Search NASA⌕ Search

SEARCH · Search NASA

Results for “detect and avoid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Gravitational waves from more attractive dark binaries

Abstract The detection of gravitational waves (GWs) has led to a deeper understanding of binaries of ordinary astrophysical objects, including neutron stars and black holes. In this work, we point out that binary systems may also exist in a dark sector with astrophysical-mass macroscopic dark matter. These “dark binaries”, when coupled to an additional attractive long-range dark force, may generate a stochastic gravitational wave background (SGWB) with a characteristic spectrum different from ordinary binaries. We find that the SGWB from planet-mass dark binaries is detectable by space- and ground-based GW observatories. The contribution to the SGWB today is smaller from binaries that merge before recombination than after, avoiding constraints on extra radiation degrees of freedom while potentially leaving a detectable GW signal at high frequencies up to tens of GHz.

Astronomy & Astrophysics↗

Computer vision techniques for rotorcraft low-altitude flight

A description is given of research that applies techniques from computer vision to automation of rotorcraft navigation. The effort emphasizes the development of a methodology for detecting the ranges to obstacles in the region of interest based on the maximum utilization of passive sensors. The range map derived from the obstacle detection approach can be used as obstacle data for the obstacle avoidance in an automataic guidance system and as advisory display to the pilot. The lack of suitable flight imagery data, however, presents a problem in the verification of concepts for obstacle detection. This problem is being addressed by the development of an adequate flight database and by preprocessing of currently available flight imagery. Some comments are made on future work and how research in this area relates to the guidance of other autonomous vehicles.

Sridhar, Banavar↗

A Hybrid FPGA/Tilera Compute Element for Autonomous Hazard Detection and Navigation

To increase safety for future missions landing on other planetary or lunar bodies, the Autonomous Landing and Hazard Avoidance Technology (ALHAT) program is developing an integrated sensor for autonomous surface analysis and hazard determination. The ALHAT Hazard Detection System (HDS) consists of a Flash LIDAR for measuring the topography of the landing site, a gimbal to scan across the terrain, and an Inertial Measurement Unit (IMU), along with terrain analysis algorithms to identify the landing site and the local hazards. An FPGA and Manycore processor system was developed to interface all the devices in the HDS, to provide high-resolution timing to accurately measure system state, and to run the surface analysis algorithms quickly and efficiently. In this paper, we will describe how we integrated COTS components such as an FPGA evaluation board, a TILExpress64, and multi-threaded/multi-core aware software to build the HDS Compute Element (HDSCE). The ALHAT program is also working with the NASA Morpheus Project and has integrated the HDS as a sensor on the Morpheus Lander. This paper will also describe how the HDS is integrated with the Morpheus lander and the results of the initial test flights with the HDS installed. We will also describe future improvements to the HDSCE.

Multicore↗

A hybrid FPGA/Tilera compute element for autonomous hazard detection and navigation

To increase safety for future missions landing on other planetary or lunar bodies, the Autonomous Landing and Hazard Avoidance Technology (ALHAT) program is developing an integrated sensor for autonomous surface analysis and hazard determination. The ALHAT Hazard Detection System (HDS) consists of a Flash LIDAR for measuring the topography of the landing site, a gimbal to scan across the terrain, and an Inertial Measurement Unit (IMU), along with terrain analysis algorithms to identify the landing site and the local hazards. An FPGA and Manycore processor system was developed to interface all the devices in the HDS, to provide high-resolution timing to accurately measure system state, and to run the surface analysis algorithms quickly and efficiently. In this paper, we will describe how we integrated COTS components such as an FPGA evaluation board, a TILExpress64, and multi-threaded/multi-core aware software to build the HDS Compute Element (HDSCE). The ALHAT program is also working with the NASA Morpheus Project and has integrated the HDS as a sensor on the Morpheus Lander. This paper will also describe how the HDS is integrated with the Morpheus lander and the results of the initial test flights with the HDS installed. We will also describe future improvements to the HDSCE.

