Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuous flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

A Mechanical Test Frame for Property Evaluations at Cryogenic Temperature

On-board storage of hydrogen fuel has been designated as a limiting factor in the advancement of fuel cell technologies in the automotive industry. The use of cryo-compressed Type III pressure vessels presents one option to overcome this barrier. These multi-material vessels will be expected to perform at high pressure and extreme low temperatures, which creates a complex engineering design challenge. Many materials exhibit highly temperature-dependent properties, which must be considered for the efficient design of cryo-compressed pressure vessels. Complicating this issue, mechanical property data at cryogenic temperatures is sparse. This technical paper provides a description of a test apparatus commissioned specifically to help address this shortcoming. A mechanical test frame was retrofitted with a continuous flow cryostat capable to evaluate various mechanical properties throughout a broad temperature range of 25 °C to -269 °C with a load limit of 10 kN. An investigation of the thermomechanical properties of an epoxy resin was carried out as a demonstration.

Mechanical characterization, cryogenic pressure ve↗

Oscillating heat pipe integrated thermal management system for power electronics

Disclosed is a thermal management system for removing heat from a power electronic heat source, the system comprising: a base plate having a plurality of fluid passages there through and extending between and inlet side of the base plate and an outlet side of the base plate; and a plurality of heat transfer pipe segments respectively attached to one or more of the plurality of fluid passages at the inlet side of the base plate and the outlet side of the base plate, the plurality of heat transfer pipe segments arranged adjacent one another, the plurality of heat transfer pipe segments containing a two-phase working fluid, and the plurality of heat transfer pipe segments forming a continuous flow path through and back into the base plate for the two-phase working fluid.

Wang, Jim↗

Process and apparatus for continuous production of porous structures

An apparatus and process are presented for continuous production of metal-based micro-porous structures of pore sizes from 0.3 nm to 5.0 μm from a green part of characteristic diffusion mass transfer dimension less than 1 mm through chemical reactions in a continuous flow of gas substantially free of oxygen. The produced micro-porous structures include i) thin porous metal sheets of thickness less than 200 μm and pore sizes in the range of 0.1 to 5.0 μm, ii) porous ceramic coating of thickness less than 40 μm and ceramic particle sizes of 200 nm or less on a porous metal-based support structures of pore sizes in the range of 0.1 to 5 μm.

Liu, Wei↗

Development of an In Situ Fission Gas Release Instrument for Fuel Sample Irradiations in the High Flux Isotope Reactor

Experimental measurement of gaseous fission product release with respect to temperature and burnup is a critical aspect of understanding nuclear fuel performance, validating predictive models, and qualifying new fuels. To measure this phenomenon in real-time, Oak Ridge National Laboratory has developed an instrument for measuring in situ fission gas release from small-scale fuel samples irradiated in the High Flux Isotope Reactor (HFIR). The instrument uses a continuous flow of Heover the fuel samples to sweep gaseous fission products from a sealed capsule in the HFIR Be reflector to an instrument station adjacent to the reactor. The instrument station houses two high-purity germanium (HPGe) detectors that measure decay gamma rays from fission products passing through a room temperature dwell chamber placed over the detector crystal. The sealed capsules in the reactor are designed to modulate fuel sample temperatures between 700 and 1,100°C by changing the Ar/He gas mixture surrounding the capsules during irradiation. N-type thermocouples are incorporated into the capsule housing to record real-time fuel temperatures. The capsules are heated primarily by prompt gamma rays emitted from the HFIR core with minimal heat contributions from fission in the fuel samples to minimize temperature gradients in the specimens for separate-effects characterization of the material. This paper describes modeling of time-dependent nuclear heating and fission product formation in fuel samples, thermal characteristics of the in-core capsules, and expected gaseous fission product gamma spectra at the HPGe instrument station.

