At least 505 records · Page 28

Phase-Field Modeling of Materials Interfaces and Nanostructures

Nanostructured materials offer unique properties for a wide range of energy applications. Among various known processing methods, liquid metal dealloying (LMD)—the selective dissolution of a base alloy element into a metallic melt—has emerged as a powerful technique to produce a new class of nano-/meso-scale open porous and bicontinuous composite structures with ultra-high interfacial area. LMD has recently been complemented by the advent of vapor phase dealloying (VPD), a novel technique that exploits the selective evaporation of one element from a parent alloy containing elements with very different vapor pressures, thereby enabling to fabricate open nanoporous structures of various elements from less-noble metals to inorganic elements regardless of their chemical activity without requiring high LMD temperatures and chemical etching. Together LMD and VPD have greatly expanded the scope of dealloying techniques, limited by traditional electrochemical means to noble metals, and boosted the design of new functional and structural materials that combine a wide variety of elements. Topologically-connected open porous structures with ultra-high surface area allow mass transport within the structure while preserving structural integrity, enabling them to serve as catalysts, fuel cells, supercapacitors, or high-capacity battery materials. Bicontinuous composite structures in turn can display high strength and high ductility or superior radiation-damage resistance due to the ultra-high interface area between interpenetrating solid phases. This research program makes use of state-of-the-art computational methods to understand at a basic level the self-organizing dealloying process with main focus on dealloying kinetics and interfacial pattern formation at the dealloying front controlling initial structure size, topology, and phase compositions. Phase-field simulation studies of LMD focus on solid solutions, line compounds, and intermetallic systems that can form ternary composites by nucleation and growth of a new phase. Studies of VPD employ phase-field modeling and a hybrid method combining a kinetic Monte Carlo (KMC) model of evaporation and surface diffusion with molecular dynamics for vapor-phase transport inside nanopores. Simulations explore mechanisms of interface- and diffusion-controlled dealloying kinetics, both observed in VPD but not fundamentally understood. In addition, our newly developed multi-physics phase-field approach of large-volume-change phase transformations is being used to model novel 3D anode geometries based on dealloyed nanoporous structures including novel sandwiched graphene/Si/silica for highrate Li ion battery. Those studies are aimed at elucidating geometric design principles that improve mechanical stability. We expect this research to enhance the capability to tailor nano-/mesoscale structures for a wide range of energy-related materials applications and to yield further advances in computational methodologies that benefit a broad materials research community.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ultra-compact and efficient heat exchanger for solar desalination with unprecedented scaling resistance

The objective is to design, prototype, and test a heat exchanger technology with an efficiency improvement of more than 150% compared to state-of-the-art heat exchanger technology (UA/volume), with significantly improved fouling/scaling resistance at elevated temperatures (>120°C) when compared to existing technology where scaling is a major performance-limiting issue, as well as at lower operating-temperatures (~63-110°C). We now report our overall progress on the project. An ultra-compact, efficient heat exchanger geometry has been developed that can maximize surface-area-to-volume ratio so that proposed target (UA/volume). Advanced manufacturing techniques, such additive manufacturing, have made it possible to create complex structures cost effectively. In addition to traditional manufacturing methods, additive manufacturing has been successfully used for the development of high-performance geometries. These methods allow the ability to create custom surface textures, which are deployed to dramatically control wettability and create energy-gradient surfaces. These techniques allow fouling/scaling nucleation to be spatially controlled, such that as the fouling layer grows it will be broken and removed by flow forces.

42 ENGINEERING↗

Automated gas burette system for evolved hydrogen measurements

This paper reports a simple and efficient gas burette system that allows automated determination of evolved gas volume in real time using only temperature and pressure measurements. The system is reliable and has been used successfully to study the hydrogen release kinetics of ammonia borane thermolysis. The system is especially suitable for bench scale studies involving small batches and potentially rapid reaction kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Results From a Prospective Study Using Limited Margin Radiotherapy in Pediatric and Young Adult Patients With High-Grade Nonrhabdomyosarcoma Soft-Tissue Sarcoma

