Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Alpha Particle Diagnostic

The study of burning plasmas is the next frontier in fusion energy research, and will be a major objective of the U.S. fusion program through U.S. collaboration with our international partners on the ITER Project. For DT magnetic fusion to be useful for energy production, it is essential that the energetic alpha particles produced by the fusion reactions be confined long enough to deposit a significant fraction of their initial ~3.5 MeV energy in the plasma before they are lost. Development of diagnostics to study the behavior of energetic confined alpha particles is a very important if not essential part of burning plasma research. Despite the clear need for these measurements, development of diagnostics to study confined the fast confined alphas to date has proven extremely difficult, and the available techniques remain for the most part unproven and with significant uncertainties. Research under this grant had the goal of developing diagnostics of fast confined alphas, primarily based on measurements of the neutron and ion tails resulting from alpha particle knock-on collisions with the plasma deuterium and tritium fuel ions. One of the strengths of this approach is the ability to measure the alphas in the hot plasma core where the interesting ignition physics will occur.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Design of a New Optical System for Alcator C-Mod Motional Stark Effect Diagnostic

The motional Stark effect (MSE) diagnostic on Alcator C-Mod uses an in-vessel optical system (five lenses and three mirrors) to relay polarized light to an external polarimeter because port access limitations on Alcator C-Mod preclude a direct view of the diagnostic beam. The system experiences unacceptable, spurious drifts of order several degrees in measured pitch angle over the course of a run day. Recent experiments illuminated the MSE diagnostic with polarized light of fixed orientation as heat was applied to various optical elements. A large change in measured angle was observed as two particular lenses were heated, indicating that thermal-stress-induced birefringence is a likely cause of the spurious variability. Several new optical designs have been evaluated to eliminate the affected in-vessel lenses and to replace the focusing they provide with curved mirrors; however, ray tracing calculations imply that this method is not feasible. A new approach is under consideration that utilizes in situ calibrations with in-vessel reference polarized light sources. 2008 American Institute of Physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic Methodologies of Laser-Initiated 11 B(p,α)2α Fusion Reactions

The detection of the ionic products of low-rate fusion reactions, and in particular of the 11 B(p,α)2α, is one of the recognized main problems in experiments where these reactions are initiated by tailored interaction of intense and high-energy lasers with matter. A thorough description of this important issue, with a critical comparison of the diagnostic opportunities, is indeed so far. In this work, we describe the common diagnostic methodologies used for the detection of the alpha particles generated by the 11 B(p,α)2α reaction and, for each, we outline advantages and limitations, with considerations that can also be applied to other low-rate fusion reactions. We show here that, in general, the univocal characterization of the α products coming from this reaction can be achieved by the simultaneous use of several diagnostic tools placed in close proximity.

11B(p,α)2α reactions↗

An Ensemble Investigation of the Causes for Regional Air-Quality Model Critical Load Exceedances Prediction Variability in European and North American Domains Using Diagnostics From Phase 4 of the Air Quality Model Evaluation International Initiative

We summarize tentative findings from multi air quality model ensembles for the years 2009 and 2010 in Europe (EU), and 2010 and 2016 in North America (NA), under AQMEII-4. The model predictions of sulphur and nitrogen deposition were used to estimate exceedances of critical loads for acidification and eutrophication, to show the extent to which the ensemble members agree in the magnitude and the trend of ecologically meaningful impacts. Model exceedance variability was analyzed using AQMEII-4 diagnostics. Evaluation against concentration and wet deposition observations, coupled with these diagnostics, identified specific process representations as the causes for variability between model predictions and for reduced model performance. All models predicted reductions in ecosystem acidification impacts in North America between the years 2010 and 2016, in accord with SO2 emissions reduction legislation which started in 2010 (SO2 SIP) However, all models in EU and NA domains had net negative biases for wet deposition of sulphur and nitrogen relative to observations. The wet S deposition average mean bias for the NA ensemble was -0.17 eq ha-1 d-1, and for the EU ensemble -1.15 eq ha-1 d-1. The NA daily wet deposition average mean bias for NH4+ was -0.37 eq ha-1d-1; EU -1.19 eq ha-1 d-1. The daily NA wet NO3- deposition average mean bias was -0.24 eq ha-1d-1; EU -0.69 eq ha-1 d-1. The members of the ensemble diverged (factor of 10) in their North American predictions for Ndep and consequently their eutrophication exceedances. The models with the highest eutrophication predictions also predicted the highest levels of gas-phase ammonia dry deposition (standard deviation of ammonia dry deposition flux across ensemble members was larger than the ensemble average). These models also had negative biases of predicted ammonia concentrations; average mean biases of -0.63 (satellite NH3) and -0.85 ppbv (surface NH3) compared to ensemble averages of -0.30 and -0.34 ppbv. Diagnostics showed that these differences resulted from the manner in which bidirectional ammonia fluxes were parameterized within these models. The second largest source of NA eutrophication prediction variability were models with positive biases in particulate ammonium and nitrate concentrations, and higher particle nitrogen deposition levels ( particle ammonium concentration bias +0.35 ug m-3; ensemble bias +0.15 ug m-3). We believe two factors may have led to these latter overestimates: higher levels of fine mode particle nitrate formation compared to other models (due to the use of an inorganic heterogeneous chemistry algorithm which did not take base cation chemistry into account), and updates to particle dry deposition velocities carried out in the absence of concurrent updates to wet scavenging algorithms. The relative importance of dry gas, dry particulate, and wet deposition towards total sulphur and nitrogen deposition totals differed between EU and North American domains, though all models had negative biases in wet deposition as noted above. Parallel and subsequent work suggests that multiphase hydrometeor scavenging may improve model wet deposition performance. An increased research focus is recommended for four model processes: multiphase hydrometeor scavenging, ammonia bidirectional fluxes, base cation chemistry and emissions, and particle dry deposition.

