At least 505 records · Page 28

SDN Project

The SDN Project completed on time and on budget and successfully accomplished 100% of the scope of work outlined in the original Statement of Project Objective (SOPO). The SDN Project formed an alliance between Ameren Corporation, University of Illinois Urbana- Champaign (UIUC), Pacific Northwest National Laboratories (PNNL), and Schweitzer Engineering Laboratories, Inc. (SEL). The objective of the SDN Project is to address Topic Area of Interest 2: Sustain critical energy delivery functions while responding to a cyber-intrusion under Funding Opportunity Announcement DE-FOA-0000797. The goal of the project is to design and commercially release technology that provides a method to sustain critical energy delivery functions during a cyber intrusion and to do this control system operators need the ability to quickly identify and isolate the affected network areas, and re-route critical information and control flows around. The objective of the SDN Project is to develop a Flow Controller that monitors, configures, and maintains the safe, reliable network traffic flows of all the local area networks (LANs) on a control system in the Energy sector. The SDN team identified the core attributes of a control system and produced an SDN flow controller that has the same core attributes enabling networks to be designed, configured and deployed that maximize the whitelisted, deny-bydefault and purpose built networks. This project researched, developed and commercially released technology that: Enables all field networks be to configured and monitored as if they are a single asset to be protected; Enables greatly improved and even precalculated response actions to reliability and cyber events; Supports pre-configured localized response actions tailored to provide resilience against failures and centralized response to cyber-attacks that improve network reliability and availability; Architecturally enables the right subject matter experts, who are usually the information technology and operational technology engineers, to be the ones centrally administering the technology and responding to events; Simplifies network configuration, improving deterministic Ethernet transport times, and providing instant visualization on where the communication circuits are and how all circuits are impacted when changes (e.g., configuration changes, failures or intrusions) happen, allowing operators to minimize downtime; and Improves the ability to identify deviations in network behavior resulting in detection and analysis of potential cyber intrusions and faster response times Results: This project has forever changed the way critical infrastructure networks are designed, secured, deployed and maintained. The cybersecurity and performance advantages achieved are significant, simply put traditional networking has been obsoleted while the team maintained Ethernet interoperability avoiding any legacy concerns. The team commercially released technology that accomplished all the cybersecurity goals outlined in the SOPO and completed it by executing the project management plan approved in the initial contract. The resulting Energy sector SDN flow controller model number is SEL-5056 and can be freely downloaded from the www.SELinc.com website. This technology not only improves the cybersecurity of control systems but has measured results that it improves the performance and reliability of the control system as well. This means the system owners can confidently apply it to their systems knowing that it will, “first do no harm” but actually improve the system as well. Success of the project is best measured by the sales and deployment of the technology. System owners in industrial, electric, defense, and oil and gas only months after commercial release have approved plans for deployment.

42 ENGINEERING↗

Recovery and Calibration of Legacy Underground Nuclear Test Seismic Data from the Leo Brady Seismic Network

The Leo Brady Seismic Network (LBSN, originally the Sandia Seismic Network) was established in 1960 by Sandia National Laboratories to monitor underground nuclear tests (UGTs) at the Nevada National Security Site (NNSS, formerly named the Nevada Test Site). The LBSN has been in various configurations throughout its existence, but it has generally been comprised of four to six stations at regional distances (~150–400 km) from the NNSS with approximately evenly spaced azimuthal coverage. Between 1962 and the end of nuclear testing in 1992, the LBSN—and a sister network operated by Lawrence Livermore National Laboratories—was the most comprehensive United States source of regional seismic data of UGTs. Approximately 75% of all UGTs performed by the United States occurred in the predigital era. At that time, LBSN data were transmitted as frequency-modulated (FM) audio over telephone lines to a central location and recorded as analog waveforms on high-fidelity magnetic audio tapes. These tapes have been in dry temperature-stable storage for decades and contain the sole record of this irreplaceable data; full waveforms of LBSN-recorded UGTs from this era were not routinely digitized or otherwise published. We have developed a process to recover and calibrate data from these tapes. First, we play back and digitize the tapes as audio. Next, we demodulate the FM “audio” into individual waveforms. We then estimate the various instrument constants through careful measurement of “weight-lift” tests performed prior to each UGT on each instrument. Finally, these coefficients allow us to scale and shape the derived instrument response of the seismographs and compute poles and zeros. Finally, the result of this process is a digital record of the recorded seismic ground motion in a modern data format, stored in a searchable database. To date, we have digitized tapes from 592 UGTs.