Purpose: To demonstrate the safety and efficacy of limited margin radiotherapy in the local control of pediatric and young adult patients with high-grade nonrhabdomyosarcoma soft tissue sarcoma (NRSTS). Methods and Materials: Pediatric patients with high-grade NRSTS requiring radiation were treated on an institutional review board approved prospective institutional study of conformal/intensity-modulated/interstitial brachytherapy using a 2-cm anatomically constrained margin. Results: A total of 32 patients (median age, 15.3 years; range, 2-22 years) received adjuvant (27 patients) or definitive (5 patients) irradiation. With a median follow-up of 32 months, the 3-year cumulative incidence of local failure was 3.7% for patients undergoing irradiation after surgical resection. Four patients experienced local failure; the mean dose to the volume of recurrence was >=97% of the prescribed dose. Conclusions: Delivery of limited margin radiotherapy using external beam or brachytherapy provides a high rate of local tumor control without marginal failure. Further follow-up is required to determine whether normal tissue effects are minimized using this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adjuvant Stereotactic Radiosurgery After Resection of Intracranial Hemangiopericytomas

Purpose: To evaluate adjuvant stereotactic radiosurgery (SRS) in the management of recurrent or residual intracranial hemangiopericytomas (HPCs), we assessed tumor control, survival, and complications in patients who had undergone gamma knife SRS as part of multimodal therapy. Methods and Materials: We retrospectively reviewed the records of consecutive 20 HPC patients who had undergone SRS for 29 tumors. The median patient age was 51.5 years (range, 8.9-80.2). All patients had undergone previous surgical resection of their tumors. In addition, 12 patients underwent fractionated radiotherapy before SRS. Of the 20 patients, 16 patients had low-grade HPCs (20 tumors) and 4 had high-grade anaplastic HPCs (9 tumors). The median radiosurgery target volume was 4.5 cm{sup 3} (range, 0.07-34.3), and the median marginal dose was 15.0 Gy (range, 10-20). Results: At an average of 48.2 months (range, 7.2-124.1), 5 patients had died of metastases and 3 patients had died of disease progression. The overall survival after radiosurgery was 100%, 85.9%, and 13.8% at 1, 5, and 10 years, respectively. The follow-up imaging studies demonstrated tumor control in 21 (72.4%) of 29 tumors. The progression-free survival rate after SRS at 1, 3, and 5 years was 89.1% for low-grade HPCs and 88.9%, 66.7%, and 0%, respectively, for high-grade HPCs. The factors associated with improved progression-free survival included lower grade and higher marginal dose. Eight patients had intracranial or extracranial metastasis after the initial diagnosis, which correlated with the shorter survival. Conclusion: The results of our study have shown that adjuvant SRS after tumor resection is an important management option for patients with residual or recurrent HPCs and is particularly effective for less-aggressive tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cervical Lymph Node Metastases From Unknown Primary Cancer: A Single-Institution Experience With Intensity-Modulated Radiotherapy

Purpose: To determine the effectiveness and rate of complications of intensity-modulated radiotherapy (IMRT) in the treatment of cervical lymph node metastases from unknown primary cancer. Methods and Materials: Between February 2005 and November 2008, 25 patients with an unknown primary cancer underwent IMRT, with a median radiation dose of 70 Gy. The bilateral neck and ipsilateral putative pharyngeal mucosa were included in the target volume. All patients had squamous cell carcinoma, except for 1 patient who had adenosquamous differentiation. They were all treated with curative intent. Of the 25 included patients, 20 were men and 5 were women, with a median age of 54 years. Of these patients, 3 had Stage III, 18 had Stage IVa, and 4 had Stage IVb. Of the 25 patients, 18 (72%) received platinum-based chemotherapy in a combined-modality setting. Neck dissection was reserved for residual disease after definitive IMRT. Overall survival, disease-free survival, and locoregional control were calculated using the Kaplan-Meier method. Results: With a median follow-up of 38 months, the overall survival, disease-free survival, and locoregional control rates were all 100% at 3 years. No occurrence of primary cancer was observed during the follow-up period. The reported rates of xerostomia reduced with the interval from the completion of treatment. Nine patients (36%) reported Grade 2 or greater xerostomia at 6 months, and only 2 (8%) of them reported the same grade of salivary function toxicity after 24 months of follow-up. Conclusion: In our institution, IMRT for unknown primary cancer has provided good overall and disease-free survival in all the patients with an acceptable rate of complications. IMRT allowed us to address the bilateral neck and ipsilateral putative pharyngeal mucosa with minimal late salivary function toxicity. The use of concurrent chemotherapy and IMRT for more advanced disease led to good clinical results with reasonable toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Micropillar compression technique applied to micron-scale mudstone elasto-plastic deformation.

