Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracking Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Parallelized Kalman-Filter-Based Reconstruction of Particle Tracks on Many-Core Processors and GPUs

For over a decade now, physical and energy constraints have limited clock speed improvements in commodity microprocessors. Instead, chipmakers have been pushed into producing lower-power, multi-core processors such as Graphical Processing Units (GPU), ARM CPUs, and Intel MICs. Broad-based efforts from manufacturers and developers have been devoted to making these processors user-friendly enough to perform general computations. However, extracting performance from a larger number of cores, as well as specialized vector or SIMD units, requires special care in algorithm design and code optimization. One of the most computationally challenging problems in high-energy particle experiments is finding and fitting the charged-particle tracks during event reconstruction. This is expected to become by far the dominant problem at the High-Luminosity Large Hadron Collider (HL-LHC), for example. Today the most common track finding methods are those based on the Kalman filter. Experience with Kalman techniques on real tracking detector systems has shown that they are robust and provide high physics performance. This is why they are currently in use at the LHC, both in the trigger and offine. Previously we reported on the significant parallel speedups that resulted from our investigations to adapt Kalman filters to track fitting and track building on Intel Xeon and Xeon Phi. Here, we discuss our progresses toward the understanding of these processors and the new developments to port the Kalman filter to NVIDIA GPUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time Resolved Phonon Spectroscopy, Version 1.0

TRPS code was developed for the project "Time Resolved Phonon Spectroscopy". Routines contained in this piece of software were specially created to model phonon generation and tracking within materials that interact with ionizing radiation, particularly applicable to the modeling of cryogenic radiation detectors for dark matter and neutrino research. These routines were created to link seamlessly with the open source Geant4 framework for the modeling of radiation transport in matter, with the explicit intent of open sourcing them for eventual integration into that code base.

Goett, Johnny↗

Time Resolved Phonon Spectroscopy, Version 1.0

TRPS code was developed for the project "Time Resolved Phonon Spectroscopy". Routines contained in this piece of software were specially created to model phonon generation and tracking within materials that interact with ionizing radiation, particularly applicable to the modeling of cryogenic radiation detectors for dark matter and neutrino research. These routines were created to link seamlessly with the open source Geant4 framework for the modeling of radiation transport in matter, with the explicit intent of open sourcing them for eventual integration into that code base.

Goett, Johnny↗

SU-F-SPS-03: Direct Measurement of Organ Doses Resulting From Head and Cervical Spine Trauma CT Protocols

Purpose: This retrospective study analyzes the exposure history of emergency department (ED) patients undergoing head and cervical spine trauma computed tomography (CT) studies. This study investigated dose levels received by trauma patients and addressed any potential concerns regarding radiation dose issues. Methods: Under proper IRB approval, a cohort of 300 trauma cases of head and cervical spine trauma CT scans received in the ED was studied. The radiological image viewing software of the hospital was used to view patient images and image data. The following parameters were extracted: the imaging history of patients, the reported dose metrics from the scanner including the volumetric CT Dose Index (CTDIvol) and Dose Length Product (DLP). A postmortem subject was scanned using the same scan techniques utilized in a standard clinical head and cervical spine trauma CT protocol with 120 kVp and 280 mAs. The CTDIvol was recorded for the subject and the organ doses were measured using optically stimulated luminescent (OSL) dosimeters. Typical organ doses to the brain, thyroid, lens, salivary glands, and skin, based on the cadaver studies, were then calculated and reported for the cohort. Results: The CTDIvol reported by the CT scanner was 25.5 mGy for the postmortem subject. The average CTDIvol from the patient cohort was 34.1 mGy. From these metrics, typical average organ doses in mGy were found to be: Brain (44.57), Thyroid (33.40), Lens (82.45), Salivary Glands (61.29), Skin (47.50). The imaging history of the cohort showed that on average trauma patients received 26.1 scans over a lifetime. Conclusion: The average number of scans received on average by trauma ED patients shows that radiation doses in trauma patients may be a concern. Available dose tracking software would be helpful to track doses in trauma ED patients, highlighting the importance of minimizing unnecessary scans and keeping doses ALARA.

60 APPLIED LIFE SCIENCES↗

Spin resonance strength calculation through single particle tracking for RHIC

The strengths of spin resonances for the polarized-proton operation in the Relativistic Heavy Ion Collider are currently calculated with the code DEPOL, which numerically integrates through the ring based on an analytical approximate formula. In this article, we test a new way to calculate the spin resonance strengths by performing Fourier transformation to the actual transverse magnetic fields seen by a single particle traveling through the ring. Comparison of calculated spin resonance strengths is made between this method and DEPOL.

