Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Accuracy of the electron transport in mcnp5 and its suitability for ionization chamber response simulations: A comparison with the egsnrc and penelope codes

Purpose: In this work, accuracy of the mcnp5 code in the electron transport calculations and its suitability for ionization chamber (IC) response simulations in photon beams are studied in comparison to egsnrc and penelope codes. Methods: The electron transport is studied by comparing the depth dose distributions in a water phantom subdivided into thin layers using incident energies (0.05, 0.1, 1, and 10 MeV) for the broad parallel electron beams. The IC response simulations are studied in water phantom in three dosimetric gas materials (air, argon, and methane based tissue equivalent gas) for photon beams ({sup 60}Co source, 6 MV linear medical accelerator, and mono-energetic 2 MeV photon source). Two optional electron transport models of mcnp5 are evaluated: the ITS-based electron energy indexing (mcnp5{sub ITS}) and the new detailed electron energy-loss straggling logic (mcnp5{sub new}). The electron substep length (ESTEP parameter) dependency in mcnp5 is investigated as well. Results: For the electron beam studies, large discrepancies (>3%) are observed between the mcnp5 dose distributions and the reference codes at 1 MeV and lower energies. The discrepancy is especially notable for 0.1 and 0.05 MeV electron beams. The boundary crossing artifacts, which are well known for the mcnp5{sub ITS}, are observed for the mcnp5{sub new} only at 0.1 and 0.05 MeV beam energies. If the excessive boundary crossing is eliminated by using single scoring cells, the mcnp5{sub ITS} provides dose distributions that agree better with the reference codes than mcnp5{sub new}. The mcnp5 dose estimates for the gas cavity agree within 1% with the reference codes, if the mcnp5{sub ITS} is applied or electron substep length is set adequately for the gas in the cavity using the mcnp5{sub new}. The mcnp5{sub new} results are found highly dependent on the chosen electron substep length and might lead up to 15% underestimation of the absorbed dose. Conclusions: Since the mcnp5 electron transport calculations are not accurate at all energies and in every medium by general clinical standards, caution is needed, if mcnp5 is used with the current electron transport models for dosimetric applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of large motions of nonuniform beams in orbit. II - The unrestrained beam

An algorithm is developed for the numerical simulation of large motions of an unrestrained, nonuniform beam in orbit. Explicit provisions are made for the accommodation of general, physically significant initial conditions and for the specification of control forces in practical terms. The evaluation of certain constants that appear in the equations of motion is considered, the finite element method being used for this purpose. The importance of initial conditions in the study of spacecraft motions is stressed.

Kane, T. R.↗

Analysis of 140 gigahertz folded frame travelling wave tube

A study on the low voltage, high efficiency and wide bandwidth travelling wave tube by using a novel folded frame slow-wave structure is carried out in this paper. The radio frequency characteristics of the folded frame structure, including dispersion property, interaction impedances, and reflection property are investigated and compared to the similar symmetric double V-shape meander-line structure. Then, the beam-wave interaction process of the folded frame travelling wave tube (TWT) with rectangular sheet electron beam is simulated by 3-D particle-in-cell algorithms. The results show that the output power and electron efficiency can reach 259 W and 13.5% at the center frequency of 140 GHz, respectively. Simultaneously, the instantaneous 3-dB bandwidth is 24 GHz. Compared to the symmetric double V-shaped TWT, the output power and electron efficiency of the folded frame TWT are increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational approaches to Coherent Synchrotron Radiation in two and three dimensions

Coherent Synchrotron Radiation (CSR) is an important and often detrimental effect in particle accelerators. While one-dimensional models have been successfully used to design and explain the behavior of modern machines, questions remain about their domain of validity. In recent years, two- and three-dimensional models have been developed that are amenable to efficient numerical computation. This article gives an overview of CSR computation from its discovery through the present state of the art.