58 GEOSCIENCES↗

Data-Centric Communication Framework for Multicast IEC 61850 Routable GOOSE Messages over the WAN in Modern Power Systems

In this paper, a data-centric communication framework is proposed for multicast routable generic object-oriented substation event (GOOSE) messages (MRGM) over the wide area network (WAN) for effective substation-to-substation (SS2SS) and substation to control center (SS2CC) communications. In this structure, the IEC 61850 GOOSE message is transmitted over the WAN using the data distribution service (DDS) as a fast, reliable, and secure data-centric communication middleware. The main feature of this framework is its multicast capability, where several authorized subscribers can receive a published message simultaneously. This can significantly improve the system monitoring and control of the protection systems in modern smart grids, where intelligent schemes can be applied. The effectiveness of the proposed platform, in terms of total end-to-end delay between participants, is evaluated through experimental results obtained from the actual hardware-based test setup developed at the Florida International University (FIU) smart grid testbed. The results demonstrate that the latency between sending and receiving a GOOSE message among participants is within its maximum time span defined by the IEC 61850-90-5 working group for communications over the WAN.

42 ENGINEERING↗

Are System Baselines within OT Environments Feasible?

Critical infrastructure stakeholders need to baseline their systems to understand expected protocol communications.Baseline behaviors may vary based on operational context.Expected operations during a maintenance window, for example, may be different from normal operations.Furthermore, constructing system baselines for Industrial Control Systems (ICS) is difficult and time-consuming.ICS processes generate artifacts expressed across heterogeneous data sources such as network and device logs. There needs to be a corpus of data in order to develop and compare methods that evaluate the feasibility, performance, and generality of approaches to construct baselines for ICS events. Standalone repositories of network packet captures are insufficient to develop methods to classify or recognize operational events expressed across multiple data sources. Moreover, static data corpora do not enable researchers to compare the impact of changing the underlying system for which a baseline is being constructed and this limits the ability to evaluate the performance of system baselines given system changes (e.g. patches, configuration, maintenance events). In order to address these limitations within the community, this talk intends to promote discussion about the state of the practice of constructing baselines. In this manner, we can continue to understand requirements within industry that are not being met by current approaches to baseline construction. This talk builds on two previous talks on the topic of system baselines for OT environments. First, Weaver co-presented at the RSA Conference ICS Sandbox with Dan Gunter. The talk confirmed the need within industry to construct baselines across multiple types of data sources relative to the semantics of specific business processes. Second, Weaver presented at IEEE Security and Privacy Workshop on Language-Theoretic Security.

02 PETROLEUM↗

Cybersecurity Resiliency of Marine Renewable Energy Systems Part 2: Cybersecurity Best Practices and Risk Management

Marine renewable energy (MRE) is an emerging source of power for marine applications, marine devices, and coastal communities. This energy source relies on industrial control systems and IT to support operations and maintenance activities, which create a pathway for an adversary to gain unauthorized access to systems and data and disrupt operations. Incorporating cybersecurity risk prevention measures and mitigation capabilities from inception, development, operation, to decommissioning of the MRE system and components is paramount to the protection of energy generation and the security of network architecture and infrastructure. To improve the resilience of MRE systems as a predictable, affordable, and reliable source of energy, cybersecurity guidance was developed to enable operators to assess cybersecurity risks and implement security measures commensurate with the risk. This publication is the second of a two-part series, with Part 1 addressing a framework to determine cybersecurity risk by assessing the vulnerability of an MRE system to potential cyber threats and the consequences a cyberattack would have on the end user. This Part 2 publication describes an approach to select appropriate cybersecurity best practices commensurate with the MRE system's cybersecurity risk. The guidance includes 86 cybersecurity best practices, which are associated with 36 cybersecurity domains and grouped into nine categories. The best practices follow the core functions of the National Institute of Science and Technology Cybersecurity Framework (e.g., identify, detect, protect, respond, and and recover) and insights from both maritime and energy industry guidance documents to identify security measures effective in protecting information and operational technology assets prevalent in MRE systems.

