Search NASA⌕ Search

SEARCH · Search NASA

Results for “analysis and visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Gibbs Energy Minimization Model for Solvent Extraction with Application to Rare-Earths Recovery

The emergence of technologies in which rare-earth elements provide critical functionality has increased the demand for these materials, with important implications for supply security. Recycling provides an option for mitigating supply risk and for creating economic value from the resale of recovered materials. While solvent extraction is a proven technology for rare-earth recovery and separation, its application often requires extensive trial-and-error experimentation to estimate parameter values and determine experimental design configurations. We describe a modeling strategy based on Gibbs energy minimization that incorporates parameter estimation for required thermodynamic properties as well as process design for solvent extraction and illustrate its applicability to rare earths separation. Visualization analysis during parameter estimation revealed a linear relationship between the standard enthalpies of the extractant and respective organo-metal complexes, analogous to the additivity principle for predicting molar volumes of organic compounds. Establishing this relationship reduced the size of the parameter estimation problem and yielded good agreement between model predictions and reported equilibrium extraction data, validating the property estimates for the organic phase species. Design exploration and optimization results map the space of feasible solvent extraction column configurations and identify the set of optimal design parameter values that meet recovery and purity targets.

Critical materials↗

Modified Energy Span Analysis of Catalytic Parallel Pathways and Selectivity

Mechanistic modeling provides vital insights into catalytic reactions. To analyze complex reaction networks with parallel pathways, we leverage the graph theory approach of the Energy Span Model (ESM) to develop a modified energy span analysis (MESA). A new method of cycle plots is proposed to perform reaction pathways analysis visually. We demonstrate this method on two published models: one describing carbon monoxide oxidation and the other simulating ethylene conversion to propanal via hydroformylation or ethane via hydrogenation. Fundamental insights explain kinetic observables, such as a reactant’s negative reaction order. General principles are revealed, such as rate-determining surface species being outside the primary reaction flux cycle and pathway selectivity being a purely kinetic property when reaction conditions are not near equilibrium. Lastly, we demonstrate MESA’s consistency with published microkinetic modeling results, highlighting this technique’s extension of the ESM to heterogeneous catalysts using collision theory to describe adsorption steps and concentration effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of Valine 464 in the Flavin Oxidation Reaction Catalyzed by Choline Oxidase

The oxidation of reduced flavin cofactors by oxygen is a very important reaction that is central to the chemical versatility of hundreds of flavoproteins classified as monooxygenases and oxidases. These enzymes are characterized by bimolecular rate constants {ge} 10{sup 5} M{sup -1} s{sup -1} and produce water and hydrogen peroxide, respectively. A hydrophobic cavity close to the reactive flavin C(4a) atom has been previously identified in the 3D structure of monooxygenases but not in flavoprotein oxidases. In the present study, we have investigated by X-ray crystallography, mutagenesis, steady-state, and rapid reaction approaches the role of Val464, which is <6 {angstrom} from the flavin C(4a) atom in choline oxidase. The 3D structure of the Val464Ala enzyme was essentially identical to that of the wild-type enzyme as shown by X-ray crystallography. Time-resolved anaerobic substrate reduction of the enzymes showed that replacement of Val464 with alanine or threonine did not affect the reductive half-reaction. Steady-state and rapid kinetics as well as enzyme-monitored turnovers indicated that the oxidative half-reaction in the Ala464 and Thr464 enzymes was decreased by 50-fold with respect to the wild-type enzyme. We propose that the side chain of Val464 in choline oxidase provides a nonpolar site that is required to guide oxygen in proximity of the C(4a) atom of the flavin, where it will subsequently react via electrostatic catalysis. Visual analysis of available structures suggests that analogous nonpolar sites are likely present in most flavoprotein oxidases. Mechanistic considerations provide rationalization for the differences between sites in monooxygenases and oxidases.

