Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Interaction of Water with Carbon Fiber Reinforced Polymer Laminates under Dynamic Loading Conditions

With the aim of simulating the real conditions during the navigation, in this framework, impact tests were performed by loading CFRP laminates immersed in the water from the front side. The specimens, made by vinyl ester matrix because of the lower moisture absorption compared to the other epoxy systems, are in the presence of the water to accurately simulate the incidental impact on the hull of the vessel, immersed or partially immersed, during the navigation. It can be caused by the ice in the Arctic Ocean, by a projectile due to a terroristic attack or by debris from an explosion. The results are compared with the ones obtained by loading the laminates in pure traditional impact tests in the air. The influence of the clamping device has been tested too. The exciting results obtained on carbon fiber laminates in the air (pure traditional impact tests), water-backed (with water on the back side) and waterfront (water only on the front side) conditions at room temperature are here reported and compared. They highlighted the critical role played by the complex fluid–structure interaction.

36 MATERIALS SCIENCE↗

Reverse-Bias Resilience of Monolithic Perovskite/Silicon Tandem Solar Cells

Metal halide perovskites have rapidly enabled a range of high-performance photovoltaic technologies. However, catastrophic failure under reverse voltage bias hinders their commercialization. In this work, we demonstrate that by employing a monolithic perovskite/silicon tandem structure, the perovskite subcell can be effectively protected by the silicon subcell under reverse bias, owing to the low reverse-bias diode current of the silicon subcell. As a result, the tested perovskite/silicon tandem devices show superior reverse-bias resilience compared to perovskite single-junction devices in both long-term reverse voltage biasing tests at the single-cell level and partial shading tests at the module level. These results highlight that, compared to other perovskite technologies, monolithic perovskite/silicon tandems are at a higher technology readiness level in terms of tackling the reverse-bias and partial shading challenge, which is a considerable advantage towards commercialization.

commercialization↗

A novel tensile device for in situ scanning electron microscope mechanical testing

To facilitate the study of deformation mechanisms and mechanical properties of bulk materials with feature size of centimeter level, a novel tensile device compatible with scanning electron microscope (SEM) was designed and built. Integrating the servo motor and three-stage reducer, the device could realize quasistatic loading mode with a loading speed of 10 nm/s. The device also presents broad compatibility with various types of SEMs due to its miniaturized dimensions and larger volume–output load ratio compared with existing and commercial tensile instruments. A small lead precise ball screw with left- and right-hand thread was adopted to keep the center of the specimen remain stationary without moving during the tensile testing. A novel gripping method was carefully taken into account to guarantee the alignment issues. The closed-loop control mode of the tensile process was developed. The displacement resolution of 40 nm was tested to verify the driving performance of the device. Furthermore, correction method on testing displacement was investigated based on the calibration experiments of the load sensor and displacement sensor, and the comparison tests based on stress–strain curve were carried out between the self-made device and the commercial tensile instrument (Instron 3345) to verify the feasibility and universality of the correction method.

36 MATERIALS SCIENCE↗

Technologies for node-degree based clustering of data sets

Technologies for node-degree based clustering include a computing device to construct a graph that includes multiple vertices corresponding to the data points of a data set. The computing device inserts an edge between each pair of vertices that has a corresponding similarity metric that meets a predetermined threshold similarity metric. The computing device determines a node degree for each vertex in the graph and initializes a cutoff node degree as the lowest node degree of the vertices. The computing device selects a test subset of the graph that includes vertices having a node degree less than or equal to the cutoff node degree. The computing device determines whether the test subset covers the graph and if not increases the cutoff node degree. If the test subset covers the graph, the data points corresponding to the vertices of the test subset are the representative cluster. Other embodiments are described and claimed.

Sitik, Ahmet Can↗

U.S. Navy Wave Energy Test Site – Early Findings.

The U.S. Navy’s Wave Energy Test Site (WETS), with three test berths at 30, 60, and 80m water depths, located on the windward side of the island of Oahu, Hawaii, in now fully operational. The first such grid-connected test site in the U.S., WETS has hosted two wave energy conversion (WEC) devices since its June 2015 commissioning – the Fred. Olsen Lifesaver (Figure 1) and Northwest Energy Innovations Azura. Both are point absorber WECs, but with very different configurations and power take off (PTO) strategies. Several additional devices will be tested at WETS in the coming years, beginning with an oscillating water column device from Ocean Energy in late 2017.

