Search NASA⌕ Search

SEARCH · Search NASA

Results for “distribution system optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Performance and Durability of Hybrid Fuel Cell Systems for Class-8 Long Haul Trucks

Hybrid fuel cell-battery configurations are investigated that overcome thermal management issues in fuel cell powertrains for heavy-duty Class 8 trucks. The battery is sized so that it has sufficient capacity to provide supplemental power and energy on a hill climb transient at end-of-life. A dynamic load sharing strategy is developed to distribute the power demand between the fuel cell system (FCS) and the energy storage system in a manner that optimizes their lifetimes. The FCS end-of-life is identified as the terminal point beyond which the stack cannot generate the rated power with target power density at 0.7 V and 40 °C ambient temperature. Reaching the target lifetime with a-Pt/C cathode catalyst in one hybrid configuration requires voltage clipping to 813 mV, idle power limited to 50 kW, catalyst overloading to 0.45 mg cm -2 total Pt in anode and cathode, and 44% active membrane area oversizing. The stack and FCS drive cycle efficiencies decrease by 4.2% and 5.4%, respectively, during the electrode lifetime. Further, the FCS performance, durability and cost are compared with the targets of 68% peak efficiency, 0.30 mg cm -2 total Pt loading, 2.5 kW/g PGM Pt group metal (PGM) loading, 750 mW cm -2 power density, 25,000-h lifetime and $80/kW cost.

33 ADVANCED PROPULSION SYSTEMS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A General Method for Estimating Zonal Transmission Interface Limits from Nodal Network Data: Preprint

Capacity expansion models for the electric power system often employ zonal (rather than nodal) resolution, necessitating estimates of aggregate power transfer limits across the interfaces between model zones. Interface limits between planning areas are sometimes published, but they are not generalizable to arbitrary zone shapes. There is thus a need for a reproducible method for estimating interface transfer limits (ITLs) between user-defined zones directly from nodal transmission system data. Here, we present a simple method for estimating ITLs using a DC power flow approximation via the power transfer distribution factor (PTDF) matrix. Linear optimization is performed to identify the distribution of power flows that maximizes the total flow on interface-crossing lines, subject to individual line ratings, limits on bus injection/withdrawal, and the relationships among flows, injections, and withdrawals imposed by the PTDF matrix. We demonstrate the application of the method on a 134-zone ~65000-bus system, and we explore the influence of flow direction, contingency level, and zone size on the estimated ITLs. There is significant heterogeneity in the ratio of the ITL to the sum of interface-crossing line ratings, which highlights the importance of accounting for the physical constraints on power flows imposed by Kirchhoff's laws when estimating zonal ITLs.

17 WIND ENERGY↗

Uncertainty quantification of a physics-informed model based on sparse identification of a Thermal Energy Distribution System

Integrated energy systems (IES)s are crucial for enhancing the economy and efficiency of power generation sources (e.g., nuclear energy) necessary to unleash American energy dominance. These systems can be integrated with thermal energy storage (TES) and intermittent renewable energies to optimize overall energy use, peak-load regulation, and demand-side responses. However, the stabilization of energy generation, transport, and utilization introduces operational complexities that exceed the challenges of managing each sub-component individually. Currently, though IESs rely on human operators for efficiency and stability, reducing human error risk and enhancing performance through automation is highly desirable. Recent advances at Idaho National Laboratory have demonstrated successful control of the Thermal Energy Distributed System (TEDS). However, the automatic control system depends on a deterministic Sparse Identification of Nonlinear Dynamics with Control (SINDyC) model, which are trained based on simulation data from physics-based simulations. Because of uncertainties in physics-based simulation, SINDyC model results in large discrepancies against experimental data and cannot be reliably used in automatic control. In this paper, we present an innovative approach to address these discrepancies by quantifying uncertainties and developing a more robust model. We first generated trajectories by using first-principles physics codes to encapsulate the experiment. Next, we trained thousands of models by randomly sampling these trajectories. We then collapsed all those models into one probabilistic SINDyC by fitting a multivariate Gaussian distribution onto the resulting coefficient’s distribution. Despite its simplicity, our approach successfully produced 95% confidence intervals that captured the experimental trajectories. It even did so with a higher probability and better U-pooling score across six of the seven relevant quantities of interest (QoIs), as compared to other classical approaches. In conclusion, ongoing research is focusing on generating new experimental trajectories to validate this approach, and on employing Bayesian calibration to refine parametric uncertainties and guide future model development efforts.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Tri-level hybrid interval-stochastic optimal scheduling for flexible residential loads under GAN-assisted multiple uncertainties

