Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherent diffractive imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Model based atomic resolution tomography

Electron tomography is a valuable three-dimensional characterization method, but the technique has so far been limited to a nanometer scale resolution, and therefore complementary two-dimensional structural analysis is generally performed using other techniques. In this paper, computer simulations of the latest transmission electron microscope technologies are performed on a CeO{sub 2} supercell to investigate the extension of electron tomography to the atomic scale resolution, from a tilt series of high resolution electron microscopy (HREM) images. We showed that high-voltage and aberration-corrected microscopes were both capable of retrieving adjacent oxygen and Ce atoms for a thickness up to 2.5 nm. In the case where only a few tilt angle projections are in zone-axis orientations, we introduced a hybrid tomography method, whereby a lattice-resolved tomogram obtained from a few zone-axis projections is combined with the external shape reconstruction of the crystal from binary projections. Finally, we discussed some experimental challenges related to the proposed HREM tomography technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tagging efficiency study of incoherent diffractive vector meson production at the second interaction region at the Electron-Ion Collider

The Electron-Ion Collider (EIC) is an upcoming accelerator facility aimed at exploring the properties of quarks and gluons in nucleons and nuclei, shedding light on their structure and dynamics. The inaugural experimental apparatus, ePIC (electron-Proton and Ion Collider), is designed as a general-purpose detector to address the National Academy of Sciences and the Nuclear Science Advisory Committee physics program at the EIC. The wider EIC community is strongly supporting a second interaction region and an associated second detector to enhance the full science program. In this study, we evaluate how this second interaction region and detector can be complementary to ePIC. The layout of an interaction region for the second detector offers a secondary focus that provides better forward detector acceptance at scattering angles near θ ~ 0 mrad, which can specifically enhance the exclusive, tagging, and diffractive physics program. Here, this article presents an analysis of a tagging program using the second interaction region layout with incoherent diffractive vector meson production. The current design of the second EIC interaction region is evaluated for its vetoing capabilities of incoherent events required for the study of coherent diffractive measurements. We find an increased vetoing performance compared to the ePIC interaction region, thus improving measurements which are important for the spatial imaging of nucleons and nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-efficiency coherence-preserving harmonic rejection with crystal optics

This work reports a harmonic-rejection scheme based on the combination of Si(111) monochromator and Si(220) harmonic-rejection crystal optics. This approach is of importance to a wide range of X-ray applications in all three major branches of modern X-ray science (scattering, spectroscopy, imaging) based at major facilities, and especially relevant to the capabilities offered by the new diffraction-limited storage rings. It was demonstrated both theoretically and experimentally that, when used with a synchrotron undulator source over a broad range of X-ray energies of interest, the harmonic-rejection crystals transmit the incident harmonic X-rays on the order of 10 –6 . Considering the flux ratio of fundamental and harmonic X-rays in the incident beam, this scheme achieves a total flux ratio of harmonic radiation to fundamental radiation on the order of 10 –10 . The spatial coherence of the undulator beam is preserved in the transmitted fundamental radiation while the harmonic radiation is suppressed, making this scheme suitable not only for current third-generation synchrotron sources but also for the new diffraction-limited storage rings where coherence preservation is an even higher priority. Compared with conventional harmonic-rejection mirrors, where coherence is poorly preserved and harmonic rejection is less effective, this scheme has the added advantage of lower cost and footprint. Furthermore, this approach has been successfully utilized at the ultra-small-angle X-ray scattering instrument at the Advanced Photon Source for scattering, imaging and coherent X-ray photon correlation spectroscopy experiments. With minor modification, the harmonic rejection can be improved by a further five orders of magnitude, enabling even more performance capabilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative agreement between dynamical rocking curves in ultrafast electron diffraction for x-ray lasers

Electron diffraction through a thin patterned silicon membrane can be used to create complex spatial modulations in electron distributions. By precisely varying parameters such as crystallographic orientation and wafer thickness, the intensity of reflections in the diffraction plane can be controlled and by placing an aperture to block all but one spot, we can form an image with different parts of the patterned membrane, as is done for bright-field imaging in microscopy. The patterned electron beams can then be used to control phase and amplitude of subsequent x-ray emission, enabling novel coherent x-ray methods. Furthermore, the electrons themselves can also be used for femtosecond time resolved diffraction and microscopy. As a first step toward patterned beams, we demonstrate experimentally and through simulation the ability to accurately predict and control diffraction spot intensities. We simulate MeV transmission electron diffraction patterns using the multislice method for various crystallographic orientations of a single crystal Si(001) membrane near beam normal. The resulting intensity maps of the Bragg reflections are compared to experimental results obtained at the Accelerator Structure Test Area Ultrafast Electron Diffraction (ASTA UED) facility at SLAC. Furthermore, the fraction of inelastic and elastic scattering of the initial charge is estimated along with the absorption of the membrane to determine the contrast that would be seen in a patterned version of the Si(001) membrane.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-time X-ray Diffraction Measurements of Shocked Polycrystalline Tin and Aluminum