43 PARTICLE ACCELERATORS↗

Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs

Purpose: An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geometry of the system requires trade-offs between patient dose, imaging field of view (FOV), and tomographic angle.Methods: Tomosynthetic angle as a function of tumor-to-detector distance was calculated. Monte Carlo Software (PCXMC) was used to calculate organ doses and effective dose for source-to-detector distances (SDDs) from 90 to 150 cm, patient locations with the tumor at 20 cm from the source to 20 cm from the detector, and FOVs centered on left lung and right lung as well as medial and distal peripheries of the lungs. These calculations were done for two systems, a SBDX system and a GE OEC-9800 C-arm fluoroscopic unit. To evaluate the dose effect of the system geometry, results from PCXMC were calculated using a scan of 300 mAs for both SBDX and fluoroscopy. The Rose Criterion was used to find the fluence required for a tumor SNR of 5, factoring in scatter, air-gap, system geometry, and patient position for all models generated with PCXMC. Using the calculated fluence for constant tumor SNR, the results from PCXMC were used to compare the patient dose for a given SNR between SBDX and fluoroscopy.Results: Tomographic angle changes with SDD only in the region near the detector. Due to their geometry, the source array and detector have a peak tomographic angle for any given SDD at a source to tumor distance that is 69.7% of the SDD assuming constant source and detector size. Changing the patient location in order to increase tomographic angle has a significant effect on organ dose distribution due to geometrical considerations. With SBDX and fluoroscopy geometries, the dose to organs typically changes in an opposing manner with changing patient location. When tumor SNR is held constant (i.e., x-ray fluence is scaled appropriately), SBDX gives 2–10 times less dose than fluoroscopy for the same conditions within the typical range of patient locations. The relative position of the patient (as a percent of SDD) has a much more significant impact on dose than either SDD or patient position. The patient position providing the minimum dose for a given tumor SNR and SDD is approximately the same as the position of maximum tomographic angle.Conclusions: SBDX offers a significant dose advantage over currently used C-arm fluoroscopy. The patient location with lowest dose coincides with the location of maximum tomographic angle. In order to provide adequate space for the patient and for the pulmonologists’ equipment, a SDD of 100 cm is recommended.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-222: Feasibility Study of MRI-Only Proton Therapy Planning

Purpose: To assess the dosimetric equivalence of MRI based proton planning vs. single energy x-ray CT. Methods: 8 glioblastoma patients were imaged with CT and MRI after surgical resection. T1-weighted 3DMPRAGE was used to delineate the GTV, which was subsequently rigidly registered to the CT volume. A pseudoCT was generated from the aligned MRI by combining segmentation and atlas-based approaches. The spatial resolution both for pseudo- and real CT was 0.6×0.6×2.5mm. Three orthogonal proton beams were simulated on the pseudoCT. Two co-planar beams were set on the axial plane. The third one was planned parallel to the cranio-caudal (CC) direction. Each beam was set to cover the GTV at 98% of the nominal dose (18Gy). The proton plan was copied and transferred to the real CT, including aperture/compensator geometry. Dose comparison between pseudoCT and CT plan was performed beam-by-beam by quantifying the range shift of dose profile on each slice of the GTV. The GTV’s V{sub 98} was computed for the CT. Results: For beams in axial plane the median absolute value of the range shift was 0.3mm, with 0.9mm and 1.4mm as 95th percentile and maximum, respectively. Worst scenarios were found for the CC beam, where we measured 1.1mm (median), 2.7mm (95thpercentile) and 5mm (maximum). Regardless the direction, beams passing through the surgical site, where metal (Titanium MRI-compatible) staples were present, were mostly affected by range shift. GTV’s V{sub 98} for CT was not lower than 99.3%. Conclusion: The study showed the clinical feasibility of an MRI-alone proton plan. Advantages include the possibility to rely on better soft tissue contrast for target and organs at risk delineation without the need of further CT scan and image registration. Additional investigation is required in presence of metal implants along the beam path and to account for partial volume effects due to slice thickness.