97 MATHEMATICS AND COMPUTING↗

Exe-Guard Project

The exe-Guard Project is an alliance between Dominion Virginia Power (DVP), Sandia National Laboratories (SNL), Dartmouth University, and Schweitzer Engineering Laboratories (SEL). SEL is primary recipient on this project. The exe-Guard project was selected for award under DE-FOA-0000359 with CFDA number 81.122 to address Topic Area of Interest 4: Hardened platforms and Systems. The exe-Guard project developed an antivirus solution for control system embedded devices to prevent the execution of unauthorized code and maintain settings and configuration integrity. This project created a white list antivirus solution for control systems capable of running on embedded Linux® operating systems. White list antivirus methods allow only credible programs to run through the use of digital signatures and hash functions. Once a system’s secure state is baselined, white list antivirus software denies deviations from that state because of the installation of malicious code as this changes hash results. Black list antivirus software has been effective in traditional IT environments but has negative implications for control systems. Black list antivirus uses pattern matching and behavioral analysis to identify system threats while relying on regular updates to the signature file and recurrent system scanning. Black list antivirus is vulnerable to zero day exploits which have not yet been incorporated into a signature file update. System scans hamper the performance of high availability applications, as revealed in NIST special publication 1058 which summarizes the impact of blacklist antivirus on control systems: Manual or “on-demand” scanning has a major effect on control processes in that they take CPU time needed by the control process (Sometimes close to 100% of CPU time). Minimizing the antivirus software throttle setting will reduce but not eliminate this effect. Signature updates can also take up to 100% of CPU time, but for a much shorter period than a typical manual scanning process. Control systems are vulnerable to performance losses if off-the-shelf blacklist antivirus solutions aren’t implemented with care. This investment in configuration in addition to constant decommissioning to perform manual signature file updates is unprecedented and impractical. Additionally, control systems are often disconnected or islanded from the network making the delivery of signature updates difficult. Exe-Guard project developed a white list antivirus solution that mitigated the above drawbacks and allows control systems to cost-effectively apply malware protection while maintaining high reliability. The application of security patches can also be minimized since white listing maintains constant defense against unauthorized code execution. Security patches can instead be applied in less frequent intervals where system decommissioning can be scheduled and planned for. Since control systems are less dynamic than IT environments, the feasibility of maintaining a secure baselined state is more practical. Because upgrades are performed in infrequent, calculated intervals, it allows a new security baseline to be established before the system is returned to service. Exe-Guard built on the efforts of SNL under the Code Seal project. SNL demonstrated prototype Trust Anchors on the project which are independent monitoring and control devices that can be integrated into untrustworthy components. The exe-Guard team started with the lessons learned under this project then designed commercial solution for white list malware protection. Malware is a real threat, even on islanded or un-networked installations, since operators can unintentionally install infected files, plug in infected mass storage devices, or infect a piece of equipment on the islanded local area network that can then spread to other connected equipment. Protection at the device level is one of the last layers of defense in a security-in-depth defense model before an asset becomes compromised. This project provided non-destructive intrusion, isolation and automated response solution, achieving a goal of the Department of Energy (DOE) Roadmap to Secure Control Systems. It also addressed CIP-007-R4 which requires asset owners to employ malicious software prevention tools on assets within the electronic security perimeter. In addition, the CIP-007-R3 requirement for security patch management is minimized because white listing narrows the impact of vulnerabilities and patch releases. The exe-Guard Project completed all tasks identified in the statement of project objective and identified additional tasks within scope that were performed and completed within the original budget. The cost share was met and all deliverables were successfully completed and submitted on time. Most importantly the technology developed and commercialized under this project has been adopted by the Energy sector and thousands of devices with exe-Guard technology integrated in them have now been deployed and are protecting our power systems today

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying Graph Uncertainty from Communication Data

Graphs are a widely used abstraction for representing a variety of important real-world problems including emulating cyber networks for situational awareness, or studying social networks to understand human interactions or pandemic spread. Communication data is often converted into graphs to help understand social and technical patterns in the underlying communication data. However, prior to this project, little work had been performed analyzing how best to develop graphs from such data. Thus, many critical, national security problems were being performed against graph representations of questionable quality. Herein, we describe our analyses that were precursors to our final statistically grounded technique for creating static graph snapshots from a stream of communication events. The first analyzes the statistical distribution properties of a variety of real-world communication datasets generally fit best by Pareto, log normal, and extreme value distributions. The second derives graph properties that can be estimated given the expected statistical distribution for communication events and the communication interval to be viewed node observability, edge observability, and expected accuracy of node degree. Unfortunately, as that final process is under review for publication, we can't publish it here at this time.

