Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Homogenization of time series from Portugal and its former colonies for the period from the late 19th to the early 21st century

Here, three homogenization software packages – AnClim, RhTestsV3 and HOMER – have been applied to monthly and annual temperature and pressure series from Portugal and its ex-colonies in Africa and Asia to detect non-climatic breaks. Homogenization tests in both absolute and relative mode were performed with an a posteriori statistical assessment to select the most probable breakpoints. Time series from neighbouring stations as well as reanalyses data were used as reference series. The reanalyses data sets were used due to lack of suitable neighbouring stations and also to test reanalyses as proxy data. A list of probable shifts is produced and will be used to support future global reanalyses. Moreover, temperature and pressure series were adjusted using adjustment factors that were obtained by calculating the difference between certain periods before and after the breaks. The accuracy of the adjusted series was verified subjectively (visually) and objectively using three verification techniques: correlation coefficient, central root-mean-square error and standard deviation. A positive impact of the applied adjustment in terms of all three scores was reflected in a majority of cases.

abrupt breaks↗

Advantages of a variable‐resolution global climate model in reproducing the seasonal evolution of East Asian summer monsoon

Abstract The East Asian summer monsoon (EASM) is unique among monsoon systems that it features meridional evolution of the summer monsoon. In this study, we evaluate the performances of a Variable‐Resolution Community Earth System Model (VR‐CESM) regionally refined over eastern China (14 km) in reproducing the seasonal evolution of EASM precipitation over China. Compared with reference datasets, VR‐CESM shows better performance than the corresponding globally uniform coarse‐resolution model CESM (quasi‐uniform 1°), especially over western China where complex local topography exists. The northward monsoon migration is closely related to low‐level southerly flows and vertical moisture advection, which are more reasonably simulated in VR‐CESM. The four critical timings of the EASM (monsoon onset, withdrawal, peak, and duration) are also better captured in VR‐CESM than in CESM. The corresponding spatial Pearson correlation coefficients of the four critical timings with respect to reference datasets are about 0.1 higher in VR‐CESM than those in CESM. Both models are most accurate in simulating monsoon onset and least accurate at simulating the monsoon peak. The overestimated zonal thermal contrast in CESM is responsible for the earlier monsoon onset and excessive precipitation in September over the Yangtze River valley. Finer resolution in VR‐CESM, especially over the Tibetan Plateau (TP), appears to be a main factor in simulating better zonal thermal contrast and seasonal evolution of the EASM.

54 ENVIRONMENTAL SCIENCES↗

A fast and sensitive size-exclusion chromatography method for plasma extracellular vesicle proteomic analysis

Extracellular vesicles (EVs) carry diverse biomolecules derived from their parental cells, making their components excellent biomarker candidates. However, purifying EVs is a major hurdle in biomarker discovery since current methods require large amounts of samples, are time-consuming and typically have poor reproducibility. Here we describe a simple, fast, and sensitive EV fractionation method using size exclusion chromatography (SEC) on a fast protein liquid chromatography (FPLC) system. Our method uses a Superose 6 Increase 5/150, which has a bed volume of 2.9 mL. The FPLC system and small column size enable reproducible separation of only 50 µL of human plasma in 15 min. To demonstrate the utility of our method, we used longitudinal samples from a group of individuals who underwent intense exercise. A total of 838 proteins were identified, of which, 261 were previously characterized as EV proteins, including classical markers, such as cluster of differentiation (CD)9 and CD81. Quantitative analysis showed low technical variability with correlation coefficients greater than 0.9 between replicates. The analysis captured differences in relevant EV proteins involved in response to physical activity. Our method enables fast and sensitive fractionation of plasma EVs with low variability, which will facilitate biomarker studies in large clinical cohorts.