Mudstone mechanical testing is often limited by poor core recovery and sample size, preservation and preparation issues, which can lead to sampling bias, damage, and time-dependent effects. A micropillar compression technique, originally developed by Uchic et al. 2004, here is applied to elasto-plastic deformation of small volumes of mudstone, in the range of cubic microns. This study examines behavior of the Gothic shale, the basal unit of the Ismay zone of the Pennsylvanian Paradox Formation and potential shale gas play in southeastern Utah, USA. Precision manufacture of micropillars 5 microns in diameter and 10 microns in length are prepared using an ion-milling method. Characterization of samples is carried out using: dual focused ion - scanning electron beam imaging of nano-scaled pores and distribution of matrix clay and quartz, as well as pore-filling organics; laser scanning confocal (LSCM) 3D imaging of natural fractures; and gas permeability, among other techniques. Compression testing of micropillars under load control is performed using two different nanoindenter techniques. Deformation of 0.5 cm in diameter by 1 cm in length cores is carried out and visualized by a microscope loading stage and laser scanning confocal microscopy. Axisymmetric multistage compression testing and multi-stress path testing is carried out using 2.54 cm plugs. Discussion of results addresses size of representative elementary volumes applicable to continuum-scale mudstone deformation, anisotropy, and size-scale plasticity effects. Other issues include fabrication-induced damage, alignment, and influence of substrate.

03 NATURAL GAS↗

Generation of Large-Volume High-Pressure Plasma by Spatio-Temporal Control of Space Charge

Due to the fundamental limitations of scaling, very little progress has been made towards achieving a large-volume dense non-equilibrium plasma near atmospheric pressures. Commercially available state-of-the art glow-like atmospheric plasma devices for industrial applications are either narrow tubes or wide slits with narrow openings. Often multiple sources are put together in various configurations to process larger surfaces. The traditional methods of exciting electrodes create spatially fixed electric fields. As a result, the space charge at atmospheric pressure tends to be spatially confined resulting in non-uniformity which eventually leads to instability as the discharge is scaled. Theoretical work done under this project showed that it is possible to generate a spatially rotating electric field by exciting a set of electrodes with phase staggered sinusoidal waveforms. The modeling and simulations were done using plasma fluid models. It was shown that such a field can produce a uniform plasma. At the conclusion of the project, experimental proof of concept with an eight-electrode system in various gases (Air, Helium and Argon) was demonstrated. Power measurements and spectral investigation show that the concept can be used to generate a uniform stable plasma. This plasma source has the potential of opening new applications of nonthermal plasma including combustion of carbon-free fuel. The current limitation of the proposed method in scaling to higher volume and pressure is the need for multiple high voltage amplifiers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Controlling sign problems in spin models using tensor renormalization

We consider the sign problem for classical spin models at complex $\beta =1/g_0^2$ on $L\times L$ lattices. We show that the tensor renormalization group method allows reliable calculations for larger Im$\beta$ than the reweighting Monte Carlo method. For the Ising model with complex $\beta$ we compare our results with the exact Onsager-Kaufman solution at finite volume. The Fisher zeros can be determined precisely with the TRG method. We check the convergence of the TRG method for the O(2) model on $L\times L$ lattices when the number of states $D_s$ increases. We show that the finite size scaling of the calculated Fisher zeros agrees very well with the Kosterlitz-Thouless transition assumption and predict the locations for larger volume. The location of these zeros agree with Monte Carlo reweighting calculation for small volume. The application of the method for the O(2) model with a chemical potential is briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

System and method for computed axial lithography (CAL) for 3D additive manufacturing

In one aspect the present disclosure relates to a system for forming a three dimensional (3D) object from a volume of photo-responsive material contained within a material container. A plurality of optical projection subsystems are adapted to be arranged at least partially circumferentially around a material container containing the volume of photo-responsive material, and are controlled by a controller. The optical projection subsystems direct optical projections at a plurality of angles θ through the volume of photo-responsive material. The optical projections are further directed about a z axis extending through the volume of photo-responsive material. The plurality of optical subsystems are further controlled by the controller to provide each of the optical projections with a calculated three-dimensional intensity distribution acting over a fixed temporal exposure period, which is sufficient to at least one of cure or remove selected portions of the volume of photo-responsive material, and leave other portions unmodified, to form a desired 3D part.