regional air-quality model↗

Evaluation of Temporal Diagnostic Techniques for Two-Bunch Facet Beam

Three temporal diagnostic techniques are considered for use in the FACET facility at SLAC, which will incorporate a unique two-bunch beam for plasma wakefield acceleration experiments. The results of these experiments will depend strongly on the the inter-bunch spacing as well as the longitudinal profiles of the two bunches. A reliable, singleshot, high resolution measurement of the beam's temporal profile is necessary to fully quantify the physical mechanisms underlying the beam driven plasma wakefield acceleration. In this study we show that a transverse deflecting cavity is the diagnostic which best meets our criteria. Based on our laboratory testing, numerical calculations, and simulations of the three single-shot temporal diagnostic devices, the X-band TCAV system is the best candidate for resolving FACET's two-bunch beam, with an estimated resolution of 7 {micro}m. Both the S-band TCAV system and the EO system could resolve the peak-to-peak separation of the two bunches in the FACET beam with estimated resolutions of 25 {micro}m and 30 {micro}m, respectively, but would be unable to resolve the temporal profiles of the individual bunches themselves. Because the TCAV signal is more easily interpreted and because the reliability of the EO system is less well known, however, the S-band TCAV system would be the next preferred option after the X-band TCAV system. The Fesca-200 streak camera, though simple, compact, and reliable, is unable to achieve a resolution that would be of use to FACET.

43 PARTICLE ACCELERATORS↗

LASER BASED DIAGNOSTICS FOR MEASURING H- BEAM PARAMETERS

In recent years, a number of laser based H- beam diagnostics systems have been developed in the Spallation Neutron Source (SNS). This talk reviews three types of laser-based diagnostics at SNS: the laser wire profile monitors at superconducting linac (SCL), the laser based transverse emittance measurement system at high energy beam transport (HEBT), and the laser bunch shape monitor at medium energy beam transport (MEBT). Measurement performance will be reported and major technical challenges in the design, implementation, and operation of the laser based diagnostics at accelerator facilities will be addressed.

43 PARTICLE ACCELERATORS↗

LASER APPLICATIONS: H- BEAM PHOTO-DETACHMENT AND PUSH BUTTON DIAGNOSTICS

The laser based nonintrusive H- beam diagnostics and laser assisted H- beam stripping technologies have been developed at the Spallation Neutron Source (SNS). This paper reviews the present status of the SNS laser based diagnostics and the recent R&D progress on the fiber transmission of laser pulses and power enhancement optical cavity which will be used in diagnostics and laser stripping.

diagnostics↗

First results from the Thomson scattering diagnostic on Proto-MPEX

A Thomson scattering diagnostic has been successfully implemented on the prototype Material Plasma Exposure eXperiment (Proto-MPEX) at Oak Ridge National Laboratory. The diagnostic collects the light scattered by plasma electrons and spectroscopically resolves the Doppler shift imparted to the light by the velocity of the electrons. The spread in velocities is proportional to the electron temperature, while the total number of photons is proportional to the electron density. Thomson scattering is a technique used on many devices to measure the electron temperature (Te) and electron density (ne) of the plasma. A challenging aspect of the technique is to discriminate the small number of Thomson scattered photons against the large peak of background photons from the high-power laser used to probe the plasma. A variety of methods are used to mitigate the background photons in Proto-MPEX, including Brewster angled windows, viewing dumps, and light baffles. With these methods, first results were measured from Argon plasmas in Proto-MPEX, indicating Te ~ 2 eV and ne ~ 1x1019 m-3. The configuration of the Proto-MPEX Thomson scattering diagnostic will be described and plans for improvement will be given.

