Search NASA⌕ Search

SEARCH · Search NASA

Results for “distribution system operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

2 Kelvin helium distribution system for the Electron Ion Collider’s 10 o’clock satellite refrigerator

The Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) will involve superfluid helium cooling of superconducting magnets and Superconducting Radio Frequency (SRF) cavities at several sites around the existing Relativistic Heavy Ion Collider (RHIC) accelerator tunnel. While the majority of the cooling power for these loads is provided by BNL’s central cryogenic plant, Jefferson Lab is designing satellite equipment which augments the central plant and enables 2 Kelvin operation. The 2 K cryogenic distribution system for the collider’s 10 o’clock location (Interaction Region 10 or IR10) includes all necessary interfaces to the IR10 Satellite Refrigerator, to the overall EIC cryogenic distribution system, and to 12 SRF cryomodules for the electron and hadron storage rings. In addition to providing the required cooling capacities in all operating modes, the IR10 2 K cryogenic distribution system also stabilizes the supply temperature and enables safe connection and disconnection of individual IR10 cryomodules. Moreover, the layout of the IR10 2 K cryogenic distribution system copes with challenging spatial constraints and adapts to the process configuration and routing of existing RHIC cryogenic distribution components which will be re-used for EIC. This paper gives a full overview of the IR10 satellite cryogenic distribution system design, and highlights some of the challenges encountered.

Laverdure, Nathaniel [Thomas Jefferson National Ac↗

Resilience-Motivated Distribution System Restoration Considering Electricity-Water-Gas Interdependency

A major outage in the electricity distribution system may affect the operation of water and natural gas supply systems, leading to an interruption of multiple services to critical customers. Therefore, enhancing resilience of critical infrastructures requires joint efforts of multiple sectors. In this paper, a distribution system service restoration method considering the electricity-water-gas interdependency is proposed. The objective is maximizing the supply of electricity, water, and gas to critical customers after an extreme event. The operational constraints of electricity, water, and natural gas networks are considered. Additionally, the characteristics of electricity-driven coupling components, including water pumps and gas compressors, are also modeled. Relaxation techniques are applied to non convex constraints posed by physical laws of those networks. Consequently, the restoration problem is formulated as a mixed-integer second-order cone program, which can readily be solved by the off-the-shelf solvers. The proposed method is validated by numerical simulations on an electricity-water-gas integrated system, developed based on benchmark models of the subsystems. The results indicate that considering the interdependency refines the allocation of limited generation resources and demonstrate the exactness of the proposed convex relaxation

24 POWER TRANSMISSION AND DISTRIBUTION↗

Battery Energy Storage Scheduling for Optimal Load Variance Minimization

Generation portfolio can be significantly altered due to the deployment of distributed energy resources (DER) in distribution networks and the concept of microgrid. Generally,distribution networks can operate in a more resilient and economic fashion through proper coordination of DER. However, due to the partially uncontrollable and stochastic nature of some DER, the variance of net load of distribution systems increases, which raises the operational cost and complicates operation for transmission companies. This motivates peak shaving and valley filling using energy storage units deployed in distribution systems. This paper aims at theoretical formulation of optimal load variance minimization, where the infinity norm of net load is minimized. Then, the problem is reformulated equivalently as a linear program. A case study is performed with capacity limited battery energy storage model and the simplified power flow model of a radial distribution network. The influence of capacity limit and deployment location are studied.

Melin, Alexander↗

Unleash Values From Grid-Edge Flexibility: An Overview, Experience, and Vision for Leveraging Grid-Edge Distributed Energy Resources to Improve Grid Operations

The power system landscape is presently undergoing a dramatic change with the rapid integration of numerous distributed energy resources (DERs) at the grid edge. Broadly, we consider grid-edge DERs as any electricity source, storage, and demand response program connected to the medium-to-low-voltage distribution system.

distributed energy resource↗

PV System Component Fault and Failure Compilation and Analysis.

This report describes data collection and analysis of solar photovoltaic (PV) equipment events, which consist of faults and fa ilures that occur during the normal operation of a distributed PV system or PV power plant. We present summary statistics from locations w here maintenance data is being collected at various intervals, as well as reliability statistics gathered from that da ta, consisting of fault/failure distributions and repair distributions for a wide range of PV equipment types.