Trawny, Nikolas↗

Hydrazine Detection with a Tunable Diode Laser Spectrometer

Several instruments have been developed to measure low concentrations of hydrazine but none completely meet the sensitivity requirements while satisfying additional criteria such as quick response, stable calibration, interference free operation, online operation, reasonable cost, etc. A brief review is presented of the current technology including the electrochemical cell, the ion mobility spectrometer, the mass spectrometer, and the gas chromatograph. A review of the advantages and disadvantages of these instruments are presented here. The review also includes commercially unavailable technology such as the electronic nose and the Tunable Diode Laser (TDL) IR Spectrometer. It was found that the TDL could meet the majority of these criteria including fast response, minimum maintenance, portability, and reasonable cost. An experiment was conducted to demonstrate the feasibility of such a system using an existing (non-portable) instrument. A lead-salt tunable diode laser, cooled to 85 degrees Kelvin was used to record direct absorption and second-derivative spectra of Hydrazine at several pressures to study the sensitivity to low levels of Hydrazine. Spectra of NH3 and CO2 were used for wavelength identification of the scanned region. With a pathlength of 80 m, detection sensitivities of about 1 ppb were achieved for hydrazine in dry nitrogen at a cell pressure of 100 mbar. For spectroscopic detection of Hydrazine, spectral regions including strong Ammonia or Carbon Dioxide lines must be avoided. Strong Hydrazine absorption features were identified at 940/cm showing minimal contribution from Ammonia interferences as suitable candidates for Hydrazine gas detection. For the studies reported here, the particular laser diode could only cover the narrow regions near 962/cm and 965/cm where strong Ammonia interferences were expected. However, the high resolution (0.001/cm) of the TDL spectrometer allowed individual lines of Hydrazine to be identified away from interferences from either Ammonia or Carbon Dioxide, especially at lower pressures. A Hydrazine line was identified at 961.75/cm which was free from Ammonia absorption and would be suitable to monitor hydrazine levels. This paper also shows data on the degradation of the detectivity of Hydrazine with increasing pressure. Several design options for a portable unit are presented, including designs with near IR and Quantum Cascade laser components which do not require liquid nitrogen cooling.

Houseman, John↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

Progress in Development of an Airborne Turbulence Detection System

Aircraft encounters with turbulence are the leading cause of in-flight injuries (Tyrvanas 2003) and have occasionally resulted in passenger and crew fatalities. Most of these injuries are caused by sudden and unexpected encounters with severe turbulence in and around convective activity (Kaplan et al 2005). To alleviate this problem, the Turbulence Prediction and Warning Systems (TPAWS) element of NASA s Aviation Safety program has investigated technologies to detect and warn of hazardous in-flight turbulence. This effort has required the numerical modeling of atmospheric convection: 1) for characterizing convectively induced turbulence (CIT) environments, 2) for defining turbulence hazard metrics, and 3) as a means of providing realistic three-dimensional data sets that can be used to test and evaluate turbulence detection sensors. The data sets are being made available to industry and the FAA for certification of future airborne turbulence-detection systems (ATDS) with warning capability. Early in the TPAWS project, a radar-based ATDS was installed and flight tested on NASA s research aircraft, a B-757. This ATDS utilized new algorithms and hazard metrics that were developed for use with existing airborne predictive windshear radars, thus avoiding the installation of new hardware. This system was designed to detect and warn of hazardous CIT even in regions with weak radar reflectivity (i.e. 5-15 dBz). Results from an initial flight test of the ATDS were discussed in Hamilton and Proctor (2002a; 2002b). In companion papers (Proctor et al 2002a; 2002b), a numerical simulation of the most significant encounter from that flight test was presented. Since the presentation of these papers a second flight test has been conducted providing additional cases for examination. In this paper, we will present results from NASA s flight test and a numerical model simulation of a turbulence environment encountered on 30 April 2002. Progress leading towards FAA certification of industry built ATDS will also be discussed.

Hamilton, David W.↗

LAGEOS 3 and the gravitomagnetic field

The importance of the gravitomagnetic field is discussed. A never-measured field of nature, the foundations of inertia in Einstein General Relativity, and a key role in theories of quasars and active galactic nuclei are important aspects of this field and are discussed. In high energy astrophysics, some theories of energy storage, power generation, jet formation and jet alignment of quasars and active galactic nuclei are based on the existence of the gravitomagnetic field of a supermassive black hole (Thorne et al. 1986). LAGEOS 3 is discussed in terms of laser ranged satellites to detect the gravitomagnetic field and supplementary inclination satellites to avoid gravity field uncertainties. Many experiments have been proposed to measure the gravitomagnetic field. The GPB experiment intends to measure the Lense-Thirring-Schiff precession of gyroscopes orbiting the earth. Polar satellites have been proposed to measure the Lense-Thirring precession of the orbital plane (an enormous gyroscope and two guided, drag-free, counter-rotating, polar satellites have been suggested to avoid orbital inclination errors.) The new idea to measure the gravitomagnetic drag of the nodes of two nonpolar, supplementary inclination, satellites is summarized.