43 PARTICLE ACCELERATORS↗

Explicit temperature treatment in Monte Carlo neutron tracking routines - First results

This article discusses the preliminary implementation of the new explicit temperature treatment method to the development version Monte Carlo reactor physics code Serpent 2 and presents the first practical results calculated using the method. The explicit temperature treatment method, as introduced in [1], is a stochastic method for taking the effect of thermal motion into account on-the-fly in a Monte Carlo neutron transport calculation. The method is based on explicit treatment of the motion of target nuclei at collision sites and requires cross sections at 0 K temperature only, regardless of the number of temperatures in the problem geometry. The method includes a novel capability of modelling continuous temperature distributions. Test calculations are performed for two test cases, a PWR pin-cell and a HTGR system. The resulting k{sub eff} and flux spectra are compared to a reference solution calculated using Serpent 1.1.16 with Doppler-broadening rejection correction [2]. The results are in very good agreement with the reference and also the increase in calculation time due to the new method is on acceptable level although not fully insignificant. On the basis of the current study, the explicit treatment method can be considered feasible for practical calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MAESTRO: AN ADAPTIVE LOW MACH NUMBER HYDRODYNAMICS ALGORITHM FOR STELLAR FLOWS

Many astrophysical phenomena are highly subsonic, requiring specialized numerical methods suitable for long-time integration. In a series of earlier papers we described the development of MAESTRO, a low Mach number stellar hydrodynamics code that can be used to simulate long-time, low-speed flows that would be prohibitively expensive to model using traditional compressible codes. MAESTRO is based on an equation set derived using low Mach number asymptotics; this equation set does not explicitly track acoustic waves and thus allows a significant increase in the time step. MAESTRO is suitable for two- and three-dimensional local atmospheric flows as well as three-dimensional full-star flows. Here, we continue the development of MAESTRO by incorporating adaptive mesh refinement (AMR). The primary difference between MAESTRO and other structured grid AMR approaches for incompressible and low Mach number flows is the presence of the time-dependent base state, whose evolution is coupled to the evolution of the full solution. We also describe how to incorporate the expansion of the base state for full-star flows, which involves a novel mapping technique between the one-dimensional base state and the Cartesian grid, as well as a number of overall improvements to the algorithm. We examine the efficiency and accuracy of our adaptive code, and demonstrate that it is suitable for further study of our initial scientific application, the convective phase of Type Ia supernovae.

79 ASTRONOMY AND ASTROPHYSICS↗

High-fidelity Pebble Bed Reactor Depletion Based on Pebble Tracking Transport in Griffin

The pebble tracking transport (PTT) method is a high-fidelity, heterogeneous deterministic transport technique for pebble bed reactor analysis. It discretizes the broad-group neutron transport equation in space and angle with the discontinuous finite element and the discrete ordinates method, and utilizes various solving techniques, including mesh sweeping and diffusion acceleration, to provide pebble- wise reaction rates. This work presents the extension of the PTT method to enable fuel depletion capability in the Griffin code. We discuss the implementation details of the PTT-based high-fidelity depletion where isotope inventory of all individual pebbles is tracked through pre-determined pebble flow paths in the core. The implementation is verified with a generic pebble bed reactor model. Some preliminary equilibrium core results are included. Future works are also discussed.

97 - MATHEMATICS AND COMPUTING↗

SU-G-JeP4-12: Real-Time Organ Motion Monitoring Using Ultrasound and KV Fluoroscopy During Lung SBRT Delivery

Purpose: Real-time ultrasound monitoring during SBRT is advantageous in understanding and identifying motion irregularities which may cause geometric misses. In this work, we propose to utilize real-time ultrasound to track the diaphragm in conjunction with periodical kV fluoroscopy to monitor motion of tumor or landmarks during SBRT delivery. Methods: Transabdominal Ultrasound (TAUS) b-mode images were collected from 10 healthy volunteers using the Clarity Autoscan System (Elekta). The autoscan transducer, which has a center frequency of 5 MHz, was utilized for the scans. The acquired images were contoured using the Clarity Automatic Fusion and Contouring workstation software. Monitoring sessions of 5 minute length were observed and recorded. The position correlation between tumor and diaphragm could be established with periodic kV fluoroscopy periodically acquired during treatment with Elekta XVI. We acquired data using a tissue mimicking ultrasound phantom with embedded spheres placed on a motion stand using ultrasound and kV Fluoroscopy. MIM software was utilized for image fusion. Correlation of diaphragm and target motion was also validated using 4D-MRI and 4D-CBCT. Results: The diaphragm was visualized as a hyperechoic region on the TAUS b-mode images. Volunteer set-up can be adjusted such that TAUS probe will not interfere with treatment beams. A segment of the diaphragm was contoured and selected as our tracking structure. Successful monitoring sessions of the diaphragm were recorded. For some volunteers, diaphragm motion over 2 times larger than the initial motion has been observed during tracking. For the phantom study, we were able to register the 2D kV Fluoroscopy with the US images for position comparison. Conclusion: We demonstrated the feasibility of tracking the diaphragm using real-time ultrasound. Real-time tracking can help in identifying such irregularities in the respiratory motion which is correlated to tumor motion. We also showed the feasibility of acquiring 2D KV Fluoroscopy and registering the images with Ultrasound.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Image Correlation Engine v.3.0