97 MATHEMATICS AND COMPUTING↗

Detection of Anomalies in Environmental Gamma Radiation Background with Hopfield Artificial Neural Network - Consortium on Nuclear Security Technologies (CONNECT) Q3 Report

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to investigate performance of a Hopfield Neural Network (HNN) in in detection and identification of weak nuisances and anomalies events in the presence of a highly fluctuating background. Performance of HNN algorithm is benchmarked using search data from an environmental screening campaign. One data set contained a 137 Cs source, and another dataset contained a 131 I source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryptographic Key Management and Critical Risk Assessment

The Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE) CyberSecurity for Energy Delivery Systems (CSEDS) industry led program (DE-FOA-0000359) entitled "Innovation for Increasing CyberSecurity for Energy Delivery Systems (12CSEDS)," awarded a contract to Sypris Electronics LLC to develop a Cryptographic Key Management System for the smart grid (Scalable Key Management Solutions for Critical Infrastructure Protection). Oak Ridge National Laboratory (ORNL) and Sypris Electronics, LLC as a result of that award entered into a CRADA (NFE-11-03562) between ORNL and Sypris Electronics, LLC. ORNL provided its Cyber Security Econometrics System (CSES) as a tool to be modified and used as a metric to address risks and vulnerabilities in the management of cryptographic keys within the Advanced Metering Infrastructure (AMI) domain of the electric sector. ORNL concentrated our analysis on the AMI domain of which the National Electric Sector Cyber security Organization Resource (NESCOR) Working Group 1 (WG1) has documented 29 failure scenarios. The computational infrastructure of this metric involves system stakeholders, security requirements, system components and security threats. To compute this metric, we estimated the stakes that each stakeholder associates with each security requirement, as well as stochastic matrices that represent the probability of a threat to cause a component failure and the probability of a component failure to cause a security requirement violation. We applied this model to estimate the security of the AMI, by leveraging the recently established National Institute of Standards and Technology Interagency Report (NISTIR) 7628 guidelines for smart grid security and the International Electrotechnical Commission (IEC) 63351, Part 9 to identify the life cycle for cryptographic key management, resulting in a vector that assigned to each stakeholder an estimate of their average loss in terms of dollars per day of system operation. To further address probabilities of threats, information security analysis can be performed using game theory implemented in dynamic Agent Based Game Theoretic (ABGT) simulations. Such simulations can be verified with the results from game theory analysis and further used to explore larger scale, real world scenarios involving multiple attackers, defenders, and information assets. The strategy for the game was developed by analyzing five electric sector representative failure scenarios contained in the AMI functional domain from NESCOR WG1. From these five selected scenarios, we characterized them into three specific threat categories affecting confidentiality, integrity and availability (CIA). The analysis using our ABGT simulation demonstrated how to model the AMI functional domain using a set of rationalized game theoretic rules decomposed from the failure scenarios in terms of how those scenarios might impact the AMI network with respect to CIA.

Advanced Metering Infrastructure↗

Trust-Based Detection and Mitigation of Cyber Attacks in Distributed Cooperative Control of Islanded AC Microgrids

