Search NASA⌕ Search

SEARCH · Search NASA

Results for “activation temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Cryogenic Selective Surfaces

There are many challenges involved in deep-space exploration, but several of these can be mitigated, or even solved, by the development of a coating that can reject most of the Sun's energy and yet still provide some far-infrared heat emission. Such a coating would allow non-heat-generating objects in space to reach cryogenic temperatures without using an active cooling system. This would be a benefit to deep-space sensors that require low temperatures, such as the James Webb Telescope focal plane array. It would also allow the use of superconductors in deep space, which could lead to magnetic energy storage rings, lossless power delivery, or perhaps a large-volume magnetic shield against galactic cosmic radiation. But perhaps the most significant enablement achieved from such a coating would be the long-term storage in deep space of cryogenic liquids, such as liquid oxygen (LOX).In this report, we review the state of the art in low-temperature coatings and calculate the lowest temperatures each of these can achieve, demonstrating that cryogenic temperatures cannot be reached in deep space in this fashion. We then propose a new coating that does allow coated objects in deep space to achieve the very low temperatures required to store liquid oxygen or nitrogen. These new coatings consist of a moderately thick scattering layer (typically 5 mm) composed of a material transparent to most of the solar spectrum. This layer acts as a scatterer to the Sun's light, performing the same process as titanium dioxide in white paint in the visible. Under that layer, we place a metallic reflector, e.g. silver, to reflect long-wave radiation that is not well scattered. The result is a coating we call "Solar White," in that it scatters most of the solar spectrum just as white paint does for the visible. Our modeling of these coatings has shown that temperatures as low as 50 K can be reached for a coated object fully exposed to sunlight at 1 AU from the Sun and far from the Earth.In the second half of the report we explore a mission application of this coating in order to show that it allows LOX to be carried on a mission to Mars. Heat can reach a LOX tank in five ways: direct radiation from the Sun, scattered or reflected radiation from the Sun off of spacecraft components, radiation from nearby planets or the Moon, radiation from the infrared emission of other parts of the spacecraft, and conduction along support struts and flow lines. We discuss these and sum their total contribution when using a Solar White coating to demonstrate an architecture that allows the transportation of LOX to Mars. After this, other applications of Solar White are listed.

Cryogenic Materials↗

Comparison of catalyst activity

Reactions of highly active catalysts are compared by allowing temperature of catalyst bed, initially at 77 K, to increase slowly; marked deviation in smooth warming curve denotes temperature at which detectable reaction occurs. The lower the temperature at which reaction commences, the more active the catalyst.

Jennings, T. J.↗

Land and Cryosphere Products from Suomi NPP VIIRS: Overview and Status

The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument was launched in October 2011 as part of the Suomi National Polar-Orbiting Partnership (S-NPP). The VIIRS instrument was designed to improve upon the capabilities of the operational Advanced Very High Resolution Radiometer and provide observation continuity with NASA's Earth Observing System's Moderate Resolution Imaging Spectroradiometer (MODIS). Since the VIIRS first-light images were received in November 2011, NASA- and NOAA-funded scientists have been working to evaluate the instrument performance and generate land and cryosphere products to meet the needs of the NOAA operational users and the NASA science community. NOAA's focus has been on refining a suite of operational products known as Environmental Data Records (EDRs), which were developed according to project specifications under the National Polar-Orbiting Environmental Satellite System. The NASA S-NPP Science Team has focused on evaluating the EDRs for science use, developing and testing additional products to meet science data needs, and providing MODIS data product continuity. This paper presents to-date findings of the NASA Science Team's evaluation of the VIIRS land and cryosphere EDRs, specifically Surface Reflectance, Land Surface Temperature, Surface Albedo, Vegetation Indices, Surface Type, Active Fires, Snow Cover, Ice Surface Temperature, and Sea Ice Characterization. The study concludes that, for MODIS data product continuity and earth system science, an enhanced suite of land and cryosphere products and associated data system capabilities are needed beyond the EDRs currently available from the VIIRS.

