Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed wind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Simulating Impacts of Extreme Events on Grids with High Penetrations of Wind Power Resources

As extreme weather events become more frequent and intense, the demand for connecting grid operation and infrastructure planning with extreme event models will increase as well. We present a methodology for creating damage contingencies and scenarios for electric transmission grids during a hurricane strike. Using WIND Toolkit meteorological data in conjunction with fragility curves for various electric grid elements, we generate stochastic damage scenarios that can be used for short- and long-term planning problems, e.g., emergency asset management. Included is an example case study: Hurricane Dolly damaging a synthetic 2000-bus test system during its landing in Southern Texas. We perform statistical analysis of damages and discuss topological effects on the example synthetic grid. Also, we include a cursory evaluation of impacts using simplified operational models. Finally, we discuss how our method can be extended to use even higher-fidelity meteorological data sets and suggest directions for future work.

contingencies↗

Thoughts and Hypotheses on the Metrics and Needs for the Stability of Highly Inverter-Based Island Systems

As levels of wind, photovoltaics (PVs), and battery energy storage on power systems rise, it is useful to be able to quickly compare how much generation (instantaneous power and annual energy) comes from these inverter-based resources (IBRs). A commonly used metric is the percentage of inverter-based generation (% IBR) in a dispatch scenario (as a percentage of the total generation or total load), which can be useful for estimating when certain operational challenges arise (high rates of change of frequency, underdamped control interactions, low system strength, low fault current availability, and so on). Another similar and commonly used metric pioneered on the relatively large island of Ireland, system nonsynchronous penetration (SNSP), is similar to the % IBR and is subject to similar limitations. SNSP has the advantage of handling high-voltage dc in a defined way.

fault currents↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Forecasting for the Weather Driven Energy System - A New Task under IEA Wind

The energy system needs a range of forecast types for its operation in addition to the narrow wind power forecast that has been the focus of considerable recent attention. Therefore, the group behind the former IEA Wind Task 36 Forecasting for Wind Energy has initiated a new IEA Wind Task with a much broader perspective, which includes prospective interaction with other IEA Technology Collaboration Programmes such as the ones for PV, hydropower, system integration, hydrogen etc. In the new IEA Wind Task 51 (entitled "Foreacsting for the Weather Drive Energy System") the existing Work Packages (WPs) are complemented by work streams in a matrix structure. The Task is divided in three WPs according to the stakeholders: WP1 is mainly aimed at meteorologists, providing the weather forecast basis for the power forecasts. In WP2, the forecast service vendors are the main stakeholders, while the end users populate WP3. The new Task 51 started in January 2022. Planned activities include 4 workshops. The first will focus on the state of the art in forecasting for the energy system plus related research issues and be held during September 2022 in Dublin. The other three workshops will be held later during the 4-year Task period and address (1) seasonal forecasting with emphasis on Dunkelflaute, storage and hydro, (2) minute-scale forecasting, and (3) extreme power system events. The issues and conclusions of each of the workshops will be documented by a published paper. Additionally, the Recommended Practice on Forecast Solution Selection will be updated to reflect the broader perspective.

geophysics computing↗

Foundations for the Future Power System: Inverter-Based Resource Interconnection Standards

As power systems evolve to become reliant on solar, wind, batteries, and other inverter-based resources (IBRs), it is essential that those resources meet certain minimum performance and capability criteria designed to ensure the power system operates stably and reliably. Because those criteria, as enshrined in interconnection standards, take years to develop and are very long lived, they need to account for not only the present state of the power system but also its expected future state over the lifetime of the power plants to which they will apply. In addition, they need to be specific enough to ensure reliability without over specifying and, thereby, impeding innovation. Because power systems are shifting rapidly from a state where IBRs make up a small to medium portion of generation to one where the generation will, at times, come predominantly from IBRs, interconnection standards are especially challenging to develop today. Good interconnection standards can make the power system more reliable and less costly to operate, whereas poorly designed standards can lead to major problems, like the famous German 50.2-Hz problem, which introduced a risk of losing many gigawatts of solar on a frequency excursion and resulted in many IBRs being retrofitted at great cost to mitigate a major system reliability risk. Readying the power system by specifying forward-looking technical minimum functional capabilities for IBRs can be an effective approach to avoid future retrofits.

