Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct simulation Monte Carlo methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

SU-C-204-03: In-Vivo Range Verification and Tissue Response to Proton Radiotherapy Using Prompt Gamma Volume Histograms

Purpose: To study if prompt gamma (PG) volume histograms created from PG images acquired during treatment delivery can be used to identify changes to beam range and tissue composition in response to proton radiotherapy. Methods: Monte Carlo simulations of a single field from a single treatment fraction (100 cGy) for prostate cancer were performed for the cases of: 1) an ideal patient setup, 1) a setup shift in the superior direction and 2) a reduction in oxygen concentration in the tumor. For each case, the 3 -Dimsional dose delivery and elemental PG emission in the patient for the treatment fraction were recorded and imported into a commercial treatment planning system. Changes in the dose volume histograms (DVH), as well as the PG volume histograms (PG-VH) for the PG emission from oxygen and for the total PG emission (from all elements) were analyzed. Results: For the 1 cm superior shift, the prostate DVH and total PG-VH both shifted toward lower doses with the shape of the curves remaining nearly unchanged, resulting in the DVH V95 dropping from 100 cGy to 90 cGy. For the total PG-VH, the V95 fell from 50 to 38. For the reduced oxygen case, both the DVH and PG-VH had a much different shape than for the ideal case, with a significant downward slope in the curves as a function of dose. Conclusions: The shift in the prostate PG-VH for a superior shift in the patient setup correlated well with the DVH indicating it is possible to detect setup errors by analyzing the PG-VH from prompt gamma images obtained during daily proton treatment delivery. Additionally, it may be possible to detect changes in the elemental concentrations of irradiated tissues by analyzing the shape of the PG-VH.

60 APPLIED LIFE SCIENCES↗

Oxygen transport properties estimation by classical trajectory–direct simulation Monte Carlo

Coupling direct simulation Monte Carlo (DSMC) simulations with classical trajectory calculations is a powerful tool to improve predictive capabilities of computational dilute gas dynamics. The considerable increase in computational effort outlined in early applications of the method can be compensated by running simulations on massively parallel computers. In particular, Graphics Processing Unit acceleration has been found quite effective in reducing computing time of classical trajectory (CT)-DSMC simulations. The aim of the present work is to study dilute molecular oxygen flows by modeling binary collisions, in the rigid rotor approximation, through an accurate Potential Energy Surface (PES), obtained by molecular beams scattering. The PES accuracy is assessed by calculating molecular oxygen transport properties by different equilibrium and non-equilibrium CT-DSMC based simulations that provide close values of the transport properties. Comparisons with available experimental data are presented and discussed in the temperature range 300–900 K, where vibrational degrees of freedom are expected to play a limited (but not always negligible) role.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo Simulations of Crystal Defects in Open Ensembles

Zero- and two-dimensional crystal defects form in open statistical ensembles, such as the grand canonical, that are usually inaccessible with conventional simulation techniques. This longstanding challenge is overcome with a new Hamiltonian Monte Carlo method that samples energy-biased gradual transformations. In conclusion, the method enables free energy calculations for nonideal point defects and the direct prediction of finite-temperature interface structures.

Grain boundaries↗

An Integrated Simulation of Multiple-Pass U-10Mo Alloy Hot Rolling and Static Recrystallization

To achieve a desired microstructure and minimize the thickness variation in rolled foils, researchers must understand the effects of foil fabrication process variables on microstructure evolution. We developed an integrated simulation of deformation and recrystallization that employs the finite element method (FEM) and the kinetic Monte Carlo (KMC) Potts model, respectively, to investigate microstructure evolution during multiple-pass hot rolling and heat treatment in polycrystalline U-10Mo fuel. Scanning electron microscopy and electron backscatter diffraction images of microstructures were directly used as input in FEM calculation of deformation, and the calculated strains were used to determine the driving force of nucleation and growth of recrystallized grains in the Potts model. Grain structures predicted by the Potts model were used to update the grain structure and material properties for FEM. Simulation alternated between FEM and the Potts model to simulate grain structure evolution during multiple rolling and heat treatments. The initial model parameters were determined by benchmarking the recrystallization kinetics against experimental data. Then, the model was applied to predict the grain structure evolution. Results showed that our model can capture the coupling between deformation and recrystallization and can quantitatively reproduce the observed U-10Mo recrystallization and grain growth kinetics. The simulation results demonstrated that the developed model can predict U-10Mo grain structures as a function of initial microstructure and foil fabrication parameters.