plasma diagnostics thomson scattering↗

The Roles and Developments needed for Diagnostics in the ITER Fusion Device

Harnessing the power from Fusion on earth is an important and challenging task. Excellent work has been carried out in this area over the years with several demonstrations of the ability to produce power. Now, a new large device is being constructed in the south of France. This is called ITER. ITER is a large-scale scientific experiment that aims to demonstrate a possibility to produce commercial energy from fusion. This project is now well underway with the many teams working on the construction and completing various aspects of the design. This device will carry up to 15 MA of plasma current and produce about 500 MW of power, 400 MW approximately in high energy neutrons. The typical temperatures of the electrons inside this device are in the region of a few hundred million Kelvin. It is maintained using a magnetic field. This device is pushing several boundaries from those currently existing. As a result of this, several technologies need to be developed or extended. This is especially true for the systems or diagnostics that measure the performance and provide the control signals for this device. A diagnostic set will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include amongst others, measurements of the plasma shape, temperature, density, impurity concentration, and particle and energy confinement times. The system will comprise about 45 individual measuring systems drawn from the full range of modern plasma diagnostic techniques, including magnetics, lasers, X-rays, neutron cameras, impurity monitors, particle spectrometers, radiation bolometers, pressure and gas analysis, and optical fibres. These devices will have to be made to work in the new and challenging environment inside the vacuum vessel. These systems will have to cope with a range of phenomena that extend the current knowledge in the Fusion field. One amongst them is the parasitic effect of the neutrons on the while all the performing with great accuracy and precision. The levels of neutral particle flux, neutron flux and neutron fluence will be respectively about 5, 10 and 10,000 times higher than the harshest experienced in today's machines. The pulse length of the fusion reaction-or the amount of time the reaction is sustained-will be about 100 times longer. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polarimetry-Interferometry Diagnostic for Magnetic Field and Magnetic Fluctuation Measurements in High-Performance and Long-Pulse Tokamaks (Final Report)

In this grant, we executed a multi-year plan to develop an advanced Faraday-effect polarimeter-interferometer system to address both fluctuation and equilibrium diagnostic needs by providing a measurement of the plasma internal magnetic field fluctuations (including non-axisymmetric 3-D perturbations) and plasma vertical position. This diagnostic included both fast time response and low phase noise so that both the temporal dynamics of equilibrium quantities as well as high-frequency electromagnetic fluctuations could be measured simultaneously, adding new and unique measurement capabilities for the core of high-temperature plasmas. The combined polarimeter-interferometer diagnostic development was applied primarily to the tokamak magnetic configuration, focusing on high-performance regimes including H-mode, reversed shear advanced tokamak scenarios, and non-inductive current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integration of Condition-Based, Diagnostic, Prognostic, And Anomaly Detection Data into Reliability Models to Support a Predictive Maintenance Context

Reliability data employed in plant reliability models are an approximated integral representation of the past industrywide operational experience, and they neglect the present asset health status (available, for example, from online monitoring data and diagnostic assessments) and forecasted health projection (when available from prognostic models). Ideally, in a predictive maintenance context, system reliability models should support decision making by propagating actual health information from the asset to the system level in order to provide a quantitative snapshot of system health and identify the most critical assets. Asset health should be informed solely by that specific asset’s current and historical performance data and should not be an approximated integral representation of the past industrywide operational experience (as currently performed by system reliability models through Bayesian updating processes). This paper proposes a reliability modeling approach that relies on asset diagnostic and prognostic assessments, along with monitoring data to measure asset health. We show how state-of-the art condition-based, diagnostic, prognostic, and anomaly detection models can be linked to system reliability models not in probability terms, but in terms of margin where margin is defined as the “distance” between the present status and an undesired event (e.g., failure or unacceptable performance). Then, we show how the propagation of margin data from the asset to the system level is performed through classical reliability models such as fault trees or reliability block diagrams. The described method is in fact able to propagate heterogenous health data from the asset to the system level in order to analytically assess system health.