Ciufolini, Ignazio↗

Cockpit display of hazardous wind shear information

Information on cockpit display of wind shear information is given in viewgraph form. Based on the current status of windshear sensors and candidate data dissemination systems, the near-term capabilities for windshear avoidance will most likely include: (1) Ground-based detection: TDWR (Terminal Doppler Weather Radar), LLWAS (Low-Level Windshear Alert System), Automated PIREPS; (2) Ground-Air datalinks: Air traffic control voice channels, Mode-S digital datalink, ACARS alphanumeric datalink. The possible datapaths for integration of these systems are illustrated in a diagram. In the future, airborne windshear detection systems such as lidars, passive IR detectors, or airborne Doppler radars may also become available. Possible future datalinks include satellite downlink and specialized en route weather channels.

Wanke, Craig↗

2.5 MHz Line-Width High-energy, 2 Micrometer Coherent Wind Lidar Transmitter

2 micron solid-state lasers are the primary choice for coherent Doppler wind detection. As wind lidars, they are used for wake vortex and clear air turbulence detection providing air transport safety. In addition, 2 micron lasers are one of the candidates for CO2 detection lidars. The rich CO2 absorption line around 2 micron, combined with the long upper state life of time, has made Ho based 2 micron lasers a viable candidate for CO2 sensing DIAL instrument. The design and fabrication of a compact coherent laser radar transmitter for Troposphere wind sensing is under way. This system is hardened for ground as well as airborne applications. As a transmitter for a coherent wind lidar, this laser has stringent spectral line width and beam quality requirements. Although the absolute wavelength does not have to be fixed for wind detection, to maximize return signal, the output wavelength should avoid atmospheric CO2 and H2O absorption lines. The base line laser material is Ho:Tm:LuLF which is an isomorph of Ho:Tm:YLF. LuLF produces 20% more output power than Ho:Tm:YLF. In these materials the Tm absorption cross-section, the Ho emission cross-section, the Tm to Ho energy transfer parameters and the Ho (sup 5) I (sub 7) radiative life time are all identical. However, the improved performance of the LuLF is attributed to the lower thermal population in the (sup 5) I (sub 8) manifold. It also provides higher normal mode to Q-switch conversion than YLF at high pump energy indicating a lower up-conversion. The laser architecture is composed of a seed laser, a ring oscillator, and a double pass amplifier. The seed laser is a single longitudinal mode with a line width of 13 KHz. The 100mJ class oscillator is stretched to 3 meters to accommodate the line-width requirement without compromising the range resolution of the instrument. The amplifier is double passed to produce greater than 300mJ energy.

Petros, Mulugeta↗

Flash LIDAR Emulator for HIL Simulation

NASA's Autonomous Landing and Hazard Avoidance Technology (ALHAT) project is building a system for detecting hazards and automatically landing controlled vehicles safely anywhere on the Moon. The Flash Light Detection And Ranging (LIDAR) sensor is used to create on-the-fly a 3D map of the unknown terrain for hazard detection. As part of the ALHAT project, a hardware-in-the-loop (HIL) simulation testbed was developed to test the data processing, guidance, and navigation algorithms in real-time to prove their feasibility for flight. Replacing the Flash LIDAR camera with an emulator in the testbed provided a cheaper, safer, more feasible way to test the algorithms in a controlled environment. This emulator must have the same hardware interfaces as the LIDAR camera, have the same performance characteristics, and produce images similar in quality to the camera. This presentation describes the issues involved and the techniques used to create a real-time flash LIDAR emulator to support HIL simulation.