36 MATERIALS SCIENCE↗

SU-E-T-464: On the Equivalence of the Quality Correction Factor for Pencil Beam Scanning Proton Therapy

Purpose: In current practice, most proton therapy centers apply IAEA TRS-398 reference dosimetry protocol. Quality correction factors (kQ) take into account in the dose determination process the differences in beam qualities used for calibration unit and for treatment unit. These quality correction factors are valid for specific reference conditions. TRS-398 reference conditions should be achievable in both scattered proton beams (i.e. DS) and scanned proton beams (i.e. PBS). However, it is not a priori clear if TRS-398 kQ data, which are based on Monte Carlo (MC) calculations in scattered beams, can be used for scanned beams. Using TOPAS-Geant4 MC simulations, the study aims to determine whether broad beam quality correction factors calculated in TRS-398 can be directly applied to PBS delivery modality. Methods: As reference conditions, we consider a 10×10×10 cm{sup 3} homogeneous dose distribution delivered by PBS system in a water phantom (32/10 cm range/modulation) and an air cavity placed at the center of the spread-out-Bragg-peak. In order to isolate beam differences, a hypothetical broad beam is simulated. This hypothetical beam reproduces exactly the same range modulation, and uses the same energy layers than the PBS field. Ion chamber responses are computed for the PBS and hypothetical beams and then compared. Results: For an air cavity of 2×2×0.2 cm{sup 3}, the ratio of ion chamber responses for the PBS and hypothetical beam qualities is 0.9991 ± 0.0016. Conclusion: Quality correction factors are insensitive to the delivery pattern of the beam (broad beam or PBS), as long as similar dose distributions are achieved. This investigation, for an air cavity, suggests that broad beam quality correction factors published in TRS-398 can be applied for scanned beams. J. Sorriaux is financially supported by a public-private partnership involving the company Ion Beam Applications (IBA)

07 ISOTOPE AND RADIATION SOURCES↗

On the microstructure of thin films grown by an isotropically directed deposition flux

The influence of isotropically directed deposition flux on the formation of the thin film microstructure at low temperatures is studied. For this purpose we have deposited TiO{sub 2} thin films by two different deposition techniques: reactive magnetron sputtering, in two different experimental configurations, and plasma enhanced chemical vapor deposition. The obtained results indicate that films grown under conditions where deposition particles do not possess a clear directionality, and in the absence of a relevant plasma/film interaction, present similar refractive indices no matter the deposition technique employed. The film morphology is also similar and consists of a granular surface topography and a columnarlike structure in the bulk whose diameter increases almost linearly with the film thickness. The deposition has been simulated by means of a Monte Carlo model, taking into account the main processes during growth. The agreement between simulations and experimental results indicates that the obtained microstructures are a consequence of the incorporation of low-energy, isotropically directed, deposition particles.

36 MATERIALS SCIENCE↗

Modeling rarefied gas chemistry with QuiPS, a novel quasi-particle method

The goal of this work is to build up the capability of quasi-particle simulation (QuiPS), a novel flow solver, such that it can adequately model the rarefied portion of an atmospheric reentry trajectory. Direct simulation Monte Carlo (DSMC) is the conventional solver for such conditions, but struggles to resolve transient flows, trace species, and high-level internal energy states due to stochastic noise. Quasi-particle simulation (QuiPS) is a novel Boltzmann solver that describes a system with a discretized, truncated velocity distribution function. The resulting fixed-velocity, variable weight quasi-particles enable smooth variation of macroscopic properties. The distribution function description enables the use of a variance-reduced collision model, greatly minimizing expense near equilibrium. This work presents the addition of a neutral air chemistry model to QuiPS and some demonstrative 0D simulations. The explicit representation of internal distributions in QuiPS reveals some of the flaws in existing physics models. Overall, variance reduction, a key feature of QuiPS, can greatly reduce expense of multi-dimensional calculations, but is only cheaper when the gas composition is near chemical equilibrium.