Kelly, Brett↗

Accumulated Delivered Dose Response of Stereotactic Body Radiation Therapy for Liver Metastases

Purpose: To determine whether the accumulated dose using image guided radiation therapy is a stronger predictor of clinical outcomes than the planned dose in stereotactic body radiation therapy (SBRT) for liver metastases. Methods and Materials: From 2003 to 2009, 81 patients with 142 metastases were treated in institutional review board–approved SBRT studies (5-10 fractions). Patients were treated during free breathing (with or without abdominal compression) or with controlled exhale breath-holding. SBRT was planned on a static exhale computed tomography (CT) scan, and the minimum planning target volume dose to 0.5 cm{sup 3} (minPTV) was recorded. The accumulated minimum dose to the 0.5 cm{sup 3} gross tumor volume (accGTV) was calculated after performing dose accumulation from exported image guided radiation therapy data sets registered to the planning CT using rigid (2-dimensional MV/kV orthogonal) or deformable (3-dimensional/4-dimensional cone beam CT) image registration. Univariate and multivariate Cox regression models assessed the factors influencing the time to local progression (TTLP). Hazard ratios for accGTV and minPTV were compared using model goodness-of-fit and bootstrapping. Results: Overall, the accGTV dose exceeded the minPTV dose in 98% of the lesions. For 5 to 6 fractions, accGTV doses of >45 Gy were associated with 1-year local control of 86%. On univariate analysis, the cancer subtype (breast), smaller tumor volume, and increased dose were significant predictors for improved TTLP. The dose and volume were uncorrelated; the accGTV dose and minPTV dose were correlated and were tested separately on multivariate models. Breast cancer subtype, accGTV dose (P<.001), and minPTV dose (P=.02) retained significance in the multivariate models. The univariate hazard ratio for TTLP for 5-Gy increases in accGTV versus minPTV was 0.67 versus 0.74 (all patients; 95% confidence interval of difference 0.03-0.14). Goodness-of-fit testing confirmed the accGTV dose as a stronger dose–response predictor than the minPTV dose. Conclusions: The accGTV dose is a better predictor of TTLP than the minPTV dose for liver metastasis SBRT. The use of modern image guided radiation therapy in future analyses of dose–response outcomes should increase the concordance between the planned and delivered doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

One-pot synthesis of co-substituted manganese oxide nanosheets and physical properties of lamellar aggregates

Graphical abstract: Display Omitted Highlights: ► Solid solution nanosheets, (Mn{sub 1−x}Co{sub x})O{sub 2}, synthesized via facile one-pot process. ► The structural characterization of nanosheets revealing a single (Mn,Co)O{sub 2} layer and the solubility limit as x ∼ 0.20. ► The invariant charge density of the layer upon Co substitution. ► Systematic dependence of magnetic and optical properties of the lamellar aggregates. -- Abstract: Co-substituted manganese oxide nanosheets, (Mn{sub 1−x}Co{sub x})O{sub 2} have been synthesized in the form of a colloidal suspension via a simple one-pot method. Substitution effects on the structural, optical absorption, and magnetic properties are investigated for the nanosheets and their lamellar aggregates. The composition of the (Mn{sub 1−x}Co{sub x})O{sub 2} nanosheets can be controlled continuously by adjusting the molar ratio of the starting materials. The solubility limit is x ∼ 0.20 based on the cell volume. In the 0.00 ≤ x ≤ 0.20 range, the band gap energy, magnetic moment, and Weiss temperature change systematically with x. The charge density of the (Mn,Co)O{sub 2} layer is independent of x (i.e., [(Mn,Co)O{sub 2}]{sup 0.2−}) and the cobalt ions are trivalent in low-spin state.

