Search NASA⌕ Search

SEARCH · Search NASA

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Poster — Thur Eve — 61: A new framework for MPERT plan optimization using MC-DAO

This work combines the inverse planning technique known as Direct Aperture Optimization (DAO) with Intensity Modulated Radiation Therapy (IMRT) and combined electron and photon therapy plans. In particular, determining conditions under which Modulated Photon/Electron Radiation Therapy (MPERT) produces better dose conformality and sparing of organs at risk than traditional IMRT plans is central to the project. Presented here are the materials and methods used to generate and manipulate the DAO procedure. Included is the introduction of a powerful Java-based toolkit, the Aperture-based Monte Carlo (MC) MPERT Optimizer (AMMO), that serves as a framework for optimization and provides streamlined access to underlying particle transport packages. Comparison of the toolkit's dose calculations to those produced by the Eclipse TPS and the demonstration of a preliminary optimization are presented as first benchmarks. Excellent agreement is illustrated between the Eclipse TPS and AMMO for a 6MV photon field. The results of a simple optimization shows the functioning of the optimization framework, while significant research remains to characterize appropriate constraints.

60 APPLIED LIFE SCIENCES↗

SU-E-T-223: Computed Radiography Dose Measurements of External Radiotherapy Beams

Purpose: To obtain quantitative, two-dimensional dose measurements of external radiotherapy beams with a computed radiography (CR) system and to derive volume correction factors for ionization chambers in small fields. Methods: A commercial Kodak ACR2000i CR system with Kodak Flexible Phosphor Screen HR storage foils was used. Suitable measurement conditions and procedures were established. Several corrections were derived, including image fading, length-scale corrections and long-term stability corrections. Dose calibration curves were obtained for cobalt, 4 MV, 8 MV and 25 MV photons, and for 10 MeV, 15 MeV and 18 MeV electrons in a water phantom. Inherent measurement inhomogeneities were studied as well as directional dependence of the response. Finally, 2D scans with ionization chambers were directly compared to CR measurements, and volume correction factors were derived. Results: Dose calibration curves (0.01 Gy to 7 Gy) were obtained for multiple photon and electron beam qualities. For each beam quality, the calibration curves can be described by a single fit equation over the whole dose range. The energy dependence of the dose response was determined. The length scale on the images was adjusted scan-by-scan, typically by 2 percent horizontally and by 3 percent vertically. The remaining inhomogeneities after the system’s standard calibration procedure were corrected for. After correction, the homogeneity is on the order of a few percent. The storage foils can be rotated by up to 30 degrees without a significant effect on the measured signal. First results on the determination of volume correction factors were obtained. Conclusion: With CR, quantitative, two-dimensional dose measurements with a high spatial resolution (sub-mm) can be obtained over a large dose range. In order to make use of these advantages, several calibrations, corrections and supporting measurements are needed. This work was funded by the European Metrology Research Programme (EMRP) project HLT09 MetrExtRT Metrology for Radiotherapy using Complex Radiation Fields.