60 APPLIED LIFE SCIENCES↗

Target and orbit feedback simulations of a muSR beam line at BNL

Well-polarized positive surface muons are a tool to measure the magnetic properties of materials since the precession rate of the spin can be determined from the observation of the positron directions when the muons decay. For a dc beam an ideal µSR flux for surface µ + should be about 40 kHz/mm 2 . In this report we show how this flux could be achieved in a beam line using the AGS complex at BNL for a source of protons. We also determined that an orbit feedback system with a pair of thin silicon position monitors and kickers would miss the desired flux by at least an order of magnitude, even with perfect time resolution and no multiple scattering.

43 PARTICLE ACCELERATORS↗

Guide for 3D WARP simulations of hollow electron beam lenses. Practical explanation on basis of Tevatron electron lens test stand

The purpose of this guide is to help successive students handle WARP. It outlines the installation of WARP on personal computers as well as super-computers and clusters. It furthermore teaches the reader how to handle the WARP environment and run basic scripts. Lastly it outlines how to execute the current Hollow Electron Beam Lens scripts.

97 MATHEMATICS AND COMPUTING↗

Beam and Spin Optics Simulation Tutorials, Using Zgoubi

This tutorial is an introduction to the classical cyclotron, with some hints at spin dynamics, hands-on: by numerical simulation. It begins with a brief reminder of the historic context, and then introduces the theoretical material needed for the simulation exercises, which follow. Basic charge particle optics and acceleration concepts are addressed, including closed orbit in a cyclic accelerator, weak focusing in a dipole magnet, periodic transverse motion, revolution period and isochronism, voltage gap and resonant acceleration, the cyclotron equation.

43 PARTICLE ACCELERATORS↗

Laboratory simulation of injection particle beams in the ionosphere

A series of experiments were carried out in large vacuum chambers in an attempt to understand the physics of the beam injection experiments. In the experiments, the electron beam was injected into an initially neutral gas. A plasma then accumulated as a result of ionization of the gas by the electron beam. The long interaction length and the longitudinal magnetic field resulted in the accumulation plasma densities considerably greater than the beam density. The most significant experimental result is that electron beams in the low keV energy range can ignite the beam plasma discharge (BPD) when their perveance is greater than 5 x 10 to the -7th AV exp -3/2, for pressures typical of the ionosphere. Ignition of the BPD may provide an explanation for many of the puzzling results observed in flight injection experiments.

Kellogg, P. J.↗

Obtaining an equivalent beam

In modeling a complex structure the researcher was faced with a component that would have logical appeal if it were modeled as a beam. The structure was a mast of a robot controlled gantry crane. The structure up to this point already had a large number of degrees of freedom, so the idea of conserving grid points by modeling the mast as a beam was attractive. The researcher decided to make a separate problem of of the mast and model it in three dimensions with plates, then extract the equivalent beam properties by setting up the loading to simulate beam-like deformation and constraints. The results could then be used to represent the mast as a beam in the full model. A comparison was made of properties derived from models of different constraints versus manual calculations. The researcher shows that the three-dimensional model is ineffective in trying to conform to the requirements of an equivalent beam representation. If a full 3-D plate model were used in the complete representation of the crane structure, good results would be obtained. Since the attempt is to economize on the size of the model, a better way to achieve the same results is to use substructuring and condense the mast to equivalent end boundary and intermediate mass points.

Butler, Thomas G.↗

Electron beam injection during active experiments. I - Electromagnetic wave emissions

The wave emissions produced in Echo 7 experiment by active injections of electron beams were investigated to determine the properties of the electromagnetic and electrostatic fields for both the field-aligned and cross-field injection in such experiments and to evaluate the sources of free energy and relative efficiencies for the generation of the VLF and HF emissions. It is shown that, for typical beam energies in active experiments, electromagnetic effects do not substantially change the bulk properties of the beam, spacecraft charging, and plasma particle acceleration. Through simulations, beam-generated whistlers; fundamental z-mode and harmonic x-mode radiation; and electrostatic electron-cyclotron, upper-hybrid, Langmuir, and lower-hybrid waves were identified. The characteristics of the observed wave spectra were found to be sensitive to both the ratio of the electron plasma frequency to the cyclotron frequency and the angle of injection relative to the magnetic field.