16 TIDAL AND WAVE POWER↗

NREL's Improved Linearity Testing of Photovoltaic Reference Cells

Photovoltaic devices are characterized under standard testing conditions that include a defined reference spectrum and total irradiance. International standards for reference cell calibrations require that reported reference cell response (typically Isc) vs. total irradiance must be linear. How can linearity be efficiently determined? In 2006 NREL developed a test bed, based on the "two-lamp method" that provided a low cost, but low accuracy method for determining whether cell response was linear with irradiance. This paper describes very simple changes to NREL's historical method [1] for determining linearity that yield greatly improved results. It also describes a method that can be used to quantify and correct for non-linearity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Thermionic emission and energy conversion

This project worked on development of a transformative heat-to-electricity conversion device based on thermionic energy conversion. The research provided a unique opportunity to transform the thermionics technology of the 1950-1990s by applying modern materials and 21st century wafer-scale fabrication methods. Research was conducted to further development of a thermionic energy converter based on modern microfabrication and new low work function anode materials that can surpass all other forms of direct heat-to-electricity conversion. This project completed the following goals: (1) Developed components for use in thermionic energy converters and electron emission devices, including electrode materials for electron emission and electron absorption with ultimate work functions below 5 eV; (2) Designed and fabricated thermionic devices for energy conversion and electron emission based on the components developed in (1); (3) Engineered test systems to characterize electronic, thermal, and mechanical properties of thermionic devices and electron emitters and their components, and test devices and components designed and fabricated in (1) and (2); and (4) Developed theoretical modeling capabilities in support of these technical objectives.

36 MATERIALS SCIENCE↗

GrayQb TM Single-Faced Version 2 (SF2) Open Environment Test Report (Rev. 1)

This report details the design upgrades incorporated into the new version of the GrayQb TM SF2 device and the characterization testing of this upgraded device. Results from controlled characterization testing in the Savannah River National Laboratory (SRNL) R&D Engineering Imaging and Radiation Lab (IRL) and the Savannah River Site (SRS) Health Physics Instrument Calibration Laboratory (HPICL) is presented, as well as results from the open environment field testing performed in the E-Area Low Level Waste Storage Area. Resultant images presented in this report were generated using the SRNL developed Radiation Analyzer (RAzer TM ) software program which overlays the radiation contour images onto the visual image of the location being surveyed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-260: Development of a System to Verify for Connection Consistency in a Brachytherapy

Purpose: Brachytherapy has multiple manual procedures which are prone to human error, especially during the connection process of the treatment device to applicator. This is when considerable attention is required. In this study, we propose a new connection verification device concept. Methods: The system is composed of a ring magnet (anisotropic ferrite : magfine Inc), hole device (A1324LUA-T : Allegro MicroSystems Phil Inc) and an in-house check cable, which is made from magnetic material (Figure1). The magnetic field distribution is affected by the check cable position and any magnetic field variation is detected by the hole device. This system frequency is 20Hz and the average of 4 signals was used as hole device value to reduce noise. Results: The value of the hole device is altered, depending on the location of the check cable. The resolution of the check cable position is 5mm and 10mm, around a 10mm region from the hole device and over 10mm, respectively. There was a reduction in sensitivity of the hole device, in our test, which was linked to the distance of the hole device from the check cable. Conclusion: We demonstrated a new concept of connection verification in a brachytherapy. This system has the possibility to detect an incorrect connection. Moreover, the system is capable of self-optimization, such as determining the number of hole device and the magnet strength.Acknowledgement:This work was supported by JSPS Core -to-Core program Number 23003 and KAKENHI Grant Number 26860401. This work was supported by JSPS Core-to-Core program Number 23003 and KAKENHI Grant Number 26860401.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid salt environment stress-rupture testing

Disclosed herein are systems, devices and methods for stress-rupture testing selected materials within a high-temperature liquid salt environment. Exemplary testing systems include a load train for holding a test specimen within a heated inert gas vessel. A thermal break included in the load train can thermally insulate a load cell positioned along the load train within the inert gas vessel. The test specimen can include a cylindrical gage portion having an internal void filled with a molten salt during stress-rupture testing. The gage portion can have an inner surface area to volume ratio of greater than 20 to maximize the corrosive effect of the molten salt on the specimen material during testing. Also disclosed are methods of making a salt ingot for placement within the test specimen.

36 MATERIALS SCIENCE↗

Hawai‘i National Marine Renewable Energy Center (HINMREC)

The Hawaii National Marine Renewable Energy Center (HINMREC) was established to facilitate the commercialization of wave energy converter (WEC) devices, and to accelerate development and testing of Ocean Thermal Energy Conversion (OTEC) technologies. Housed at the Hawaii Natural Energy Institute (HNEI) of the University of Hawaii (UH), this program started with execution of the contract between the US Department of Energy (DOE) and UH in March 2009, and activities ran through the end of the project in September 2019. The DOE tasked HINMREC with facilitating and accelerating the build-out of the Navy’s Wave Energy Test Site (WETS), the nation’s first grid-connected open water wave energy conversion test facility, located off Marine Corps Base Hawaii (MCBH) in Kaneohe, on the island of Oahu. WETS was expanded from an existing test berth at 30m water depth to include test berths at 60m and 80m water depths. In recognition of the high costs associated with at-sea testing and evaluation of WEC devices, it was deemed imperative that HINMREC seek ways to reduce costs to developers by providing key research support to these early-stage technologies. WETS and HINMREC’s support allowed development of wave energy technology by providing a testing infrastructure that allows technology developers to test, demonstrate and evaluate their WEC devices, and generate data in order to advance WEC designs toward commercial readiness. HINMREC’s roles have included support in the establishment of the full site, including of wave resource characterization and site survey, followed by the essential roles of independent WEC device power performance assessment and environmental monitoring in support of deployed pre-commercial WECs. This DOE-funded work transitioned effectively to continue Navy-funded tasks for OTEC development, and activities at WETS, now under Naval Facilities Engineering Command (NAVFAC) funding. A secondary objective in the establishment of HINMREC was to assist the private sector in moving OTEC systems beyond proof-of-concept to pre-commercialization, primarily focused on system and component engineering, and local and global investigations into the potential environmental impacts of OTEC systems. HINMREC was tasked with maintaining high-resolution models of ocean thermal resources and the potential sustainable power output of OTEC systems. Ongoing tests begun previously under Navy funding at the OTEC Heat Exchangers (HXs) Test Facility at the Natural Energy Laboratory of Hawaii Authority (NELHA), in Kona on Hawaii Island, have been continued to identify cost-effective aluminum alloys for use in OTEC systems operating in the corrosive marine environment.