42 ENGINEERING↗

Partial relay selection in mixed RF/FSO dual-hop system over unified M-distributed fading channel with non-zero boresight pointing errors

In this paper, the performance of a partial relay selection-based amplify-and-forward mixed radio frequency/free space optical (RF/FSO) system with a direct RF link and outdated channel state information (CSI) is presented. The source-to-relay and source-to-destination RF links are subjected to Rayleigh distributions while the relay-to-destination FSO link experiences Malaga (M)-distribution with generalized non-zero boresight pointing errors. It is also assumed that selection combining diversity with heterodyne detection is considered for the signal reception at the destination. Moreover, the cumulative distribution functions of the end-to-end signal-to-noise under the influence of with/or without a direct link are then derived for the concerned system. Through this, the closed-form expressions for the system outage probability and average bit error rate are obtained. Thus, the influence of atmospheric turbulence, outdated CSI and relay selection are evaluated for the system under zero boresight and non-zero boresight displacement pointing errors scenarios. The results illustrated that the mixed RF/FSO system with a direct link offers better performance than the one without a direct link. The accuracy of the presented results is validated by Monte-Carlo simulation.

42 ENGINEERING↗

TU-H-CAMPUS-IeP1-04: Combined Organ Dose for Digital Subtraction Angiography and Computed Tomography Using Monte Carlo Simulation

Purpose: The purpose of this study was to evaluate the combined organ dose of digital subtraction angiography (DSA) and computed tomography (CT) using a Monte Carlo (MC) simulation on the abdominal intervention. Methods: The organ doses for DSA and CT were obtained with MC simulation and actual measurements using fluorescent-glass dosimeters at 7 abdominal portions in an Alderson-Rando phantom. DSA was performed from three directions: posterior anterior (PA), right anterior oblique (RAO), and left anterior oblique (LAO). The organ dose with MC simulation was compared with actual radiation dose measurements. Calculations for the MC simulation were carried out with the GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. Finally, the combined organ dose for DSA and CT was calculated from the MC simulation using the X-ray conditions of a patient with a diagnosis of hepatocellular carcinoma. Results: For DSA from the PA direction, the organ doses for the actual measurements and MC simulation were 2.2 and 2.4 mGy/100 mAs at the liver, respectively, and 3.0 and 3.1 mGy/100 mAs at the spinal cord, while for CT, the organ doses were 15.2 and 15.1 mGy/100 mAs at the liver, and 14.6 and 13.5 mGy/100 mAs at the spinal cord. The maximum difference in organ dose between the actual measurements and the MC simulation was 11.0% of the spleen at PA, 8.2% of the spinal cord at RAO, and 6.1% of left kidney at LAO with DSA and 9.3% of the stomach with CT. The combined organ dose (4 DSAs and 6 CT scans) with the use of actual patient conditions was found to be 197.4 mGy for the liver and 205.1 mGy for the spinal cord. Conclusion: Our method makes it possible to accurately assess the organ dose to patients for abdominal intervention with combined DSA and CT.

60 APPLIED LIFE SCIENCES↗

Simulation of the Parameters of a Titanium-Tritide-Based Beta-Voltaic Cell

The simulation of β-voltaic power cells consisting of a combined β-source and a converter was performed. The TiT{sub 2} compound containing the radioactive tritium isotope was selected as the source. As the converter, structures based on semiconductor materials, most commonly used in developing power cells, i.e., Si, SiC, GaAs, were considered. Using the Monte Carlo method, the main source parameters were calculated, in particular, the maximum achievable short-circuit current was estimated.