DICe is an open source digital image correlation (DIC) tool intended for use as a module in an external application or as a standalone analysis code. It's primary capability is computing full-field displacements and strains from sequences of digital These images are typically of a material sample undergoing a materials characterization experiment, but DICe is also useful for other applications (for example, trajectory tracking). DICe is machine portable (Windows, Linux and Mac) and can be effectively deployed on a high performance computing platform. Capabilities from DICe can be invoked through a library interface, via source code integration of DICe classes or through a graphical user interface.

Turner, Dan↗

Three-dimensional simulations of ion dynamics in an Electron Cyclotron Resonance Ion Source

We present a three-dimensional simulation of the ion dynamics in an electron cyclotron resonance ion source. Ion trajectories in the min-B field of the source are calculated taking ion-ion and electron-ion collisions into account. The electrons are not tracked but considered as a neutralizing background with a Maxwell-Boltzmann velocity distribution. Some applications of the code are discussed, e.g., the calculated charge-state and phase-space distributions of extracted ion beams and the ionization dynamics in the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose response of alanine detectors irradiated with carbon ion beams

Purpose: The dose response of the alanine detector shows a dependence on particle energy and type when irradiated with ion beams. The purpose of this study is to investigate the response behavior of the alanine detector in clinical carbon ion beams and compare the results to model predictions. Methods: Alanine detectors have been irradiated with carbon ions with an energy range of 89-400 MeV/u. The relative effectiveness of alanine has been measured in this regime. Pristine and spread out Bragg peak depth-dose curves have been measured with alanine dosimeters. The track structure based alanine response model developed by Hansen and Olsen has been implemented in the Monte Carlo code FLUKA and calculations were compared to experimental results. Results: Calculations of the relative effectiveness deviate less than 5% from the measured values for monoenergetic beams. Measured depth-dose curves deviate from predictions in the peak region, most pronounced at the distal edge of the peak. Conclusions: The used model and its implementation show a good overall agreement for quasimonoenergetic measurements. Deviations in depth-dose measurements are mainly attributed to uncertainties of the detector geometry implemented in the Monte Carlo simulations.

60 APPLIED LIFE SCIENCES↗

SU-E-P-07: Evaluation of Productivity Systems for Radiation Therapy

Purpose: Health systems throughout the United States are under increased financial pressure to reduce operating cost. As a result, productivity models developed by third-party consultants are being used to optimize staff to treatment volumes. The purpose of this study was to critically evaluate productivity systems for radiation oncology. Methods: Staffing efficiency was evaluated using multiple productivity models. The first model evaluated staffing levels using equal weighting of procedure codes and hours worked. A second productivity model was developed using hours worked by job class and relative value units for each procedure code. A third model was developed using the measured procedure times extracted from the electronic medical record, which tracks the wait and treatment times for each patient for each treatment fraction. A MatLab program was developed to query and analyze the daily treatment data. A model was then created to determine any theoretical gains in treatment productivity. Results: Productivity was evaluated for six radiation therapy departments operating nine linear accelerators delivering over 40,000 treatment fractions per year. Third party productivity models that do not take into consideration the unique nature of radiation therapy can be counterproductive. For example, other outpatient departments can compress their daily schedule to decrease the worked hours. This approach was tested using the treatment schedule evaluation tool developed as part of this study. It was determined that the maximum possible savings for treatment schedule compression was $32,000 per year per linac. All annual cost savings would be lost if only two patients per year choose to be treated elsewhere because of limited or restricted appointment times. Conclusion: The use of productivity models in radiation therapy can easily result in a loss of treatment revenue that is greater than any potential cost savings in reduced hours worked by staff.

60 APPLIED LIFE SCIENCES↗

Prediction of microstructure formation in laser powder bed fusion process.