Mulligan, Padhraic L [ORNL] (ORCID:000000025826540↗

Geomechanical and flow implications with continued bioconversion of coal to methane: Experiments and modeling

Microbial conversion of coal to methane is a promising technology during transition of coal-based energy from conventional coal mining to natural gas recovery from coal. Significant research advances have been made towards engineering ideal microbial communities and nutrients for bio-stimulation of coal. However, actual field applications require geomechanical and flow behavior characterization of coal during the bioconversion process as well as gas production over the life of the created “biogenic gas reservoirs”. This work presents the results of an experimental investigation to estimate gas/methane production using bioconversion of coal and analyses of variations in bulk modulus, strain and permeability. Bulk modulus of coal demonstrated time-dependent behavior with continued bioconversion of solid coal. The phenomenon was modeled using mass balancing in a closed environment and the logistic equation based biogenic gas production with time. The modeled gas production and changes in modulus of coal showed excellent agreement with the corresponding experimental results. Next, numerical simulation of biogenic conversion of coal in a constant stress in-situ condition, replicating the Huff ‘n Puff method under field conditions, was carried out. The results showed that bioconversion can lead to decrease in effective stress, increase in permeability and decrease in the modulus of coal with time. Repeated recharge of coal with nutrients and recovering the produced gas, that is, sequential cycles of Huff n’ Puff, showed further increase in permeability and decrease in coal strength, potentially leading to coal failure in-situ, further increasing the permeability, thus enhancing the prospect of field application of the technology.

01 COAL, LIGNITE, AND PEAT↗

Reference document for LANL stack sampling and ANSI N13.1 (Article) Gielow RL and McNamee MR 1993. Numerical Flue Gas Flow Modeling for Continuous Emissions Monitoring Applications. EPRI CEM Users Group Meeting. Baltimore. RP1961-13

American National Standard N13.1 “sets forth guidelines and performance criteria for sampling the emissions of airborne radioactive substances in the air discharge ducts and stacks of nuclear facilities. Emphasis is on extractive sampling from a location in a stack or duct where the contaminant is well mixed. At such a location, sampling may be conducted at a single point. This standard provides performance-based criteria for the use of air sampling probes, transport lines, sample collectors, sample monitoring instruments, and gas flow measuring methods. This standard also covers sampling program objectives, quality assurance issues, developing air sampling action levels, system optimization, and system performance verification. Workplace, containment, and environmental air monitoring are not addressed. Specific sample analysis methods and the reporting or interpreting of results are also not addressed.” (HPS 2011).

61 RADIATION PROTECTION AND DOSIMETRY↗

Theoretical Review of the MFIX Fluid and Two-Fluid Models

MFIX (Multiphase Flow with Interphase eXchanges) is a general purpose code that can be used for describing the hydrodynamics, chemical reactions, and heat transfer of dense or dilute multiphase fluid flows. MFIX calculations give detailed information on pressure, temperature, composition, and velocity distributions in the defined system. This report provides an overview of MFIX’s expressions for single phase flow and continuous dispersed multiphase flow (i.e., the two-fluid model). In addition to the two fluid model (MFIX-TFM), MFIX contains a discrete element model (MFIX-DEM) and a multi-phase particle in cell model (MFIX-PIC) that are not reviewed within this document.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A stroboscopic technique for using CCD cameras in flow visualization systems for continuous viewing and stop action photography

A technique for synchronizing a pulse light source to charge coupled device cameras is presented. The technique permits the use of pulse light sources for continuous as well as stop action flow visualization. The technique has eliminated the need to provide separate lighting systems at facilities requiring continuous and stop action viewing or photography.

Franke, John M.↗

Fluid flow stimulates rapid and continuous release of nitric oxide in osteoblasts

Interstitial fluid flow may mediate skeletal remodeling in response to mechanical loading. Because nitric oxide (NO) has been shown to be an osteoblast mitogen and inhibitor of osteoclastic resorption, we investigated and characterized the role of fluid shear on the release of NO in osteoblasts. Rat calvarial cells in a stationary culture produced undetectable levels of NO. Fluid shear stress (6 dyn/cm2) rapidly increased NO release rate to 9.8 nmol.h-1.mg protein-1 and sustained this production for 12 h of exposure to flow. Cytokine treatment also induced NO synthesis after a 12-h lag phase of zero production, followed by a production rate of 0.6 nmol.h-1.mg protein-1. Flow-induced NO production was blocked by the NO synthase (NOS) inhibitor NG-amino-L-arginine, but not by dexamethasone, which suggests that the flow stimulated a constitutive NOS isoform. This is the first time that a functional constitutively present NOS isoform has been identified in osteoblasts. Moreover, fluid flow represents the most potent stimulus of NO release in osteoblasts reported to date. Fluid flow-induced NO production may therefore play a primary role in bone maintenance and remodeling.

