Search NASA⌕ Search

SEARCH · Search NASA

Results for “abnormality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

An Inrush Current Limiting Method for Grid-Connected Converters Considering Grid Voltage Disturbances

To support the electric power grid, some grid-connected converters are required to ride through abnormal grid conditions, including voltage disturbances. However, at the moment, when a grid voltage disturbance happens, a large inrush current could be induced due to the large difference between the grid and converter output pulsewidth modulation (PWM) voltages. This inrush current could be more severe in the faster switching SiC-based multilevel converter, which only needs a small filter inductance to meet its normal operation requirements, such as harmonics and peak ripple currents. In this article, a PWM mask method is used to limit the inrush current. With this method, the inrush current can be effectively limited to a preset value and can help the converter ride through grid voltage disturbances. Furthermore, the method is validated through experiments conducted on a single-phase SiC-based five-level converter considering low voltage, high voltage, and phase angle disturbances.

42 ENGINEERING↗

Feedback Optimization of Incentives for Distribution Grid Services

Energy prices and net power injection limitations regulate the operations in distribution grids and typically ensure that operational constraints are met. Nevertheless, unexpected or prolonged abnormal events could undermine the grid's functioning. During contingencies, customers could contribute effectively to sustaining the network by providing services. Herein this paper proposes an incentive mechanism that promotes users' active participation by essentially altering the energy pricing rule. The incentives are modeled via a linear function whose parameters can be computed by the system operator (SO) by solving an optimization problem. Feedback-based optimization algorithms are then proposed to seek optimal incentives by leveraging measurements from the grid, even in the case when the SO does not have a full grid and customer information. Numerical simulations on a standard testbed validate the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Authentication Management for the Data Security of Smart Grid

Bidirectional wireless communication is employed in various smart grid components such as smart meters and control and monitoring applications where security is vital. The Trusted Third Party (TTP) and wireless connectivity between the smart meter and the third party in the key management-based encryption techniques for the smart grid are expected to be totally trustworthy and dependable. In a wired/wireless medium, however, a man-in-the-middle may seek to disrupt, monitor and manipulate the network, or simply execute a replay attack, revealing its vulnerability. Recognizing this, this study presents a novel authentication management (model) comprised of two layer security schema. The first layer implements an efficient novel encryption method for secure data exchange between meters and control center with the help of two partially trusted simple servers (constitutes the TTP). In this setting, one server handles the data encryption between the meter and control center/central database, and the other server administers the random sequence of data transmission. The second layer monitors and verifies exchanged data packets among smart meters. It detects abnormal packets from suspicious sources. To implement this node-to-node authentication, One class support vector machine algorithm is proposed which takes advantages of the location information as well as the data transmission history (node identification, packet size, and data transmission frequency). This schema secures data communication, and imposes a comprehensive privacy throughout the system without considerably extending the complexity of the conventional key management scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of Chebyshev’s Inequality in Online Anomaly Detection Driven by Streaming PMU Data

The day-to-day operation of modern power systems is highly reliant on prompt and adequate situational-awareness. This can be achieved via various system monitoring functions such as anomaly detection, in which static thresholds are commonly utilized to distinguish the normal and the abnormal system states. However, a predetermined static threshold usually lacks the flexibility to adapt to unobserved scenarios. In this paper, we propose two self-adaptive synchrophasor data driven anomaly detection approaches based on Chebyshev’s Inequality. The proposed approaches have been evaluated with Kundur’s 2area system and Mini-WECC system. Experimental results verify that the proposed approaches can dynamically adapt to unprecedented scenarios, and detect anomalous events with lower false alarm rate compared to static threshold based detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordination of Networked Microgrids for Supporting Voltages of Bulk Power Systems

Active distribution system resources have the potential to support the bulk power system (BPS) during abnormal conditions, increasing reliability and resilience of power systems and end-use customers. This paper investigates for the first time the BPS voltage support provided by networked microgrids at the feeder level. A peer-to-peer (P2P) communication control framework is introduced to enable the coordination of multiple microgrids in a mixed ownership environment. This allows the microgrids to run a consensus algorithm (CA) to distributedly determine their own reactive power injections. Thus, the reactive power injection contribution is realized in a fair manner by having the same ratio of reactive power injection to the reactive power headroom for all microgrids. The CA implementation and performance within the P2P network framework are demonstrated on the IEEE 39-bus testcase system with 10 microgrids part of the distribution feeder assumed to be connected to one of the BPS buses.