97 MATHEMATICS AND COMPUTING↗

Digital Time-Resolved Spot Diagnostic

The digital time-resolved spot diagnostic (D-TRSD) is a fast-response, time-dependent beam diagnostic for measuring the emitted spot size and beam target interactions from radiographic x-ray sources. Legacy streaked TRSD analysis requires image processing and data extraction, which give noisy results. Processed data are used to extract edge spread and corresponding line spread functions. Digital TRSD simplifies this process, eliminating the complexity of streak camera–based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation dose in coronary angiography and intervention: initial results from the establishment of a multi-centre diagnostic reference level in Queensland public hospitals

Radiation dose to patients undergoing invasive coronary angiography (ICA) is relatively high. Guidelines suggest that a local benchmark or diagnostic reference level (DRL) be established for these procedures. This study sought to create a DRL for ICA procedures in Queensland public hospitals. Data were collected for all Cardiac Catheter Laboratories in Queensland public hospitals. Data were collected for diagnostic coronary angiography (CA) and single-vessel percutaneous intervention (PCI) procedures. Dose area product (P{sub KA}), skin surface entrance dose (K{sub AR}), fluoroscopy time (FT), and patient height and weight were collected for 3 months. The DRL was set from the 75th percentile of the P{sub KA.} 2590 patients were included in the CA group where the median FT was 3.5 min (inter-quartile range = 2.3–6.1). Median K{sub AR} = 581 mGy (374–876). Median P{sub KA} = 3908 uGym{sup 2} (2489–5865) DRL = 5865 uGym{sup 2}. 947 patients were included in the PCI group where median FT was 11.2 min (7.7–17.4). Median K{sub AR} = 1501 mGy (928–2224). Median P{sub KA} = 8736 uGym{sup 2} (5449–12,900) DRL = 12,900 uGym{sup 2}. This study established a benchmark for radiation dose for diagnostic and interventional coronary angiography in Queensland public facilities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating radiographers' diagnostic accuracy in screen-reading mammograms: what constitutes a quality study?

The aim of this study was to first evaluate the quality of studies investigating the diagnostic accuracy of radiographers as mammogram screen-readers and then to develop an adapted tool for determining the quality of screen-reading studies. A literature search was used to identify relevant studies and a quality evaluation tool constructed by combining the criteria for quality of Whiting, Rutjes, Dinnes et al. and Brealey and Westwood. This constructed tool was then applied to the studies and subsequently adapted specifically for use in evaluating quality in studies investigating diagnostic accuracy of screen-readers. Eleven studies were identified and the constructed tool applied to evaluate quality. This evaluation resulted in the identification of quality issues with the studies such as potential for bias, applicability of results, study conduct, reporting of the study and observer characteristics. An assessment of the applicability and relevance of the tool for this area of research resulted in adaptations to the criteria and the development of a tool specifically for evaluating diagnostic accuracy in screen-reading. This tool, with further refinement and rigorous validation can make a significant contribution to promoting well-designed studies in this important area of research and practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Megahertz Rate Optical Diagnostics of Explosively Generated Soot

Detonation of a solid explosive produces a turbulent and luminous post‐detonation fireball containing condensed carbon soot. Diagnostics of soot dynamics are needed for model validation and to interpret emission signals. Diffuse back‐illumination extinction imaging (DBI‐EI) and laser‐induced incandescence (LII) are two common optical diagnostics for flame soot. This work extends both to measure time‐resolved soot dynamics from a 12 mm HMX hemisphere. DBI‐EI measured line‐of‐sight optical extinction exceeds 99% in some regions. Results are tomographically inverted to obtain a signal proportional to the soot volume fraction. Pulse‐burst LII measures are presented at 1 MHz. For the first time, LII results are combined with DBI‐EI extinction measurements to quantify and correct for signal trapping. Following this, spatially and temporally resolved DBI‐EI and LII measures are shown to be in reasonable agreement. Finally, experimental results are compared against recently developed simulations. Quantitative differences in the soot mixing dynamics are resolved. These findings motivate future model improvements and demonstrate ongoing needs for diagnostic advancements for heavily sooting environments.

diffuse back-illumination extinction imaging↗

Diagnostic performance of F-18 FDG PET/CT for prediction of KRAS mutation in colorectal cancer patients: a systematic review and meta-analysis

