance, achieving hydrogen absorption and desorption of 4.8 and 5.8 wt%, respectively, within 10 min with an impressively low activation energy for absorption of 46 kJ mol −1 H 2 . Even after 50 cycles, its capacity and porous structure are well preserved, showing excellent cyclability in comparison with previously reported materials. In conclusion, this delicate design strategy based on a comprehensive understanding of structural and chemical characteristics is key to maximizing the targeted performance.

CNT embedding↗