36 MATERIALS SCIENCE↗

THE COYOTE UNIVERSE. I. PRECISION DETERMINATION OF THE NONLINEAR MATTER POWER SPECTRUM

Near-future cosmological observations targeted at investigations of dark energy pose stringent requirements on the accuracy of theoretical predictions for the nonlinear clustering of matter. Currently, N-body simulations comprise the only viable approach to this problem. In this paper, we study various sources of computational error and methods to control them. By applying our methodology to a large suite of cosmological simulations we show that results for the (gravity-only) nonlinear matter power spectrum can be obtained at 1% accuracy out to k {approx} 1 h Mpc{sup -1}. The key components of these high accuracy simulations are precise initial conditions, very large simulation volumes, sufficient mass resolution, and accurate time stepping. This paper is the first in a series of three; the final aim is a high-accuracy prediction scheme for the nonlinear matter power spectrum that improves current fitting formulae by an order of magnitude.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-454: Impact of Calculation Grid Size On Dosimetry and Radiobiological Parameters for Head and Neck IMRT

Purpose: IMRT has become standard of care for complex treatments to optimize dose to target and spare normal tissues. However, the impact of calculation grid size is not widely known especially dose distribution, tumor control probability (TCP) and normal tissue complication probability (NTCP) which is investigated in this study. Methods: Ten head and neck IMRT patients treated with 6 MV photons were chosen for this study. Using Eclipse TPS, treatment plans were generated for different grid sizes in the range 1–5 mm for the same optimization criterion with specific dose-volume constraints. The dose volume histogram (DVH) was calculated for all IMRT plans and dosimetric data were compared. ICRU-83 dose points such as D2%, D50%, D98%, as well as the homogeneity and conformity indices (HI, CI) were calculated. In addition, TCP and NTCP were calculated from DVH data. Results: The PTV mean dose and TCP decreases with increasing grid size with an average decrease in mean dose by 2% and TCP by 3% respectively. Increasing grid size from 1–5 mm grid size, the average mean dose and NTCP for left parotid was increased by 6.0% and 8.0% respectively. Similar patterns were observed for other OARs such as cochlea, parotids and spinal cord. The HI increases up to 60% and CI decreases on average by 3.5% between 1 and 5 mm grid that resulted in decreased TCP and increased NTCP values. The number of points meeting the gamma criteria of ±3% dose difference and ±3mm DTA was higher with a 1 mm on average (97.2%) than with a 5 mm grid (91.3%). Conclusion: A smaller calculation grid provides superior dosimetry with improved TCP and reduced NTCP values. The effect is more pronounced for smaller OARs. Thus, the smallest possible grid size should be used for accurate dose calculation especially in H and N planning.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-J-01: Dosimetric Effects of HU Changes During the Course of Proton Therapy for Lung Cancer

Purpose: To characterize the changes in Hounsfield unit (HU) in lung radiotherapy with proton beams during the course of treatment and to study the effect on the proton plan dose distribution. Methods: Twenty consecutive patients with non-small cell lung cancer treated with proton radiotherapy who underwent multiple CT scans including the planning CT and weekly verification CTs were studied. HU histograms were computed for irradiated lung volumes in beam paths for all scans using the same treatment plan. Histograms for un-irradiated lung volume were used as control to characterize inter-scan variations. HU statistics were calculated for both irradiated and un-irradiated lung volumes for each patient scan. Further, multiple CT scans based on the same planning CT were generated by replacing the HU of the lung based on the verification CT scans HU values. Using the same beam arrangement, we created plans for each of the altered CT scans to study the dosimetric effect using the dose volume histogram. Results: Lung HU decreased for irradiated lung volume during the course of radiotherapy. The magnitude of this change increased with total irradiation dose. On average, HU changed by −53.8 in the irradiated volume. This change resulted in less than 0.5mm of beam overshoot in tissue for every 1cm beam traversed in the irradiated lung. The dose modification is about +3% for the lung, and less than +1% for the primary tumor. Conclusion: HU of the lung decrease throughout the course of radiation therapy. This change results in a beam overshoot (e.g. 3mm for 6cm of lung traversed) and causes a small dose modification in the overall plan. However, this overshoot does not affect the quality of plans since the margins used in planning, based on proton range uncertainty, are greater. HU needs to change by 150 units before re-planning is warranted.

