Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherent diffraction imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Coherent Synchrotron-Based Micro-Imaging Employed for Studies of Micro-Gap Formation in Dental Implants

Biocompatible materials such as titanium are regularly applied in oral surgery. Titanium-based implants for the replacement of missing teeth demand a high mechanical precision in order to minimize micro-bacterial leakage, especially when two-piece concepts are used. Synchrotron-based hard x-ray radiography, unlike conventional laboratory radiography, allows high spatial resolution in combination with high contrast even when micro-sized features in such highly attenuating objects are visualized. Therefore, micro-gap formation at interfaces in two-piece dental implants with the sample under different mechanical loads can be studied. We show the existence of micro-gaps in implants with conical connections and study the mechanical behavior of the mating zone of conical implants during loading. The micro-gap is a potential source of implant failure, i.e., bacterial leakage, which can be a stimulus for an inflammatory process.

60 APPLIED LIFE SCIENCES↗

Observing Exoplanets with High-dispersion Coronagraphy. II. Demonstration of an Active Single-mode Fiber Injection Unit

High-dispersion coronagraphy (HDC) optimally combines high-contrast imaging techniques such as adaptive optics/wavefront control plus coronagraphy to high spectral resolution spectroscopy. HDC is a critical pathway toward fully characterizing exoplanet atmospheres across a broad range of masses from giant gaseous planets down to Earth-like planets. In addition to determining the molecular composition of exoplanet atmospheres, HDC also enables Doppler mapping of atmosphere inhomogeneities (temperature, clouds, wind), as well as precise measurements of exoplanet rotational velocities. Here, we demonstrate an innovative concept for injecting the directly imaged planet light into a single-mode fiber, linking a high-contrast adaptively corrected coronagraph to a high-resolution spectrograph (diffraction-limited or not). Our laboratory demonstration includes three key milestones: close-to-theoretical injection efficiency, accurate pointing and tracking, and on-fiber coherent modulation and speckle nulling of spurious starlight signal coupling into the fiber. Using the extreme modal selectivity of single-mode fibers, we also demonstrated speckle suppression gains that outperform conventional image-based speckle nulling by at least two orders of magnitude.

79 ASTRONOMY AND ASTROPHYSICS↗

Tailoring Vanadium Dioxide Film Orientation Using Nanosheets: a Combined Microscopy, Diffraction, Transport, and Soft X‐Ray in Transmission Study

Abstract Vanadium dioxide (VO 2 ) is a much‐discussed material for oxide electronics and neuromorphic computing applications. Here, heteroepitaxy of VO 2 is realized on top of oxide nanosheets that cover either the amorphous silicon dioxide surfaces of Si substrates or X‐ray transparent silicon nitride membranes. The out‐of‐plane orientation of the VO 2 thin films is controlled at will between (011) M1 /(110) R and (−402) M1 /(002) R by coating the bulk substrates with Ti 0.87 O 2 and NbWO 6 nanosheets, respectively, prior to VO 2 growth. Temperature‐dependent X‐ray diffraction and automated crystal orientation mapping in microprobe transmission electron microscope mode (ACOM‐TEM) characterize the high phase purity, the crystallographic and orientational properties of the VO 2 films. Transport measurements and soft X‐ray absorption in transmission are used to probe the VO 2 metal–insulator transition, showing results of a quality equal to those from epitaxial films on bulk single‐crystal substrates. Successful local manipulation of two different VO 2 orientations on a single substrate is demonstrated using VO 2 grown on lithographically patterned lines of Ti 0.87 O 2 and NbWO 6 nanosheets investigated by electron backscatter diffraction. Finally, the excellent suitability of these nanosheet‐templated VO 2 films for advanced lensless imaging of the metal–insulator transition using coherent soft X‐rays is discussed.