NASA Discipline Cell Biology↗

Effect of Gravity on the Near Field Flow Structure of Helium Jet in Air

Experiments have shown that a low-density jet injected into a high-density surrounding medium undergoes periodic oscillations in the near field. Although the flow oscillations in these jets at Richardson numbers about unity are attributed to the buoyancy, the direct physical evidence has not been acquired in the experiments. If the instability were indeed caused by buoyancy, the near-field flow structure would undergo drastic changes upon removal of gravity in the microgravity environment. The present study was conducted to investigate this effect by simulating microgravity environment in the 2.2-second drop tower at the NASA Glenn Research Center. The non-intrusive, rainbow schlieren deflectometry technique was used for quantitative measurements of helium concentrations in buoyant and non-buoyant jets. Results in a steady jet show that the radial growth of the jet shear layer in Earth gravity is hindered by the buoyant acceleration. The jet in microgravity was 30 to 70 percent wider than that in Earth gravity. The microgravity jet showed typical growth of a constant density jet shear layer. In case of a self-excited helium jet in Earth gravity, the flow oscillations continued as the jet flow adjusted to microgravity conditions in the drop tower. The flow oscillations were however not present at the end of the drop when steady microgravity conditions were reached.

Agrawal, Ajay K.↗

Continuous method for preparing carbonate esters

In one embodiment, a continuous process for preparing organic carbonate solvent of Formula (I) as described herein comprises contacting a first reactant (an alcohol) with a reactive carbonyl source (carbonyldiimidazole (CDI) or an alkylchloroformate) in the presence of a catalyst in reaction stream flowing through a continuous flow reactor at temperature 20° C. to about 160° C. and at a flow rate providing a residence time in the range of about 0.1 minute to about 24 hours; collecting a reactor effluent exiting from the continuous flow reactor; recovering a crude product from the reactor effluent; and distilling the crude product to obtain the organic carbonate compound of Formula (I). In another embodiment, the first reactant is an epoxide and the carbonyl source is carbon dioxide.

Dzwiniel, Trevor L.↗

Continuous method for preparing carbonate esters

In one embodiment, a continuous process for preparing organic carbonate solvent of Formula (I) as described herein comprises contacting a first reactant (an alcohol) with a reactive carbonyl source (carbonyldiimidazole (CDI) or an alkylchloroformate) in the presence of a catalyst in reaction stream flowing through a continuous flow reactor at temperature 20° C. to about 160° C. and at a flow rate providing a residence time in the range of about 0.1 minute to about 24 hours; collecting a reactor effluent exiting from the continuous flow reactor; recovering a crude product from the reactor effluent; and distilling the crude product to obtain the organic carbonate compound of Formula (I). In another embodiment, the first reactant is an epoxide and the carbonyl source is carbon dioxide.

Dzwiniel, Trevor L.↗

Tactile display device using an electrorheological fluid

A tactile display device utilizes an electrorheological fluid to activate a plurality of tactile dots. A voltage is selectively produced uniformly across an electrorheological fluid flowing between a common ground electrode and a plurality of conductive dot electrodes, thereby producing an increase in the fluid's viscosity to the extent that fluid flow between the two electrodes is restricted. The flow restriction produces a build-up of electrorheological fluid in a corresponding dot actuator chamber. The resulting pressure increase in the chamber displaces an elastic diaphragm fixed to a display surface to form a lump which can be perceived by the reader as one dot in a Braille character cell. A flow regulation system provides a continually pressurized flow system and provides for free flow of the electrorheological fluid through the plurality of dot actuator chambers when they are not activated. The device is adaptable to printed circuit techniques and can simultaneously display tactile dots representative of a full page of Braille characters stored on a medium such as a tape cassette or to display tactile dots representative of non-Braille data appearing on a computer monitor or contained on another data storage medium. In an alternate embodiment, the elastic diaphragm drives a plurality of spring-loaded pins provided with positive stops to maintain consistent displacements of the pins in both their actuated and nonactuated positions.