60 APPLIED LIFE SCIENCES↗

Reverse-Mode Algorithmic Differentiation of an OpenMP-Parallel Compressible Flow Solver

y Reverse-mode algorithmic differentiation (AD) is an established method for obtaining adjoint derivatives of computer simulation applications. In computational fluid dynamics (CFD), adjoint derivatives of a cost function output such as drag or lift with respect to design parameters such as surface coordinates or geometry control points are a key ingredient for shape optimization, uncertainty quantification and flow control. The computational cost of CFD applications and their derivatives makes it essential to use high-performance computing hardware efficiently, including multi- and many-core architectures. Nevertheless, OpenMP is not supported in most AD tools, and previously shown methods achieve poor scalability of the derivative code. We present the AD of an OpenMP-parallelized finite volume compressible flow solver for unstructured meshes. Our approach enables us to reuse the parallelization of the original code in the computation of adjoint derivatives. The method works by identifying code segments that can be differentiated in reverse-mode without changing their memory access pattern. The OpenMP parallelization is integrated into the derivative code during the build process in a way that is robust to modifications of the original code and independent of the OpenMP support of the differentiation tool. We show the scalability of our adjoint CFD solver on test cases ranging from thousands to millions of finite volume mesh cells on CPUs with up to 16 threads as well as on an Intel XeonPhi card with 236 threads. We demonstrate that our approach is more practical to implement for production-sized CFD codes and produces more efficient adjoint derivative code than previously shown AD methods.

Huckelheim, Jan↗

Near-IR absorption in high-purity photothermorefractive glass and holographic optical elements: measurement and application for high-energy lasers

Volume Bragg gratings (VBGs) in photothermorefractive (PTR) glass are widely used for laser beam control including high-power laser systems. Among them, spectral beam combining based on VBGs is one of the most promising. Achieving 100+ kW of combined laser beams requires the development of PTR glass and VBGs with an extremely low absorption coefficient and therefore methods of its measurement. This paper describes the calorimetric method that was developed for measuring a low absorption coefficient in PTR glass and VBGs. It is based on transmission monitoring of the intrinsic Fabry-Perot interferometer produced by the plane-parallel surfaces of the measured optical elements when heated by high-power laser radiation. An absorption coefficient at 1085 nm as low as 5x10{sup -5} cm{sup -1} is demonstrated in pristine PTR glass while an absorption coefficient as low as 1x10{sup -4} cm{sup -1} is measured in high-efficiency reflecting Bragg gratings with highest purity. The actual level of absorption in PTR glass allows laser beam control at the 10 kW level, while the 100 kW level would require active cooling and/or decreasing the absorption in PTR Bragg gratings to a value similar to that in virgin PTR glass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Fifth International Workshop on Ice Nucleation phase 2 (FIN-02): laboratory intercomparison of ice nucleation measurements