data models↗

The temperature of quiescent streamers during solar cycles 23 and 24

Recent in-situ determinations of the temporal evolution of the charge state distribution in the fast and slow solar wind have shown a general decrease in the degree of ionization of all the elements in the solar wind along solar cycles 23 and 24. Such a decrease has been interpreted as a cooling of the solar corona which occurred during the decline and minimum phase of solar cycle 23 from 2000 to 2010. In the present work, we investigate whether spectroscopic determinations of the temperature of the quiescent streamers show signatures of coronal plasma cooling during cycles 23 and 24. We measure the coronal electron density and thermal structure at the base of 60 quiescent streamers observed from 1996 to 2013 by SOHO/SUMER and Hinode/EIS and find that both quantities do now show any significant dependence on the solar cycle. We argue that if the slow solar wind is accelerated from the solar photosphere or chromosphere, the measured decrease in the in-situ wind charge state distribution might be due to an increased efficiency in the wind acceleration mechanism at low altitudes. If the slow wind originates from the corona, a combination of density and wind acceleration changes may be responsible for the in-situ results.

79 ASTRONOMY AND ASTROPHYSICS↗

U.S. Department of Energy Competitiveness Improvement Project (CIP) 2024 Small Turbine Certification and/or Listing Awardee: Sonsight Wind

This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by Sonsight Wind for Small Turbine Certification and/or Listing. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NREL on behalf of DOE's Wind Energy Technologies Office, CIP helps advance wind energy as a cost-effective, distributed generation technology option.

17 WIND ENERGY↗

U.S. Department of Energy Competitiveness Improvement Project (CIP) 2024 Technology Commercialization Awardee: Siva Powers America Inc.

This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by Siva Powers America Inc. for a Technology Commercialization Award. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NREL on behalf of DOE's Wind Energy Technologies Office, CIP helps advance wind energy as a cost-effective, distributed generation technology option.

17 WIND ENERGY↗

U.S. Department of Energy Competitiveness Improvement Project (CIP) 2024 Manufacturing Process Innovation Awardee: Bergey Windpower Co.

This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by Bergey Windpower Co. for manufacturing process innovation. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NREL on behalf of DOE's Wind Energy Technologies Office, CIP helps advance wind energy as a cost-effective, distributed generation technology option.

17 WIND ENERGY↗

U.S. Department of Energy Competitiveness Improvement Project (CIP) 2024 Component Innovation Awardee: Windurance LLC

This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by Windurance LLC for component innovation. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NREL on behalf of DOE's Wind Energy Technologies Office, CIP helps advance wind energy as a cost-effective, distributed generation technology option.

17 WIND ENERGY↗

U.S. Department of Energy Competitiveness Improvement Project (CIP) 2024 Small Turbine Certification and/or Listing Awardee: NPS Solutions LLC

This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by NPS Solutions LLC for Small Turbine Certification and/or Listing. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NREL on behalf of DOE's Wind Energy Technologies Office, CIP helps advance wind energy as a cost-effective, distributed generation technology option.

17 WIND ENERGY↗

U.S. Department of Energy Competitiveness Improvement Project (CIP) 2024 Small Turbine Certification and Listing Awardee: Uprise Energy

This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by Uprise Energy for small turbine certification and listing. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NREL on behalf of DOE's Wind Energy Technologies Office, CIP helps advance wind energy as a cost-effective, distributed generation technology option.

17 WIND ENERGY↗

U.S. Department of Energy Competitiveness Improvement Project (CIP) 2024 Technology Commercialization Awardee: EWT Americas Inc.

This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by EWT Americas, Inc., for technology commercialization. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NREL on behalf of DOE's Wind Energy Technologies Office, CIP helps advance wind energy as a cost-effective, distributed generation technology option.

17 WIND ENERGY↗

Dynamic performance analysis of two regional Nuclear Hybrid Energy Systems

In support of more efficient utilization of clean energy generation sources, including renewable and nuclear options, hybrid energy systems (HES) can be designed and operated as flexible energy resources (FER) to meet both electrical and thermal energy needs in the electric grid and industrial sectors. These conceptual systems could effectively and economically be utilized, for example, to manage the increasing levels of dynamic variability and uncertainty introduced by variable energy resources (VER) such as renewable sources (e.g., wind, solar), distributed energy resources, demand response schemes, and modern energy demands (e.g., electric vehicles) with their ever changing usage patterns. HES typically integrate multiple energy inputs (e.g., nuclear and renewable generation) and multiple energy outputs (e.g., electricity, gasoline, fresh water) using complementary energy conversion processes. This work reports a preliminary dynamic analysis of two realistic HES including a nuclear reactor as the main baseload heat generator and to assess the local (e.g., HES owners) and system (e.g., the electric grid) benefits attainable by their application in scenarios with multiple commodity production and high renewable penetration. It is performed for regional cases - not generic examples - based on available resources, existing infrastructure, and markets within the selected regions. This study also briefly addresses the computational capabilities developed to conduct such analyses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying Progress Across Different CMIP Phases With the ESMValTool