The datasets are results analyzing the predicted microstructures in a single track during the laser powder bed fusion additive manufacturing process. They are the outputs by running the opensource code, muMatScale (The code can be cited at: Yuan, Lang, Fattebert, Jean-Luc, and Sabau, Adrian. (2023, August 03). muMatScale. [Computer software]. https://github.com/lang-yuan/muMatScale. https://doi.org/10.11578/dc.20240112.2.) For each set of data, it contains the time-dependent information of Temperature, Fraction Solid, Grain ID, Grain Angle ( crystallographic orientations by Euler angles), and solute Composition. The dataset can be visualized by Paraview (https://www.paraview.org/ ). The 6 datasets are: 1. Baseline_base1_n4e14_dt20: baseline case with bulk nucleation density of 4E+14/m^3, undercooling of 20K, substrate nucleation density of 1.5E+15/m^3 2. Nuc_n4e15_dt20: case with bulk nucleation density of 4E+15/m^3, undercooling of 20K, substrate nucleation density of 1.5E+15/m^3 3. Nuc_n4e15_dt50: case with bulk nucleation density of 4E+15/m^3, undercooling of 50K, substrate nucleation density of 1.5E+15/m^3 4. Nuc_n6e15_dt20: case with bulk nucleation density of 4E+16/m^3, undercooling of 20K, substrate nucleation density of 1.5E+15/m^3 5. Base4_n4e14_dt20: case with bulk nucleation density of 4E+14/m^3, undercooling of 20K, substrate nucleation density of 6.0E+15/m^3 6. Base16_n4e14_dt20: case with bulk nucleation density of 4E+14/m^3, undercooling of 20K, substrate nucleation density of 2.4E+16/m^3

36 MATERIALS SCIENCE↗

Simulations of neutron multiplicity measurements with MCNP-PoliMi.

The heightened focus on nuclear safeguards and accountability has increased the need to develop and verify simulation tools for modeling these applications. The ability to accurately simulate safeguards techniques, such as neutron multiplicity counting, aids in the design and development of future systems. This work focuses on validating the ability of the Monte Carlo code MCNPX-PoliMi to reproduce measured neutron multiplicity results for a highly multiplicative sample. The benchmark experiment for this validation consists of a 4.5-kg sphere of plutonium metal that was moderated by various thicknesses of polyethylene. The detector system was the nPod, which contains a bank of 15 3He detectors. Simulations of the experiments were compared to the actual measurements and several sources of potential bias in the simulation were evaluated. The analysis included the effects of detector dead time, source-detector distance, density, and adjustments made to the value of {nu}-bar in the data libraries. Based on this analysis it was observed that a 1.14% decrease in the evaluated value of {nu}-bar for 239Pu in the ENDF-VII library substantially improved the accuracy of the simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SimTrack: A compact c++ library for particle orbit and spin tracking in accelerators

SimTrack is a compact c++ library of 6-d symplectic element-by-element particle tracking in accelerators originally designed for head-on beam-beam compensation simulation studies in the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. It provides a 6-d symplectic orbit tracking with the 4th order symplectic integration for magnet elements and the 6-d symplectic synchro-beam map for beam-beam interaction. Since its inception in 2009, SimTrack has been intensively used for dynamic aperture calculations with beam-beam interaction for RHIC. Recently, proton spin tracking and electron energy loss due to synchrotron radiation were added. In this article, I will present the code architecture, physics models, and some selected examples of its applications to RHIC and a future electron-ion collider design eRHIC.

43 PARTICLE ACCELERATORS↗

Following the cosmic evolution of pristine gas. I. Implications for Milky Way halo stars

We make use of a new subgrid model of turbulent mixing to accurately follow the cosmological evolution of the first stars, the mixing of their supernova (SN) ejecta, and the impact on the chemical composition of the Galactic Halo. Using the cosmological adaptive mesh refinement code ramses, we implement a model for the pollution of pristine gas as described in Pan et al. Tracking the metallicity of Pop III stars with metallicities below a critical value allows us to account for the fraction of Z<Z{sub crit} stars formed even in regions in which the gas’s average metallicity is well above Z{sub crit}. We demonstrate that such partially mixed regions account for 0.5 to 0.7 of all Pop III stars formed up to z = 5. Additionally, we track the creation and transport of “primordial metals” (PM) generated by Pop III SNe. These neutron-capture deficient metals are taken up by second-generation stars and likely lead to unique abundance signatures characteristic of carbon-enhanced, metal-poor (CEMP-no) stars. As an illustrative example, we associate primordial metals with abundance ratios used by Keller et al. to explain the source of metals in the star SMSS J031300.36-670839.3, finding good agreement with the observed [Fe/H], [C/H], [O/H], and [Mg/Ca] ratios in CEMP-no Milky Way halo stars. Similar future simulations will aid in further constraining the properties of Pop III stars using CEMP observations, as well as improve predictions of the spatial distribution of Pop III stars, as will be explored by the next generation of ground- and space-based telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

Object-Oriented Database for Managing Building Modeling Components and Metadata: Preprint

Building simulation enables users to explore and evaluate multiple building designs. When tools for optimization, parametrics, and uncertainty analysis are combined with analysis engines, the sheer number of discrete simulation datasets makes it difficult to keep track of the inputs. The integrity of the input data is critical to designers, engineers, and researchers for code compliance,validation, and building commissioning long after the simulations are finished. This paper discusses an application that stores inputs needed for building energy modeling in a searchable, indexable, flexible, and scalable database to help address the problem of managing simulation input data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