Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlative imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

A back-illuminated megapixel CMOS image sensor

In this paper, we present the test and characterization results for a back-illuminated megapixel CMOS imager. The imager pixel consists of a standard junction photodiode coupled to a three transistor-per-pixel switched source-follower readout [1]. The imager also consists of integrated timing and control and bias generation circuits, and provides analog output. The analog column-scan circuits were implemented in such a way that the imager could be configured to run in off-chip correlated double-sampling (CDS) mode. The imager was originally designed for normal front-illuminated operation, and was fabricated in a commercially available 0.5 pn triple-metal CMOS-imager compatible process. For backside illumination, the imager was thinned by etching away the substrate was etched away in a post-fabrication processing step.

Complementary Metal Oxide Semiconductor imager (CM↗

Analysis of Anechoic Chamber Testing of the Hurricane Imaging Radiometer

The Hurricane Imaging Radiometer System (HIRAD) is a new airborne passive microwave remote sensor developed to observe hurricanes. HIRAD incorporates synthetic thinned array radiometry technology, which use Fourier synthesis to reconstruct images from an array of correlated antenna elements. The HIRAD system response to a point emitter has been measured in an anechoic chamber. With this data, a Fourier inversion image reconstruction algorithm has been developed. Performance analysis of the apparatus is presented, along with an overview of the image reconstruction algorithm

Fenigstein, David↗

Optical stereo video signal processor

An otpical video signal processor is described which produces a two-dimensional cross-correlation in real time of images received by a stereo camera system. The optical image of each camera is projected on respective liquid crystal light valves. The images on the liquid crystal valves modulate light produced by an extended light source. This modulated light output becomes the two-dimensional cross-correlation when focused onto a video detector and is a function of the range of a target with respect to the stereo camera. Alternate embodiments utilize the two-dimensional cross-correlation to determine target movement and target identification.

Craig, G. D.↗

Electronic Still Camera

A handheld, programmable, digital camera is disclosed that supports a variety of sensors and has program control over the system components to provide versatility. The camera uses a high performance design which produces near film quality images from an electronic system. The optical system of the camera incorporates a conventional camera body that was slightly modified, thus permitting the use of conventional camera accessories, such as telephoto lenses, wide-angle lenses, auto-focusing circuitry, auto-exposure circuitry, flash units, and the like. An image sensor, such as a charge coupled device ('CCD') collects the photons that pass through the camera aperture when the shutter is opened, and produces an analog electrical signal indicative of the image. The analog image signal is read out of the CCD and is processed by preamplifier circuitry, a correlated double sampler, and a sample and hold circuit before it is converted to a digital signal. The analog-to-digital converter has an accuracy of eight bits to insure accuracy during the conversion. Two types of data ports are included for two different data transfer needs. One data port comprises a general purpose industrial standard port and the other a high speed/high performance application specific port. The system uses removable hard disks as its permanent storage media. The hard disk receives the digital image signal from the memory buffer and correlates the image signal with other sensed parameters, such as longitudinal or other information. When the storage capacity of the hard disk has been filled, the disk can be replaced with a new disk.

Holland, S. Douglas↗

Proceedings of the Third Annual Symposium on Mathematical Pattern Recognition and Image Analysis

Topics addressed include: multivariate spline method; normal mixture analysis applied to remote sensing; image data analysis; classifications in spatially correlated environments; probability density functions; graphical nonparametric methods; subpixel registration analysis; hypothesis integration in image understanding systems; rectification of satellite scanner imagery; spatial variation in remotely sensed images; smooth multidimensional interpolation; and optimal frequency domain textural edge detection filters.

Guseman, L. F., Jr.↗

Improving Sparse-Aperture Interferometric Radiometry

Proposed method for designing spatial arrangement of antennas of sparse-aperture interferometric radiometry (SAIR) system increases spatial resolution of images produced by system. Technique involves cross-correlation of signals received by pairs of small antennas at different locations. Includes ring array of "flood-beam" antennas. Signals from all possible pairs of antennas cross-correlated simultaneously. Diameter of ring determines spatial resolution of image, and distribution of antennas around ring determines sampling characteristics. Conceived to improve proposed remote-sensing SAIR system placed in geosynchronous orbit; also applied to other SAIR systems intended to stare at stationary targets for relatively long times.