Objective: The purpose of the current study was to investigate the diagnostic performance of F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for the prediction of v-Ki-ras-2 Kirsten rat sarcoma viral oncogene homolog (KRAS) mutation in colorectal cancer (CRC) patients through a systematic review and meta-analysis. Methods: The PubMed and EMBASE database, from the earliest available date of indexing through April 30, 2018, were searched for studies evaluating the diagnostic performance of F-18 FDG PET/CT for prediction of KRAS mutation in CRC patients. Results: Across 9 studies (804 patients), the pooled sensitivity for F-18 FDG PET/CT was 0.66 (95% CI 0.60–0.73) without heterogeneity (I{sup 2} = 34.1, p = 0.14) and a pooled specificity of 0.67 (95% CI 0.62–0.72) without heterogeneity (I{sup 2} = 1.63, p = 0.42). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 2.0 (95% CI 1.7–2.4) and negative likelihood ratio (LR−) of 0.5 (95% CI 0.41–0.61). The pooled diagnostic odds ratio (DOR) was 4 (95% CI 3–6). Hierarchical summary receiver operating characteristic (ROC) curve indicates that the areas under the curve were 0.69 (95% CI 0.65–0.73). Conclusion: The current meta-analysis showed the low sensitivity and specificity of F-18 FDG PET/CT for prediction of KRAS mutation in CRC patients. The DOR was very low and the likelihood ratio scatter-gram indicated that F-18 FDG PET/CT might not be useful for prediction of KRAS mutation and not for its exclusion. Therefore, cautious application and interpretation should be paid to the F-18 FDG PET/CT for prediction of KRAS mutation in CRC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improvement of prostate cancer detection combining a computer-aided diagnostic system with TRUS-MRI targeted biopsy

Purpose: To validate a novel consensus method, called target-in-target, combining human analysis of mpMRI with automated CAD system analysis, with the aim to increasing the prostate cancer detection rate of targeted biopsies. Methods: A cohort of 420 patients was enrolled and 253 patients were rolled out, due to exclusion criteria. 167 patients, underwent diagnostic 3T MpMRI. Two expert radiologists evaluated the exams adopting PI-RADSv2 and CAD system. When a CAD target overlapped with a radiologic one, we performed the biopsy in the overlapping area which we defined as target-in-target. Targeted TRUS-MRI fusion biopsy was performed in 63 patients with a total of 212 targets. The MRI data of all targets were quantitatively analyzed, and diagnostic findings were compared to pathologist’s biopsy reports. Results: CAD system diagnostic performance exhibited sensitivity and specificity scores of 55.2% and 74.1% [AUC = 0.63 (0.54 ÷ 0.71)] , respectively. Human readers achieved an AUC value, in ROC analysis, of 0.71 (0.63 ÷ 0.79). The target-in-target method provided a detection rate per targeted biopsy core of 81.8 % vs. a detection rate per targeted biopsy core of 68.6 % for pure PI-RADS based on target definitions. The higher per-core detection rate of the target-in-target approach was achieved irrespective of the presence of technical flaws and artifacts. Conclusions: A novel consensus method combining human reader evaluation with automated CAD system analysis of mpMRI to define prostate biopsy targets was shown to improve the detection rate per biopsy core of TRUS-MRI fusion biopsies. Results suggest that the combination of CAD system analysis and human reader evaluation is a winning strategy to improve targeted biopsy efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous ureteral biopsy: safety and diagnostic yield

Purpose: To evaluate safety and diagnostic yield of percutaneous CT-guided biopsy of extrarenal upper urinary tract lesions. Materials and methods: Retrospective review of our institutional database of image-guided biopsies yielded 44 CT-guided percutaneous biopsies in 44 unique patients that targeted ureteral (30, 68%) or other non-renal upper urinary tract lesions (14, 32%) between January 1, 2000 and May 1, 2017. Indications, pre-biopsy imaging, biopsy technique, peri-procedural antithrombotic use, complications including bleeding defined by Society of Interventional Radiology criteria, pathology results, and subsequent imaging were reviewed up to 3 months after the procedure to evaluate safety and diagnostic yield. Results: Mean patient age was 66 (range 27–88) and 23/44 patients were male. The majority (34/44) of lesions were sampled with an 18-gauge biopsy device via a 17-gauge introducer needle, and the remaining 10/44 lesions were sampled with a 19/20 gauge system. The mean number of core samples obtained was 4 (range 2–10). No major complications occurred. Specifically, no patient developed a urine leak or urinary obstruction. Minor complications occurred in 3/44 (7%) biopsies, all retroperitoneal hemorrhages that did not require transfusion or other intervention. Biopsy was adequate for pathologic examination in 41 of 44 (93%) cases. Among patients undergoing surgical resection, biopsy diagnosis was concordant with surgical pathology in 9/10 (90%) cases and discordant in 1/10 (10%). Conclusion: CT-guided percutaneous biopsy of upper urinary tract lesions can be performed safely, with high diagnostic yield, and with a high rate of concordance on subsequent surgical pathology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