60 APPLIED LIFE SCIENCES↗

A Computuerized Operator Support System Prototype

A report was published by the Idaho National Laboratory in September of 2012, entitled Design to Achieve Fault Tolerance and Resilience, which described the benefits of automating operator actions for transients. The report identified situations in which providing additional automation in lieu of operator actions would be advantageous. It recognized that managing certain plant upsets is sometimes limited by the operator’s ability to quickly diagnose the fault and to take the needed actions in the time available. Undoubtedly, technology is underutilized in the nuclear power industry for operator assistance during plant faults and operating transients. In contrast, other industry sectors have amply demonstrated that various forms of operator advisory systems can enhance operator performance while maintaining the role and responsibility of the operator as the independent and ultimate decision-maker. A computerized operator support system (COSS) is proposed for use in nuclear power plants to assist control room operators in addressing time-critical plant upsets. A COSS is a collection of technologies to assist operators in monitoring overall plant performance and making timely, informed decisions on appropriate control actions for the projected plant condition. The COSS does not supplant the role of the operator, but rather provides rapid assessments, computations, and recommendations to reduce workload and augment operator judgment and decision-making during fast-moving, complex events. This project proposes a general model for a control room COSS that addresses a sequence of general tasks required to manage any plant upset: detection, validation, diagnosis, recommendation, monitoring, and recovery. The model serves as a framework for assembling a set of technologies that can be interrelated to assist with each of these tasks. A prototype COSS has been developed in order to demonstrate the concept and provide a test bed for further research. The prototype is based on four underlying elements consisting of a digital alarm system, computer-based procedures, PI&D system representations, and a recommender module for mitigation actions. At this point, the prototype simulates an interface to a sensor validation module and a fault diagnosis module. These two modules will be fully integrated in the next version of the prototype. The initial version of the prototype is now operational at the Idaho National Laboratory using the U.S. Department of Energy’s Light Water Reactor Sustainability (LWRS) Human Systems Simulation Laboratory (HSSL). The HSSL is a full-scope, full-scale glass top simulator capable of simulating existing and future nuclear power plant main control rooms. The COSS is interfaced to the Generic Pressurized Water Reactor (gPWR) simulator with industry-typical control board layouts. The glass top panels display realistic images of the control boards that can be operated by touch gestures. A section of the simulated control board was dedicated to the COSS human-system interface (HSI), which resulted in a seamless integration of the COSS into the normal control room environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Computuerized Operator Support System Prototype

A report was published by the Idaho National Laboratory in September of 2012, entitled Design to Achieve Fault Tolerance and Resilience, which described the benefits of automating operator actions for transients. The report identified situations in which providing additional automation in lieu of operator actions would be advantageous. It recognized that managing certain plant upsets is sometimes limited by the operator’s ability to quickly diagnose the fault and to take the needed actions in the time available. Undoubtedly, technology is underutilized in the nuclear power industry for operator assistance during plant faults and operating transients. In contrast, other industry sectors have amply demonstrated that various forms of operator advisory systems can enhance operator performance while maintaining the role and responsibility of the operator as the independent and ultimate decision-maker. A computerized operator support system (COSS) is proposed for use in nuclear power plants to assist control room operators in addressing time-critical plant upsets. A COSS is a collection of technologies to assist operators in monitoring overall plant performance and making timely, informed decisions on appropriate control actions for the projected plant condition. The COSS does not supplant the role of the operator, but rather provides rapid assessments, computations, and recommendations to reduce workload and augment operator judgment and decision-making during fast-moving, complex events. This project proposes a general model for a control room COSS that addresses a sequence of general tasks required to manage any plant upset: detection, validation, diagnosis, recommendation, monitoring, and recovery. The model serves as a framework for assembling a set of technologies that can be interrelated to assist with each of these tasks. A prototype COSS has been developed in order to demonstrate the concept and provide a test bed for further research. The prototype is based on four underlying elements consisting of a digital alarm system, computer-based procedures, PI&D system representations, and a recommender module for mitigation actions. At this point, the prototype simulates an interface to a sensor validation module and a fault diagnosis module. These two modules will be fully integrated in the next version of the prototype. The initial version of the prototype is now operational at the Idaho National Laboratory using the U.S. Department of Energy’s Light Water Reactor Sustainability (LWRS) Human Systems Simulation Laboratory (HSSL). The HSSL is a full-scope, full-scale glass top simulator capable of simulating existing and future nuclear power plant main control rooms. The COSS is interfaced to the Generic Pressurized Water Reactor (gPWR) simulator with industry-typical control board layouts. The glass top panels display realistic images of the control boards that can be operated by touch gestures. A section of the simulated control board was dedicated to the COSS human-system interface (HSI), which resulted in a seamless integration of the COSS into the normal control room environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Amplatzer Vascular Plugs Versus Coils for Embolization of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia

PurposeCoil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia.MethodsThe study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004–2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both), and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher’s exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05.Results16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4–18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413).ConclusionThe use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robotically Assisted CBCT-Guided Needle Insertions: Preliminary Results in a Phantom Model

Aim: To compare robotic-assisted needle insertions performed under CBCT guidance to standard manual needle insertions. Materials and Methods: A homemade robotic prototype was used by two operators to perform robotic and manual needle insertions on a custom-made phantom. Both the operators had no experience with the prototype before starting the trial. The primary endpoint was accuracy (i.e., the minimal distance between the needle tip and the center of the target) between robotic and manual insertions. Secondary endpoints included total procedure time and operators’ radiation exposure. The Wilcoxon test was used. A p value less than 0.05 was considered statistically significant. Results: Thirty-three (17 manual, 16 robotic) needle insertions were performed. Mean accuracy for robotic insertion was 2.3 ± 0.9 mm (median 2.1; range 0.8–4.2) versus 2.3 ± 1 mm (median 2.1; range 0.7–4.4) for manual insertion (p = 0.84). Mean procedure time was 683 ± 57 s (median 670; range 611–849) for the robotic group versus 552 ± 40 s (median 548; range 486–621) for the manual group (p = 0.0002). Mean radiation exposure was 3.25 times less for the robotic insertion on comparison to manual insertion for the operator 1 (0.4 vs 1.3 µGy); and 4.15 times less for the operator 2 (1.9 vs 7.9 µGy). Conclusion: The tested robotic prototype showed accuracy comparable to that achieved with manual punctures coupled to a significant reduction of operators’ radiation exposure. Further, in vivo studies are necessary to confirm the efficiency of the system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EFFECT OF MODEL-DEPENDENT COVARIANCE MATRIX FOR STUDYING BARYON ACOUSTIC OSCILLATIONS

Large-scale structures in the universe are a powerful tool to test cosmological models and constrain cosmological parameters. A particular feature of interest comes from baryon acoustic oscillations (BAOs), which are sound waves traveling in the hot plasma of the early universe that stopped at the recombination time. This feature can be observed as a localized bump in the correlation function at the scale of the sound horizon r{sub s} . As such, it provides a standard ruler and a lot of constraining power in the correlation function analysis of galaxy surveys. Moreover, the detection of BAOs at the expected scale gives strong support to cosmological models. Both of these studies (BAO detection and parameter constraints) rely on a statistical modeling of the measured correlation function {xi}-circumflex. Usually {xi}-circumflex is assumed to be Gaussian, with a mean {xi}{sub {theta}} depending on the cosmological model and a covariance matrix C generally approximated as a constant (i.e., independent of the model). In this article, we study whether a realistic model-dependent C {sub {theta}} changes the results of cosmological parameter constraints compared to the approximation of a constant covariance matrix C. For this purpose, we use a new procedure to generate lognormal realizations of the luminous red galaxy sample of the Sloan Digital Sky Survey Data Release 7 to obtain a model-dependent C {sub {theta}} in a reasonable time. The approximation of C {sub {theta}} as a constant creates small changes in the cosmological parameter constraints on our sample. We quantify this modeling error using a lot of simulations and find that it only has a marginal influence on cosmological parameter constraints for current and next-generation galaxy surveys. It can be approximately taken into account by extending the 1{sigma} intervals by a factor Almost-Equal-To 1.3.

79 ASTRONOMY AND ASTROPHYSICS↗

A neural-network based estimator to search for primordial non-Gaussianity in Planck CMB maps