14 SOLAR ENERGY↗

Robust Distributed State Estimator for Interconnected Transmission and Distribution Networks (Final Report RPPR-1)

This project’s objective is to develop a combined transmission and distribution state estimator which accounts for very large system size and model complexity (by way of distributing the computations) and large number of solar PV units connected to the distribution system on multiple feeders. The project not only provides a robust formulation and solution to this problem but also tests the solution by implementing it on a well-established large utility system. It introduces several improvements with respect to the state of the art in existing state estimation software: (a) The developed state estimator (SE) allows robust and accurate monitoring of bidirectional flows in distribution systems which result due to the distributed energy sources which are not observable and thus not incorporated in generation dispatch; (b) Large utility systems with tens of thousands of transmission buses and hundreds of thousands of distribution nodes are difficult to model as a single integrated system. This shortcoming is addressed by developing a “scalable distributed computational framework” which allows splitting the ultra large system models into several small subsystems and coordinating their solution by a robust and practical state estimation formulation; (c) Measurement errors irrespective of their locations are detected and removed by the developed state estimator. Historically, transmission and distribution systems were analyzed and operated as two independent systems. Given the non-transposed short feeder sections, unevenly loaded phases, strictly radial configuration and unidirectional power flows in the absence of remote generation, distribution system analysis was customized to account for these characteristics. However, some of these assumptions are no longer valid (non-radial configuration, bidirectional power flows) and thus distribution system analysis should be revisited. Furthermore, in the past, the interaction between the transmission and distribution systems was quite passive, where distribution substations were modeled as lumped loads in the transmission system model. With substantial generation injected by renewable generation located in the distribution systems, such modeling will no longer be accurate. The developed state estimator facilitates proper monitoring of the interactions between the transmission and distribution systems and enables smart dispatch of these units which are made observable by the state estimator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of Wind Power and Load Forecasting Error Distributions: Preprint

The introduction of large amounts of variable and uncertain power sources, such as wind power, into the electricity grid presents a number of challenges for system operations. One issue involves the uncertainty associated with scheduling power that wind will supply in future timeframes. However, this is not an entirely new challenge; load is also variable and uncertain, and is strongly influencedby weather patterns. In this work we make a comparison between the day-ahead forecasting errors encountered in wind power forecasting and load forecasting. The study examines the distribution of errors from operational forecasting systems in two different Independent System Operator (ISO) regions for both wind power and load forecasts at the day-ahead timeframe. The day-ahead timescale iscritical in power system operations because it serves the unit commitment function for slow-starting conventional generators.

17 WIND ENERGY↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids With Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Though individual consumers are interconnected at the low-voltage distribution system, these resources are typically modeled as variables at the transmission network level. Demand-side participation cannot be leveraged effectively without explicitly including the distribution system dynamics in the optimization-based wholesale market operations. This project grew from a vision for co-optimized interaction of distribution systems, or microgrids, with the high-voltage transmission system. In this framework, microgrids encompass consumers, distributed renewables and storage. The energy management system of the lower voltage system (distribution or microgrid) can also sell (buy) excess (necessary) energy from the transmission system. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. An ideal microgrid is defined as an electric entity capable of operating in both interconnected (with the high-voltage grid) and islanded mode. As such, the microgrid should incorporate generating units (traditional units and intermittent) and if needed, exchange power with the high-voltage grid. The interplay between the microgrid and high-voltage grid motivated the development of the co-optimization approach to ensure efficient performance of the interconnected network. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Citadels Final Report (GMLC 2.2.1: Citadels)

This is the final project report for the Grid Modernization Laboratory Consortium (GMLC) Resilient Distribution System (RDS) Citadels project. The primary goal of this GMLC project was to increase the operational flexibly of power systems by engaging microgrids distributedly, coordinated using consensus algorithms. The primary goal was successfully achieved. The primary goal was divided into three areas: Implement peer-to-peer control between microgrid controllers using the Open Field Message Bus (OpenFMB) approach; Develop and implement consensus algorithms on commercially available hardware that allows a group of microgrids to distributedly implement operational controls; Develop the architectures and controls to enable groups of microgrids to coordinate their operations to support the bulk power system during abnormal events, and end-use loads in the event the bulk power systems fail.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Power Scheduling for a Medium Voltage AC/DC Hybrid Distribution Network