Various building loads, such as heating, ventilation, and air conditioners (HVACs), electric water heaters (EWHs), and electric vehicles (EVs), can introduce opportunities for improving the flexibility of electricity consumption while satisfying the needs of building owners as well as benefiting the resilience of distribution system. To utilize such flexibility, a tri-level distribution market framework is established, including residential consumers, load aggregators (LAs), and the distribution system operator (DSO). In this work, the uncertainties from all three levels are considered. The random consumption behavior at the consumer level is modeled as a Gaussian noise that is also aggregated and transmitted to the LA level. The weather temperature in the LA level is forecasted as an interval, and the photovoltaic (PV) power in the market-clearing level is modeled by a set of power scenarios generated by Generative Adversarial Networks (GANs). Then, a hybrid interval-stochastic programming is proposed to transform the uncertain problems in the first two levels into deterministic ones. For real-time implementations, a rolling horizon optimization (RHO) scheme is employed to continuously optimize the power consumption based on the latest operating information. Finally, case studies on a modified IEEE 69-bus system validate the effectiveness of the proposed uncertainty modeling strategies and the RHO scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Control Using Stochastic Distribution Control Theory for Intersection Traffic Flow

In this work, we investigated stochastic distribution control theory-based traffic signal optimization to achieve a smooth and uniform flow of vehicles through signalized intersections. In this context, the static and linear dynamic stochastic distribution models were developed to express the relationship between the signal timing and the traffic queue length together with its probability density function. Two stochastic distribution control algorithms were designed to control the signal timing at intersections such that the probability density function of the traffic queue of each intersection road segment is made as narrow and as small as possible. Also, a recursive input-output traffic queue estimation model was proposed, which is data-driven and dynamic in nature, to calculate real-time traffic queue length using traffic signal timings and loop-detector data. The control algorithms were evaluated for a one-signal corridor, two-signal corridor, and 2 x 2 network of signalized intersections. MATLAB simulation examples are provided to demonstrate the use of the proposed algorithms and comparison to the existing widely-used semi-actuated control has been made. Desired results were obtained.

97 MATHEMATICS AND COMPUTING↗

Optimal control to handle variations in moisture content and reactor in-feed rate

The variations in feedstock characteristics, such as moisture and particle size distribution, lead to an inconsistent flow of feedstock from the biomass pre-processing system to the reactor in-feed system. These inconsistencies result in low on-stream times at the reactor in-feed equipment. This research develops an optimal process control method for a biomass pre-processing system comprised of milling and densification operations to provide the consistent flow of feedstock to a reactor's throat. This method uses a mixed-integer optimization model to identify optimal bale sequencing, equipment in-feed rate, and buffer location and size in the biomass pre-processing system. This method, referred to as the hybrid process control (HPC), aims to maximize throughput over time. We compare HPC with a baseline feed forward process control. Our case study based on switchgrass finds that HPC reduces the variation of a reactor's feeding rate by up to 100% without increasing the operating cost of the biomass pre-processing system for biomass with moisture ranging from 10 to 25%. Additionally, HPC reduces the cost of processing biomass by 0.36%–2.22%, and reduces processing time by 0.35%-2.24%. Furthermore, a biorefinery can adapt HPC to achieve its design capacity.

09 BIOMASS FUELS↗

CORE-BFS: Communication-Optimized REctangular-partitioned BFS Achieving 160.845 TeraTEPS on Frontier Supercomputer

Distributed Breadth-First Search (BFS) is fundamental to many large-scale graph applications, but its performance on parallel systems is often limited by high communication overhead. This paper presents CORE-BFS, an extremely scalable GPU-based BFS implementation that introduces a unique rectangular 2D partitioning-based design for Frontier supercomputer. To further improve performance, we propose four key optimizations: (1) Rectangular 2D-partition specific data formats that use two compressed row and one compressed column status array bitmaps combined with a Double Compressed Sparse Row (DCSR) format per partition, reducing memory footprint and inter-rank traffic; (2) Adaptive frontier & communication strategy that unifies top-down and bottom-up traversal on the rectangular layout, uses lazy synchronization in top-down levels, and switches variants based on frontier size to minimize communication overhead; (3) Frontier-split degree-aware update that maps frontier vertices to thread-centric, wavefront-centric, and block-centric kernels based on their degree to improve GPU utilization and memory coalescing; (4) Row-reduction pipeline that overlaps bottom-up adjacency list processing with row-wise bitmap reduction to hide inter-rank latency. Together, these techniques increase parallelism while reducing memory and communication overhead. On the Graph500 benchmark, CORE - BFS scales up to 9,248 Frontier nodes with scale-42 graphs and reaches 160.845 TTEPS, delivering a 5.42 × speedup over our previous Frontier implementation.