In this study, we address the challenge of detecting and mitigating cyber attacks in the distributed cooperative control of islanded AC microgrids, with a particular focus on detecting False Data Injection Attacks (FDIAs), a significant threat to the Smart Grid (SG). The SG integrates traditional power systems with communication networks, creating a complex system with numerous vulnerable links, making it a prime target for cyber attacks. These attacks can lead to the disclosure of private data, control network failures, and even blackouts. Unlike machine learning-based approaches that require extensive datasets and mathematical models dependent on accurate system modeling, our method is free from such dependencies. To enhance the microgrid’s resilience against these threats, we propose a resilient control algorithm by introducing a novel trustworthiness parameter into the traditional cooperative control algorithm. Our method evaluates the trustworthiness of distributed energy resources (DERs) based on their voltage measurements and exchanged information, using Kullback-Leibler (KL) divergence to dynamically adjust control actions. We validated our approach through simulations on both the IEEE-34 bus feeder system with eight DERs and a larger microgrid with twenty-two DERs. The results demonstrated a detection accuracy of around 100%, with millisecond range mitigation time, ensuring rapid system recovery. Additionally, our method improved system stability by up to almost 100% under attack scenarios, showcasing its effectiveness in promptly detecting attacks and maintaining system resilience. These findings highlight the potential of our approach to enhance the security and stability of microgrid systems in the face of cyber threats.

Computer Science↗

Distributed Energy Resource Cybersecurity Framework and Cyber Range Integration

Distributed energy resource (DER) systems feature complex, data-driven communications networks that require careful system coordination and constant vigilance to ensure that grid assets are secure. Because DERs are an important component of the decarbonization strategy, agencies need to secure energy data that could implicate issues of national security if compromised. To help federal energy managers assess, monitor, and manage cybersecurity while achieving decarbonization, the National Renewable Energy Laboratory's (NREL's) Distributed Energy Resource Cybersecurity Framework (DER-CF) offers a comprehensive, web-based assessment tool focusing on cyber governance or policies, technical management, and physical security. The DER-CF currently presents users with a series of pertinent cybersecurity questions that are used to generate a site-specific report and recommendations. This paper outlines a plan to integrate the DER-CF with another key asset-NREL's cyber range-to visualize cybersecurity resilience and compliance and to enhance the usability and accessibility of the DER-CF for federal facility energy managers and planners. This integration will result in a visualization environment to interpret and interact with compliance data. Its development will include regular conversations with stakeholders to assess the effectiveness of these efforts, refine the visualization capability, and ensure its value to our partners.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Maintenance of Maywood Laboratory Operations Support During Contractor Transition and Replacement of the Project Databases - 16329

In December 2013, Cabrera Services (Cabrera) executed transition of the FUSRAP Maywood Superfund Site remediation project operations, including an on-site accredited environmental lab, from a large business that had established technology infrastructure in place for over a decade which required updating to support the expected remediation scope and client needs. As of November 2015, Cabrera has shipped over 116,000 yd{sup 3} of contaminated soil to disposal facilities. During the transition, the USACE FUSRAP Maywood Laboratory (UFML) continued to support project operations, providing the expected timely and reliable results and maintaining their New Jersey Department of Environmental Protection certification for all parameters of concern, while having to cope with new challenges and additional tasks having the potential to disrupt the laboratory's ability to support project operations. This case study examines the challenges with maintaining a certified radiochemistry laboratory and an aggressive remediation schedule during a period of prime contractor transition which included a complete IT infrastructure overhaul, and conversion of the existing Microsoft Access laboratory database and project Electronic Data Management System (EDMS) to a customized commercial solution. Challenges: I. Procurement of a new database subcontractor and working closely with them to achieve the following: a. Migration of all environmental (including radiological, chemical, and quality control), health and safety, and spatial data as well as reports, queries, and analytical instrument software processes from a MS Access data management system to a SQL server system; and b. Verification that the functionality and data integrity of the databases remained intact. II. The onsite laboratory was changed over to a new onsite network and the following tasks were completed with little or no interruption to site operations by January 10, 2014: i. Installation of new instrument personal computers (PCs) and making them fully operational; ii. Configuration of the lab domain and server to host the LIMS (replaced all servers/domain/workstations with Windows 7 and Server 2012 machines). iii. Networking of the laboratory building into the rest of the project site via fiber optic cabling across the site. iv. Upgrade of the wide area network (WAN) data connection to high-speed Fiber Optic service; v. Upgrade of the telephones into voice over internet protocol (VOIP) phones. vi. Splitting of the database into front ends and a centralized back-end hosted on the new server to allow simultaneous access for fixes and improvements. III. Phone service interruption; phone systems were operational by January 10, 2014. Additional Tasks: I. Revision of the USACE FUSRAP Maywood Laboratory (UFML) Quality Systems Manual Rev. 1 Submitted 01/16/14; II. Writing of the Uniform Federal Policy Quality Assurance Project Plan Rev. 1 (UFP-QAPP) submitted 1/21/14. This document replaced the prior project data quality plan, the Chemical Data Quality Management Plan. III. Support of USACE communications to the New Jersey Department of Environmental Protection (NJDEP) on lab management and personnel transition to Cabrera. This work was important since it ensured a smooth transition and shows how critical project records infrastructure such as databases, can be upgraded with minimal interruption of project support. Such work may provide benefit to other similar projects, especially long term projects where database infrastructure upgrades may be beneficial in terms of improved efficiencies in data recording and transfer, and improved security in data storage. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reinforcement Learning for Intentional Islanding in Resilient Power Transmission Systems