Vu, Thanh Long↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

aggregates↗

Interconnection of Three Single-Phase Feeders in North America Distribution Systems

This paper proposes a solution for maintaining power balance within all three phases at residential level during islanded mode of operation. Grid abnormalities can lead to isolating the residential microgrid from the main grid, and as a result, distributed generation (DG) units take the full responsibility of supplying local loads. However, in such condition, some phases might face the challenge of meeting local load demand due to the lack of enough power generation, resulting in voltage drop and frequency variation across household loads. In order to resolve this issue, the proposed method in this paper seamlessly interconnects all three single-phase feeders during islanded mode and forms a unified single-phase residential microgrid. Consequently, the load demands in all three phases are met, leading to enhanced voltage and frequency profiles. For this purpose, a seamless transition algorithm is defined which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid accordingly during transitions. Case study results are provided to verify the validity of proposed method.

Pilehvar, Mohsen S.↗

PV-Fed Smart Inverters for Mitigation of Voltage and Frequency Fluctuations in Islanded Microgrids

The presence of low-inertia distributed generation (DG) units makes islanded microgrids vulnerable to voltage and frequency variations. Besides, the considerable difference between the inertia of synchronous-based and inverter-based DGs results in a power imbalance between supply and demand during abnormal conditions. As a result, both voltage and frequency of microgrid ac-bus start oscillating which might have severe consequences such as blackouts. This paper deploys the traditional controller of photovoltaic (PV) units to improve the dynamic behavior of islanded microgrids by suppressing the voltage and frequency fluctuations. To this end, an adaptive piecewise droop (APD) characteristic is proposed and employed in PV units to attain a faster balance between generation and consumption during transients, leading to an enhanced frequency response. Besides, the reactive-power control loop is equipped with a droop characteristic which enables the PV units to inject/absorb reactive power during transients and participate in voltage-profile enhancement of the system. Case study results are presented using PSCAD/EMTDC to confirm the validity of proposed method in improving the dynamics of islanded microgrids.

Pilehvar, Mohsen S.↗

Enhancing Automotive Intrusion Detection Through Multi-Modal Fusion: A CAN FD-LiDAR Approach

As vehicles become smarter and more autonomous, they increasingly depend on advanced sensors and communication technologies to operate securely. However, such growing dependence on technology—whether it’s CAN (Controller Area Network) for internal communication or LiDAR (Light Detection and Ranging) for sensing the world around them—also expands the attack surface for the types of cyber attacks. Traditional intrusion detection systems (IDS) typically monitor these systems in isolation, limiting their ability to detect sophisticated, crosssystem attacks. To address this, we propose a multi-modal fusion approach that combines real-world CAN FD signals (from the HCRL dataset) with LiDAR features (from the nuScenes dataset) to enhance attack detection. Our method employs a twostage ensemble approach. Calibrated XGBoost and LightGBM models initially process CAN FD (Fuzzing Data) and LiDAR data independently, detecting timing anomalies and space abnormalities. They are subsequently logarithmically combined with a logistic regression meta-model along with 17 engineered features capturing cross-modal behavior, prediction conflicts, and nonlinear interactions. This approach achieves an AUC of 0.87 and an F1-score of 0.82, surpassing single-modality baselines and early fusion methods, at merely 2 ms inference latency. Compared with deep learning competitors, it is 3 times more efficient, providing a lightweight, interpretable, and real time solution to automotive cybersecurity.

97 MATHEMATICS AND COMPUTING↗

Trust Model System for the Energy Grid of Things Network Communications

Network communication is crucial in the Energy Grid of Things (EGoT). Without a network connection, the energy grid becomes just a power grid where the energy resources are available to the customer uni-directionally. A mechanism to analyze and optimize the energy usage of the grid can only happen through a medium, a communications network, that enables information exchange between the grid participants and the service provider. Security implementers of EGoT network communication take extraordinary measures to ensure the safety of the energy grid, a critical infrastructure, as well as the safety and privacy of the grid participants. With the dynamic nature of network communication of the EGoT, the information provided by the customer or the service provider can be falsified by a malicious attacker. Therefore, a trust model is necessary to monitor any abnormal activities. This paper describes a distributed trust model system that meets the need of the EGoT. This paper describes methods for evaluating and improving the distributed trust model using standard hypothesis testing metrics such as true positive, false positive, true negative, false negative, equal error rate, and F1 score. Example calculations are shown based on generated sample data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distributed Intrusion Detection System using Semantic-based Rules for SCADA in Smart Grid