A new, fast, single-pulse x-ray diffraction (XRD) diagnostic for determining phase transitions in shocked polycrystalline materials has been developed. The diagnostic consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, producing line and bremsstrahlung x-ray emission in a 35-ns pulse. The characteristic Kα lines from the selected anodes of silver and molybdenum are used to produce the diffraction patterns, with thin foil filters employed to remove the characteristic Kβ line emission. The x-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 3-mm by 6-mm spot and 1° full-width-half-maximum (FWHM) angular divergence in a Bragg-reflecting geometry. For the experiments described in this report, the angle between the incident beam and the sample surface was 8.5°. A Debye-Scherrer diffraction image was produced on a phosphor located 76 mm from the polycrystalline sample surface. The phosphor image was coupled to a charge-coupled device (CCD) camera through a coherent fiberoptic bundle. Dynamic single-pulse XRD experiments were conducted with thin foil samples of tin, shock loaded with a 1-mm vitreous carbon back window. Detasheet high explosive with a 2-mm-thick aluminum buffer was used to shock the sample. Analysis of the dynamic shock-loaded tin XRD images revealed a phase transformation of the tin beta phase into an amorphous or liquid state. Identical experiments with shock-loaded aluminum indicated compression of the face-centered-cubic (fcc) aluminum lattice with no phase transformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cepstral scanning transmission electron microscopy imaging of severe lattice distortions

The development of four-dimensional (4D) scanning transmission electron microscopy (STEM) using fast detectors has opened-up new avenues for addressing some of longstanding challenges in electron imaging. One of these challenges is how to image severely distorted crystal lattices, such as at a dislocation core. Here we develop a new 4D-STEM technique, called Cepstral STEM, for imaging disordered crystals using electron diffuse scattering. In contrast to analysis based on Bragg diffraction, which measures the average and periodic scattering potential, electron diffuse scattering can detect fluctuations caused by crystal disorder. Local fluctuations of diffuse scattering are captured by scanning electron nanodiffraction (SEND) using a coherent probe. The harmonic signals in electron diffuse scattering are detected through Cepstral analysis and used for imaging. By integrating Cepstral analysis with 4D-STEM, we demonstrate that information about the distortive part of electron scattering potential can be separated and imaged at nm spatial resolution. Here, we apply the technique to the analysis of a dislocation core in SiGe and lattice distortions in a high entropy alloy.

36 MATERIALS SCIENCE↗

30-lens interferometer for high energy x-rays

We report a hard X-ray multilens interferometer consisting of 30 parallel compound refractive lenses. Under coherent illumination each CRL creates a diffraction limited focal spot - secondary source. An overlapping of coherent beams from these sources resulting in the interference pattern which has a rich longitudinal structure in accordance with the Talbot imaging formalism. The proposed interferometer was experimentally tested at ID11 ESRF beamline for the photon energies 32 keV and 65 keV. The fundamental and fractional Talbot images were recorded with the high resolution CCD camera. An effective source size in the order of 15 µm was determined from the first Talbot image proving that the multilens interferometer can be used as a high resolution beam diagnostic tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Early age strength enhancement of blended cement systems by CaCl{sub 2} and diethanol-isopropanolamine

The enhancement of the 1 day strength of cementitious systems by a combination of calcium chloride (CaCl{sub 2}) and diethanol-isopropanolamine (DEIPA) was studied, particularly in blended cement systems. A combination of quantitative X-ray diffraction with Rietveld refinement (QXRD), scanning electron microscopy (SEM)/backscattered electron image analysis, thermogravimetric analysis (TGA), and isothermal calorimetry were used to investigate the mechanism of strength enhancement by the additives. The additives were found to increase the early age mortar strength by enhancing the cement hydration, with the DEIPA enhancing primarily the aluminate hydration. DEIPA also affected the morphology of portlandite which was formed as thin plates. In parallel, the calcium-to-silica ratio of the C-S-H was found to increase with the use of DEIPA, possibly because of the inclusion of microcrystalline portlandite. After 48 h DEIPA was found to directly enhance the rate of reaction of granulated blast-furnace slag and fly ash.