We present an upgraded combined estimator, based on Minkowski Functionals and Neural Networks, with excellent performance in detecting primordial non-Gaussianity in simulated maps that also contain a weighted mixture of Galactic contaminations, besides real pixel's noise from Planck cosmic microwave background radiation data. We rigorously test the efficiency of our estimator considering several plausible scenarios for residual non-Gaussianities in the foreground-cleaned Planck maps, with the intuition to optimize the training procedure of the Neural Network to discriminate between contaminations with primordial and secondary non-Gaussian signatures. We look for constraints of primordial local non-Gaussianity at large angular scales in the foreground-cleaned Planck maps. For the SMICA map we found f{sub NL} = 33 ± 23, at 1σ confidence level, in excellent agreement with the WMAP-9yr and Planck results. In addition, for the other three Planck maps we obtain similar constraints with values in the interval f{sub NL} element of [33, 41], concomitant with the fact that these maps manifest distinct features in reported analyses, like having different pixel's noise intensities.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-368: Improved HPGe Detector Precise Efficiency Calibration with Monte Carlo Simulations and Radioactive Sources

Purpose: To obtain an improved precise gamma efficiency calibration curve of HPGe (High Purity Germanium) detector with a new comprehensive approach. Methods: Both of radioactive sources and Monte Carlo simulation (CYLTRAN) are used to determine HPGe gamma efficiency for energy range of 0–8 MeV. The HPGe is a GMX coaxial 280 cm{sup 3} N-type 70% gamma detector. Using Momentum Achromat Recoil Spectrometer (MARS) at the K500 superconducting cyclotron of Texas A&M University, the radioactive nucleus {sup 24} Al was produced and separated. This nucleus has positron decays followed by gamma transitions up to 8 MeV from {sup 24} Mg excited states which is used to do HPGe efficiency calibration. Results: With {sup 24} Al gamma energy spectrum up to 8MeV, the efficiency for γ ray 7.07 MeV at 4.9 cm distance away from the radioactive source {sup 24} Al was obtained at a value of 0.194(4)%, by carefully considering various factors such as positron annihilation, peak summing effect, beta detector efficiency and internal conversion effect. The Monte Carlo simulation (CYLTRAN) gave a value of 0.189%, which was in agreement with the experimental measurements. Applying to different energy points, then a precise efficiency calibration curve of HPGe detector up to 7.07 MeV at 4.9 cm distance away from the source {sup 24} Al was obtained. Using the same data analysis procedure, the efficiency for the 7.07 MeV gamma ray at 15.1 cm from the source {sup 24} Al was obtained at a value of 0.0387(6)%. MC simulation got a similar value of 0.0395%. This discrepancy led us to assign an uncertainty of 3% to the efficiency at 15.1 cm up to 7.07 MeV. The MC calculations also reproduced the intensity of observed single-and double-escape peaks, providing that the effects of positron annihilation-in-flight were incorporated. Conclusion: The precision improved gamma efficiency calibration curve provides more accurate radiation detection and dose calculation for cancer radiotherapy treatment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interstellar hydrogen fluxes measured by IBEX-LO in 2009: Numerical modeling and comparison with the data

In this paper, we perform numerical modeling of the interstellar hydrogen fluxes measured by IBEX-Lo during orbit 23 (spring 2009) using a state-of-the-art kinetic model of the interstellar neutral hydrogen distribution in the heliosphere. This model takes into account the temporal and heliolatitudinal variations of the solar parameters as well as the non-Maxwellian kinetic properties of the hydrogen distribution due to charge exchange in the heliospheric interface. We found that there is a qualitative difference between the IBEX-Lo data and the modeling results obtained with the three-dimensional, time-dependent model. Namely, the model predicts a larger count rate in energy bin 2 (20–41 eV) than in energy bin 1 (11–21 eV), while the data shows the opposite case. We perform study of the model parameter effects on the IBEX-Lo fluxes and the ratio of fluxes in two energy channels. We show that the most important parameter, which has a major influence on the ratio of the fluxes in the two energy bins, is the solar radiation pressure. The parameter fitting procedure shows that the best agreement between the model result and the data occurs when the ratio of the solar radiation pressure to the solar gravitation, μ{sub 0}, is 1.26{sub −0.076}{sup +0.06}, and the total ionization rate of hydrogen at 1 AU is β{sub E,0}=3.7{sub −0.35}{sup +0.39}×10{sup −7} s{sup −1}. We have found that the value of μ{sub 0} is much larger than μ{sub 0} = 0.89, which is the value derived from the integrated solar Lyα flux data for the period of time studied. We discuss possible reasons for the differences.