Land Surface↗

Land, Cryosphere, and Nighttime Environmental Products from Suomi NPP VIIRS: Overview and Status

The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument was launched in October 2011 as part of the Suomi National Polar-orbiting Partnership (S-NPP: http://npp.gsfc.nasa.gov/). VIIRS was designed to improve upon the capabilities of the operational Advanced Very High Resolution Radiometer (AVHRR) and provide observation continuity with NASA's Earth Observing System's (EOS) Moderate Resolution Imaging Spectroradiometer (MODIS). Since the VIIRS first-light images were received in November 2011, NASA and NOAA funded scientists have been working to evaluate the instrument performance and derived products to meet the needs of the NOAA operational users and the NASA science community. NOAA's focus has been on refining a suite of operational products known as Environmental Data Records (EDRs), which were developed according to project specifications under the former National Polar-orbiting Environmental Satellite System (NPOESS). The NASA S-NPP Science Team has focused on evaluating the EDRs for science use, developing and testing additional products to meet science data needs and providing MODIS data product continuity. This paper will present to-date findings of the NASA Science Team's evaluation of the VIIRS Land and Cryosphere EDRs, specifically Surface Reflectance, Land Surface Temperature, Surface Albedo, Vegetation Indices, Surface Type, Active Fires, Snow Cover, Ice Surface Temperature, and Sea Ice Characterization (http://viirsland.gsfc.nasa.gov/index.html). The paper will also discuss new capabilities being developed at NASA's Land Product Evaluation and Test Element (http://landweb.nascom.nasa.gov/NPP_QA/); including downstream data and products derived from the VIIRS Day/Night Band (DNB).

land cover land use↗

Effect of surface condition on the formation of solid lubricating films at high temperatures

Solid films were produced on active metal or ceramic surfaces using lubricants (such as tricresyl phosphate) delivered as a vapor at high temperatures, and the lubricity of these deposits under different dynamic wear conditions was investigated. A method is described for chemically activating ceramic surfaces resulting in a surface that could promote the formation of lubricating polymeric derivative of TCP. Experiments were carried out to evaluate the wear characteristics of unlubricated cast iron and of Sialon ceramic at 25 and 280 C, and lubricated with a vapor of TCP at 280 C. It is shown that continuous vapor phase lubrication of chemically treated Sialon reduced its coefficient of friction from 0.7 to less than 0.1.

Hanyaloglu, Bengi↗

Affordable Manufacturing Technologies Being Developed for Actively Cooled Ceramic Components

Efforts to improve the performance of modern gas turbine engines have imposed increasing service temperature demands on structural materials. Through active cooling, the useful temperature range of nickel-base superalloys in current gas turbine engines has been extended, but the margin for further improvement appears modest. Because of their low density, high-temperature strength, and high thermal conductivity, in situ toughened silicon nitride ceramics have received a great deal of attention for cooled structures. However, high processing costs have proven to be a major obstacle to their widespread application. Advanced rapid prototyping technology, which is developing rapidly, offers the possibility of an affordable manufacturing approach.

Bhatt, Ramakrishna T.↗

The analysis of XUV emission lines

A technique for analyzing measurements of XUV spectral-line intensities is described. Application of the technique to OSO-4 and OSO-6 spectra indicates that the mean coronal temperature is 2.1 million K in typical active solar regions and that the mean coronal temperature in typical quiet regions ranges from 1.5 to 2.1 million K. One active-region spectrum shows evidence for substantial quantities of coronal material with temperatures between 2 and 3.5 million K. Measurements from limb spectra show evidence that (1) coronal abundances of N and O are low relative to heavier elements; or (2) that the ionization-equilibrium calculations used may contain systematic errors; or (3) that the XUV intensity measurements may be incorrectly calibrated.