59 BASIC BIOLOGICAL SCIENCES↗

Combining pairwise structural similarity and deep learning interface contact prediction to estimate protein complex model accuracy in CASP15

Abstract Estimating the accuracy of quaternary structural models of protein complexes and assemblies (EMA) is important for predicting quaternary structures and applying them to studying protein function and interaction. The pairwise similarity between structural models is proven useful for estimating the quality of protein tertiary structural models, but it has been rarely applied to predicting the quality of quaternary structural models. Moreover, the pairwise similarity approach often fails when many structural models are of low quality and similar to each other. To address the gap, we developed a hybrid method (MULTICOM_qa) combining a pairwise similarity score (PSS) and an interface contact probability score (ICPS) based on the deep learning inter‐chain contact prediction for estimating protein complex model accuracy. It blindly participated in the 15th Critical Assessment of Techniques for Protein Structure Prediction (CASP15) in 2022 and performed very well in estimating the global structure accuracy of assembly models. The average per‐target correlation coefficient between the model quality scores predicted by MULTICOM_qa and the true quality scores of the models of CASP15 assembly targets is 0.66. The average per‐target ranking loss in using the predicted quality scores to rank the models is 0.14. It was able to select good models for most targets. Moreover, several key factors (i.e., target difficulty, model sampling difficulty, skewness of model quality, and similarity between good/bad models) for EMA are identified and analyzed. The results demonstrate that combining the multi‐model method (PSS) with the complementary single‐model method (ICPS) is a promising approach to EMA.

59 BASIC BIOLOGICAL SCIENCES↗

A priori analysis on deep learning of subgrid-scale parameterizations for Kraichnan turbulence

In the present study, we investigate different data-driven parameterizations for large eddy simulation of two-dimensional turbulence in the a priori settings. These models utilize resolved flow field variables on the coarser grid to estimate the subgrid-scale stresses. We use data-driven closure models based on localized learning that employs a multilayer feedforward artificial neural network with point-to-point mapping and neighboring stencil data mapping, and convolutional neural network fed by data snapshots of the whole domain. The performance of these data-driven closure models is measured through a probability density function and is compared with the dynamic Smagorinksy model (DSM). The quantitative performance is evaluated using the cross-correlation coefficient between the true and predicted stresses. We analyze different frameworks in terms of the amount of training data, selection of input and output features, their characteristics in modeling with accuracy, and training and deployment computational time. We also demonstrate computational gain that can be achieved using the intelligent eddy viscosity model that learns eddy viscosity computed by the DSM instead of subgrid-scale stresses. Here, we detail the hyperparameters optimization of these models using the grid search algorithm.

42 ENGINEERING↗

Constitutive model development of aluminum alloy 1100 for elevated temperature forming process

Commercially pure aluminum alloy, AA1100, presents good electrical and thermal conductivity, high formability, and low cost. Those favorable characteristics have the potential to enable bipolar plates with improved economics and enhanced performance compared to current stainless steel bipolar plates for proton exchange membrane fuel cells. An accurate constitutive model is essential to develop and optimize processing parameters and effectively control the forming process. Here, the objective of this work is to develop a constitutive model of AA1100 that is able to simulate stress-strain relation, formed geometry, and predict the onset of fracture strain to avoid forming failure. Initially, a set of tensile tests at temperature between 300 and 500°C and strain rate between 0.005 and 1.0/s were conducted to examine the deformation behavior. Then, a set of damage-based unified visco-plastic constitutive equations is proposed and calibrated based on the results of stress-strain data. A genetic algorithm optimization method is applied to search for best fitting material constants in constitutive equations. The proposed model shows good predictability of both the stress-strain relation and fracture strain at low strain rate and high temperature conditions. The accuracy of proposed model is also evaluated statistically. A comparison of the proposed model with three popular models (Arrhenius-type mode, Johnson-Cook model and Zerilli-Armstrong model) was made. The proposed model shows the best experimental agreement with correlation coefficient of 0.96 in contrast to 0.25, 0.38 and 0.75 for the popular models, respectively. The proposed model can help to optimize the elevated temperature forming process and guide die design to enable optimal geometric features in the formed components.