Cyber-physical system (CPS) security for the smart grid enables secure communication for the SCADA and wide-area measurement system data. Power utilities world-wide use various SCADA protocols, namely DNP3, Modbus, and IEC 61850, for the data exchanges across substation field devices, remote terminal units (RTUs), and control center applications. Adversaries may exploit compromised SCADA protocols for the reconnaissance, data exfiltration, vulnerability assessment, and injection of stealthy cyberattacks to affect power system operation. In this paper, we propose an efficient algorithm to generate robust rule sets. We integrate the rule sets into an intrusion detection system (IDS), which continuously monitors the DNP3 data traffic at a substation network and detects intrusions and anomalies in real-time. To enable CPS-aware wide-area situational awareness, we integrated the methodology into an open-source distributed-IDS (D-IDS) framework. The D-IDS facilitates central monitoring of the detected anomalies from the geographically distributed substations and to the control center. The proposed algorithm provides an optimal solution to detect network intrusions and abnormal behavior. Different types of IDS rules based on packet payload, packet flow, and time threshold are generated. Further, IDS testing and evaluation is performed with a set of rules in different sequences. The detection time is measured for different IDS rules, and the results are plotted. All the experiments are conducted at Power Cyber Lab, Iowa State University, for multiple power grid models. After successful testing and evaluation, knowledge and implementation are transferred to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GraphCH: A Deep Framework for Assessing Cyber-Human Aspects in Insider Threat Detection

Insider threat is one of the most damaging cyber attacks that could cause the loss of intellectual property and enterprise data security breaches. Action sequence data such as host logs are used to investigate such threats and develop anomaly-based AI detectors. However, insider threat actions are similar to legitimate user activities, causing AI detectors to fail and suffer from high false alarm rates. Therefore, user cyber activity logs are inadequate to fully unfold insider threats. In this study, we adopt human psychological principles of risk-taking and impulsiveness along with host data to assess the influence and usefulness of human behavioral aspects in insider threat detection. Here, we hypothesize that individuals' impulsive and risk-taking behavior correlates with cyberspace activities. To validate our hypothesis, we conducted an IRB-approved study recruiting 35 participants who work in a large U.S. university and collected their cyber and psychological data for 90 days. Host and human-behavioral data analysis and mapping indicate that impulsive and risk-taking users trigger more system errors causing (un)intentional insider threats and are susceptible to attackers' social engineering and cognitive hacking. Utilizing cyber-human aspects, we introduce a Cyber-Human Graph Neural Network (GNN) based framework GraphCH to identify abnormal user behaviors and detect insider threats.

97 MATHEMATICS AND COMPUTING↗

12.5 kV GaN Super-Heterojunction Schottky Barrier Diodes

In this work, we report GaN super-heterojunction Schottky barrier diodes (SHJ-SBDs) with substantially improved performance. Metal-2DEG sidewall n-ohmic contacts were deployed to achieve low contact resistance of 0.75 Ω · mm, avoiding the risk of abnormally high contact resistance caused by inaccurate etch depth control. A pGaN notch formed near the cathode successfully eliminated excessive hole conduction caused by the sidewall n-ohmic contact. Isolation was improved by a high-energy Al implantation step. The resulting SHJ-SBD exhibited a breakdown voltage (BV) of 12.5 kV and a specific ON-resistance of 100.8 mΩ · cm 2 .

42 ENGINEERING↗

Trap Passivation for Reducing On-Resistance and Saturation Voltage in Wafer-Bonded InGaAs-Channel/GaN-Drain Vertical FETs

High frequency and high power are the driving forces behind semiconductor transistor technology. However, conventional devices have the tradeoff of either being high speed or high breakdown—but not both. Wafer-bonded current aperture vertical electron transistors (BAVETs) help eliminate the tradeoff by combining a high-speed III-As channel to a high-breakdown III-N drift region. The device presented herein comprises of an InAlAs gate-barrier/InGaAs channel, wafer-bonded to an InGaN/GaN drift region, with the InGaAs/InGaN interface referred to as the wafer-bonded interface (WBI). The electronic behavior of WBIs is yet less known but necessary in realizing the potential of a BAVET. Herein, strong trap activity at the WBI is shown to be the cause of abnormally high saturation voltage ( V DS_SAT ) in BAVETs. The traps cause unintentional space charge (SC) region in the drain region of the device. This causes a drain resistance, a higher ON-resistance ( R ON ), and a higher V DS_SAT . Here, the challenge is overcome by hydrogen passivation of traps at WBI by using a p-doping for the InAlAs layer, which reduces the trap-charge concentration at the WBI. Consequently, the width of the SC region is reduced and a reduction in V DS_SAT is demonstrated, wherein it reduces from >12 to 5 V.