59 BASIC BIOLOGICAL SCIENCES↗

Nontemplated Approach to Tuning the Spectral Propertiesof Cyanine-Based Fluorescent NanoGUMBOS

Template-free controlled aggregation and spectral properties in fluorescent organic nanoparticles (FONs) is highly desirable for various applications.Herein, we report a nontemplated method for controlling the aggregation in near-infrared (NIR) cyanine-based nanoparticles derived from a group of uniformmaterials based on organic salts (GUMBOS). Cationic heptamethine cyanine dye 1,10,3,3,30,30-hexamethylindotricarbocyanine (HMT) was coupled with five different anions, viz., [NTf2 -], [BETI-], [TFPB-], [AOT-], and [TFP4B-], by an ion-exchange method to obtain the respective GUMBOS. The nanoGUMBOS obtained via a reprecipitation method were primarily amorphous and spherical (30-100 nm) as suggested by selected area electron diffraction (SAED) and transmission electron microscopy (TEM). The formation of tunable self-assemblies within the nanoGUMBOS was characterized using absorption and fluorescence spectroscopy in conjunction with molecular dynamics simulations. Counterion-controlled spectral properties observed in the nanoGUMBOS were attributed to variations in J/H ratios with different anions. Association with the [AOT-] anion afforded predominant J aggregation enabling the highest fluorescence intensity, whereas [TFP4B-] disabled the fluorescence due to predominantHaggregation in the nanoparticles. Analyses of the stacking angle of the cations based on molecular dynamic simulation results in [HMT][NTf2], [HMT][BETI], and [HMT][AOT] dispersed in water and a visual analysis of the representative simulation snapshots also imply that the type of aggregation was controlled through the counterion associated with the dye cation.

Das, Susmita↗

GNPS Dashboard: collaborative exploration of mass spectrometry data in the web browser

Access to web-based platforms has enabled scientists to perform research remotely. A critical aspect of mass spectrometry data analysis is the inspection, analysis, and visualization of the raw data to validate data quality and confirm statistical observations. We developed the GNPS Dashboard, a web-based data visualization tool, to facilitate synchronous collaborative inspection, visualization, and analysis of private and public mass spectrometry data remotely.

59 BASIC BIOLOGICAL SCIENCES↗

Induced liquid-crystalline ordering in solutions of stiff and flexible amphiphilic macromolecules: Effect of mixture composition

Impact of mixture composition on self-organization in concentrated solutions of stiff helical and flexible macromolecules was studied by means of molecular dynamics simulation. The macromolecules were composed of identical amphiphilic monomer units but a fraction f of macromolecules had stiff helical backbones and the remaining chains were flexible. In poor solvents the compacted flexible macromolecules coexist with bundles or filament clusters from few intertwined stiff helical macromolecules. The increase of relative content f of helical macromolecules leads to increase of the length of helical clusters, to alignment of clusters with each other, and then to liquid-crystalline-like ordering along a single direction. The formation of filament clusters causes segregation of helical and flexible macromolecules and the alignment of the filaments induces effective liquid-like ordering of flexible macromolecules. A visual analysis and calculation of order parameter relaying the anisotropy of diffraction allow concluding that transition from disordered to liquid-crystalline state proceeds sharply at relatively low content of stiff components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE BULK OF THE BLACK HOLE GROWTH SINCE z {approx} 1 OCCURS IN A SECULAR UNIVERSE: NO MAJOR MERGER-AGN CONNECTION

What is the relevance of major mergers and interactions as triggering mechanisms for active galactic nuclei (AGNs) activity? To answer this long-standing question, we analyze 140 XMM-Newton-selected AGN host galaxies and a matched control sample of 1264 inactive galaxies over z {approx} 0.3-1.0 and M{sub *} < 10{sup 11.7} M{sub sun} with high-resolution Hubble Space Telescope/Advanced Camera for Surveys imaging from the COSMOS field. The visual analysis of their morphologies by 10 independent human classifiers yields a measure of the fraction of distorted morphologies in the AGN and control samples, i.e., quantifying the signature of recent mergers which might potentially be responsible for fueling/triggering the AGN. We find that (1) the vast majority (>85%) of the AGN host galaxies do not show strong distortions and (2) there is no significant difference in the distortion fractions between active and inactive galaxies. Our findings provide the best direct evidence that, since z {approx} 1, the bulk of black hole (BH) accretion has not been triggered by major galaxy mergers, therefore arguing that the alternative mechanisms, i.e., internal secular processes and minor interactions, are the leading triggers for the episodes of major BH growth. We also exclude an alternative interpretation of our results: a substantial time lag between merging and the observability of the AGN phase could wash out the most significant merging signatures, explaining the lack of enhancement of strong distortions on the AGN hosts. We show that this alternative scenario is unlikely due to (1) recent major mergers being ruled out for the majority of sources due to the high fraction of disk-hosted AGNs, (2) the lack of a significant X-ray signal in merging inactive galaxies as a signature of a potential buried AGN, and (3) the low levels of soft X-ray obscuration for AGNs hosted by interacting galaxies, in contrast to model predictions.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep learning for in situ data compression of large turbulent flow simulations