16 TIDAL AND WAVE POWER↗

Development of a compact x-ray particle image velocimetry for measuring opaque flows

A compact x-ray particle image velocimetry (PIV) system employing a medical x-ray tube as a light source was developed to measure quantitative velocity field information of opaque flows. The x-ray PIV system consists of a medical x-ray tube, an x-ray charge coupled device camera, a programmable shutter for a pulse-type x ray, and a synchronization device. Through performance tests, the feasibility of the developed x-ray PIV system as a flow measuring device was verified. To check the feasibility of the developed system, we tested a tube flow at two different mean velocities of 1 and 2 mm/s. The x-ray absorption of tracer particles must be quite different from that of working fluid to have a good contrast in x-ray images. All experiments were performed under atmospheric pressure condition. This system is unique and useful for investigating various opaque flows or flows inside opaque conduits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-304-02: Robust and Efficient Process for Acceptance Testing of Varian TrueBeam Linacs Using An Electronic Portal Imaging Device (EPID)

Purpose: The purpose of this project was to develop a process that utilizes the onboard kV and MV electronic portal imaging devices (EPIDs) to perform rapid acceptance testing (AT) of linacs in order to improve efficiency and standardize AT equipment and processes. Methods: In this study a Varian TrueBeam linac equipped with an amorphous silicon based EPID (aSi1000) was used. The conventional set of AT tests and tolerances was used as a baseline guide, and a novel methodology was developed to perform as many tests as possible using EPID exclusively. The developer mode on Varian TrueBeam linac was used to automate the process. In the current AT process there are about 45 tests that call for customer demos. Many of the geometric tests such as jaw alignment and MLC positioning are performed with highly manual methods, such as using graph paper. The goal of the new methodology was to achieve quantitative testing while reducing variability in data acquisition, analysis and interpretation of the results. The developed process was validated on two machines at two different institutions. Results: At least 25 of the 45 (56%) tests which required customer demo can be streamlined and performed using EPIDs. More than half of the AT tests can be fully automated using the developer mode, while others still require some user interaction. Overall, the preliminary data shows that EPID-based linac AT can be performed in less than a day, compared to 2–3 days using conventional methods. Conclusions: Our preliminary results show that performance of onboard imagers is quite suitable for both geometric and dosimetric testing of TrueBeam systems. A standardized AT process can tremendously improve efficiency, and minimize the variability related to third party quality assurance (QA) equipment and the available onsite expertise. Research funding provided by Varian Medical Systems. Dr. Sasa Mutic receives compensation for providing patient safety training services from Varian Medical Systems, the sponsor of this study.

07 ISOTOPE AND RADIATION SOURCES↗

Equipment Testing Environment (ETE) Process Specification

This document is intended to be utilized with the Equipment Test Environment being developed to provide a standard process by which the ETE can be validated. The ETE is developed with the intent of establishing cyber intrusion, data collection and through automation provide objective goals that provide repeatability. This testing process is being developed to interface with the Technical Area V physical protection system. The document will overview the testing structure, interfaces, device and network logging and data capture. Additionally, it will cover the testing procedure, criteria and constraints necessary to properly capture data and logs and record them for experimental data capture and analysis.

97 MATHEMATICS AND COMPUTING↗

Fabrication and Evaluation of a High Performance SiC Inverter for Wireless Power Transfer Applications

In this study, a high power density SiC high efficiency wireless power transfer converter system via inductive coupling has been designed and developed. The detailed power module design, cooling system design and power stage development are presented. The successful operation of rated power converter system demonstrates the feasible wireless charging plan. One of the most important part of this study is the wind bandgap devices packaged at the Oak Ridge National Laboratory (ORNL) using the in-house packaging technologies by employing the bare SiC dies acquired from CREE, which are rated at 50 A / 1200 V each. These packaged devices are also inhouse tested and characterized using ORNL s Device Characterization Facility. The successful operation of the proposed inverter is experimentally verified and the efficiency and operational characteristics of the inverter are also revealed.

Onar, Omer C↗