Garner, H. Douglas↗

Method and device for producing a tactile display using an electrorheological fluid

A tactile display device utilizes an electrorheological fluid to activate a plurality of tactile dots. A voltage is selectively produced uniformly across an electrorheological fluid flowing between a common ground electrode and a plurality of conductive dot electrodes, thereby producing an increase in the fluid's viscosity to the extent that fluid flow between the two electrodes is restricted. The flow restriction produces a build-up of electrorheological fluid in a corresponding dot actuator chamber. The resulting pressure increase in the chamber displaces an elastic diaphragm fixed to a display surface to form a lump which can be perceived by the reader as one dot in a Braille character cell. A flow regulation system provides a continually pressurized flow system and provides for free flow of the electrorheological fluid through the plurality of dot actuator chambers when they are not activated. The device is adaptable to printed circuit techniques and can simultaneously display tactile dots representative of a full page of Braille characters stored on a medium such as a tape cassette or to display tactile dots representative of non-Braille data appearing on a computer monitor or contained on another data storage medium. In an alternate embodiment, the elastic diaphragm drives a plurality of spring-loaded pins provided with positive stops to maintain consistent displacements of the pins in both their actuated and nonactuated positions.

Garner, H. Douglas↗

The Recent Improvements of the SNS Extraction Kicker Power Supplies

A total of 14 extraction kickers., with one as the hot spare., are in service to extract protons out of the storage ring at the SNS. The jitter issue and the short lifetime of the switches were resolved after the thyratrons were replaced with solid state switches in 2018. This paper discusses the recent improvements. Two thyristor switches suffered overheating damage in separate incidents. One was due to the oil pump failure and the other was the result of a disconnected oil hose. An ultrasonic flow meter and a fiber optic temperature monitoring system have been installed for each extraction kicker power supply. The flow meter continuously monitors the entire tank oil flow. The temperature monitor detects the thyristor switch real-time temperatures in three locations. Fault thresholds are selected so that the thyristor switches are protected from overheating damage. Alarms are configured to alert staff to take actions before faults occur. In addition., the cause of an intermittent misfire issue was identified, and the solution was implemented. Lastly., a future oscilloscope upgrade and an oil level sensor are discussed.

Tan, Yugang↗

The effects of forced air flow and oxygen concentration on flammability, smoke density, and pyrolytic toxicity

The question is posed whether forced air flow should be incorporated into flammability tests as a relevant variable. A test apparatus is described which permits tests to be conducted on small test specimens in a forced flow which is (continuously) variable over flow velocities from zero to 300 feet per minute (1.52 m/s). The effects of air-flow rate and oxygen concentration on flame propagation rate, maximum smoke density, and pyrolytic product toxicity were measured for a single material and were statistically evaluated. Regression analysis was used to graph the resulting relationships. It is concluded that air velocity is an important variable for laboratory flammability testing.

Sauers, D. G.↗

Pump, and earth-testable spacecraft capillary heat transport loop using augmentation pump and check valves

A spacecraft includes heat-generating payload equipment, and a heat transport system with a cold plate thermally coupled to the equipment and a capillary-wick evaporator, for evaporating coolant liquid to cool the equipment. The coolant vapor is coupled to a condenser and in a loop back to the evaporator. A heated coolant reservoir is coupled to the loop for pressure control. If the wick is not wetted, heat transfer will not begin or continue. A pair of check valves are coupled in the loop, and the heater is cycled for augmentation pumping of coolant to and from the reservoir. This augmentation pumping, in conjunction with the check valves, wets the wick. The wick liquid storage capacity allows the augmentation pump to provide continuous pulsed liquid flow to assure continuous vapor transport and a continuously operating heat transport system. The check valves are of the ball type to assure maximum reliability. However, any type of check valve can be used, including designs which are preloaded in the closed position. The check valve may use any ball or poppet material which resists corrosion. For optimum performance during testing on Earth, the ball or poppet would have neutral buoyancy or be configured in a closed position when the heat transport system is not operating. The ball may be porous to allow passage of coolant vapor.

Baker, David↗