Yang, Haoshen [Rutgers University]↗

Real time feedback-based optimization of distributed energy resources

An example device includes a processor configured to receive a plurality of voltage values corresponding to voltage nodes in a first portion of a power system and determine, for each voltage node, a respective value of first and second voltage-constraint coefficients. The processor is also configured to receive a power value corresponding to a connection point of the first portion of the power system with a second portion of the power system and determine for the connection point, a respective value of first and second power-constraint coefficients. The processor is also configured to cause at least one energy resource connected to the first portion of the power system to modify an output power of the at least one energy resource based on the value of the first and second voltage-constraint coefficients for each voltage node and the value of the first and second power-constraint coefficients.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep reinforcement learning assisted co-optimization of Volt-VAR grid service in distribution networks

With the increasing penetration of distributed energy resources in distribution networks, Volt-VAR control and optimization (VVC/VVO) have become very important to ensure an acceptable quality of service to all customers. System operators can rely on slow-responding utility devices, including capacitor banks and on-load tap changing transformers, along with fast-responding battery and photovoltaic (PV) inverters for the VVC/VVO implementation. Because of variations in response time of these two classes of devices, and different control actions (discrete versus continuous), coordinated and optimal scheduling and operation have become of utmost importance. Here, this paper develops a look-ahead deep reinforcement learning (DRL)-based multi-objective VVO technique to improve the voltage profile of active distribution networks, decrease network and inverter power loss, and save the operational cost of the grid. It proposes a deep deterministic policy gradient (DDPG)-based approach to schedule the optimal reactive and/or active power set-points of fast-responding inverters, and a deep Q-network (DQN)-based DRL agent to schedule the discrete decisions variables of slow-responding assets. The reactive power output of PV and battery smart inverters are scheduled at 30-minute intervals and the capacitors’ commitment status is scheduled with several hour intervals. The proposed framework is validated on the modified IEEE 34-bus and 123-bus test cases with embedded PV and PV-plus-storage. To validate the efficacy of the proposed VVO, it is compared with several scenarios, including the base case without VVO, localized droop control of DERs, DDPG-only, and twin delayed DDPG (TD3) agent-based DRL techniques. The results justify the superior performance of the proposed method to improve the voltage profile, reduce network power loss, and minimize the look-ahead grid operational cost while minimizing the undesirable power losses in inverters as a result of power factor adjustments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reinforcement learning for adaptive maintenance policy optimization under imperfect knowledge of the system degradation model and partial observability of system states

Maintenance policy optimization usually is faced with challenges that arise from an imperfect knowledge of system degradation models and from the partial observability of system degradation states. Here, this paper proposes a reinforcement learning method to address these two challenges for a class of maintenance problems with Markov degradation processes. The reinforcement learning approach consists of a learning component and a planning component. Using sequentially collected observations, at each step of decision-making the learning component improves the knowledge of system degradation in terms of the probability distributions of the transition rates based on sequential Bayesian inference. Using the updated transition rates, at each step of decision-making the maintenance policy optimization problem is then formulated as a partially observable Markov decision problem, and the planning component computes the optimal maintenance policy that maximizes the expected cumulative reward. The proposed method is illustrated using a numerical example with repair and inspection maintenance actions. The result shows that as more observations are collected, the learning component progressively learns the true system degradation process, and the planning component adjusts the optimal maintenance policy accordingly as well, which leads to increased reward.

42 ENGINEERING↗

A Trilevel Model for Segmentation of the Power Transmission Grid Cyber Network

Network segmentation of a power grid's communication system can make the grid more resilient to cyberattacks. Here we develop a novel trilevel programming model to optimally segment a grid communication system, taking into account the actions of an information technology (IT) administrator, attacker, and grid operator. The IT administrator is allowed to segment existing networks, and the attacker is given a budget to inflict damage on the grid by attacking the segmented communication system. Finally, the grid operator can redispatch the grid after the attack to minimize damage. The resulting problem is a trilevel interdiction problem that we solve using a branch and bound algorithm for bilevel problems. We demonstrate the benefits of optimal network segmentation through case studies on the 9-bus Western System Coordinating Council (WSCC) system and the 30-bus IEEE system. These examples illustrate that network segmentation can significantly reduce the threat posed by a cyberattacker.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Game Theoretic Orchestration for Cooperation among Power Distribution System Applications

The evolving transformation with the proliferation of distributed energy resources and advanced metering, necessitates advanced distribution systems to integrate and orchestrate a large number of grid-edge devices while also serving multiple system-level objectives such as resilience, decarbonization, equity and other system mandates. The parallel deployment and control of resources towards achieving diverse objectives may lead to conflicts between applications that want to control overlapping sets of device setpoints, potentially leading to oscillatory behavior and suboptimal performance. This work aims at leveraging game theoretic framework to drive cooperative behavior among competitive applications. The work proposes a weighted-consensus based game design to facilitate conflict resolution through consensus-building iterations for modular platform. Simulation-based evaluation on a sample test system demonstrates the performance the proposed deconfliction strategy in resolving operational conflicts and achieving close-to-optimal trade off among the applications. Results also compare the proposed strategy with a distribution optimization approach and illustrate it effectiveness in diverse apps regardless of their design while also incentivizing apps with flexible design.