As the size of turbulent flow simulations continues to grow, in situ data compression is becoming increasingly important for visualization, analysis, and restart checkpointing. For these applications, single-pass compression techniques with low computational and communication overhead are crucial. In this paper we present a deep-learning approach to in situ compression using an autoencoder architecture that is customized for three-dimensional turbulent flows and is well suited for contemporary heterogeneous computing resources. The autoencoder is compared against a recently introduced randomized single-pass singular value decomposition (SVD) for three different canonical turbulent flows: decaying homogeneous isotropic turbulence, a Taylor-Green vortex, and turbulent channel flow. Our proposed fully convolutional autoencoder architecture compresses turbulent flow snapshots by a factor of 64 with a single pass, allows for arbitrarily sized input fields, is cheaper to compute than the randomized single-pass SVD for typical simulation sizes, performs well on unseen flow configurations, and has been made publicly available. The results reported here show that the autoencoder dramatically outperforms a randomized single-pass SVD with similar compression ratio and yields comparable performance to a higher-rank decomposition with an order of magnitude less compression in regard to preserving a number of important statistical quantities such as turbulent kinetic energy, enstrophy, and Reynolds stresses.

97 MATHEMATICS AND COMPUTING↗

Driving Next-Generation Workflows from the Data Plane

We observe the emergence of a new generation of scientific workflows that process data produced at a sustained rate by scientific instruments and large scale numerical simulations. This data is consumed by multiple analysis, visualization, or Machine Learning components not only to enable inference and justify the scientific program, but also to monitor and steer the evolution of these experiments. In such workflows, moving intermediate data efficiently is key to performance, more than efficiently scheduling computational tasks. However, most traditional workflow management systems focus on optimizing task scheduling and then deal with data management, assuming a “move little, compute for long” model, which makes them unfit to the efficient management of this new generation of workflows. Therefore, we advocate for a new way to manage scientific workflows. We propose to consider an efficiently and independently managed data plane that can store and stream data. Workflows compute components, in the application plane can then interact with the data plane, abstracted from complexities of data management. Then, the role of a workflow management system would become that of a control plane that allows users to connect services together to execute the workflow and manages connections between the application and data planes. In this position paper, we characterize several next-generation workflow motifs and describe how their interaction with the data plane is a challenge to traditional workflow management systems. Then, we express a set of requirements that a workflow management system should meet to efficiently manage next-generation workflows at different scales. Based on these requirements, we expose our vision of driving next-generation workflows from the data plane and list remaining open challenges.

Suter, Fred↗

Visual Data-Analytics of Large-Scale Parallel Discrete-Event Simulations

Parallel discrete-event simulation (PDES) is an important tool in the codesign of extreme-scale systems because PDES provides a cost-effective way to evaluate designs of highperformance computing systems. Optimistic synchronization algorithms for PDES, such as Time Warp, allow events to be processed without global synchronization among the processing elements. A rollback mechanism is provided when events are processed out of timestamp order. Although optimistic synchronization protocols enable the scalability of large-scale PDES, the performance of the simulations must be tuned to reduce the number of rollbacks and provide an improved simulation runtime. To enable efficient large-scale optimistic simulations, one has to gain insight into the factors that affect the rollback behavior and simulation performance. We developed a tool for ROSS model developers that gives them detailed metrics on the performance of their large-scale optimistic simulations at varying levels of simulation granularity. Model developers can use this information for parameter tuning of optimistic simulations in order to achieve better runtime and fewer rollbacks. In this work, we instrument the ROSS optimistic PDES framework to gather detailed statistics about the simulation engine. We have also developed an interactive visualization interface that uses the data collected by the ROSS instrumentation to understand the underlying behavior of the simulation engine. The interface connects real time to virtual time in the simulation and provides the ability to view simulation data at different granularities. We demonstrate the usefulness of our framework by performing a visual analysis of the dragonfly network topology model provided by the CODES simulation framework built on top of ROSS. The instrumentation needs to minimize overhead in order to accurately collect data about the simulation performance. To ensure that the instrumentation does not introduce unnecessary overhead, we perform a scaling study that compares instrumented ROSS simulations with their noninstrumented counterparts in order to determine the amount of perturbation when running at different simulation scales.