Brewster, Paul F.↗

Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer

A multi-channel electrometer voltmeter that employs self-nulling lock-in detection electronics in conjunction with a mechanical resonator with noncontact voltage sensing electrodes has been developed for space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM). The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Use of an AC-coupled lock-in amplifier with closed-loop sense-signal nulling via generation of an active guard-driving feedback voltage provides the resolution, accuracy, linearity and stability needed for long-term space-based measurement of the IESDM. This implementation relies on adjusting the feedback voltage to drive the sense current received from the resonator s variable-capacitance-probe voltage transducer to approximately zero, as limited by the signal-to-noise performance of the loop electronics. The magnitude of the sense current is proportional to the difference between the input voltage being measured and the feedback voltage, which matches the input voltage when the sense current is zero. High signal-to-noise-ratio (SNR) is achieved by synchronous detection of the sense signal using the correlated reference signal derived from the oscillator circuit that drives the mechanical resonator. The magnitude of the feedback voltage, while the loop is in a settled state with essentially zero sense current, is an accurate estimate of the input voltage being measured. This technique has many beneficial attributes including immunity to drift, high linearity, high SNR from synchronous detection of a single-frequency carrier selected to avoid potentially noisy 1/f low-frequency spectrum of the signal-chain electronics, and high accuracy provided through the benefits of a driven shield encasing the capacitance- probe transducer and guarded input triaxial lead-in. Measurements obtained from a 2- channel prototype electrometer have demonstrated good accuracy (|error| < 0.2 V) and high stability. Twenty-four-hour tests have been performed with virtually no drift. Additionally, 5,500 repeated one-second measurements of 100 V input were shown to be approximately normally distributed with a standard deviation of 140 mV.

Blaes, Brent R.↗

Simulations of the Hazard Detection System for Approach Trajectories of the Morpheus Lunar Lander

The Hazard Detection System is part of a suite of sensors and algorithms designed to autonomously land a vehicle on unknown terrain while avoiding any hazards. This paper describes the simulations built to predict the performance of the Hazard Detection System to support flight testing onboard the Morpheus Lander testbed at the Kennedy Space Center. The paper describes a hardware-in-the-loop simulation that was used to predict system performance under nominal operating conditions, and also a Monte Carlo simulation to predict command timing performance bounds under a wide range of varying conditions.

Monte Carlo↗

Reflexive Avoidance Of Obstacles By Robots

Array of sensors at elbow of robotic manipulator detects obstacles. Outputs of sensors processed into synthetic "force field" around each obstacle. Algorithm controlling manipulator uses "force field" to maneuver manipulator arm around each obstacle.

Vold, Havard I.↗

The Role of Marangoni Convection for the FZ-Growth of Silicon

In growing crystals by the floating zone (FZ) technique under microgravity, the size restriction we have under earth conditions because of the hydrostatic pressure are avoided. Further, buoyancy related convection is eliminated to a high degree. But in the case of silicon, the gravity independent thermocapillary (Marangoni) convection is time-dependent even for small zone geometries. This has been demonstrated in several Technische Experimente unter Schwerelosigkeit (TEXUS) - technical experiments under reduced gravity) flights. Thus, to really take advantage of microgravity with respect to improve crystal quality, tools are required to control Marangoni convection in space facilities. Applying magnetic fields, convection can be influenced; fluid flow can either be damped (static magnetic fields) or overlaid by a regular flow regime (rotating magnetic fields). In floating zones of 8-10mm diameter and height (Ma approximately equals 6 x 10(exp 3)), a static magnetic field of about 2OOmT is sufficient to suppress time-dependent Marangoni convection to a high degree, but in dependence on the kind and the concentration of the added dopant, a new type of strongly pronounced dopant inhomogeneities have been detected. They are originated by thermoelectromagnetic convection. This can be avoided as well as detrimental effects on the radial dopant distribution by using rotating magnetic fields instead of static ones. Applying 75mT/50Hz to the FZ, the intensity of the dopant fluctuations is reduced to a high degree. Considering the rather low power consumption of rotating magnetic fields, this will be a useful tool for control or elimination of time-dependent Marangoni convection under microgravity. The strong time dependent character of thermocapillary flow and its influence on the temperature field has been measured in silicon half-zones for Marangoni numbers of Ma is approximately equal to 1-1.5 x 10(exp 4): temperature fluctuations up to 4C have been determined. Their frequency range was 0.1 and 0.4 Hz. Between certain thermocouple or sensor pairs, strong correlation has been detected.