08 HYDROGEN↗

Reader agreement and accuracy of ultrasound features for hepatic steatosis

Purpose: The purpose of the study is to assess the reader agreement and accuracy of eight ultrasound imaging features for classifying hepatic steatosis in adults with known or suspected hepatic steatosis. Methods: This was an IRB-approved, HIPAA-compliant prospective study of adult patients with known or suspected hepatic steatosis. All patients signed written informed consent. Ultrasound images (Siemens S3000, 6C1HD, and 4C1 transducers) were acquired by experienced sonographers following a standard protocol. Eight readers independently graded eight features and their overall impression of hepatic steatosis on ordinal scales using an electronic case report form. Duplicated images from the 6C1HD transducer were read twice to assess intra-reader agreement. Intra-reader, inter-transducer, and inter-reader agreement were assessed using intraclass correlation coefficients (ICC). Features with the highest intra-reader agreement were selected as predictors for dichotomized histological steatosis using Classification and Regression Tree (CART) analysis, and the accuracy of the decision rule was compared to the accuracy of the radiologists’ overall impression. Results: 45 patients (18 males, 27 females; mean age 56 ± 12 years) scanned from September 2015 to July 2016 were included. Mean intra-reader ICCs ranged from 0.430 to 0.777, inter-transducer ICCs ranged from 0.228 to 0.640, and inter-reader ICCs ranged from 0.014 to 0.561. The CART decision rule selected only large hepatic vein blurring and achieved similar accuracy to the overall impression (74% to 75% and 68% to 72%, respectively). Conclusions: Large hepatic vein blurring, liver–kidney contrast, and overall impression provided the highest reader agreement. Large hepatic vein blurring may provide the highest classification accuracy for dichotomized grading of hepatic steatosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inter-reader agreement of magnetic resonance imaging proton density fat fraction and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis

Purpose: To determine the inter-reader agreement of magnetic resonance imaging proton density fat fraction (PDFF) and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis (NASH). Study type: We performed a secondary analysis of a placebo-controlled randomized clinical trial of a bile acid sequestrant in 45 adults with NASH. A six-echo spoiled gradient-recalled-echo magnitude-based fat quantification technique was performed at 3 T. Three independent readers measured MRI-PDFF by placing one primary and two additional regions of interest (ROIs) in each segment at both time points. Cross-sectional agreement between the three readers was evaluated using intra-class correlation coefficients (ICCs) and coefficients of variation (CV). Additionally, we used Bland–Altman analyses to examine pairwise agreement between the three readers at baseline, end of treatment (EOT), and for longitudinal change. Results: Using all ROIs by all readers, mean PDFF at baseline, at EOT, and mean change in PDFF was 16.1%, 16.0%, and 0.07%, respectively. The 27-ROI PDFF measurements had 0.998 ICC and 1.8% CV at baseline, 0.998 ICC and 1.8% CV at EOT, and 0.997 ICC for longitudinal change. The 9-ROI PDFF measurements had corresponding values of 0.997 and 2.6%, 0.996 and 2.4%, and 0.994. Using 27 ROIs, the magnitude of the bias between readers for whole-liver PDFF measurement ranged from 0.03% to 0.06% points at baseline, 0.01% to 0.07% points at EOT, and 0.01% to 0.02% points for longitudinal change. Conclusion: Inter-reader agreement for measuring whole-liver PDFF and its longitudinal change is high. 9-ROI measurements have only slightly lower agreement than 27-ROI measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The anatomy of the renal pyelocaliceal system studied by CTU