Ross, Caitlin↗

A Practical Solver for Scalar Data Topological Simplification

This paper presents a practical approach for the optimization of topological simplification, a central pre-processing step for the analysis and visualization of scalar data. Given an input scalar field f and a set of “signal” persistence pairs to maintain, our approaches produces an output field g that is close to f and which optimizes (i) the cancellation of “non-signal” pairs, while (ii) preserving the “signal” pairs. In contrast to pre-existing simplification algorithms, our approach is not restricted to persistence pairs involving extrema and can thus address a larger class of topological features, in particular saddle pairs in three-dimensional scalar data. Our approach leverages recent generic persistence optimization frameworks and extends them with tailored accelerations specific to the problem of topological simplification. Extensive experiments report substantial accelerations over these frameworks, thereby making topological simplification optimization practical for real-life datasets. Our approach enables a direct visualization and analysis of the topologically simplified data, e.g., via isosurfaces of simplified topology (fewer components and handles). We apply our approach to the extraction of prominent filament structures in three-dimensional data. Specifically, we show that our pre-simplification of the data leads to practical improvements over standard topological techniques for removing filament loops. Here, we also show how our approach can be used to repair genus defects in surface processing. Finally, we provide a C++ implementation for reproducibility purposes.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-09: Image Quality Comparison and Dose Quantification for 2.5 MV

Purpose: To compare the image quality of the 2.5MV imaging beam (2.5X-IMB) to that of a 6MV beam and to quantify the imaging dose of a 2.5X-IMB for constancy as specified by AAPM TG-142 Methods: The image quality of the 2.5X-IMB was compared to the 6MV imaging beam using the SNC ImagePro MV-QA phantom and the Varian supplied Las Vegas phantom (LVP). High resolution (1280×1280×16, 2 frames at 1.5MU/frame) and low resolution (640×640×16, 2 frames at 0.75MU/frame) images were compared for each phantom. MV-QA phantom images were evaluated quantitatively, and the LVP images were evaluated qualitatively. The imaging dose for 2.5X-IMB was quantified using the procedure outlined in TG51. PTWCC13-31013 chambers were used to measure a percent depth dose (PDD) curve for the 2.5X-IMB. All the factors described in TG51 were calculated using the 2.5X-IMB and a PTW30013 farmer chamber. Results: A comparison between 2.5X-IMB and 6MV image quality was performed both visually and with DoseLab software. The optimal window and level were set for each image of the LVP by the user. Visual inspection showed greater contrast resolution with the 2.5MV beam, but no significant difference with the change in imaging resolution. DoseLab reported similar spatial resolutions between the two energies, but the contrast-to-noise ratio (CNR) was greater for 2.5MV. The PDDx(10cm) for a 10x10cm2 field was measured to be 51.5%. Although this PDD value is off the scale of Figure 4 in TG51, the trend of the curve corresponding to the PTW31003 (equivalent) chamber led to an approximate kQ value of 1.00. Conclusion: When compared to 6MV imaging, 2.5X-IMB results in a better CNR. At low resolution, the DoseLab results for the two energies are comparable, but visual analysis favors the 2.5X-IMB images. Imaging dose was quantified for the 2.5X-IMB after following the TG51 methodology with appropriate approximations.