79 ASTRONOMY AND ASTROPHYSICS↗

Uncertainty Quantification and Comparison of Weld Residual Stress Measurements and Predictions.

In pressurized water reactors, the prevention, detection, and repair of cracks within dissimilar metal welds is essential to ensure proper plant functionality and safety. Weld residual stresses, which are difficult to model and cannot be directly measured, contribute to the formation and growth of cracks due to primary water stress corrosion cracking. Additionally, the uncertainty in weld residual stress measurements and modeling predictions is not well understood, further complicating the prediction of crack evolution. The purpose of this document is to develop methodology to quantify the uncertainty associated with weld residual stress that can be applied to modeling predictions and experimental measurements. Ultimately, the results can be used to assess the current state of uncertainty and to build confidence in both modeling and experimental procedures. The methodology consists of statistically modeling the variation in the weld residual stress profiles using functional data analysis techniques. Uncertainty is quantified using statistical bounds (e.g. confidence and tolerance bounds) constructed with a semi-parametric bootstrap procedure. Such bounds describe the range in which quantities of interest, such as means, are expected to lie as evidenced by the data. The methodology is extended to provide direct comparisons between experimental measurements and modeling predictions by constructing statistical confidence bounds for the average difference between the two quantities. The statistical bounds on the average difference can be used to assess the level of agreement between measurements and predictions. The methodology is applied to experimental measurements of residual stress obtained using two strain relief measurement methods and predictions from seven finite element models developed by different organizations during a round robin study.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Parametric Reconstruction of Glass Fiber-reinforced Polymer Composites from X-ray Projection Data—A Simulation Study

We present a new approach to estimate geometry parameters of glass fibers in glass fiber-reinforced polymers from simulated X-ray micro-computed tomography scans. Traditionally, these parameters are estimated using a multi-step procedure including image reconstruction, pre-processing, segmentation and analysis of features of interest. Each step in this chain introduces errors that propagate through the pipeline and impair the accuracy of the estimated parameters. In the approach presented in this paper, we reconstruct volumes from a low number of projection angles using an iterative reconstruction technique and then estimate position, direction and length of the contained fibers incorporating a priori knowledge about their shape, modeled as a geometric representation, which is then optimized. Using simulation experiments, we show that our method can estimate those representations even in presence of noisy data and only very few projection angles available.

42 ENGINEERING↗

Transarterial Embolization of Anomalous Systemic Arterial Supply to Normal Basal Segments of the Lung

PurposeTo evaluate transarterial embolization (TAE) for the management of anomalous systemic arterial (ASA) supply to normal basal segments of the lung.MethodsThirteen patients with ASA supply to normal basal segments of the lung underwent TAE. All patients presented with hemoptysis and had complete-type anomalies on pre-TAE or post-TAE computed tomography (CT). The anomaly was unilateral in all patients; 11 lesions were located in the left lung and 2 in the right. All patients underwent embolization with coils (n = 10) or a vascular plug (n = 3). Procedural success, clinical efficacy, and complications were assessed. Mean post-TAE CT and clinical follow-up was 25.4 and 42.1 months, respectively.ResultsTechnical success was achieved in 100 % of cases. Several changes were noted on follow-up CT: complete obstruction of the ASA in all cases, normal (n = 11) or decreased (n = 2) density of the affected lung parenchyma, reduction of the primary enlarged inferior pulmonary vein in all cases, and pulmonary infarction and thickening of the corresponding bronchial artery (n = 4). The main complication was pulmonary infarction in four cases.ConclusionTAE is a safe, effective, and minimally invasive therapeutic option for patients with ASA supply to normal basal segments of the lung.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MVP™ Micro Vascular Plug Systems for the Treatment of Pulmonary Arteriovenous Malformations