Introduction and objectives: Knowledge of the pyelocaliceal system anatomy is essential for the safe and successful performance of endourologic procedures. The purpose of this study was to provide a better understanding of the full three-dimensional pyelocaliceal system anatomy. Methods: Morphometric parameters of the three-dimensional reconstructions of computed tomography intravenous urography scans (n = 25 scans) were analyzed. Both kidneys were divided into three equal-sized segments (US: upper segment, MS: mid segment, LS: lower segment). Infundibular length (IL), infundibular width (IW), the number of calyces, and the transverse orientation in hours of a clock of each calyx as well as the dimension of the pyelum were determined. Results: The mean upper IL (n = 92) was longer than the middle (n = 154) and lower IL (n = 112) (30.6 ± 7.9 mm vs. 16.4 ± 7.7 mm vs. 16.0 ± 6.0 mm, respectively; P = < 0.0001). IW was significantly smaller in the MS [3.7 ± 1.9 mm], followed by the US [4.6 ± 1.9 mm], and the LS [4.9 ± 2.2] in the increasing order. No correlation was found between IL and IW (Pearson correlation coefficient = 0.1). The US calyces were predominantly orientated lateral (8-10 o’clock: 44.5%) and medial (2–4 o’clock: 30.5%), in the MS lateral (8–10 o’clock: 87.6%) and anterolateral in the LS (9–12 o’clock: 67.9%). 74% of the kidneys consisted of 6–8 calyces (mean 7.2 ± 1.4, range 4–10), with the majority of the calyces in the MS (3.1 ± 0.8) followed by the LS (2.24 ± 0.8), and US (1.8 ± 0.7). There were no statistical differences between the right and left kidneys in terms of IL (P = 0.112) and number of calyces (P = 0.685). Conclusion: Anatomic differences between the three segments of the pyelocaliceal system in terms of IL, IW, calyces number, and orientation are seen and should be considered when performing an endourologic procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Opportunistic bone density screening for the abdominal radiologist using colored CT images: a pilot retrospective study

Purpose: The purpose of the study was to develop an accurate and reproducible method for detecting low spinal bone density on abdominal CT images. Methods: For this IRB-approved HIPAA-compliant single-center retrospective study, nonenhanced CT images of the lower abdomen were obtained in 631 African-American participants. Mean attenuation of L3/L4 was associated with quantitative CT bone density (QCT) in a randomly selected training cohort (N = 511), and receiver operating characteristics analysis was used to identify the optimal mean attenuation threshold for differentiating normal from low bone density. Custom image processing software was used to generate grayscale and colored CT images of the midline spine, with green for normal and red for low bone density. Five radiologists independently assessed bone density at L3/L4 in a validation cohort (N = 120) using various methods: QCT, visual assessment of sagittal grayscale images (Grayscale), quantitative measurement of mean attenuation on a midline sagittal image (Attenuation), and visual assessment of a midline sagittal colored image (Color). Accuracy was calculated using the average QCT bone density as a reference standard. Inter-observer agreement was assessed using intraclass correlation coefficient (ICC). Results: The optimal mean attenuation threshold for differentiating normal from low bone density at L3/L4 was 145 Hounsfield Units. The average accuracy of Grayscale, Attenuation, and Color methods was 58, 87, and 91% (p < 0.001), respectively. Inter-observer agreement was poor for Grayscale (ICC: 0.20; 95% CI 0.12, 0.28) and excellent for both Attenuation (ICC: 0.85; 95% CI 0.73, 0.91) and Color methods (ICC: 0.87; 95% CI 0.83, 0.90). Conclusion: Detection of low spinal bone density using colored abdominal CT images was highly accurate and reproducible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The role of contrast-enhanced computed tomography to detect renal stones