Le, Phu Tran Phong↗

Diffraction imaging of crystals with focused x-ray beams

We describe an imaging technique based on diffraction of a focused x-ray beam in crystals. A focused beam is formed by a zone plate and Bragg diffracted from a crystalline sample positioned between the zone plate and the focus. The intensity pattern is recorded by a high-resolution charge-coupled-device detector placed in the focus. Diffraction images recorded from perfect Si and GaAs crystals for various reflections demonstrate the broadening of the focused beam due to a finite scattering length. The images from semiconductor epitaxial films and heterostructures show additional peaks originating from the interfaces with their spatial position corresponding to the depth from the surface. Diffraction images from isolated defects in Si crystal demonstrate capabilities to study bulk defects. Theoretical simulations for perfect crystals show excellent agreement with experiments. We demonstrate that the new imaging technique is depth sensitive and combines structural sensitivity of traditional x-ray topography methods with spatial in-plane resolution provided by focusing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Femtosecond time-resolved MeV electron diffraction

We report the experimental demonstration of femtosecond electron diffraction using high-brightness MeV electron beams. High-quality, single-shot electron diffraction patterns for both polycrystalline aluminum and single-crystal 1T-TaS 2 are obtained utilizing a 5 fC (~3 × 10 4 electrons) pulse of electrons at 2.8 MeV. The high quality of the electron diffraction patterns confirms that electron beam has a normalized emittance of ~50 nm rad. The transverse and longitudinal coherence length is ~11 and ~2.5 nm, respectively. The timing jitter between the pump laser and probe electron beam was found to be ~100 fs (rms). The temporal resolution is demonstrated by observing the evolution of Bragg and superlattice peaks of 1T-TaS 2 following an 800 nm optical pump and was found to be 130 fs. Lastly, our results demonstrate the advantages of MeV electrons, including large elastic differential scattering cross-section and access to high-order reflections, and the feasibility of ultimately realizing below 10 fs time-resolved electron diffraction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Structural Consequences of Ferroelectric Nanolithography

Domains of remnant polarization can be written into ferroelectrics with nanoscale precision using scanning probe nanolithography techniques such as piezoresponse force microscopy (PFM). Understanding the structural effects accompanying this process has been challenging due to the lack of appropriate structural characterization tools. Synchrotron X-ray nanodiffraction provides images of the domain structure written by PFM into an epitaxial Pb(Zr,Ti)O{sub 3} thin film and simultaneously reveals structural effects arising from the writing process. A coherent scattering simulation including the superposition of the beams simultaneously diffracted by multiple mosaic blocks provides an excellent fit to the observed diffraction patterns. Domains in which the polarization is reversed from the as-grown state have a strain of up to 0.1% representing the piezoelectric response to unscreened surface charges. An additional X-ray microdiffraction study of the photon-energy dependence of the difference in diffracted intensity between opposite polarization states shows that this contrast has a crystallographic origin. The sign and magnitude of the intensity contrast between domains of opposite polarization are consistent with the polarization expected from PFM images and with the writing of domains through the entire thickness of the ferroelectric layer. The strain induced by writing provides a significant additional contribution to the increased free energy of the written domain state with respect to a uniformly polarized state.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

X-ray characterization of low-thermal conductivity thin-film materials.

X-ray diffraction and imaging techniques at the Advanced Photon Source (APS) have been used to characterize PbSe/MoSe{sub 2} and PbSe/WSe{sub 2} thin films and multilayers. Diffraction measurements with area detectors were made to demonstrate the nanoscale coherence size of the layers both in-plane and perpendicular to the surface. Higher-resolution diffraction measurements that exploit the tunability of synchrotron radiation for anomalous scattering contrast have been used to accurately determine layer spacings in these multilayers. We also discuss opportunities in other new and emerging x-ray techniques, such as time-resolved studies during growth or processing, and present x-ray imaging capabilities that can be used to investigate thermoelectric thin-film materials.