Withbroe, G. L.↗

Silicon crystal as a low work function collector

A test vehicle with a low work function collector which can be incorporated in a thermionic converter was constructed from standard vacuum components including an ultrahigh vacuum ion pump. The collector assembly was fabricated by diffusion bonding a (100) oriented silicon single crystal to a molybdenum block. The silicon surface was treated with cesium and oxygen to produce an NEA-type condition and the results were tested by photoemission and work function measurements. An n-type silicon collector was successfully activated to a work function of 1.0 eV, which was verified by photoemission spectral yield measurements. The stability test of an activated surface at elevated temperatures was conducted in the range from room temperature to 619 K, which was slightly lower than the designed collector temperature of 700 K. The work function measurements clearly demonstrated that the behavior of cesium replenishment on the activated Si surface was similar in nature to that of a metallic surface; that is, the loss of cesium by thermal desorption could be compensated by maintaining an adequate vapor pressure of cesium.

Chang, K. H.↗

Operational Characteristics of Four Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 11 male and 10 female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.21 C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a URI Inc. Biolog ambulatory monitor. In general, the male and female subjects' rectal and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx.0.2 - 0.5 C, for both men and women wearing any of the four different garments. The corresponding car temperatures were significantly (P<0.05) decreased approx.0.2 - 0.3 C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods. These results show that all vest configurations elicit a similar thermal response in both male and female subject groups. However, subject population variance was rather large and may have masked differences between the vests. One vest may prove more effective than another for a given individual, and experience is the only means of determining this.

Ku, Yu-Tsuan E.↗

Biomedical Application of Aerospace Personal Cooling Systems

Personal thermoregulatory systems which are used by astronauts to alleviate thermal stress during extravehicular activity have been applied to the therapeutic management of multiple sclerosis. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 10 male and female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.22C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. In general, the male and female subjects' oral and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx. 0.2 - 0.5C, for both men and women wearing any of the four different garments. The corresponding ear temperatures were significantly (P<0.05) decreased approx.0.2 - 0.4C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods.

Ku, Yu-Tsuan E.↗

Revealing a Pathway for Low-Temperature Recrystallization in Germanium

Thermally activated annealing in semiconductors faces inherent limitations, such as dopant diffusion. Here, a nonthermal pathway is demonstrated for a complete structural restoration in predamaged germanium via ionization-induced recovery. By combining experiments and modeling, this study reveals that the energy transfer of only 2.4 keV nm −1 from incident ions to target electrons can effectively annihilate pre-existing defects and restore the original crystalline structure at room temperature. Moreover, it is revealed that the irradiation-induced crystalline-to-amorphous (c/a) transformation in Ge is reversible, a phenomenon previously considered unattainable without additional thermal energy imposed during irradiation. For partially damaged Ge, the overall damage fraction decreases exponentially with increasing fluence. Surprisingly, the recovery process in preamorphized Ge starts with defect recovery outside the amorphous layer and a shrinkage of the amorphous thickness. After this initial stage, the remaining damage decreases slowly with increasing fluence, but full restoration of the pristine state is not achieved. These differences in recovery are interpreted in the framework of structural differences in the initial defective layers that affect recovery kinetics. This study provides new insights on reversing the c/a transformation in Ge using highly-ionizing irradiation and has broad implications across materials science, radiation damage mitigation, and fabrication of Ge-based devices.

athermal recovery↗

Characterization and Evolution of the Swift X-ray Telescope Instrumental Background

The X-ray telescope (XRT) on board the Swift Gamma Ray Burst Explorer has successfully operated since the spacecraft launch on 20 November 2004, automatically locating GRB afterglows, measuring their spectra and lightcurves and performing observations of high-energy sources. In this work we investigate the properties of the instrumental background, focusing on its dynamic behavior on both long and short timescales. The operational temperature of the CCD is the main factor that influences the XRT background level. After the failure of the Swift active on-board temperature control system, the XRT detector now operates at a temperature range between -75C and -45C thanks to a passive cooling Heat Rejection System. We report on the long-term effects on the background caused by radiation, consisting mainly of proton irradiation in Swift's low Earth orbit and on the short-term effects of transits through the South Atlantic Anomaly (SAA), which expose the detector to periods of intense proton flux. We have determined the fraction of the detector background that is due to the internal, instrumental background and the part that is due to unresolved astrophysical sources (the cosmic X-ray background) by investigating the degree of vignetting of the measured background and comparing it to the expected value from calibration data.