Purpose: To investigate the detectability of renal stones in corticomedullary and nephrographic phases on contrast-enhanced computed tomography (CT). Methods: All consecutive patients between January 2012 and February 2016 undergoing CT of the kidneys according to our department’s standard four-phase protocol and having at least one stone in the NC-phase (NCP) were included. Fifty patients with altogether 136 stones were eligible. Two radiologists in consensus evaluated the NCP from each examination and documented the number, location, and size of stones. Three abdominal radiologists blinded to the findings of the NCP reviewed independently the corticomedullary and nephrographic phases on two different occasions. They reported the number and location of stones in each kidney. For the inter-observer agreement the intra-class correlation coefficient (ICC) was estimated. The detection rate of renal stones was calculated for the three radiologists and compared between the two contrast-enhanced phases and the results were analyzed with concern to the size of the stones. Results: The ICC was 0.86. There was no statistically significant difference between corticomedullary and nephrographic phases (p = 0.94). The detection rate for stones measuring 3–5 mm was 82–88% and 98% for stones ≥ 6 mm. Conclusion: The detectability of renal stones ≥ 6 mm on contrast-enhanced CT is extremely high. This means that stones with a higher risk of not passing spontaneously can be safely diagnosed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Juxtatumoral perinephric fat analysis in clear cell renal cell carcinoma

Purpose: The purpose of the study was to evaluate the feasibility of using contrast-enhanced computed tomography (CECT)-based texture analysis (CTTA) metrics to differentiate between juxtatumoral perinephric fat (JPF) surrounding low-grade (ISUP 1–2) versus high-grade (ISUP 3–4) clear cell renal cell carcinoma (ccRCC). Methods: In this IRB-approved study, we retrospectively queried the surgical database between June 2009 and April 2016 and identified 83 patients with pathologically confirmed ccRCC (low grade: n = 54, mean age = 61.5 years, 18F/35M; high grade n = 30, mean age = 61.7 years, 8F/22M) who also had pre-operative multiphase CT acquisitions. CT images were transferred to a 3D workstation, and nephrographic phase JPF regions were manually segmented. Using an in-house developed Matlab program, a CTTA panel comprising of texture metrics extracted using six different methods, histogram, 2D- and 3D-Gray-level co-occurrence matrix (GLCM) and Gray-level difference matrix (GLDM), and 2D-Fast Fourier Transform (FFT) analyses, was applied to the segmented images to assess JPF textural heterogeneity in low- versus high-grade ccRCC. Univariate analysis and receiver-operator characteristics (ROC) analysis were used to assess interclass differences in texture metrics and their prediction accuracy, respectively. Results: All methods except GLCM consistently revealed increased heterogeneity in the JPF surrounding high- versus low-grade ccRCC. FFT showed increased complexity index (p < 0.01). Histogram analysis showed increased kurtosis and positive skewness in (p < 0.03), and GLDM analysis showed decreased measure of correlation coefficient (MCC) (p < 0.04). Several of the GLCM metrics showed statistically significant (p < 0.04) textural differences between the two groups, but with no consistent trend. ROC analysis showed that MCC in GLCM analysis had an area under the curve of 0.75. Conclusions: Our study suggests that CTTA of ccRCC shows statistically significant textural differences in JPF surrounding high- versus low-grade ccRCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiographic stool quantification: an equivalence study of 484 symptomatic and asymptomatic subjects