43 PARTICLE ACCELERATORS↗

Model based atomic resolution tomography

Electron tomography is a valuable three-dimensional characterization method, but the technique has so far been limited to a nanometer scale resolution, and therefore complementary two-dimensional structural analysis is generally performed using other techniques. In this paper, computer simulations of the latest transmission electron microscope technologies are performed on a CeO{sub 2} supercell to investigate the extension of electron tomography to the atomic scale resolution, from a tilt series of high resolution electron microscopy (HREM) images. We showed that high-voltage and aberration-corrected microscopes were both capable of retrieving adjacent oxygen and Ce atoms for a thickness up to 2.5 nm. In the case where only a few tilt angle projections are in zone-axis orientations, we introduced a hybrid tomography method, whereby a lattice-resolved tomogram obtained from a few zone-axis projections is combined with the external shape reconstruction of the crystal from binary projections. Finally, we discussed some experimental challenges related to the proposed HREM tomography technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tagging efficiency study of incoherent diffractive vector meson production at the second interaction region at the Electron-Ion Collider

The Electron-Ion Collider (EIC) is an upcoming accelerator facility aimed at exploring the properties of quarks and gluons in nucleons and nuclei, shedding light on their structure and dynamics. The inaugural experimental apparatus, ePIC (electron-Proton and Ion Collider), is designed as a general-purpose detector to address the National Academy of Sciences and the Nuclear Science Advisory Committee physics program at the EIC. The wider EIC community is strongly supporting a second interaction region and an associated second detector to enhance the full science program. In this study, we evaluate how this second interaction region and detector can be complementary to ePIC. The layout of an interaction region for the second detector offers a secondary focus that provides better forward detector acceptance at scattering angles near θ ~ 0 mrad, which can specifically enhance the exclusive, tagging, and diffractive physics program. Here, this article presents an analysis of a tagging program using the second interaction region layout with incoherent diffractive vector meson production. The current design of the second EIC interaction region is evaluated for its vetoing capabilities of incoherent events required for the study of coherent diffractive measurements. We find an increased vetoing performance compared to the ePIC interaction region, thus improving measurements which are important for the spatial imaging of nucleons and nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-efficiency coherence-preserving harmonic rejection with crystal optics

This work reports a harmonic-rejection scheme based on the combination of Si(111) monochromator and Si(220) harmonic-rejection crystal optics. This approach is of importance to a wide range of X-ray applications in all three major branches of modern X-ray science (scattering, spectroscopy, imaging) based at major facilities, and especially relevant to the capabilities offered by the new diffraction-limited storage rings. It was demonstrated both theoretically and experimentally that, when used with a synchrotron undulator source over a broad range of X-ray energies of interest, the harmonic-rejection crystals transmit the incident harmonic X-rays on the order of 10 –6 . Considering the flux ratio of fundamental and harmonic X-rays in the incident beam, this scheme achieves a total flux ratio of harmonic radiation to fundamental radiation on the order of 10 –10 . The spatial coherence of the undulator beam is preserved in the transmitted fundamental radiation while the harmonic radiation is suppressed, making this scheme suitable not only for current third-generation synchrotron sources but also for the new diffraction-limited storage rings where coherence preservation is an even higher priority. Compared with conventional harmonic-rejection mirrors, where coherence is poorly preserved and harmonic rejection is less effective, this scheme has the added advantage of lower cost and footprint. Furthermore, this approach has been successfully utilized at the ultra-small-angle X-ray scattering instrument at the Advanced Photon Source for scattering, imaging and coherent X-ray photon correlation spectroscopy experiments. With minor modification, the harmonic rejection can be improved by a further five orders of magnitude, enabling even more performance capabilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative agreement between dynamical rocking curves in ultrafast electron diffraction for x-ray lasers