Advanced distribution operations, cooperation, app↗

Addressing the split incentive challenge for rooftop solar PV and battery energy storage in multifamily rental buildings (CRADA 638 Final Report)

This project advances the understanding of how roof solar PV systems and battery energy storage systems (BESS) can be effectively deployed in multifamily residential buildings, a sector that has historically faced barriers due to misaligned incentives between landlords and tenants. By leveraging high-resolution building stock data and simulation tools, the research demonstrates how energy consumption patterns vary across building types, climates, and occupant characteristics, and how these variations influence the optimal sizing and operation of distributed energy resources. A key contribution is the development of a publicly accessible, web-based tool named RESIDE (Residential Energy Systems & Infrastructure Data Evaluation) that allows users to explore building energy use and evaluate solar and battery configurations without requiring specialized expertise. This significantly lowers the barrier to entry for stakeholders such as property owners, utilities, and policymakers. From a technical perspective, the project shows that integrating rooftop solar PV with battery energy storage can substantially reduce electricity costs and peak demand through strategies such as energy arbitrage and peak shaving. The modeling framework incorporates real-world constraints, including time-of-use electricity pricing and battery degradation, providing realistic and actionable insights. Economically, the results indicate that properly sized systems can deliver meaningful cost savings, improving the feasibility of energy investments in multifamily housing. More broadly, the project benefits the public by supporting the transition to affordable and reliable energy, particularly in rental multifamily housing where adoption has traditionally lagged.

14 SOLAR ENERGY↗

The influence of fire aerosols on surface climate and gross primary production in the Energy Exascale Earth System Model (E3SM)

Fire-emitted aerosols play an important role in influencing Earth’s climate, directly by scattering and absorbing radiation and indirectly by influencing cloud microphysics. The quantification of fire-aerosol interactions, however, remains challenging and subject to uncertainties in emissions, plume parameterizations, and aerosol properties. Here we optimized fire-associated aerosol emissions in the Energy Exascale Earth System Model (E3SM) using the Global Fire Emissions Database (GFED) and AERONET aerosol optical depth (AOD) observations during 1997-2016. Furthermore, we distributed fire emissions vertically using smoke plume heights from Multi-angle Imaging SpectroRadiometer (MISR) satellite observations. From the optimization, we estimate that global fires emit 45.5 Tg y -1 of primary particulate organic matter and 3.9 Tg y -1 of black carbon. We then performed two climate simulations with and without the optimized fire emissions. We find that fire aerosols significantly increase global AOD by 14 ± 7% and contribute to a reduction in net shortwave radiation at the surface (-2.3 ± 0.5 W m -2 ). Together, fire-induced direct and indirect aerosol effects cause annual mean global land surface air temperature to decrease by 0.17 ± 0.15°C, relative humidity to increase by 0.4 ± 0.3%, and diffuse light fraction to increase by 0.5 ± 0.3%. In response, GPP declines by 2.8 Pg C y -1 , as a result of large positive drivers (decreases in temperature and increases in humidity and diffuse light) nearly cancelling out large negative drivers (decreases shortwave radiation and soil moisture). Our analysis highlights the importance of fire aerosols in modifying surface climate and photosynthesis across the tropics.

54 ENVIRONMENTAL SCIENCES↗

Techno-economic analysis of the impact of dynamic electricity prices on solar penetration in a smart grid environment with distributed energy storage

This study investigates the technical and economic feasibility of using high levels of solar energy penetration up to 400 MW into a smart grid system of 60,000 smart houses. A novel non-cooperative Stackelberg game is introduced that incorporates the profitability of the supply-side and helps in solving problems related to overgeneration and photovoltaic curtailment. The non-cooperative game is intended to find the optimal dynamic prices that would leverage distributed storage through the demand-side to stabilize the power grid operation. Ten cases are studied with five photovoltaic plant sizes and two battery designs. Here, a novel quantitative analysis of high levels of solar penetration as a percentage of the total electricity demand is introduced to evaluate the technical feasibility of the studied cases. To evaluate the economic viability of the proposed smart grid system, four metrics were used: the levelized cost of energy, the levelized cost of storage, the payback period, and the net present value. Two out of ten studied cases were concluded to be the most promising cases, one with a solar photovoltaic plant size of 200 MW and the other with 300 MW. The case with 300 MW solar plant is preferred as it paves the way for more solar energy deployment with a solar penetration percentage up to 67.78%. This case had a payback period of 10.72 years and a net present value of $\$51.44$ M for the solar plant and a payback period of 12.06 years and a net present value of $\$40.75$ M for the demand-side.

14 SOLAR ENERGY↗