Purpose: To determine if symptomatic patients referred for radiographic stool quantification have equivalent stool burden to asymptomatic patients. Method: This was an IRB-approved HIPAA-compliant retrospective equivalence cohort study. An a priori equivalence power calculation was performed. Consecutive abdominal radiographs performed in adult outpatients with bloating, constipation, diarrhea, or abdominal pain to assess “fecal loading” [n = 242 (fecal cohort)] were compared to those performed in asymptomatic adult outpatients to assess “renal stones” [n = 242 (renal cohort)]. Radiographs were randomized and reviewed by two blinded independent abdominal radiologists. Exclusion criteria, designed to avoid unblinding, included urinary tract calculi ≥ 0.5 cm, multiple urinary tract calculi, and ureteral stent(s). Readers scored all radiographs (n = 484) for stool burden using validated Leech criteria [scale: 0 (none) to 15 (extreme diffuse)]. Mean Leech scores and 95% confidence intervals were calculated. Multivariable generalized linear modeling was performed to adjust for baseline medication use, age, and gender. The adjusted parameter estimate was used to test for equivalence in the mean difference between cohorts using Schuirmann’s method of two one-sided t-tests. Inter-reader agreement was assessed with intraclass correlation coefficients. Results: Overall mean Leech scores for fecal [6.9 (95% CI 6.7, 7.2)] and renal [7.3 (95% CI 7.1, 7.5)] cohorts were equivalent within a margin of 0.75 (adjusted mean difference: − 0.4 [90% CI − 0.7, − 0.04]; p value = 0.02). Inter-reader agreement was good [ICC: 0.62 (95% CI 0.56, 0.68)]. Conclusion: Radiographic stool quantification produces equivalent results in symptomatic and asymptomatic adults and is of uncertain value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of fat and skeletal muscle tissue at abdominal computed tomography: associations between single-slice measurements and total compartment volumes

Purpose: Body composition is of great prognostic value in several severe diseases, including different types of cancer as well as cardiometabolic disorders. We aimed to investigate the correlations of skeletal muscle mass and abdominal adipose tissue compartments between volumetric and single-slice measurements to study the usefulness of several anatomical landmarks for estimation of total compartment volumes using abdominal CT-scans. Methods: In this retrospective study volumetric quantifications of paraspinal skeletal muscles (SM) and adipose tissue compartments (visceral adipose tissue, VAT; subcutaneous adipose tissue, SAT) were performed in 50 consecutive patients (26 male; mean age, 63 ± 15 years) who underwent abdominal multislice-CT for diagnostic purposes using an in-house software. Associations between total volumes of SM, VAT, and SAT with single-slice measurements at eight predefined anatomical landmarks (median intervertebral disk spaces T12/L1 to L5/S1; level of the umbilicus (U); level of the radix of the superior mesenteric artery (SMA)) were studied using correlation coefficients. Results: Statistical analysis revealed a strong association between single-slice measurements of adipose tissue compartments with total VAT and SAT volume (VAT: all r > 0.89, P < 0.001; SAT: all r > 0.95, P < 0.001). The strongest associations with total SM volume were found for single-slice measurements obtained at L3/4 (r = 0.94, P < 0.001) and were further improved by normalization to height (r = 0.98, P < 0.001). Conclusions: Single-slice measurements of SM, VAT, and SAT at several anatomical landmarks are strongly associated with total compartment volumes and therefore allow for easy and simultaneous assessment of skeletal muscle mass and adipose tissue compartment volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic imaging of hepatocellular carcinoma at community hospitals and their tertiary referral center in the era of LI-RADS: a quality assessment study

Purpose: To assess guideline compliance and quality of hepatocellular carcinoma, (HCC) diagnostic imaging within community hospitals (CH) and their Tertiary referral center (TRC) in a moderately high incidence region. Methods: Initial diagnostic workup CT/MRI scans of 251 patients (122 CH, 112 TRC, 17 Non-TRC academic) with HCC over a 15-month period were assessed for Liver reporting and Data System (LI-RADS) guideline compliance. 269 scans (182 CT, 87 MRI) were qualitatively evaluated by 2 independent blinded radiologists for arterial timing, overall image quality, noise and sharpness, with quantification of interobserver variability. The contrast enhancement ratio (CER) for the largest HCC on each scan was calculated using pre- and post-contrast images. Results: 103/104 (99%) of TRC and 44/78 (56%) of CH CTs adhered to LI–RADS imaging guidelines (P < 0.0001). Lack of delayed phase accounted for 32/34 (94%) of noncompliant CH CTs. Regarding MRI, 19/19 (100%) of TRC and 60/68 (88%) of CH scans were adherent (P = 0.12). For both modalities, overall image quality, noise and sharpness were rated significantly higher for TRC than CH. There was moderate interobserver agreement with intraclass correlation coefficient of 0.73, 0.70 and 0.63, respectively. Arterial-phase timing was rated adequate for CT in 75/104 TRC (72%) and 10/68 (14%) CH scans (P < 0.0001) and for MRI in 8/19 (42%) TRC and 23/68 (33%) CH scans (P = 0.17). The CER was significantly higher for TRC versus CH (2.9 vs. 1.9, P < 0.001) and MRI (0.9 vs. 0.7, P = 0.03). Conclusions: Community hospital HCC diagnostic scans significantly lag in critical quality parameters of tumor enhancement, arterial phase timing, perceived image quality, and LI-RADS CT technique compliance compared to a TRC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reproducibility of Abdominal Aortic Aneurysm Diameter Measurement and Growth Evaluation on Axial and Multiplanar Computed Tomography Reformations