With the great increase of renewable generation as well as the DC loads in the distribution network; DC distribution technology is receiving more attention; since the DC distribution network can improve operating efficiency and power quality by reducing the energy conversion stages. This paper presents a new architecture for the medium voltage AC/DC hybrid distribution network; where the AC and DC subgrids are looped by normally closed AC soft open point (ACSOP) and DC soft open point (DCSOP); respectively. The proposed AC/DC hybrid distribution systems contain renewable generation (i.e., wind power and photovoltaic (PV) generation); energy storage systems (ESSs); soft open points (SOPs); and both AC and DC flexible demands. An energy management strategy for the hybrid system is presented based on the dynamic optimal power flow (DOPF) method. The main objective of the proposed power scheduling strategy is to minimize the operating cost and reduce the curtailment of renewable generation while meeting operational and technical constraints. The proposed approach is verified in five scenarios. The five scenarios are classified as pure AC system; hybrid AC/DC system; hybrid system with interlinking converter; hybrid system with DC flexible demand; and hybrid system with SOPs. Results show that the proposed scheduling method can successfully dispatch the controllable elements; and that the presented architecture for the AC/DC hybrid distribution system is beneficial for reducing operating cost and renewable generation curtailment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LCLS-II Cryomodule and Cryogenic Distribution Control

LCLS-II is a superconducting upgrade to the existing Linear Coherent Light Source at the SLAC National Accelerator Laboratory. Construction is underway with a planned continuous wave beam rate of up to 1 MHz. Two cryogenic plants provide helium to a distribution system, and 37 cryomodules with superconducting cavities will operate with Liquid helium at 2.2K. The cryomodules and distribution system is controlled with networked PLC's and EPICS as an integrated system that work in concert for controlling valves, pressure, flow, and temperature. Interlocks and critical process information is communicated with the Low Level Radio Frequency, vacuum, and magnet systems. Engaging the controls community proved vital in advancing the controls architecture from a conventional design to a centralized, reliable, and cost-effective distributed platform.

43 PARTICLE ACCELERATORS↗

Cybersecurity Guidance for Distributed Energy Resource Management Systems (DERMS)

As part of the Securing Solar for the Grid (S2G): Cybersecurity for Solar Systems workshop at RE + in Las Vegas, Nevada, NREL researchers discuss an ongoing effort to develop cybersecurity guidance for vendors and operators of distributed energy resource management systems (DERMS). This guide will prioritize cybersecurity best practices that can be testing and developed for a potential future standard. This presentation will highlight NREL's ongoing work in this area and future areas of research.

cyber↗

Evaluating Network Performance of Containerized Test Framework for Distributed Space Systems

Distributed space systems are a mission architecture consisting of multiple spacecraft as a cohesive system which provide multipoint sampling, increased mission coverage, or improved sample resolution, while reducing mission risk through redundancy. To fully realize the potential of these systems, eventually scaling to hundreds or thousands of spacecraft, distributed space systems need to be operated as a single entity, which will enable a variety of novel scientific space missions. The Distributed Spacecraft Autonomy (DSA) project is a software project which aims to mature the technology needed for those systems, namely autonomous decision-making and swarm networking. The DSA project leverages a containerized swarm test framework to simulate spacecraft software, which can identify emergent behavior early in development. Container virtualization allows distributed spacecraft systems to be simulated entirely in software on a single computer, avoiding the overhead associated with conventional approaches like hardware facsimiles and virtual machines. For this approach to be effective, the simulated system behavior must not be artificially influenced by the swarm test framework itself. To address this, we present a series of benchmarks to quantify virtual network bandwidth available on a single-host computer and contextualize this against the network and application behavior of the DSA swarm test framework.

Distributed Spacecraft Autonomy↗

Methods, media and systems for managing a distributed application running in a plurality of digital processing devices

Methods, media and systems for managing a distributed application running in a plurality of digital processing devices are provided. In some embodiments, a method includes running one or more processes associated with the distributed application in virtualized operating system environments on a plurality of digital processing devices, suspending the one or more processes, and saving network state information relating to network connections among the one or more processes. The method further include storing process information relating to the one or more processes, recreating the network connections using the saved network state information, and restarting the one or more processes using the stored process information.

97 MATHEMATICS AND COMPUTING↗

Digital twin advanced distribution management systems (ADMS) and methods

Advanced Distribution Management Systems not generally optimize over the entire feeder because there are few high-fidelity distribution circuit models and real-time distribution-connected sensors are rare. The limited observability at the distribution level makes it difficult to globally optimize distribution operations and issue control setpoints to power systems equipment or Distributed Energy Resources (DER) to perform grid-support services. For example, setpoints can be issued to DER based on results from an optimization module that incorporates a static or time-series feeder simulation. Feeder simulation initial conditions are populated with photovoltaic (PV) and load forecasts, state estimation results, and/or digital twin measurements or state output. The real-time (RT) digital twin runs a model of the feeder to generate state estimation pseudo-measurements since there are limited live feeder measurements.