Purpose: To describe our institutional experience with MVP™ micro vascular plug systems for the treatment of pulmonary arteriovenous malformations (PAVMs). Materials and Methods: We performed a retrospective medical record review of 52 patients with 119 PAVMs treated exclusively with MVP™ systems (69 procedures/153 MVP™ systems) between July 2014 and July 2018. All patients had PAVMs with feeding artery diameters ≥ 2 mm. MVP™ systems were deployed according to physician preference. We collected patient demographic information; procedural data (including size of feeding artery, size and number of embolics used per PAVM, fluoroscopy time, contrast administration), technical success rates, complications, and persistence. Persistence was assessed using computed tomography angiography (CTA) performed 1–3 months and 3–5 years after embolization per clinical protocol. Results: All procedures were technically successful without major complications. Mean feeding artery diameter was 3.3 ± 1.2 mm. Mean fluoroscopy time per procedure and contrast volume administered per procedure were 35 ± 16 min and 217 ± 101 mL, respectively. A mean of 1.3 ± 0.8 MVP™ systems was used per PAVM. There were no instances of persistence during a mean follow-up time of 328 ± 258 days (range 26 to 914 days). Conclusions: For PAVMs with feeding artery diameters of 2 to 7.9 mm (mean 3.3 ± 1.2 mm), MVP™ systems are safe and effective given their high technical success rates and lack of persistence. Further prospective work will be required to elucidate the advantages and disadvantages of these MVP™ systems for PAVM embolization. Level of Evidence: Level III.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Mutual Awareness in Analog vs. Digital Control Rooms

Control rooms in nuclear power plants are complex, collaborative working environments rife with potential for human error. As control rooms evolve from analog to digital interface environments, crew communication strategies must change as well. Operators in the analog control room operate the plant and communicate with each other with the help of control boards with large control panels, meters, and switches. Reactor operators could choose a particular set of controls on the particular control board which corresponds to the part of the system of interest. Visual display units (VDU), which became a fixture in the control rooms with the shift to digital human-machine interfaces (HMI), bring benefits for safety and flexibility combining information from various sources. With the increase in automation and the use of digital HMIs operators received their personal sitting workstations where they are able to navigate and operate the plant. The amount of information increased as well as the complexity of monitoring and analyzing the system states. Also computerized systems cause operators to get absorbed by their personal screens and reduce interaction between the crew members. Therefore, the collaboration and coordination of task demands requires vigilance and mutual awareness. The level of automation has an influence on the level of mutual awareness experienced by operators in the control rooms. Teams function to carry out highly interdependent tasks, requiring synthesis and sharing of information to achieve common goals. Improving the performance of the team necessitates the operators to focus on the system, the surrounding environment, and situational awareness about the system states. Collaboration of team members is critical when employing the digital operating systems as the acute awareness of the overall progress of the group and individual activities of the operators drives the team to the desired end-states of the plant operations. Out-of-the loop (OOTL) performance problems can be referred to as the lack of supervisory control, system monitoring, and information processing in the digital HMIs. Under some circumstances Senior Reactor Operators (SRO) struggle to follow the actions of other Reactor Operators (RO) because with the new digital interfaces SROs lose track of how the procedures are carried out by ROs, which results in the loss of three way communication. Mutual awareness plays a significant role in keeping the SROs in the loop of plant operations. This paper will investigate, through literature review and expert interviews, the impact and human errors attributed to the increasing complexity of new digital main control rooms. Comparison of the new digital interfaces with the analog interfaces in nuclear power plants has the potential to shed light on increasing mutual awareness and three way communications between the SROs and ROs. Further, identification of the human errors and human actions can provide beneficial information, suggesting significant and critical improvements that can be implemented in the main control rooms to increase safety and reliability of new technology. Additionally, insights on mutual awareness for analog vs. digital control rooms can serve to improve human reliability.