Ruf, Christopher S.↗

The VISAR Process

The Video Image Stabilization And Registration (VISAR) process is an award winning video image processing software developed at NASA's Marshall Space Flight Center. VISAR has a wide variety of application areas where the refinement of digital video is needed. It is used to correct jitter, rotation, and zoom effects by registering and processing on individual image captures that are a part of normal video capturing. Its most prominent uses were the 1996 Olympic Bombing case and in identifying Saddam Hussein during the Iraq war. Based on first-hand knowledge, this paper describes the VISAR process, which consists of several steps designed to refine digital video using VISAR software. The process determines the differences between two video images so that one, or both, of the images can be changed in ways that make them match as well as possible. Corrections include changes in position (horizontal and vertical image shifts), changes in orientation (image rotation), and changes in magnification (image zoom). While much of the VISAR process is automated, in its current embodiment it requires the user to initially identify the area of interest and to reset a threshold parameter if the default gives unacceptable results. The basic process that is used is an old tried and true method that determines how well the two images match. This process is called cross-correlation. It gives a single number, the correlation coefficient, that is equal to 1.0 if the images are perfectly matched, is equal to 0.0 if the images have nothing in common, and is equal to -1.0 if one image is the negative of the other. This basic process is used by many image stabilization methods. With VISAR we use it in a manner that provides statistical information needed to best determine orientation and magnification.

Hathaway, David↗

Performance of the image statistics decoder in conjunction with the Goldstone-VLA array

During Voyager's Neptune encounter, the National Radio Astronomy Observatory's Very Large Array (VLA) will be arrayed with Goldstone antennas to receive the transmitted telemetry data from the spacecraft. The telemetry signal from the VLA will drop out periodically, resulting in a periodic drop in the received signal-to-noise ratio (SNR). The Image Statistics Decoder (ISD), which assumes a correlation between pixels, can improve the bit error rate (BER) for images during these dropout periods. Simulation results have shown that the ISD, in conjunction with the Goldstone-VLA array can provide a 3-dB gain for uncompressed images at a BER of 5.0 x 10(exp -3).

Wang, H. C.↗

Recent volcanic activity on Venus - Evidence from radiothermal emissivity measurements

Radiothermal emissivity measurements are analyzed in order to study large volcanic constructs on Venus and to correlate details of the reflectivity/emissivity patterns with geological landforms and stratigraphy visible in corresponding SAR images. There appears to be a correlation between locations on Venus where high emissivity at high altitudes and low emissivity at low altitudes are observed. These phenomena are attributed here to relatively recent volcanic activity: the former to summit eruptions that have not had time to weather to the low-emissivity state, the latter to continuing emission of volcanic gases from neighboring small plains volcanoes. The pattern of reflectivity and emissivity on Maat Mons is examined in the light of these findings. It is concluded that Maat Mons has undergone the most recent episode of volcanic activity of all the volcanoes studied here.

Robinson, Cordula A.↗

L-band radar sensing of soil moisture

The objectives of the experiment were to assess the performance of an L-band, 25-cm wavelength imaging synthetic aperture radar (SAR) for soil moisture determination, and to study the temporal variability of radar returns from a number of agricultural fields. A series of overflights was accomplished during March 1977 over an agricultural test site in Kern County, Calif. Soil moisture samples were collected from bare fields at nine sites at depths of 0-2, 2-5, 5-15, and 15-30 cm. These gravimetric measurements were converted to percent of field capacity for correlation to the radar return signal. The initial signal film was optically correlated and scanned to produce image data numbers. These numbers were then converted to relative return power by linear interpolation of the noise power wedge which was introduced in 5-dB steps into the original signal film before and after each data run. Results of correlations between the relative return power and percent of field capacity demonstrate that the relative return power from this imaging radar system is responsive to the amount of soil moisture in bare fields. The signal returned from dry and wet fields where furrowing is parallel to the radar beam differs by about 15 dB. Before this technique can be operationally employed, adequate calibration of the radar system is required to insure comparability of data both from area to area within a single flight and between different flights.

Chang, A. T. C.↗

Motion detection in astronomical and ice floe images

Two approaches are presented for establishing correspondence between small areas in pairs of successive images for motion detection. The first one, based on local correlation, is used on a pair of successive Voyager images of the Jupiter which differ mainly in locally variable translations. This algorithm is implemented on a sequential machine (VAX 780) as well as the Massively Parallel Processor (MPP). In the case of the sequential algorithm, the pixel correspondence or match is computed on a sparse grid of points using nonoverlapping windows (typically 11 x 11) by local correlations over a predetermined search area. The displacement of the corresponding pixels in the two images is called the disparities to cubic surfaces. The disparities at points where the error between the computed values and the surface values exceeds a particular threshold are replaced by the surface values. A bilinear interpolation is then used to estimate disparities at all other pixels between the grid points. When this algorithm was applied at the red spot in the Jupiter image, the rotating velocity field of the storm was determined. The second method of motion detection is applicable to pairs of images in which corresponding areas can experience considerable translation as well as rotation.

Manohar, M.↗

L-band radar sensing of soil moisture

The performance of an L-band, 25 cm wavelength imaging synthetic aperture radar was assessed for soil moisture determination, and the temporal variability of radar returns from a number of agricultural fields was studied. A series of three overflights was accomplished over an agricultural test site in Kern County, California. Soil moisture samples were collected from bare fields at nine sites at depths of 0-2, 2-5, 5-15, and 15-30 cm. These gravimetric measurements were converted to percent of field capacity for correlation to the radar return signal. The initial signal film was optically correlated and scanned to produce image data numbers. These numbers were then converted to relative return power by linear interpolation of the noise power wedge which was introduced in 5 dB steps into the original signal film before and after each data run. Results of correlations between the relative return power and percent of field capacity (FC) demonstrate that the relative return power from this imaging radar system is responsive to the amount of soil moisture in bare fields. The signal returned from dry (15% FC) and wet (130% FC) fields where furrowing is parallel to the radar beam differs by about 10 dB.