Abstract. The second phase of the Fifth International Ice Nucleation Workshop (FIN-02)involved the gathering of a large number of researchers at the KarlsruheInstitute of Technology's Aerosol Interactions and Dynamics of the Atmosphere(AIDA) facility to promote characterization and understanding of icenucleation measurements made by a variety of methods used worldwide.Compared to the previous workshop in 2007, participation was doubled,reflecting a vibrant research area. Experimental methods involved sampling ofaerosol particles by direct processing ice nucleation measuring systems fromthe same volume of air in separate experiments using different ice nucleatingparticle (INP) types, and collections of aerosol particle samples ontofilters or into liquid for sharing amongst measurement techniques thatpost-process these samples. In this manner, any errors introduced bydifferences in generation methods when samples are shared across laboratorieswere mitigated. Furthermore, as much as possible, aerosol particle sizedistribution was controlled so that the size limitations of different methodswere minimized. The results presented here use data from the workshop toassess the comparability of immersion freezing measurement methods activatingINPs in bulk suspensions, methods that activate INPs in condensation and/orimmersion freezing modes as single particles on a substrate, continuous flowdiffusion chambers (CFDCs) directly sampling and processing particles wellabove water saturation to maximize immersion and subsequent freezing ofaerosol particles, and expansion cloud chamber simulations in which liquidcloud droplets were first activated on aerosol particles prior to freezing.The AIDA expansion chamber measurements are expected to be the closestrepresentation to INP activation in atmospheric cloud parcels in thesecomparisons, due to exposing particles freely to adiabatic cooling. The different particle types used as INPs included the minerals illite NX andpotassium feldspar (K-feldspar), two natural soil dusts representative of arable sandy loam(Argentina) and highly erodible sandy dryland (Tunisia) soils, respectively,and a bacterial INP (Snomax ® ). Consideredtogether, the agreement among post-processed immersion freezing measurementsof the numbers and fractions of particles active at different temperaturesfollowing bulk collection of particles into liquid was excellent, withpossible temperature uncertainties inferred to be a key factor in determiningINP uncertainties. Collection onto filters for rinsing versus directly intoliquid in impingers made little difference. For methods that activatedcollected single particles on a substrate at a controlled humidity at orabove water saturation, agreement with immersion freezing methods was good inmost cases, but was biased low in a few others for reasons that have not beenresolved, but could relate to water vapor competition effects. AmongstCFDC-style instruments, various factors requiring (variable) highersupersaturations to achieve equivalent immersion freezing activation dominatethe uncertainty between these measurements, and for comparison with bulkimmersion freezing methods. When operated above water saturation to includeassessment of immersion freezing, CFDC measurements often measured at orabove the upper bound of immersion freezing device measurements, but oftenunderestimated INP concentration in comparison to an immersion freezingmethod that first activates all particles into liquid droplets prior tocooling (the PIMCA-PINC device, or Portable Immersion Mode Cooling chAmber–Portable Ice Nucleation Chamber), and typically slightly underestimated INPnumber concentrations in comparison to cloud parcel expansions in the AIDAchamber; this can be largely mitigated when it is possible to raise therelative humidity to sufficiently high values in the CFDCs, although this isnot always possible operationally. Correspondence of measurements of INPs among direct sampling andpost-processing systems varied depending on the INP type. Agreement was bestfor Snomax ® particles in the temperature regimecolder than −10 ∘ C, where their ice nucleation activity is nearlymaximized and changes very little with temperature. At temperatures warmer than −10 ∘ C, Snomax ® INP measurements (allvia freezing of suspensions) demonstrated discrepancies consistent withprevious reports of the instability of its protein aggregates that appear tomake it less suitable as a calibration INP at these temperatures. ForArgentinian soil dust particles, there was excellent agreement across allmeasurement methods; measures ranged within 1 order of magnitude for INPnumber concentrations, active fractions and calculated active site densitiesover a 25 to 30 ∘ C range and 5 to 8 orders of correspondingmagnitude change in number concentrations. This was also the case for alltemperatures warmer than −25 ∘ C in Tunisian dust experiments. Incontrast, discrepancies in measurements of INP concentrations or active sitedensities that exceeded 2 orders of magnitude across a broad range of temperaturemeasurements found at temperatures warmer than −25 ∘ C in a previous study werereplicated for illite NX. Discrepancies also exceeded 2 orders of magnitude attemperatures of −20 to −25 ∘ C for potassium feldspar (K-feldspar), but these coincidedwith the range of temperatures at which INP concentrations increase rapidly atapproximately an order of magnitude per 2 ∘ C cooling forK-feldspar. These few discrepancies did not outweigh the overall positive outcomes of theworkshop activity, nor the future utility of this data set or future similarefforts for resolving remaining measurement issues. Measurements of the samematerials were repeatable over the time of the workshop and demonstratedstrong consistency with prior studies, as reflected by agreement of databroadly with parameterizations of different specific or general (e.g., soildust) aerosol types. The divergent measurements of the INP activity of illiteNX by direct versus post-processing methods were not repeated for otherparticle types, and the Snomax ® datademonstrated that, at least for a biological INP type, there is no expectedmeasurement bias between bulk collection and direct immediately processedfreezing methods to as warm as −10 ∘ C. Since particle size rangeswere limited for this workshop, it can be expected that for atmosphericpopulations of INPs, measurement discrepancies will appear due to thedifferent capabilities of methods for sampling the full aerosol sizedistribution, or due to limitations on achieving sufficient watersupersaturations to fully capture immersion freezing in direct processinginstruments. Overall, this workshop presents an improved picture of presentcapabilities for measuring INPs than in past workshops, and providesdirection toward addressing remaining measurement issues.

54 ENVIRONMENTAL SCIENCES↗