Johnson, Jay Tillay↗

Addendum to Third Supplemental Cultural Resources Review for the Infrastructure Cleanup on ALE, Hanford Site, HCRC# 2008-600-004D: Documentation of No Adverse Effect from Filling Two Cisterns at the National Register-Eligible Archaeological Site 45BN01032

The Third Supplemental Cultural Resources Review for the Infrastructure Cleanup on the Fitzner/Eberhardt Arid Lands Ecology Reserve, 600 Area, Hanford Site, Benton County, Washington, HCRC#2008-600-004D completed by the Pacific Northwest National Laboratory (PNNL) Cultural Resources Project (CRP) for the U.S. Department of Energy, Richland Operations Office (DOE-RL) identified a National Register-eligible archaeological site 45BN01032, the historic Rattlesnake Hills Gas Field Compressor Station. The compressor station was the core of the Rattlesnake Hills Field gas distribution system which was in operation from 1929 until 1941. Within the industrial component of this site are two large rectangular concrete cisterns that were used for water storage, both located on the southeastern boundary of the site.The original remediation proposed by DOE-RL at this site was to remove t-posts, placed around both cisterns at some point after the gas field was abandoned. This undertaking was addressed in the Third Supplemental Cultural Resources Review for the Infrastructure Cleanup on the Fitzner/Eberhardt Arid Lands Ecology Reserve, 600 Area, Hanford Site, Benton County, Washington, HCRC#2008-600-004D where a recommendation of no adverse effect to 45BN01032 was made because the t-posts are not contributing components of the site. Subsequent to the initial finding of No Adverse Effect, DOE-RL now proposes to fill these two cisterns with basalt rubble for health and safety reasons. This document outlines measures that will allow the two cisterns to be filled with no adverse effects to site 45BN01032.

Arid Lands Ecology Reserve↗

Stochastic pre-event preparation for enhancing resilience of distribution systems

Extreme weather events are the common causes for power supply interruptions and power outages in electrical distribution systems. Improving the distribution system and enhancing its resilience is becoming crucial due to the increased frequency of extreme weather events. Preparation and allocation of multiple flexible resources, such as mobile resources, fuel resources, and labor resources before extreme weather events can mitigate the effects of extreme weather events and enhance the resilience of power distribution systems. Here, in this paper, a two-stage stochastic mixed-integer linear programming (SMILP) is proposed to optimize the preparation and resource allocation process for upcoming extreme weather events, which leads to faster and more efficient post-event restoration. The objective of the proposed two-stage SMILP is to maximize the served load and minimize the operating cost of flexible resources. The first stage in the optimization problem selects the amounts and locations of different resources. The second stage considers the operational constraints of the distribution system and repair crew scheduling constraints. The proposed stochastic pre-event preparation model is solved by a scenario decomposition method, Progressive Hedging (PH), to ease the computational complexity introduced by a large number of scenarios. Furthermore, to show the impact of solar photovoltaic (PV) generation on system resilience, three types of PV systems are considered during a power outage and the resilience improvements with different PV penetration levels are compared. Numerical results from simulations on a large-scale (more than 10,000 nodes) distribution feeder have been used to validate the effectiveness and scalability of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reinforcement Learning‐Based Adaptation of Grid Following Inverter's Internal Controller to Networked Microgrids' Strengths

The varying topological configurations, generator commitments and dispatches, and dynamic load demand lead to changing system's strengths during the operations of networked microgrids. When the system's strengths significantly change, the fixed control gains at large devices may result in unsatisfactory system performance; this necessitates the tuning of the control gains at large devices to adapt to the changing system's strengths. In this paper, observer-based reinforcement learning (RL) is utilised to automatically tune the proportional-integral (PI) gains of phase lock loop (PLL) controller of grid-following (GFL) inverters to adapt to the changing strengths of microgrids and networked microgrids. The RL agent in this framework augments an observer predicting system's strengths, from which the RL control policy will adjust accordingly to tune the PLL controller's gains towards the system's strengths. Also, to enhance the control performance, the recently introduced Barrier function-based RL framework is leveraged for the design of reward function to prevent the high frequency nadir. An operational 26 kV electric distribution system, which is modelled as networked microgrids, is used to illustrate the need and effectiveness of the proposed RL-tuned control.

frequency response↗