Electron diffraction through a thin patterned silicon membrane can be used to create complex spatial modulations in electron distributions. By precisely varying parameters such as crystallographic orientation and wafer thickness, the intensity of reflections in the diffraction plane can be controlled and by placing an aperture to block all but one spot, we can form an image with different parts of the patterned membrane, as is done for bright-field imaging in microscopy. The patterned electron beams can then be used to control phase and amplitude of subsequent x-ray emission, enabling novel coherent x-ray methods. Furthermore, the electrons themselves can also be used for femtosecond time resolved diffraction and microscopy. As a first step toward patterned beams, we demonstrate experimentally and through simulation the ability to accurately predict and control diffraction spot intensities. We simulate MeV transmission electron diffraction patterns using the multislice method for various crystallographic orientations of a single crystal Si(001) membrane near beam normal. The resulting intensity maps of the Bragg reflections are compared to experimental results obtained at the Accelerator Structure Test Area Ultrafast Electron Diffraction (ASTA UED) facility at SLAC. Furthermore, the fraction of inelastic and elastic scattering of the initial charge is estimated along with the absorption of the membrane to determine the contrast that would be seen in a patterned version of the Si(001) membrane.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-time X-ray Diffraction Measurements of Shocked Polycrystalline Tin and Aluminum

A new, fast, single-pulse x-ray diffraction (XRD) diagnostic for determining phase transitions in shocked polycrystalline materials has been developed. The diagnostic consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, producing line and bremsstrahlung x-ray emission in a 35-ns pulse. The characteristic Kα lines from the selected anodes of silver and molybdenum are used to produce the diffraction patterns, with thin foil filters employed to remove the characteristic Kβ line emission. The x-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 3-mm by 6-mm spot and 1° full-width-half-maximum (FWHM) angular divergence in a Bragg-reflecting geometry. For the experiments described in this report, the angle between the incident beam and the sample surface was 8.5°. A Debye-Scherrer diffraction image was produced on a phosphor located 76 mm from the polycrystalline sample surface. The phosphor image was coupled to a charge-coupled device (CCD) camera through a coherent fiberoptic bundle. Dynamic single-pulse XRD experiments were conducted with thin foil samples of tin, shock loaded with a 1-mm vitreous carbon back window. Detasheet high explosive with a 2-mm-thick aluminum buffer was used to shock the sample. Analysis of the dynamic shock-loaded tin XRD images revealed a phase transformation of the tin beta phase into an amorphous or liquid state. Identical experiments with shock-loaded aluminum indicated compression of the face-centered-cubic (fcc) aluminum lattice with no phase transformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cepstral scanning transmission electron microscopy imaging of severe lattice distortions

The development of four-dimensional (4D) scanning transmission electron microscopy (STEM) using fast detectors has opened-up new avenues for addressing some of longstanding challenges in electron imaging. One of these challenges is how to image severely distorted crystal lattices, such as at a dislocation core. Here we develop a new 4D-STEM technique, called Cepstral STEM, for imaging disordered crystals using electron diffuse scattering. In contrast to analysis based on Bragg diffraction, which measures the average and periodic scattering potential, electron diffuse scattering can detect fluctuations caused by crystal disorder. Local fluctuations of diffuse scattering are captured by scanning electron nanodiffraction (SEND) using a coherent probe. The harmonic signals in electron diffuse scattering are detected through Cepstral analysis and used for imaging. By integrating Cepstral analysis with 4D-STEM, we demonstrate that information about the distortive part of electron scattering potential can be separated and imaged at nm spatial resolution. Here, we apply the technique to the analysis of a dislocation core in SiGe and lattice distortions in a high entropy alloy.