60 APPLIED LIFE SCIENCES↗

SU-E-J-42: Evaluation of Fiducial Markers for Ultrasound and X-Ray Images Used for Motion Tracking in Pancreas SBRT

Purpose Ultrasound tracking of target motion relies on visibility of vascular and/or anatomical landmark. However this is challenging when the target is located far from vascular structures or in organs that lack ultrasound landmark structure, such as in the case of pancreas cancer. The purpose of this study is to evaluate visibility, artifacts and distortions of fusion coils and solid gold markers in ultrasound, CT, CBCT and kV images to identify markers suitable for real-time ultrasound tracking of tumor motion in SBRT pancreas treatment. Methods Two fusion coils (1mm × 5mm and 1mm × 10 mm) and a solid gold marker (0.8mm × 10mm) were embedded in a tissue–like ultrasound phantom. The phantom (5cm × 12cm × 20cm) was prepared using water, gelatin and psyllium-hydrophilic-mucilloid fiber. Psylliumhydrophilic mucilloid acts as scattering medium to produce echo texture that simulates sonographic appearance of human tissue in ultrasound images while maintaining electron density close to that of water in CT images. Ultrasound images were acquired using 3D-ultrasound system with markers embedded at 5, 10 and 15mm depth from phantom surface. CT images were acquired using Philips Big Bore CT while CBCT and kV images were acquired with XVI-system (Elexta). Visual analysis was performed to compare visibility of the markers and visibility score (1 to 3) were assigned. Results All markers embedded at various depths are clearly visible (score of 3) in ultrasound images. Good visibility of all markers is observed in CT, CBCT and kV images. The degree of artifact produced by the markers in CT and CBCT images are indistinguishable. No distortion is observed in images from any modalities. Conclusion All markers are visible in images across all modalities in this homogenous tissue-like phantom. Human subject data is necessary to confirm the marker type suitable for real-time ultrasound tracking of tumor motion in SBRT pancreas treatment.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-T-02: Vernier Picket Fence Test: A Non-Imaging Method to Localize the Radiation Isocenter with Submillimeter Accuracy

Purpose: The purpose of this study is to propose a new non-imaging method to localize the radiation isocenter with submillimeter accuracy. Methods: The Vernier picket fence (VPF) is a multileaf collimator (MLC) picket fence sequence in which the fence spacing is 1/N smaller than the detector spacing of the QA phantom, where N is the magnification factor, typically set to 10 or 20. Similar to reading a Vernier caliper, the user can easily achieve the resolution of 1/N of the detector spacing by visually inspecting the maximum signal. To achieve higher accuracy, a Gaussian model was used to interpolate the peak position, which can fall between adjacent detectors. In two separate tests, precise MLC offsets and imprecise couch offsets were applied to a 2D detector array (MapCheck, Sun Nuclear Corp., Melbourne, Florida) to introduce setup errors. Two vertical VPF fields were delivered with collimator angles at 0° and 90° to detect the lateral and longitudinal setup errors, respectively. For a rotational QA phantom, an additional lateral VPF field is needed to detect the vertical setup error for three-dimensional capabilities. Results: With N set to 20 and a detector spacing of 5 mm for MapCheck, the resolution of the VPF’s visual analysis is 0.25 mm. With the Gaussian interpretation, the VPF can achieve an accuracy of 0.02 mm, as shown by the MLC offset test. The couch offset test measured the couch hysteresis and demonstrated that the setup error detected by the VPF differed from the ExacTrac™ (Brainlab AG, Feldkirchen, Germany) optical tracking by 0.055 mm in the lateral direction and 0.041 mm in the longitudinal direction on average. The VPF was also shown to be feasible in the vertical direction as well. Conclusion: This study verified the VPF as a non-imaging method to localize the radiation isocenter with submillimeter accuracy. Funding is in part by the Portland Chapter of the Achievement Rewards for College Scientists. The content is solely the responsibility of the authors, and does not necessarily represent the official views of the sponsors. The authors declare no conflict of interest.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-16: Vulnerabilities in the Gamma Metric