Chang, A. T. C.↗

Computing Challenges in Coded Mask Imaging

This slide presaentation reviews the complications and challenges in developing computer systems for Coded Mask Imaging telescopes. The coded mask technique is used when there is no other way to create the telescope, (i.e., when there are wide fields of view, high energies for focusing or low energies for the Compton/Tracker Techniques and very good angular resolution.) The coded mask telescope is described, and the mask is reviewed. The coded Masks for the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) instruments are shown, and a chart showing the types of position sensitive detectors used for the coded mask telescopes is also reviewed. Slides describe the mechanism of recovering an image from the masked pattern. The correlation with the mask pattern is described. The Matrix approach is reviewed, and other approaches to image reconstruction are described. Included in the presentation is a review of the Energetic X-ray Imaging Survey Telescope (EXIST) / High Energy Telescope (HET), with information about the mission, the operation of the telescope, comparison of the EXIST/HET with the SWIFT/BAT and details of the design of the EXIST/HET.

Skinner, Gerald↗

Algorithm for Compressing Time-Series Data

An algorithm based on Chebyshev polynomials effects lossy compression of time-series data or other one-dimensional data streams (e.g., spectral data) that are arranged in blocks for sequential transmission. The algorithm was developed for use in transmitting data from spacecraft scientific instruments to Earth stations. In spite of its lossy nature, the algorithm preserves the information needed for scientific analysis. The algorithm is computationally simple, yet compresses data streams by factors much greater than two. The algorithm is not restricted to spacecraft or scientific uses: it is applicable to time-series data in general. The algorithm can also be applied to general multidimensional data that have been converted to time-series data, a typical example being image data acquired by raster scanning. However, unlike most prior image-data-compression algorithms, this algorithm neither depends on nor exploits the two-dimensional spatial correlations that are generally present in images. In order to understand the essence of this compression algorithm, it is necessary to understand that the net effect of this algorithm and the associated decompression algorithm is to approximate the original stream of data as a sequence of finite series of Chebyshev polynomials. For the purpose of this algorithm, a block of data or interval of time for which a Chebyshev polynomial series is fitted to the original data is denoted a fitting interval. Chebyshev approximation has two properties that make it particularly effective for compressing serial data streams with minimal loss of scientific information: The errors associated with a Chebyshev approximation are nearly uniformly distributed over the fitting interval (this is known in the art as the "equal error property"); and the maximum deviations of the fitted Chebyshev polynomial from the original data have the smallest possible values (this is known in the art as the "min-max property").

Hawkins, S. Edward, III↗

Achromatical Optical Correlator

Signal-to-noise ratio exceeds that of monochromatic correlator. Achromatical optical correlator uses multiple-pinhole diffraction of dispersed white light to form superposed multiple correlations of input and reference images in output plane. Set of matched spatial filters made by multiple-exposure holographic process, each exposure using suitably-scaled input image and suitable angle of reference beam. Recording-aperture mask translated to appropriate horizontal position for each exposure. Noncoherent illumination suitable for applications involving recognition of color and determination of scale. When fully developed achromatical correlators will be useful for recognition of patterns; for example, in industrial inspection and search for selected features in aerial photographs.

Chao, Tien-Hsin↗

Real-time multiple-look synthetic aperture radar processor for spacecraft applications

A spaceborne synthetic aperture radar (SAR) having pipeline multiple-look data processing is described which makes use of excessive azimuth bandwidth in radar echo signals to produce multiple-looking images. Time multiplexed single-look image lines from an azimuth correlator go through an energy analyzer which analyzes the mean energy in each separate look to determine the radar antenna electric boresight for use in generating the correct reference functions for the production of high quality SAR images. The multiplexed single look image lines also go through a registration delay to produce multi-look images.

Wu, C.↗

Water depth estimation with ERTS-1 imagery

Contrast-enhanced 9.5 inch ERTS-1 images were produced for an investigation on ocean water color. Such images lend themselves to water depth estimation by photographic and electronic density contouring. MSS-4 and -5 images of the Great Bahama Bank were density sliced by both methods. Correlation was found between the MSS-4 image and a hydrographic chart at 1:467,000 scale, in a number of areas corresponding to water depth of less than 2 meters, 5 to 10 meters and 10 to about 20 meters. The MSS-5 image was restricted to depths of about 2 meters. Where reflective bottom and clear water are found, ERTS-1 MSS-4 images can be used with density contouring by electronic or photographic methods for estimating depths to 5 meters within about one meter.

Ross, D. S.↗