Intentional islanding is the process of identifying and deliberately decomposing the transmission network to form self-sustained islands from an endangered network during disruptions to improve resilience and security. Most existing intentional islanding models are offline resilience decision tools and hence do not provide outage responses in a timely manner. In this paper, a reinforcement learning (RL) based model for intentional islanding is developed, which offers real-time switching control, online deployability, and adaptability to varying system conditions. The intentional islanding process is formulated as a Markov decision process, where the optimal transmission switching policy is learned using the RL approach. The control policy is learned over an environment that encompasses a Power System Simulator for Engineering (PSS/E) model of the transmission network, facilitated by an interface to the standard openAI Gym framework. The proposed RL-based methodology aims to form stable and self-sustainable islands by ensuring voltage stability while reducing the power mismatch in the formed islands. A proximal policy optimization algorithm is designed, which is suitable for controlling the on/off status of the switches with multi-layer perceptron as value and actor networks. The effectiveness of the proposed framework in the self-recovery of the grid by island formation is applied on the modified IEEE 39-bus test network and validated by dynamic simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Design and Evaluation of Zero Trust Architecture for Electric Vehicle Charging Infrastructure: EVs @ Scale Series on EV Charging Station Cybersecurity

Implementing a zero trust architecture can significantly bolster the security of electric vehicle (EV) charging infrastructure. EV charging infrastructure includes numerous networked interfaces, each of which can present potential vulnerabilities. When these vulnerabilities are exploited, they can compromise the entire system, leading to severe operational and security risks. Zero trust is a security model that operates on the principle of "never trust, always verify," which helps manage the attack surface and limit the scope of any potential compromises. Fundamentally, this model ensures that no entity, whether inside or outside the network, is trusted by default. The design principles of zero trust include continuous verification, strict deny-by-default access controls, and micro-segmentation. Continuous verification ensures that every request is thoroughly checked, regardless of its origin. Strict access controls enforce the principle of least privilege, allowing users and devices only the minimum necessary access to perform their functions. Micro-segmentation involves dividing the network into smaller, isolated segments to prevent lateral movement in case of a breach. In the context of EV charging infrastructure, zero trust can be implemented through various strategies. For example, multi-factor authentication (MFA) can be required for engineers to access the management interfaces and control systems of charging stations. Real-time monitoring and analysis of network traffic can help detect and respond to anomalies. Systems that do not need to communicate with each other can be micro-segmented to enhance security. All communications should adhere to predefined policies to be permitted. Additionally, encrypting communications can protect sensitive information exchanged between chargers and management systems. This paper presents a zero trust architecture specifically designed for EV charging infrastructure. Implementing zero trust not only mitigates risks but also builds a resilient infrastructure capable of withstanding and quickly recovering from cyber threats. The architecture addresses six defined security objectives. A comprehensive test plan is developed to assess the architecture against these objectives, and the results of the evaluation are reported. This approach is essential for maintaining the reliability and integrity of EV charging services in an increasingly interconnected and vulnerable digital landscape. This is the first in a planned series of papers exploring the implementation of zero trust in EV charging infrastructure. Each paper will delve into different aspects and applications of zero trust, highlighting how various work processes and requirements can lead to distinct architectural designs. These architectures will be tailored to address specific security challenges and operational needs within the EV charging ecosystem, ensuring a robust and adaptable security framework.