Purpose: To explore vulnerabilities in the gamma index metric that undermine its wide use as a radiation therapy quality assurance tool. Methods: 2D test field pairs (images) are created specifically to achieve high gamma passing rates, but to also include gross errors by exploiting the distance-to-agreement and percent-passing components of the metric. The first set has no requirement of clinical practicality, but is intended to expose vulnerabilities. The second set exposes clinically realistic vulnerabilities. To circumvent limitations inherent to user-specific tuning of prediction algorithms to match measurements, digital test cases are manually constructed, thereby mimicking high-quality image prediction. Results: With a 3 mm distance-to-agreement metric, changing field size by ±6 mm results in a gamma passing rate over 99%. For a uniform field, a lattice of passing points spaced 5 mm apart results in a passing rate of 100%. Exploiting the percent-passing component, a 10×10 cm{sup 2} field can have a 95% passing rate when an 8 cm{sup 2}=2.8×2.8 cm{sup 2} highly out-of-tolerance (e.g. zero dose) square is missing from the comparison image. For clinically realistic vulnerabilities, an arc plan for which a 2D image is created can have a >95% passing rate solely due to agreement in the lateral spillage, with the failing 5% in the critical target region. A field with an integrated boost (e.g whole brain plus small metastases) could neglect the metastases entirely, yet still pass with a 95% threshold. All the failure modes described would be visually apparent on a gamma-map image. Conclusion: The %gamma<1 metric has significant vulnerabilities. High passing rates can obscure critical faults in hypothetical and delivered radiation doses. Great caution should be used with gamma as a QA metric; users should inspect the gamma-map. Visual analysis of gamma-maps may be impractical for cine acquisition.

60 APPLIED LIFE SCIENCES↗

Computational Estimation by Scientific Data Mining with Classical Methods to Automate Learning Strategies of Scientists

Experimental results are often plotted as 2-dimensional graphical plots (aka graphs) in scientific domains depicting dependent versus independent variables to aid visual analysis of processes. Repeatedly performing laboratory experiments consumes significant time and resources, motivating the need for computational estimation. The goals are to estimate the graph obtained in an experiment given its input conditions, and to estimate the conditions that would lead to a desired graph. Existing estimation approaches often do not meet accuracy and efficiency needs of targeted applications. We develop a computational estimation approach called AutoDomainMine that integrates clustering and classification over complex scientific data in a framework so as to automate classical learning methods of scientists. Knowledge discovered thereby from a database of existing experiments serves as the basis for estimation. Challenges include preserving domain semantics in clustering, finding matching strategies in classification, striking a good balance between elaboration and conciseness while displaying estimation results based on needs of targeted users, and deriving objective measures to capture subjective user interests. These and other challenges are addressed in this work. The AutoDomainMine approach is used to build a computational estimation system, rigorously evaluated with real data in Materials Science. Our evaluation confirms that AutoDomainMine provides desired accuracy and efficiency in computational estimation. It is extendable to other science and engineering domains as proved by adaptation of its sub-processes within fields such as Bioinformatics and Nanotechnology.

Computer Science↗

ECoG Cluster Flow v1.0

ECoG ClusterFlow is a novel multi-scale visual analysis system for the detailed exploration of dynamic functional connectivity graphs obtained through electrocorticography.

MURUGESAN, SUGEERTH↗

AEflow (Autoencoder fluid flow compression network) [SWR-22-29]

As the size of turbulent flow simulations continues to grow, in situ data compression is becoming increasingly important for visualization, analysis, and restart checkpointing. For these applications, single-pass compression techniques with low computational and communication overhead are crucial. In this paper we present a deep-learning approach to in situ compression using an autoencoder architecture that is customized for three-dimensional turbulent flows and is well suited for contemporary heterogeneous computing resources. The autoencoder is compared against a recently introduced randomized single-pass singular value decomposition (SVD) for three different canonical turbulent flows: decaying homogeneous isotropic turbulence, a Taylor-Green vortex, and turbulent channel flow. Our proposed fully convolutional autoencoder architecture compresses turbulent flow snapshots by a factor of 64 with a single pass, allows for arbitrarily sized input fields, is cheaper to compute than the randomized single-pass SVD for typical simulation sizes, performs well on unseen flow configurations, and has been made publicly available. The results reported here show that the autoencoder dramatically outperforms a randomized single-pass SVD with similar compression ratio and yields comparable performance to a higher-rank decomposition with an order of magnitude less compression in regard to preserving a number of important statistical quantities such as turbulent kinetic energy, enstrophy, and Reynolds stresses.

King, Ryan↗