Abstract More than 40 model groups worldwide are participating in the Coupled Model Intercomparison Project Phase 6 (CMIP6), providing a new and rich source of information to better understand past, present, and future climate change. Here, we use the Earth System Model Evaluation Tool (ESMValTool) to assess the performance of the CMIP6 ensemble compared to the previous generations CMIP3 and CMIP5. While CMIP5 models did not capture the observed pause in the increase in global mean surface temperature between 1998 and 2013, the historical CMIP6 simulations agree well with the observed recent temperature increase, but some models have difficulties in reproducing the observed global mean surface temperature record of the second half of the twentieth century. While systematic biases in annual mean surface temperature and precipitation remain in the CMIP6 multimodel mean, individual models and high‐resolution versions of the models show significant reductions in many long‐standing biases. Some improvements are also found in the vertical temperature, water vapor, and zonal wind speed distributions, and root‐mean‐square errors for selected fields are generally smaller with reduced intermodel spread and higher average skill in the correlation patterns relative to observations. An emerging property of the CMIP6 ensemble is a higher effective climate sensitivity with an increased range between 2.3 and 5.6 K. A possible reason for this increase in some models is improvements in cloud representation resulting in stronger shortwave cloud feedbacks than in their predecessor versions.

Bock, L.↗

Blowing Snow at McMurdo Station, Antarctica During the AWARE Field Campaign: Surface and Ceilometer Observations

Blowing snow (BLSN) is an impactful process in cold climates, affecting regional thermodynamics, radiation properties, and the surface mass balance of snow. Though it has significant climatic impacts, the process is still poorly understood and not widely included in weather and climate models. In 2016, the AWARE Field Campaign saw the deployment of a large suite of in situ and remote sensing instruments to McMurdo Station, Antarctica allowing for investigation of BLSN. A ceilometer–based BLSN detection algorithm used elsewhere in Antarctica is applied to data from AWARE, yielding a BLSN frequency of 14.1% compared to 8.2% as detected by human observers. To increase confidence in detections, the algorithm is updated to have shorter temporal averaging and to include a variety of meteorological thresholds to limit false detections due to fog. Efforts to incorporate a laser disdrometer into the algorithm were unsuccessful. An unphysical dependence of particle size distributions on wind speed is found suggesting observations are problematic at wind speeds greater than 10 m s –1 . The revised algorithm detected a BLSN frequency of 7.4%, increasing agreement with human observations and confidence that the process is actively occurring at the observation site. Furthermore, these observations are put into context of a climatology of human observations of BLSN at McMurdo station from 2002–2018. An annual average of 8.0%–14.0% is estimated, with a total annual range of 3.4%–21.3%. Regardless of whether BLSN is observed by humans or instrument, the majority of cases at this location are associated with ongoing precipitation.

54 ENVIRONMENTAL SCIENCES↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Adaptive Narrowband Damping for Improving Harmonic Stability of Modular Multilevel Converter

Harmonic instability events between modular multilevel converter (MMC) and ac systems have been widely reported in recent years. To damp harmonic resonance, this paper proposes an adaptive narrowband damping control that automatically programs, adds, and adjusts the damping around the oscillation frequency when an oscillation is detected. First, the paper presents a low-pass filter design for MMC control loops that pushes all negative damping of the MMC impedance down to the medium-frequency range (< ~ 1000 Hz). Then, an adaptive damping control that uses online oscillation detection is proposed, which can automatically configure the narrowband damper to provide positive damping to the MMC around the detected oscillation frequency. In contrast to existing narrowband damping methods, the proposed adaptive narrowband damper dynamically adjusts the damping gain and the width of the damping range based on continuous monitoring of system resonance conditions (e.g., adjust damping gain to zero when the system resonance disappears). Electromagnetic transient simulation results validate the efficacy of the proposed method in two typical MMC-based power systems.

active damping↗