Purpose: To compare different methods measuring abdominal aortic aneurysm (AAA) maximal diameter (Dmax) and its progression on multidetector computed tomography (MDCT) scan. Materials and Methods: Forty AAA patients with two MDCT scans acquired at different times (baseline and follow-up) were included. Three observers measured AAA diameters by seven different methods: on axial images (anteroposterior, transverse, maximal, and short-axis views) and on multiplanar reformation (MPR) images (coronal, sagittal, and orthogonal views). Diameter measurement and progression were compared over time for the seven methods. Reproducibility of measurement methods was assessed by intraclass correlation coefficient (ICC) and Bland-Altman analysis. Results: Dmax, as measured on axial slices at baseline and follow-up (FU) MDCTs, was greater than that measured using the orthogonal method (p = 0.046 for baseline and 0.028 for FU), whereas Dmax measured with the orthogonal method was greater those using all other measurement methods (p-value range: <0.0001-0.03) but anteroposterior diameter (p = 0.18 baseline and 0.10 FU). The greatest interobserver ICCs were obtained for the orthogonal and transverse methods (0.972) at baseline and for the orthogonal and sagittal MPR images at FU (0.973 and 0.977). Interobserver ICC of the orthogonal method to document AAA progression was greater (ICC = 0.833) than measurements taken on axial images (ICC = 0.662-0.780) and single-plane MPR images (0.772-0.817). Conclusion: AAA Dmax measured on MDCT axial slices overestimates aneurysm size. Diameter as measured by the orthogonal method is more reproducible, especially to document AAA progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of the Virtual Liver Parenchymal Perfusion Area Using a Commercially Available Workstation in Transarterial Chemoembolization for Hepatocellular Carcinoma

Purpose: To evaluate the accuracy of the virtual liver parenchymal perfusion area using a commercially available workstation and liver analysis software in conventional transarterial chemoembolization (cTACE) for hepatocellular carcinoma (HCC). Materials and Methods: This method was retrospectively applied to 29 treated HCCs in 23 patients. The virtual embolic area (VEA) was estimated based on cone beam computed tomography during hepatic arteriography using a commercially available workstation and liver analysis software by two observer groups (group A: experts; group B: semi-experts). The real embolic area (REA) was defined as the area where iodized oil accumulated on computed tomography at 1 week after cTACE. The REA was estimated by each of the two groups, and the mean REA between the groups (mREA) was used as a standard reference. Agreement of volume and cross-sectional area in three orthogonal planes between the VEA and mREA were analyzed using intraclass correlation coefficients (ICCs) and Bland–Altman plots. Results: The ICCs for volume between VEA and mREA were 0.97 and 0.88 for groups A and B, respectively, and those for cross-sectional area were 0.94 and 0.88 for the axial plane, 0.95 and 0.83 for the coronal plane, and 0.87 and 0.74 for the sagittal plane, respectively. Thus, the overall agreement was excellent, except for the sagittal imaging plane in group B. Conclusion: This method using a commercially available workstation and liver analysis software can be useful for estimating the embolic area in cTACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