99 GENERAL AND MISCELLANEOUS↗

Innovative diffraction gratings for high-resolution resonant inelastic soft x-ray scattering spectroscopy

High-resolution Resonant Inelastic X-ray Scattering (RIXS) requires diffraction gratings with very exacting characteristics. The gratings should provide both very high dispersion and high efficiency which are conflicting requirements and extremely challenging to satisfy in the soft x-ray region for a traditional grazing incidence geometry. To achieve high dispersion one should increase the groove density of a grating; this however results in a diffraction angle beyond the critical angle range and results in drastic efficiency loss. The problem can be solved by use of multilayer coated blazed gratings (MBG). In this work we have investigated the diffraction characteristics of MBGs via numerical simulations and have developed a procedure for optimization of grating design for a multiplexed high resolution imaging spectrometer for RIXS spectroscopy to be built in sector 6 at the Advanced Light Source (ALS). We found that highest diffraction efficiency can be achieved for gratings optimized for 4{sup th} or 5{sup th} order operation. Fabrication of such gratings is an extremely challenging technological problem. We present a first experimental prototype of these gratings and report its performance. High order and high line density gratings have the potential to be a revolutionary new optical element that should have great impact in the area of soft x-ray RIXS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seed Placement in Permanent Breast Seed Implant Brachytherapy: Are Concerns Over Accuracy Valid?

Purpose: To evaluate seed placement accuracy in permanent breast seed implant brachytherapy (PBSI), to identify any systematic errors and evaluate their effect on dosimetry. Methods and Materials: Treatment plans and postimplant computed tomography scans for 20 PBSI patients were spatially registered and used to evaluate differences between planned and implanted seed positions, termed seed displacements. For each patient, the mean total and directional seed displacements were determined in both standard room coordinates and in needle coordinates relative to needle insertion angle. Seeds were labeled according to their proximity to the anatomy within the breast, to evaluate the influence of anatomic regions on seed placement. Dosimetry within an evaluative target volume (seroma + 5 mm), skin, breast, and ribs was evaluated to determine the impact of seed placement on the treatment. Results: The overall mean (±SD) difference between implanted and planned positions was 9 ± 5 mm for the aggregate seed population. No significant systematic directional displacements were observed for this whole population. However, for individual patients, systematic displacements were observed, implying that intrapatient offsets occur during the procedure. Mean displacements for seeds in the different anatomic areas were not found to be significantly different from the mean for the entire seed population. However, small directional trends were observed within the anatomy, potentially indicating some bias in the delivery. Despite observed differences between the planned and implanted seed positions, the median (range) V{sub 90} for the 20 patients was 97% (66%-100%), and acceptable dosimetry was achieved for critical structures. Conclusions: No significant trends or systematic errors were observed in the placement of seeds in PBSI, including seeds implanted directly into the seroma. Recorded seed displacements may be related to intrapatient setup adjustments. Despite observed seed displacements, acceptable postimplant dosimetry was achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A benchmark concept for simulation in radiographic testing

The new standard ISO 17636–2:2013 “NDT of welds: Radiographic testing - Part 2: X- and gamma ray techniques with digital detectors” describes a complex procedure for film replacement by phosphor imaging plates and digital detector arrays. RT modeling software should consider these detector types, X-ray film, and the standard requirements for image quality. Practitioners expect the same visibility of image quality indicators (IQI) in the simulated radiographs as in the experimental exposures. The proposed benchmark test is based on the comparison of experimental radiographs taken at BAM with modeled ones of participants. The experimental setup and the determination of the equivalent penetrameter sensitivity (EPS) as described in the procedure of ASTM E 746 are used for quantitative evaluation of the achievable contrast sensitivity for step hole IQIs as considered in Annex B of ISO 17636–2. System classification data for Computed Radiography (CR) and film systems will be provided by BAM according to ISO 11699–1 for selected film systems and according to ASTM E 2446 for selected CR systems. The classification of films and digital detectors is based on the measurement of the dose response function, the basic spatial resolution (SR{sub b}) of the image, and the measured image noise, which depends on the detector efficiency, the quantum statistics, and the detector fixed pattern noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