36 MATERIALS SCIENCE↗

Distributed Coordination of Networked Microgrids for Voltage Support in Bulk Power Grids

The increasing deployment of distributed energy resources (DERs) and microgrids (MGs) in power distribution systems has enabled the adjustment of reactive power consumption as seen at the substation, which can be used to provide voltage support for the bulk power system (BPS). Leveraging this new capability will provide greater resiliency to the power system as a whole. Here, the goal of this paper is to develop and compare three different algorithms, namely distributed optimal power flow, distributed consensus algorithm, and fully decentralized collaborative autonomy for unbalanced distribution systems for microgrid coordination. These algorithms use networked MGs to support the BPS voltage when a contingency at the bulk grid results in abnormally low voltages, which may be a precursor to voltage collapse. Our comparative analysis includes both qualitative and quantitative assessments of the three algorithms and a discussion of the trade-offs between the decentralized and distributed methods in normal and disrupted conditions. Each algorithm was evaluated on the modified IEEE 13-bus system and a real power distribution system at Chattanooga, Tennessee, that encompasses more than 4500 buses. Each algorithms excels differently and may be suited for different scenarios depending on the condition, operations, and priorities of the power and communication systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RX-ADS: Interpretable Anomaly Detection Using Adversarial ML for Electric Vehicle CAN Data

Recent year has brought considerable advancements in Electric Vehicles (EVs) and associated infrastructures/ communications. Intrusion Detection Systems (IDS) are widely deployed for anomaly detection in such critical infrastructures. This paper presents an Interpretable Anomaly Detection System (RX-ADS) for intrusion detection in CAN protocol communication in EVs. Contributions include: 1) window based feature extraction method; 2) deep Autoencoder based anomaly detection method; and 3) adversarial machine learning based explanation generation methodology. The presented approach was tested on two benchmark CAN datasets: OTIDS and Car Hacking. The anomaly detection performance of RX-ADS was compared against the state-of-the-art approaches on these datasets: HIDS and GIDS. The RX-ADS approach presented performance comparable to the HIDS approach (OTIDS dataset) and has outperformed HIDS and GIDS approaches (Car Hacking dataset). Further, the proposed approach was able to generate explanations for detected abnormal behaviors arising from various intrusions. Furthermore, these explanations were later validated by information used by domain experts to detect anomalies. Other advantages of RX-ADS include: 1) the method can be trained on unlabeled data; 2) explanations help experts in understanding anomalies and root course analysis, and also help with AI model debugging and diagnostics, ultimately improving user trust in AI systems.

42 ENGINEERING↗

Characterization of Precipitation-Induced Radon Progeny Deposition Events Using a City-Scale Sensor Network

Networks of radiation detectors provide a platform for real-time radioactive source detection and identification in urban environments. Detection algorithms in these systems must adapt to naturally-occurring changes in background, which requires well-characterized relationships between precipitation events and their corresponding radiological signature. Here, we present a quantitative and qualitative description of rain-induced radon progeny deposition events occurring in Chicago from September 2023 to February 2024. We measure ambient gamma radiation levels, precipitation rate, temperature, pressure, and relative humidity in a network of sensor nodes. For each identified precipitation period, we decompose spectra into static- and radon-associated components as defined by a non-negative matrix factorization (NMF) algorithm. We find a consistent power-law relationship between a precipitation-dependent peak of the radon progeny proxy (RPP) and the peak strength of the radon-associated NMF component for most precipitation events. We conduct a case study of a rainfall period with abnormally high levels of implied radon progeny concentration and describe its temporal and spatial evolution. We hypothesize that this phenomenon is due to the air mass path that intersects a uranium-rich region of Wyoming. Finally, we cluster precipitation events into three distinct categories. One category roughly corresponds to events with deep low-pressure systems and high relative radon concentration, while another is characteristic of light stratiform rain with slightly higher temperatures and intermediate relative radon concentration. The third category appears to contain weak-gradient or lake breeze convection showers with intermittent precipitation and low relative radon concentration. These findings suggest that radiological anomaly detection could be improved by training unique background models corresponding to each category of meteorological event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithm-Based Fault Tolerance for Convolutional Neural Networks

Convolutional neural networks (CNNs) are becoming more and more important for solving challenging and critical problems in many fields. CNN inference applications have been deployed in safety-critical systems, which may suffer from soft errors caused by high-energy particles, high temperature, or abnormal voltage. Of critical importance is ensuring the stability of the CNN inference process against soft errors. Traditional fault tolerance methods are not suitable for CNN inference because error-correcting code is unable to protect computational components, instruction duplication techniques incur high overhead, and existing algorithm-based fault tolerance (ABFT) techniques cannot protect all convolution implementations. In this paper, we focus on how to protect the CNN inference process against soft errors as efficiently as possible, with the following three contributions. (1) We propose several systematic ABFT schemes based on checksum techniques and analyze their fault protection ability and runtime thoroughly. Unlike traditional ABFT based on matrix-matrix multiplication, our schemes support any convolution implementations. (2) We design a novel workflow integrating all the proposed schemes to obtain a high detection/correction ability with limited total runtime overhead. (3) We perform our evaluation using ImageNet with well-known CNN models including AlexNet, VGG-19, ResNet-18, and YOLOv2. Here, experimental results demonstrate that our implementation can handle soft errors with very limited runtime overhead (4%~8% in both error-free and error-injected situations).

97 MATHEMATICS AND COMPUTING↗