Winglee, R. M.↗

Automated detection and analysis of particle beams in laser-plasma accelerator simulations

Numerical simulations of laser-plasma wakefield (particle) accelerators model the acceleration of electrons trapped in plasma oscillations (wakes) left behind when an intense laser pulse propagates through the plasma. The goal of these simulations is to better understand the process involved in plasma wake generation and how electrons are trapped and accelerated by the wake. Understanding of such accelerators, and their development, offer high accelerating gradients, potentially reducing size and cost of new accelerators. One operating regime of interest is where a trapped subset of electrons loads the wake and forms an isolated group of accelerated particles with low spread in momentum and position, desirable characteristics for many applications. The electrons trapped in the wake may be accelerated to high energies, the plasma gradient in the wake reaching up to a gigaelectronvolt per centimeter. High-energy electron accelerators power intense X-ray radiation to terahertz sources, and are used in many applications including medical radiotherapy and imaging. To extract information from the simulation about the quality of the beam, a typical approach is to examine plots of the entire dataset, visually determining the adequate parameters necessary to select a subset of particles, which is then further analyzed. This procedure requires laborious examination of massive data sets over many time steps using several plots, a routine that is unfeasible for large data collections. Demand for automated analysis is growing along with the volume and size of simulations. Current 2D LWFA simulation datasets are typically between 1GB and 100GB in size, but simulations in 3D are of the order of TBs. The increase in the number of datasets and dataset sizes leads to a need for automatic routines to recognize particle patterns as particle bunches (beam of electrons) for subsequent analysis. Because of the growth in dataset size, the application of machine learning techniques for scientific data mining is increasingly considered. In plasma simulations, Bagherjeiran et al. presented a comprehensive report on applying graph-based techniques for orbit classification. They used the KAM classifier to label points and components in single and multiple orbits. Love et al. conducted an image space analysis of coherent structures in plasma simulations. They used a number of segmentation and region-growing techniques to isolate regions of interest in orbit plots. Both approaches analyzed particle accelerator data, targeting the system dynamics in terms of particle orbits. However, they did not address particle dynamics as a function of time or inspected the behavior of bunches of particles. Ruebel et al. addressed the visual analysis of massive laser wakefield acceleration (LWFA) simulation data using interactive procedures to query the data. Sophisticated visualization tools were provided to inspect the data manually. Ruebel et al. have integrated these tools to the visualization and analysis system VisIt, in addition to utilizing efficient data management based on HDF5, H5Part, and the index/query tool FastBit. In Ruebel et al. proposed automatic beam path analysis using a suite of methods to classify particles in simulation data and to analyze their temporal evolution. To enable researchers to accurately define particle beams, the method computes a set of measures based on the path of particles relative to the distance of the particles to a beam. To achieve good performance, this framework uses an analysis pipeline designed to quickly reduce the amount of data that needs to be considered in the actual path distance computation. As part of this process, region-growing methods are utilized to detect particle bunches at single time steps. Efficient data reduction is essential to enable automated analysis of large data sets as described in the next section, where data reduction methods are steered to the particular requirements of our clustering analysis. Previously, we have described the application of a set of algorithms to automate the data analysis and classification of particle beams in the LWFA simulation data, identifying locations with high density of high energy particles. These algorithms detected high density locations (nodes) in each time step, i.e. maximum points on the particle distribution for only one spatial variable. Each node was correlated to a node in previous or later time steps by linking these nodes according to a pruned minimum spanning tree (PMST). We call the PMST representation 'a lifetime diagram', which is a graphical tool to show temporal information of high dense groups of particles in the longitudinal direction for the time series. Electron bunch compactness was described by another step of the processing, designed to partition each time step, using fuzzy clustering, into a fixed number of clusters.

43 PARTICLE ACCELERATORS↗