Dold, P.↗

ObstacleSense: Low-Power Neuromorphic Vision for Corridor Obstacle Awareness in Low-Level ADAS

The automotive industry’s pursuit of Level 5 autonomy is constrained by substantial perception-compute power requirements, often reaching 1, 000 + watts in full autonomy stacks. Reducing this energy burden requires rethinking perception not only at the high-end autonomy level, but also at the foundational Advanced Driver Assistance Systems (ADAS) level where low-power, safety-critical sensing can have broad impact. Neuromorphic vision provides a promising starting point: HD Dynamic Vision Sensors (DVS) can operate below 100 mW at the sensor level by reporting only asynchronous brightness changes. However, low-power sensing alone is insufficient if downstream perception reintroduces dense, energy-intensive computation. In particular, many event-driven object-detection pipelines still rely on CNN backbones, while purely spiking alternatives often trade away accuracy or ignore deployment constraints. We introduce ObstacleSense, a highly compact, CNN-free hybrid ANN–SNN framework for Level 0–1 forward-corridor obstacle awareness. Instead of performing full-scene object detection with a convolutional feature backbone, ObstacleSense targets the safety-critical question of whether the ego corridor is occupied and how far the nearest obstacle is. The architecture combines polarity-conditioned event encoding, lightweight temporal spiking dynamics, axial spatial mixing, and coarse-to-fine range estimation within a regular fixed-grid compute pattern. This design avoids the dense CNN backbone commonly used in event-based detection while maintaining a small state footprint suitable for eventual small-FPGA deployment. Before hardware mapping, we evaluate the software implementation using a model-side power proxy derived from MACs, weight and activation traffic, and spiking state updates under shared FP16 assumptions. On simulated CARLA event corpora, the deployment-oriented model achieves 0.9464 objectness F1, 0.9978 grid-level mAP, and 0.8987 m distance Mean Absolute Error at an estimated 1.92 mW proxy cost, while maintaining performance on unseen generalization test sequences.

Johnson-Scott, Zac [ORNL]↗

The Role of Marangoni Convection for the FZ-Growth of Silicon

Growing crystals by the floating zone (FZ) technique under microgravity avoids the size restriction we have under earth conditions due to hydrostatic pressure. Further, buoyancy related convection is eliminated to a great degree. But in the case of silicon, the gravity independent thermocapillary (Marangoni) convection is time-dependent even for small zone geometries. This has been demonstrated in several Technische Experimente unter Schwerelosigkeit (TEXUS) technical experiments under reduced gravity flights. Thus, to really take advantage of microgravity with respect to improved crystal quality, tools are required to control Marangoni convection in space facilities. With the application of magnetic fields, convection can be influenced; fluid flow can either be damped (static magnetic fields) or overlaid by a regular flow regime (rotating magnetic fields). In floating zones of 8-10 mm diameter and height (i.e., Ma is much greater than 6X 10(exp 3), a static magnetic field of about 2OOmT is sufficient to suppress time-dependent Marangoni convection to a high degree, but in dependence on the kind and the concentration of the added dopant, a new type of strongly pronounced dopant inhomogeneities have been detected. They are originated by thermoelectromagnetic convection. This can be avoided as well as detrimental effects on the radial dopant distribution by using rotating magnetic fields instead of static ones. Applying 7.5mT/5OHz to the FZ, the intensity of the dopant fluctuations is reduced to a high degree. Considering the rather low power consumption of rotating magnetic fields, this will be a useful tool for control or elimination of time-dependent Marangoni convection under microgravity. The strong time-dependent character of thermocapillary flow and its influence on the temperature field has been measured in silicon half-zones for Marangoni numbers of Ma is much greater than l - 1.5 X 10(exp 4): temperature fluctuations up to 4C have been determined, their frequency range was 0.4 and 0.4Hz. Between certain thermocouple or sensor pairs, strong correlation has been detected.

Dold, P.↗

Using 2.5D super-resolution to improve flaw detection in metal additive manufacturing parts

Industrial X-ray computed tomography (XCT) enables non-destructive inspection of additively manufactured (AM) parts, but high-resolution scanning requires long acquisition times and significant computational resources, limiting throughput in production environments. Super-resolution techniques can recover high-resolution information from low-resolution scans, but existing methods face a trade-off between 2D approaches that ignore inter-slice information and 3D methods that are computationally prohibitive for practical deployment. To address this trade-off, we propose a 2.5D deep learning-based super-resolution approach that uses seven neighbouring low-resolution slices to super-resolve the centre slice. This work evaluates the method on real XCT scans of steel AM parts, comparing reconstruction quality and flaw detection performance of 2D, 2.5D, and 3D ESRGAN-based super-resolution methods. Results demonstrate that 2.5D super-resolution significantly improves detection of small, process-induced flaws (e.g. porosity) compared to 2D methods, while avoiding the prohibitive computational burden of full 3D approaches. These findings provide initial evidence of 2.5D super-resolution as a practical, deployable solution for improving flaw detection in high-throughput industrial XCT inspection.

X-ray CT↗