36 MATERIALS SCIENCE↗

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

47 OTHER INSTRUMENTATION↗

Characterization of the X-ray coherence properties of an undulator beamline at the Advanced Photon Source

In anticipation of the increased use of coherent X-ray methods and the need to upgrade beamlines to match improved source quality, here the coherence properties of the X-rays delivered by beamline 12ID-D at the Advanced Photon Source have been characterized. The measured X-ray divergence, beam size, brightness and coherent flux at energies up to 26 keV are compared with the calculated values from the undulator source, and the effects of beamline optics such as a mirror, monochromator and compound refractive lenses are evaluated. Diffraction patterns from slits as a function of slit width are analyzed using wave propagation theory to obtain the beam divergence and thus coherence length. Imaging of the source using a compound refractive lens was found to be the most accurate method for determining the vertical divergence. While the brightness and coherent flux obtained without a monochromator (`pink beam') agree well with those calculated for the source, those measured with the monochromator were a factor of three to six lower than the source, primarily because of vertical divergence introduced by the monochromator. The methods described herein should be widely applicable for measuring the X-ray coherence properties of synchrotron beamlines.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Imaging molecules from within: Ultrafast angstroem-scale structure determination of molecules via photoelectron holography using free-electron lasers

A scheme based on (i) upcoming brilliant x-ray free-electron laser (FEL) sources, (ii) innovative energy and angular-dispersive large-area electron imagers, and (iii) the well-known photoelectron holography is elaborated that provides time-dependent three-dimensional structure determination of small to medium-sized molecules with Angstroem spatial and femtosecond time resolution. Inducing molecular dynamics, wave-packet motion, dissociation, passage through conical intersections, or isomerization by a pump pulse this motion is visualized by the x-ray FEL probe pulse launching keV photoelectrons within a few femtoseconds from specific and well-defined sites, deep core levels of individual atoms, inside the molecule. On their way out, the photoelectrons are diffracted generating a hologram on the detector that encodes the molecular structure at the instant of photoionization, thus providing 'femtosecond snapshot images of the molecule from within'. Detailed calculations in various approximations of increasing sophistication are presented and three-dimensional retrieval of the spatial structure of the molecule with Angstroem spatial resolution is demonstrated. Due to the large photoabsorption cross sections the method extends x-ray-diffraction-based time-dependent structure investigations envisioned at FEL's to new classes of samples that are not accessible by any other method. Among them are dilute samples in the gas phase such as aligned, oriented, or conformer-selected molecules, ultracold ensembles and/or molecular or cluster objects containing mainly light atoms that do not scatter x rays efficiently.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical multiple object tracking techniques

Two multichannel multiple-object tracking techniques are reviewed. In the diffraction grating technique, the input scene is picked up by a TV camera and imaged onto a liquid-crystal light valve (LCLV), and the output side of the light valve is illuminated with a suitably polarized and collimated coherent laser beam to yield a reflected beam with polarization modulated according to the intensity of the incoherent input. This reflected beam passes through a beam splitter cube and an analyzer, resulting in an intensity modulated coherent image. An array of spectrum islands containing the information of the input appears after crossing a contact screen/lens combination. In the multiple-focus hololens technique, the scene of moving objects is sent into the LCTVSLM through a camera; a collimated laser beam is incident upon the LCTV screen; a low-pass filter is inserted between the LCTVSLM and the hololens for the removal of the high order diffractions due to the grid structure of the LCTV. The feasibility of the LCTVSLM and multiple-focus hololens technique is demonstrated.

Liu, Hua-Kuang↗

Extremely High Resolution Single Crystal Diffractometory for Orbital Resolution using High Energy Synchrotron Radiation at SPring-8

The investigation of accurate structure at charge density level will not only understand the function mechanism of physical property but also lead to design new functional materials. We have successfully installed large cylindrical camera at the BL02B1/SPring-8. In conceptual design, the image plate (IP) was selected as the detector, because such IP will not only detect wide range in one shot but also yield reliable data. In commissioning, the performance of this camera demonstrated to be suitable for the direct observation of d-electron system.