30 DIRECT ENERGY CONVERSION↗

The random-bond Ising model in 2.01 and 3 dimensions

We consider the Ising model between 2 and 4 dimensions perturbed by quenched disorder in the strength of the interaction between nearby spins. In the interval 2 < d < 4 this disorder is a relevant perturbation that drives the system to a new fixed point of the renormalization group. At d = 2 such disorder is marginally irrelevant and can be studied using conformal perturbation theory. Combining conformal perturbation theory with recent results from the conformal bootstrap we compute some scaling exponents in an expansion around d = 2. If one trusts these computations also in d =3, one finds results consistent with experimental data and Monte Carlo simulations. In addition, we perform a direct uncontrolled computation in d= 3 using new results for low-lying operator dimensions and OPE coefficients in the 3d Ising model. We compare these new methods with previous studies. Finally, we comment about the O(2) model in d = 3, where we predict a large logarithmic correction to the infrared scaling of disorder.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of radiography applications using x-ray beams emitted by compact accelerators. Part I. Monte Carlo study of the hard x-ray spectrum

Purpose: A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x rays emitted from thin targets, irradiated by electron beams circulating in the storage ring, is of primary interest for the design and the characterization of a beamline. This article, Part I, aims at optimizing some of the parameters which are critical for the design of medical applications based on the above compact light source. The goal was to evaluate the dependence of photon fluence and beam monochromaticity on electron-beam energy, target material, and thickness. Methods: The transport of 6 and 20 MeV electrons in a thin molybdenum, rhodium, and tungsten target is studied by means of Monte Carlo simulations using MCNPX. Configurations of the x-ray output port, different from the default forward-directed emission of the beam, are also investigated. A comparison with reference spectra for general diagnostic radiology and mammography is carried out. Results: It is shown that the emitted x-ray beams can be far more intense than those generated by conventional x-ray tubes for radiography applications. The profiles of the calculated polychromatic spectra resemble those generated by conventional x-ray tubes, with x-ray energies up to the energy of the incident-electron beam. An appreciable improvement in the monochromaticity of the beams can be obtained by viewing the x-ray emission from an output port antiparallel to the direction of the incident-electron beam. Conclusions: The optimum target thickness for tungsten target spectra is practically constrained by a trade-off between bremsstrahlung efficiency and focal-spot size requirements. A larger margin for optimization of target thickness is probably available for mammographic spectra. The constraint of a backward-directed (or, to a lesser extent, orthogonal) output port is to be considered mandatory for minimizing the high-energy tail of the spectral distribution and keeping the radiation dose to a reasonable level. It is also fundamental to evaluate the impact of the high-energy tail of the emitted spectra in x-ray imaging applications, since the energy range involved is significantly beyond the diagnostic range. This topic will be dealt with in Part II of the article.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Columnar phase in the Stockmayer model

Monte Carlo numerical simulation of the Stockmayer model is performed for particles with a sufficiently large dipole moment (m* {<=} 4.2). At concentrations 0.16 < {rho} < 0.31, a columnar phase is found which consists of parallel cylindrical layers, the particles forming a crystal structure in each cylinder with their dipoles codirected and parallel to the cylinder axis. The dipoles of nearest cylinders have opposite directions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determining Atomistic SAXS Models of Tri-Ubiquitin Chains from Bayesian Analysis of Accelerated Molecular Dynamics Simulations

Small-angle X-ray scattering (SAXS) has become an increasingly popular technique for characterizing the solution ensemble of flexible biomolecules. However, data resulting from SAXS is typically low-dimensional and is therefore difficult to interpret without additional structural knowledge. In theory, molecular dynamics (MD) trajectories can provide this information, but conventional simulations rarely sample the complete ensemble. Here, we demonstrate that accelerated MD simulations can be used to produce higher quality models in shorter time scales than standard simulations, and we present an iterative Bayesian Monte Carlo method that is able to identify multistate ensembles without overfitting. This methodology is applied to several ubiquitin trimers to demonstrate the effect of linkage type on the solution states of the signaling protein. Here, we observe that the linkage site directly affects the solution flexibility of the trimer and theorize that this difference in plasticity contributes to their disparate roles in vivo.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tilt angle control of nanocolumns grown by glancing angle sputtering at variable argon pressures

We show that the tilt angle of nanostructures obtained by glancing angle sputtering is finely tuned by selecting the adequate argon pressure. At low pressures, a ballistic deposition regime dominates, yielding high directional atoms that form tilted nanocolumns. High pressures lead to a diffusive regime which gives rise to vertical columnar growth. Monte Carlo simulations reproduce the experimental results indicating that the loss of directionality of the sputtered particles in the gas phase, together with the self-shadowing mechanism at the surface, are the main processes responsible for the development of the columns.