36 MATERIALS SCIENCE↗

30-lens interferometer for high energy x-rays

We report a hard X-ray multilens interferometer consisting of 30 parallel compound refractive lenses. Under coherent illumination each CRL creates a diffraction limited focal spot - secondary source. An overlapping of coherent beams from these sources resulting in the interference pattern which has a rich longitudinal structure in accordance with the Talbot imaging formalism. The proposed interferometer was experimentally tested at ID11 ESRF beamline for the photon energies 32 keV and 65 keV. The fundamental and fractional Talbot images were recorded with the high resolution CCD camera. An effective source size in the order of 15 µm was determined from the first Talbot image proving that the multilens interferometer can be used as a high resolution beam diagnostic tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Early age strength enhancement of blended cement systems by CaCl{sub 2} and diethanol-isopropanolamine

The enhancement of the 1 day strength of cementitious systems by a combination of calcium chloride (CaCl{sub 2}) and diethanol-isopropanolamine (DEIPA) was studied, particularly in blended cement systems. A combination of quantitative X-ray diffraction with Rietveld refinement (QXRD), scanning electron microscopy (SEM)/backscattered electron image analysis, thermogravimetric analysis (TGA), and isothermal calorimetry were used to investigate the mechanism of strength enhancement by the additives. The additives were found to increase the early age mortar strength by enhancing the cement hydration, with the DEIPA enhancing primarily the aluminate hydration. DEIPA also affected the morphology of portlandite which was formed as thin plates. In parallel, the calcium-to-silica ratio of the C-S-H was found to increase with the use of DEIPA, possibly because of the inclusion of microcrystalline portlandite. After 48 h DEIPA was found to directly enhance the rate of reaction of granulated blast-furnace slag and fly ash.

36 MATERIALS SCIENCE↗

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

47 OTHER INSTRUMENTATION↗

Characterization of the X-ray coherence properties of an undulator beamline at the Advanced Photon Source

In anticipation of the increased use of coherent X-ray methods and the need to upgrade beamlines to match improved source quality, here the coherence properties of the X-rays delivered by beamline 12ID-D at the Advanced Photon Source have been characterized. The measured X-ray divergence, beam size, brightness and coherent flux at energies up to 26 keV are compared with the calculated values from the undulator source, and the effects of beamline optics such as a mirror, monochromator and compound refractive lenses are evaluated. Diffraction patterns from slits as a function of slit width are analyzed using wave propagation theory to obtain the beam divergence and thus coherence length. Imaging of the source using a compound refractive lens was found to be the most accurate method for determining the vertical divergence. While the brightness and coherent flux obtained without a monochromator (`pink beam') agree well with those calculated for the source, those measured with the monochromator were a factor of three to six lower than the source, primarily because of vertical divergence introduced by the monochromator. The methods described herein should be widely applicable for measuring the X-ray coherence properties of synchrotron beamlines.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Imaging molecules from within: Ultrafast angstroem-scale structure determination of molecules via photoelectron holography using free-electron lasers

A scheme based on (i) upcoming brilliant x-ray free-electron laser (FEL) sources, (ii) innovative energy and angular-dispersive large-area electron imagers, and (iii) the well-known photoelectron holography is elaborated that provides time-dependent three-dimensional structure determination of small to medium-sized molecules with Angstroem spatial and femtosecond time resolution. Inducing molecular dynamics, wave-packet motion, dissociation, passage through conical intersections, or isomerization by a pump pulse this motion is visualized by the x-ray FEL probe pulse launching keV photoelectrons within a few femtoseconds from specific and well-defined sites, deep core levels of individual atoms, inside the molecule. On their way out, the photoelectrons are diffracted generating a hologram on the detector that encodes the molecular structure at the instant of photoionization, thus providing 'femtosecond snapshot images of the molecule from within'. Detailed calculations in various approximations of increasing sophistication are presented and three-dimensional retrieval of the spatial structure of the molecule with Angstroem spatial resolution is demonstrated. Due to the large photoabsorption cross sections the method extends x-ray-diffraction-based time-dependent structure investigations envisioned at FEL's to new classes of samples that are not accessible by any other method. Among them are dilute samples in the gas phase such as aligned, oriented, or conformer-selected molecules, ultracold ensembles and/or molecular or cluster objects containing mainly light atoms that do not scatter x rays efficiently.

74 ATOMIC AND MOLECULAR PHYSICS↗