Hill, Joanne↗

Effect of prolonged hypodynamia on certain physiological functions in dogs

The behavior of 20 dogs whose mobility was restricted was experimentally investigated. Their reactions to hypodynamia were either active behavior or progressive general depression and increased muscular weakness. Arterial pressure, pressor sinocarotid reflex valve, body weight, pulse rate, body temperature, and plasma cholinesterase activity were monitered for 28 days. Results are reported.

Yaremenko, B. R.↗

US Tropical Cyclone Activity in the 2030s Based on Projected Changes in Tropical Sea-Surface Temperature

We use a statistical tropical cyclone (TC) model, the North Atlantic Stochastic Hurricane Model (NASHM), in combination with sea-surface temperature (SST) projections from climate models, to estimate regional changes in US TC activity into the 2030s. NASHM is trained on historical variations in TC characteristics with two SST indices: global-tropical mean SST and the difference between tropical North-Atlantic (NA) SST and the rest of the global tropics, often referred to as “relative SST.” Testing confirms the model’s ability to reproduce historical US TC activity, as well as to make skillful predictions. When NASHM is driven by SST projections into the 2030s, overall NA annual TC counts increase, and the fractional increase is the greatest at the highest wind intensities. However, an eastward anomaly in mean TC tracks and an eastward shift in TC formation region result in a geographically-varied signal in US coastal activity. Florida’s Gulf coast is projected to see significant increases in TC activity, compared to the long-term historical mean, and these increases are fractionally greatest at the highest intensities. By contrast, the northwestern US Gulf and the US East Coast will see little change.

tropical cyclone (TC) model↗

On the possibility of negative activation energies in bimolecular reactions

The temperature dependence of the rate constants for model reacting systems was studied to understand some recent experimental measurements which imply the existence of negative activation energies. A collision theory model and classical trajectory calculations are used to demonstrate that the reaction probability can vary inversely with collision energy for bimolecular reactions occurring on attractive potential energy surfaces. However, this is not a sufficient condition to ensure that the rate constant has a negative temperature dependence. On the basis of these calculations, it seems unlikely that a true bimolecular reaction between neutral molecules will have a negative activation energy.

Jaffe, R. L.↗

Thermal Regulation of CO 2 Activation Pathways via Interfacial Water Restructuring Enables Ampere-Level, Near-Unity CO Electrosynthesis

Electrochemical reduction of CO 2 to CO is a key step in carbon utilization technologies, yet maintaining high CO selectivity under elevated temperatures relevant to industrial membrane-electrode-assembly (MEA) electrolyzers remains challenging due to the competing hydrogen evolution reaction (HER). Additionally, the temperature dependence of CO selectivity on Cu-based catalysts has remained largely unexplored. Here, we demonstrate that incorporating atomic In or Sn into Cu fundamentally reshapes the selectivity of Cu catalysts at elevated temperatures. Dilute alloy catalysts, In 1 Cu and Sn 1 Cu, achieve >95% FE of CO over a broad current-density window (0.1−1.1 A cm −2 ) at 60 °C in MEA electrolyzers, far exceeding their performance at ambient temperature. In situ attenuated total reflection surface-enhanced infrared absorption spectroscopy suggests that elevating temperature depletes interfacial water activity, which favors a shift in CO 2 activation from a proton-coupled *COOH pathway toward an electron-driven *COO − -associated pathway, while also suppressing HER and CO hydrogenation. In contrast, benchmark CO-selective catalysts such as Ag exhibit minimal temperature-induced changes in CO production at 20−60 °C. These findings identify temperature as an unavoidable yet previously underutilized operating parameter in MEA electrolyzers for high-rate, selective CO production on Cubased catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