33 ADVANCED PROPULSION SYSTEMS↗

Machine Learning Models for Network Traffic Classification in Programmable Logic

Network traffic classification via machine learning on network packet payloads has emerged as an active area of research for network security due to the high accuracy machine learning models have achieved in classifying payloads. For effective deployment as part of network security, these machine learning models must not only classify malicious packet payloads accurately, they must also identify anomalous payloads and perform inference at speeds generally faster than 10,000 packets per second to be effective. This work explores the in- ference speeds and accuracy of several neural network models implemented in programmable logic on various field programmable gate arrays (FPGA) including the Xilinx VC1902 and Xilinx Zynq Ultrascale+. This work also presents the design and performance of both an autoencoder and variational autoencoder programmed on the FPGA for identifying anomalous packet payloads. The performance benefits of the FPGA implementation for this type of packet payload inspection driven by machine learning are compared against graphics processing unit (GPU) inference implementations run on two state-of-the-art datacenter GPU devices, the NVIDIA V100 and A100. The model accuracy difference between the FPGA and GPU implementations was found to be 4% or less while the Xilinx VC1902 outperformed both the NVIDIA V100 and A100 for inference speeds on all the models explored except the variational autoencoder.

97 MATHEMATICS AND COMPUTING↗

The Evolution of Volatile Memory Forensics

The collection and analysis of volatile memory is a vibrant area of research in the cybersecurity community. The ever-evolving and growing threat landscape is trending towards fileless malware, which avoids traditional detection but can be found by examining a system’s random access memory (RAM). Additionally, volatile memory analysis offers great insight into other malicious vectors. It contains fragments of encrypted files’ contents, as well as lists of running processes, imported modules, and network connections, all of which are difficult or impossible to extract from the file system. For these compelling reasons, recent research efforts have focused on the collection of memory snapshots and methods to analyze them for the presence of malware. However, to the best of our knowledge, no current reviews or surveys exist that systematize the research on both memory acquisition and analysis. We fill that gap with this novel survey by exploring the state-of-the-art tools and techniques for volatile memory acquisition and analysis for malware identification. For memory acquisition methods, we explore the trade-offs many techniques make between snapshot quality, performance overhead, and security. For memory analysis, we examined the traditional forensic methods used, including signature-based methods, dynamic methods performed in a sandbox environment, as well as machine learning-based approaches. We summarize the currently available tools, and suggest areas for more research.

Nyholm, Hannah↗

Designing Future Energy Systems with Generative AI

Energy systems are experiencing various changes that impact the distribution, use, and reliability of energy. Local utilities and municipalities must respond and adapt to these changes, moving towards a future energy system with modernized infrastructure and other targeted investments and policy decisions. However, planning for and enacting these advancements requires significant effort from experts and engineers to develop strategies that ensure a reliable and secure energy future. This includes characterizing the current energy infrastructure, identifying areas for development, and engaging with local community members. Emerging generative artificial intelligence techniques can alleviate pain points and help support the development of the next generation of energy systems. Here, in this article, we highlight on-going generative AI work in the areas of atmospheric modeling, building energy management, and distribution network design, and we propose a vision for the role of generative AI that considers opportunities and identifies challenges inherent to this technology.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cyber Security Concerns for Sharing Distributed Antenna Systems

Wireless access to data is a challenge for environments with poor radio frequency coverage such as nuclear power plants. An 802.11 Wi-Fi data network is often not a cost-effective solution not a cost-effective solution due to the requirement for extensive antenna outlays in large nuclear facilities and poor signal penetration due to thick concrete walls. Combining commercial Long-Term Evolution (LTE) with an existing distributed antenna system’s (DAS) resources and infrastructure is an attractive solution due to and lower cost of implementation and likely coverage increases. A 2017 technical report by EPRI has demonstrated that multiple systems such as Land Mobile Radio (LMR) and LTE can be operated using the same DAS and by sharing the leaky coaxial cabling and indoor antenna systems (Reference 1). Since the radio frequency (RF) bands used by the two wireless systems are specified to be non-overlapping, it is believed that the systems are isolated from each other. No extensive analysis has been conducted to determine whether RF signals from one system sharing antennas and coaxial cable can influence another. This paper investigates the assumption of isolation between the two wireless systems and provides recommendations for future needed work to identify specific vulnerabilities and potential mitigations.