36 MATERIALS SCIENCE↗

Thermal performance simulation of a solar cavity receiver under windy conditions

Solar cavity receiver plays a dominant role in the light-heat conversion. Its performance can directly affect the efficiency of the whole power generation system. A combined calculation method for evaluating the thermal performance of the solar cavity receiver is raised in this paper. This method couples the Monte-Carlo method, the correlations of the flow boiling heat transfer, and the calculation of air flow field. And this method can ultimately figure out the surface heat flux inside the cavity, the wall temperature of the boiling tubes, and the heat loss of the solar receiver with an iterative solution. With this method, the thermal performance of a solar cavity receiver, a saturated steam receiver, is simulated under different wind environments. The highest wall temperature of the boiling tubes is about 150 C higher than the water saturation temperature. And it appears in the upper middle parts of the absorbing panels. Changing the wind angle or velocity can obviously affect the air velocity inside the receiver. The air velocity reaches the maximum value when the wind comes from the side of the receiver (flow angle {alpha} = 90 ). The heat loss of the solar cavity receiver also reaches a maximum for the side-on wind. (author)

14 SOLAR ENERGY↗

Monte Carlo modeling of electron density in hypersonic rarefied gas flows

The electron density distribution around a vehicle employed in the RAM-C II flight test is calculated with the DSMC method. To resolve the mole fraction of electrons which is several orders lower than those of the primary species in the free stream, an algorithm named as trace species separation (TSS) is utilized. The TSS algorithm solves the primary and trace species separately, which is similar to the DSMC overlay techniques; however it generates new simulated molecules of trace species, such as ions and electrons in each cell, basing on the ionization and recombination rates directly, which differs from the DSMC overlay techniques based on probabilistic models. The electron density distributions computed by TSS agree well with the flight data measured in the RAM-C II test along a decent trajectory at three altitudes 81km, 76km, and 71km.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo calculations of k{sub Q}, the beam quality conversion factor

Purpose: To use EGSnrc Monte Carlo simulations to directly calculate beam quality conversion factors, k{sub Q}, for 32 cylindrical ionization chambers over a range of beam qualities and to quantify the effect of systematic uncertainties on Monte Carlo calculations of k{sub Q}. These factors are required to use the TG-51 or TRS-398 clinical dosimetry protocols for calibrating external radiotherapy beams. Methods: Ionization chambers are modeled either from blueprints or manufacturers' user's manuals. The dose-to-air in the chamber is calculated using the EGSnrc user-code egs{sub c}hamber using 11 different tabulated clinical photon spectra for the incident beams. The dose to a small volume of water is also calculated in the absence of the chamber at the midpoint of the chamber on its central axis. Using a simple equation, k{sub Q} is calculated from these quantities under the assumption that W/e is constant with energy and compared to TG-51 protocol and measured values. Results: Polynomial fits to the Monte Carlo calculated k{sub Q} factors as a function of beam quality expressed as %dd(10){sub x} and TPR{sub 10}{sup 20} are given for each ionization chamber. Differences are explained between Monte Carlo calculated values and values from the TG-51 protocol or calculated using the computer program used for TG-51 calculations. Systematic uncertainties in calculated k{sub Q} values are analyzed and amount to a maximum of one standard deviation uncertainty of 0.99% if one assumes that photon cross-section uncertainties are uncorrelated and 0.63% if they are assumed correlated. The largest components of the uncertainty are the constancy of W/e and the uncertainty in the cross-section for photons in water. Conclusions: It is now possible to calculate k{sub Q} directly using Monte Carlo simulations. Monte Carlo calculations for most ionization chambers give results which are comparable to TG-51 values. Discrepancies can be explained using individual Monte Carlo calculations of various correction factors which are more accurate than previously used values. For small ionization chambers with central electrodes composed of high-Z materials, the effect of the central electrode is much larger than that for the aluminum electrodes in Farmer chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