43 PARTICLE ACCELERATORS↗

Influence of Sintering Temperature on Microstructure and Electrical Properties of La{sub 0.67}Ba{sub 0.33}MnO{sub 3} Ceramic

In this study we report the effect of the sintering temperature of polycrystalline La{sub 0.67}Ba{sub 0.33}MnO{sub 3}(LBMO) manganites synthesized via solid state reaction method. LBMO have been sintered at 900 to 1200 deg. C in intervals of 100 deg. C. X-ray diffraction spectrum confirms that LBMO phase formation starts at 900 deg. C accompany by a minor second phase of BaMnO{sub 3} and fully forms into single phase of LBMO at 1200 degree sign C. SEM images showed that, the grain size increased with sintering temperature and leading to densifications or lower porosity. The T{sub p} was not affected by the sintering temperature. However, the electrical resistances of samples were decreased with the sintering temperature. At higher sintering temperature, due to grain growth and reduction of insulating BaMnO{sub 3} phase, the intergrain connectivity has been improved and the resistance drops.

36 MATERIALS SCIENCE↗

Diffraction barrier breakthrough in coherent anti-Stokes Raman scattering microscopy by additional probe-beam-induced phonon depletion

We provide an approach to significantly break the diffraction limit in coherent anti-Stokes Raman scattering (CARS) microscopy via an additional probe-beam-induced photon depletion (APIPD). The additional probe beam, whose profile is doughnut shaped and whose wavelength is different from the Gaussian probe beam, depletes the phonons to yield an unwanted anti-Stokes signal within a certain bandwidth at the rim of the diffraction-limited spot. When the Gaussian probe beam that follows immediately arrives, no anti-Stokes signal is generated in this region, resembling stimulated emission depletion (STED) microscopy, and the spot-generating useful anti-Stokes signals by this beam are substantially suppressed to a much smaller dimension. Scanning the spot renders three-dimensional, label-free, and chemically selective CARS images with subdiffraction resolution. Also, resolution-enhanced images of the molecule, specified by its broadband even-total CARS spectral signals not only by one anti-Stokes signal for its special chemical bond, can be obtained by employing a supercontinuum source.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method of optical coherence tomography with parallel depth-resolved signal reception and fibre-optic phase modulators

The method of optical coherence tomography with the scheme of parallel reception of the interference signal (P-OCT) is developed on the basis of spatial paralleling of the reference wave by means of a phase diffraction grating producing the appropriate time delay in the Mach–Zehnder interferometer. The absence of mechanical variation of the optical path difference in the interferometer essentially reduces the time required for 2D imaging of the object internal structure, as compared to the classical OCT that uses the time-domain method of the image construction, the sensitivity and the dynamic range being comparable in both approaches. For the resulting field of the interfering object and reference waves an analytical expression is derived that allows the calculation of the autocorrelation function in the plane of photodetectors. For the first time a method of linear phase modulation by 2π is proposed for P-OCT systems, which allows the use of compact high-frequency (a few hundred kHz) piezoelectric cell-based modulators. For the demonstration of the P-OCT method an experimental setup was created, using which the images of the inner structure of biological objects at the depth up to 1 mm with the axial spatial resolution of 12 μm were obtained. (optical coherence tomography)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructural and compositional change of NaOH-activated high calcium fly ash by incorporating Na-aluminate and co-existence of geopolymeric gel and C-S-H(I)

This study explores the reaction products of alkali-activated Class C fly ash-based aluminosilicate samples by means of high-resolution synchrotron X-ray diffraction (HSXRD), scanning electron microscope (SEM), and compressive strength tests to investigate how the readily available aluminum affects the reaction. Class C fly ash-based aluminosilicate raw materials were prepared by incorporating Na-aluminate into the original fly ashes, then alkali-activated by 10 M NaOH solution. Incorporating Na-aluminate reduced the compressive strength of samples, with the reduction magnitude relatively constant regardless of length of curing period. The HSXRD provides evidence of the co-existence of C-S-H with geopolymeric gels and strongly suggests that the C-S-H formed in the current system is C-S-H(I). The back-scattered electron images suggest that the C-S-H(I) phase exists as small grains in a finely intermixed form with geopolymeric gels. Despite providing extra source of aluminum, adding Na-aluminate to the mixes did not decrease the Si/Al ratio of the geopolymeric gel.

36 MATERIALS SCIENCE↗

Ultrahigh-Resolution Soft-X-Ray Microscopy with Zone Plates in High Orders of Diffraction

We present an x-ray optical approach to overcome the current limitations in spatial resolution of x-ray microscopes. Our new BESSY full-field x-ray microscope operates with an energy resolution up to E/DELTAE=10{sup 4}. We demonstrate that under these conditions it is possible to employ high orders of diffraction for imaging. Using the third order of diffraction of a zone plate objective with 25 nm outermost zone width, 14 nm lines and spaces of a multilayer test structure were clearly resolved. We believe that high-order imaging paves the way towards sub-10-nm real space x-ray imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